05000259/LER-1980-047-03, /03L-0:on 800604,during Power Operation,While Testing Drywell Air Sampling Sys,Vacuum Pump Associated W/ RM-1-90-256 Failed.Caused by Normal Wear.Pump Was Replaced

From kanterella
(Redirected from ML19320A955)
Jump to navigation Jump to search
/03L-0:on 800604,during Power Operation,While Testing Drywell Air Sampling Sys,Vacuum Pump Associated W/ RM-1-90-256 Failed.Caused by Normal Wear.Pump Was Replaced
ML19320A955
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 07/01/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19320A950 List:
References
LER-80-047-03L, LER-80-47-3L, NUDOCS 8007080333
Download: ML19320A955 (2)


LER-1980-047, /03L-0:on 800604,during Power Operation,While Testing Drywell Air Sampling Sys,Vacuum Pump Associated W/ RM-1-90-256 Failed.Caused by Normal Wear.Pump Was Replaced
Event date:
Report date:
2591980047R03 - NRC Website

text

.-. _

~ y,' ' " > '

u s Nir u w.4.GUL A l f ** * '- d' ~%

LICECCE EVENT Nkhont

, CONTROL BLOCK: l l

l l

l l

lQ t..L ASE PRINT CR tv*E ALL REQUIEED INFO MATIEN) 1 6

l Al Ll Bl Rl Fl 1l@l 0 l 0 l -l 0 l 0 l 0 l 0 l 0 l - l 0 l 0 l@l 4 l 1 l 1 l 1 l 1 l@l l

l@

7 8-9 LICENSEE CODE le 15 LICENSE NUwSER 25 26 LICENSE TYPE JU SF CAI I

CorfT LoJ_d

"" % l Ll@l 015 l 0 l 0 l 0 l 2 l 5 l 9 ]@l 0 l 6 l 0 l 4 l 8 l 0 l@l ol 7 l0 l il 8l Ol@

S 7

8 t,0 61 DOC A ET NUMSE R 68 89 EVENT O ATE 74 75 RE*oRTDATE 60 EVENT DESCntPTION AND PROBABLE CONSEQUENCES h o 2 i With Unit 1 at 81 percent steady state power SI 4.2.E.2 was being performed on the I

g i drywell air sampling system when the vacuum pump associated with RM-1-90-256 was l

l found to be pulling an inadequate vacuum. The Chem Lab was notified to obtain l

o 4 F5T 1 I grab samples. There was no danger to the health or safety of the public, and no l significant re'sulting chain of events. A previous similar occurrence was reported l

o s ITTTl I on LER BFRO-50-259-79036. See Tech Spec 3.6.C.2.

l loia l i I

8,

v C E C DE S 9CO E cot /PONEN T CODE St. C C'E S

E l Bl Blg gg ]g lP lU lM lP lX lX [g ]g ]g o 3

'7 8

9 to 1

12 13 18 13 20 SEoVE NTI AL oCCunAEW.E REPORT REVISION LER RO EV8NT YEAR Rf PORT N ODE T PE Pg

@,gg; 18 i 0 i g

l0 l4 l l

jfl l

l l

l l

l __l g

,,,,. 21 22 23 24 26 29 28 29 30 31 32 KE A TC oJPL/*T V T4 f HoVfts S B' IT D 80 A B.

SV L1 VAN' F ACTunfit lAl@lZl@

(_Z,_l@

[ Zl@

l0 l0 l0 l0 l yg W@

y@

l Sl 0l 9l 3l 33 34 35 36 37 40 41 42 43 44 4;

CAUSE DESCRIPTION ANO CORRECTIVE ACTIONS h g l The pump failed to perform adequately due to normal wear from operation.

It was l replaced.

Schwitzer, Series 325. No additional recurrence control is planned.

i 2 I I

EI I

i 4 l

1 1

8 e no ST S

4*oWER oTHER S TATUS IS Ef Y D'SCOVERY DESCRIPTION l.'._L J U@ l 0 l 8 I i l@l NA l

l B !@l Routine testing j

AC TIVI Tv CONTENT i

RFLE ATED OF HELF ASE AYOt Nf oF ACTIVITY LOC 4TloN or nELE ASE L z] @ Lz_l@l Na i

i NA i

i c 7

8 9 10 Il 44 43 HH PERSON'4EL E uposunts Pfl1Ut1E R TYPE OESCPIPTION 10101 Ol@Lz_J@l NA l

i 2

,ERSoNNEl',~JubS otSCRinnoN@

Nuvatn I 0101 Ol@!

NA l

4 i a 7

.8 9

11 12 80 T yf t CESC 4 PT oN NA l

d @l 1 9 7

4 9 "J

SD DESCRs971*".

855UdEL 81 NA J

l l l l l l l l l 1 I l 17 2 a 0 0 7 0 8 t> 33 2 -

7 8 9 to NAMF OF pnFP Alvfe pHOP:E-

4 Ter.ncssee Valley Authority Fcra El '

Browns Ferry tiuc! car Plant

!! F "

1/te<.

i LER SUPPLEMENTAL INFORMATION r

3.6.c.2 B FRO 259 j 8047 Technical Specification Involved Reported Under Technical Specification

6. 7.2.b (2)

Date of Occurrence 6/4/80 Time of Occurrence 0801 Unit 1

l I_dentification and Description of Occurrence:

While perfoming SI 4.2.E.2 it was found that vacuum pump on RM-1:-90-256 on continuous air monitoring system to drywell was pulling inadequate vacuum.

i Conditions " Prior to Occurrence:

J Unit 1 - 81% steady state power

~

Unit 2 - 962 steady state power Uiiit 3 - 100% steady, state power Actiin spacified 'n the Technical Specification Surveillance Requirements m.

due to inopg.gle _ equipment.

Des crib e._

Chem Lab was asked to obtain grab samples Apparent Cause of Occurrence:

Normal wear on pump from operation.

l 1

i Analysis of Occurrence:

1 Therewasnodange[tohealthorsafetyofthepublic,noreleaseofactivity, i

no damage to plant or equipment, and no resulting significant chain of events.

Corrective Action

Pump was replaced.

F.tilure Data:

LER BFRO-50-259-79036

  • Retention :

criod - Lifetime; Responsibility - Ad:ninistrative Supervism

&'/

  • Revision:

/ ]U J