LER 80-007/01T-1:on 800315,in Mode 6 Following Initial Core Loading,Discovered Incorrect Valve Operator Weights Used in Seismic Analysis for Cooling Water Valves FCV-70-133,145 & 183.Caused by Manufacturer Labeling Error
ML19323F823
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 05/21/1980
From: Terpstra G
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19323F818 List:
References
LER-80-007-01T, LER-80-7-1T, NUDOCS 8005290509
Download: ML19323F823 (2)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

f r w -

PJnc 7 OR At 366 U.S. 74UCLEAR ftEGtiLATCrY s CO*.*VtS$tO*

11 773 g LICENSEE EVENT REPORT EXH181T /

(PLE!.$C Pr.sN r 04 TYPE ALL r.EQUlftED INF O;t'.' ATIONI coNTm t cicv.: [_W l l l .l@ i

.: 1.- al@

o i lT 2

l N.. [w Sl .,, N m a! P! a1!@ul Of 01 -l uw. 0101010.o. . . . . . i O ! -!0 i Oj@'

. , n 4 ...r.u

! 111 In 11 u ulj.@

ccsr 101il  :"'f.s Li@l015 ! 010 i O!31217 @! O ! 31115!

5 8 ! 0 '@l0 i e i. s. :  :. . o r .. v .a ., 4 .. a v e. r u . a  :+ ' 51 nc a .: e 21118 f Ol@ .)

Ever.T ot:cniaTiers . so ences.itr cossccutscts @

fi iTI Lyith unit 1 in d! ode 6 fol_1owing initial core loadir.n. notification was n;--r3 i received from TVA Division of Engineering Design that the incorrect (non-In ta i i conservative) valve operator weights were used in the seismic ar.alysis for i n , ,, , [ component cooling water valves FCV-70-133, 145, and 183 (T.S. 6.9.1.12.h).

[o g i , There was no danger to the health and safety of the public.

c l 71 ! Prgvious occurrences - none.

la rsi i r eco c ST 0 T I */ CAU- E C A' J CC"* vv.vf 0 0. 4 Co;g 5 i.t.;;:sf 0 0 "J .- 6*. 00?E C A * : .i S.,400:22 io m i win 18 LB J8 lij@ l V' A I t.! Vi E I x!@ L,EJG LG_J S 7 8 9 It) in I; 12 tt 1 iJ

. f rN 8*. rI AL CO* . s e h r.C". rrs-w 80.'!173 tvtar taa ,>t. o r.a c:a e,>i ,

O" ."u .. o 18 I 0]

.J.'.?;',',

_ Il JJ l--J 23 l O!0171

~4 .,

L -J

!0i 11

4 ;f i;~ T! l-J 31 Lij J .*

ty

,:i :.'.

O .*

  • p p re i8 L r' *g ..s. . t .. .:$

AC,r.:30'.s r r ec , o:.F.s . .sF.7C f

$ ..,.gv e,

o. ms O a ;= :.. A.c. . . . w, , c ... ...4 # $..
n.*. t. u s'. . S.*.

. .T, c LXISLXJS I Z!@ L3@ l 0 i Of CN : [YJ@ ljNj@ LAJ@ l X!9 I 9 ! 9

>> a 2. u 2, n .- ., n u 4 CAUSE O!ScRIPTICU A.'.O CoRetEc DVC ACf TOW @

li i s i l The Walworth Company (valve manu.) shows different valve operator weights

'g Lor differeat drawings for identical valves. TVA Divisio t of Engineering i,i,il Design used 116 lbs. for 1 & 2-FCV-133,134, and 183 in their piping i, ,,ii seismic analysis. The correct weights should be 135 lbs. The seismic g , analysis will be rerun using the' correct valve operator weights.

, ,s ., .

'#ft"i s coe.t n c.r..c n e rA ru: 8 ES23%  :::r.cri-ors:erio>@

R LBj @ l.010'O j@!N/A l Il@l Notification fro a TVA Desinn

%'. r: .. . , es::ca " " " '-

  • c

..t u ,.s . o . ., ... . , x t A. .o.,.. .u. -.e,.mem @,

ITTrTl. L,Z_j , ,, .m. , , @ l le N/A

@ L. zj@l N/A ,, o o i

r ,. re...

o . , > . ..n -

PJU'f 4I 58 7%eI .

  • f' I $'.

l i i i l 101 010 ;@[Z j@r.(* N/A I et e. A .*.s 's a s ei.'.[.t ras.". .t se nr:.cs.;P r e *f.

i IOIO!0l@l N/A I P 4' 'J tl I? #I t v.: os r.tr cA ?Ar.t t.o sr..su ; e t e. t t s .u

  • t se, 4 I W n[Z_j@l N/A I n u , ., e reu:nv e, rte ;.9 sp4t v

_ rr .e svernts:.

7 r. **.

. . .h# ,$l N/A l [tiriI'tI!II vI r n .> ,,, a u ev.or o cr.t ,. . ci,, Gary L. Terpstra ,, ,,,, e 615-842-0295 80 05290fbf

T$nnacEmoValleyAuthority -

Siqunyth Nucitar Plant LER SUPPLDfE!;TM. INFORMATION SQRO-50-327/8007 Technical Specification Involved 6.9.1.12.h Reported Under Technical Specification 6.9.1.12.h Date of Occurrenec: 3/15/E0 Time of Occurrence: 0900 EST Unit 1 Identification and Description of Occurrence:

Notification was received from TVA Divisien of Engineering Design that the incorrect (non-censervative) valve operator weight was used in the seismic analysis for component cooling water valves FC'.'-70-133, 134, and 183.

Conditions Prior to Occurrence:

Unit 1 in Mode 6 following initial core leading.

Action specified in the Technical Specification Surveillance Requirements met due to inoperable eculpment. Describe.

N/A Apparent Cauce of Occurrence:

Incorrect valve operator weight used in seismic analysis.

Analysis of Occurrence:

There was no hazard to the public health or safety.

Corrective Action:

The ueismic analysis will be rerun using the correct valve operator weights.

Failure Data:

N/A