05000259/LER-1980-074-03, /03L-0:on 800924,during Normal Operation,Seismic Monitor SMA2 Found Inoperable.Caused by Failed Printed Wiring Board 100935.Assembly Repaired,Tested & Returned to Svc.Failure Considered Random.No Further Action Planned

From kanterella
(Redirected from ML19338G151)
Jump to navigation Jump to search
/03L-0:on 800924,during Normal Operation,Seismic Monitor SMA2 Found Inoperable.Caused by Failed Printed Wiring Board 100935.Assembly Repaired,Tested & Returned to Svc.Failure Considered Random.No Further Action Planned
ML19338G151
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 10/23/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19338G125 List:
References
LER-80-074-03L-01, LER-80-74-3L-1, NUDOCS 8010280511
Download: ML19338G151 (2)


LER-1980-074, /03L-0:on 800924,during Normal Operation,Seismic Monitor SMA2 Found Inoperable.Caused by Failed Printed Wiring Board 100935.Assembly Repaired,Tested & Returned to Svc.Failure Considered Random.No Further Action Planned
Event date:
Report date:
2591980074R03 - NRC Website

text

n l' i7 77:

V.

LICENSEE EVENT REPORT CONTROL 8 LOCK: l l

l l

l l lh (PLEAsE PRINT OR TYPE ALL REOUIRED INFORMATION) 1 6

'3111 l Al Ll Bl Rl Fl 1lg%0 l 0 l - l 010 l 0 l 0 l 0 l-l 0 l 0 ]@l 4 l 1 l 1 ] 1 l 1 l@l l

l@

7 8 9 LICENSEE CODE 14 1

uCENsEN WsER 46 28 uCEN5E Tvet 40 S7 cai 58 CON'T Lo L.]

s[RNlLl@l 0l 5 l 0 l 0 l 0 l 2 [ 5 l 9 @l 0 ] 912 l 4 l 8 l 0 @l 1l 0 l 2 l 3 l 8 l 0 l@

F 4

60 61 DOCK ET NUMSER 68 69 EVENT DATE 74 76 REPORT DATE SC EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h Ioi2l l During normal operation, seismic monitor SMA2 was four.d inoperable at 0730 (T.S. 3.2.J) m j 2).

Other seismic nonitoring instruments listed in T.S. Table 3.2.J were operable.

l ITTTlI There was no effect on the health or safety of the public. There have been no l

l p iprevious occurrences.

I I

lo is i I 10171 I l

I 101911 EoE

  1. ^$s' SUeC$E Co COMPONENT CODE SLSC CE S

E 10191 I Il Dj@ ]@ l E lQ l Il Nj Sl Tl Rl UlQ ]g ]@

J e

9 10 11 12 13 19 17 20 SEQUENTI AL QCCUR2ENCE REPCRT REVIS6CN LER RO EVENTvEAR REPORT NO.

COCE TYPE N*

@,ag l21 8l 0l l_l l0 l7 l4 l Qj l 0l 3l lLl 8

l d.j 22 23 24

.' 6 27 25 29 JJ 31 J2 T4 N A i N ON P NT VET MOURS,

  • n S8 TT FCR d 8

SL et. E VANLFACTLRER

( Bj@( ZJ@

W@

[_ ZJg l 0 l 0 l 0 l v g gg l Yg l Ll@

lK l1 13 l0 l@

JJ_

34_

26 3

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORREC11VE ACTIONS

,,;l Printed wiring board 100935 failed. The assembly was repaired, functionally tested, l

and retumed to service at 1630. The failure is considered random in nature and no g

l further corrective action is planned.

i lt l1l l l

I LLW I 90 F

d 3 STA 5

't. PoWE R OTHER STATUS ISCO RY DISCOVERv CESCRi8710N 32 JQ l0 l 9 l 5 l@l NA l

l A l@l Observed by maintenance perTonnel l

1 s

A Tivi t y CONTENT RELEASED 08 Af LE ASE AMCUNT CF ACTIVtTY LOC ATION C8 AELE ASE a

l I

I l&J LZJ @ L.zJ@l i

a 9 to it 44 45 80 Pf 6150NNE L F *POSLRE$

%%f H fY'E

DESCRIPTION

l0l0l0]@lZjgl NA l

i i

  1. fMSONNE INJV IE$

P' NMEH OESCRIPfiON NA l

[Ll_j l Jl 0l 0l@l 1

4 ?

11 12 30 L tr.S OF rp10 AVAGE TO F ACIL1TY ryPE DE SCRIP TION f' HI L2J@l I

i 1 9 to 30 E 96PT60N

,se,i#@l i

NA l

llllllllllll lj

< o M J 10 63 69 83 -

NAME OF PREPARER PHONE.

80102805N"

D**D

  • ]D N Y@"

owI w Ju L.NU %

.~

Tannessee Valley A'athority peri, 3 g.g 7 Browns Ferry Nuc! car Plant BF 15.2 1/10/79 LER SUPPLEMENTAL INFORMATION B F RO-50 259 / 8074 Technical Specification invo!ved Table 3.:..J.2 Reported Under Technical Specif! cation 6.7.2.b(2)

Date of Occurrence 9/24/80 Time of Occurrence 0730 1

Unit Identification and DescLp_ti_on of Occurrence:

i Seismic monitor SMA2 was found inoperable at 0730.

Conditions Prior to Occurrence:

U-l at 95% power U-2 shutdown for refueling U-3 at 87% power Action specified in the ~'schmcat Specif: cation Survet:!aac7 f(equirements met GA to ine,perable yquipent.

De scrite.

Instrument was returned to service within the time limit specified.

,.jp,irint C tqpe of Occurre_nce:

Failure of a printed wiring board assembly...

Analysis e.,f Occurrence:

There was no damage to any plant equipment. No ac.tivity released. No personnel exposure or injury and no danger to the public health or safety.

Cearective Action:

Repaired, functionally tested and returned to service at 1630.

F:njufo Data; None

  • .; Retention :

eried - Lifetime; Responsibility - Ad:uialstrative Supervisor O,

/

  • R e u.,.s on:

e

/

O