05000259/LER-1978-035-03, /03L-0 on 781201:during Test,One Wheeler Reservoir Level Monitoring Switch Failed to Operate Due to Moisture Short Circuiting the Amplifier Printed Circuit Board.Switch Calibr & Returned to Svc

From kanterella
(Redirected from ML19305A102)
Jump to navigation Jump to search
/03L-0 on 781201:during Test,One Wheeler Reservoir Level Monitoring Switch Failed to Operate Due to Moisture Short Circuiting the Amplifier Printed Circuit Board.Switch Calibr & Returned to Svc
ML19305A102
Person / Time
Site: Browns Ferry 
Issue date: 12/28/1978
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19305A099 List:
References
LER-78-035-03L, LER-78-35-3L, NUDOCS 7901040129
Download: ML19305A102 (2)


LER-1978-035, /03L-0 on 781201:during Test,One Wheeler Reservoir Level Monitoring Switch Failed to Operate Due to Moisture Short Circuiting the Amplifier Printed Circuit Board.Switch Calibr & Returned to Svc
Event date:
Report date:
2591978035R03 - NRC Website

text

-

U.S. NUCLEAR HEGULATORY COMMISSION

- NRC FORM 366 e

7(77"

-(

LICENSEE EVENT REPORT cO'NTROL DLOCK: l l

l l

l l

l (PLEASE PRINT OR TYPE ALL REOUIRED INFORMATION)

I 6

l A l L l B l R l F l 1 l@} 0 l 0 l - l 0 l 0 l 0 l 0 l 0 l-l 0 l 0 l@l 4 l1 l1' ll l 1 l@ll l@

0 1 7

8 9 LsCENSEE CODE 14 15 LICENSE NUMBER h

26 LICENSE TYPE JO 6 7 CA T bd CON'T 5$n*CE l L l@l 0 l 5 l 0 l 0 l 0 l 2 l 5 l 9 l@l 1 l 2 l 0 l1 l 718 l@l 1; 2 ] 2 l 8 l 7 l 8 ]@

0 1 7

8 60 68 DOC A ET NUVBER tid 69 EVENT DATE 14 75 REPORT D A1 E 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h [oTTI I While perfoming surveillance testing on the Wheeler reservoir level nonitoriny switches, l one of two switches failed to operate.

The redundant switch operated satisfac-l O 3 l torily.

Failure of the one switch placed the system in a degraded mode in accordance l o 4 0 s l with T. S. tabic 3.2.11.

There was no hazard to the public health or safety.

I O 6 l

l 0 7 l

l O 8 l

SYSTEM

CAUSE

CAUSE COMP.

VALVE CODE CODE SUSCODE COMPONENT CODE SU8 CODE SUBCODE l Il El@ lE l@ lE l@ l Il Nl Sl Tl Rl Uj@ W@ W @

o 9 7

8 9

to 11 12 13 18 19 zu SEQUE NTI AL OCCURRENCE REPORT REVISION LE R 'RO EVENT YE AR REPOHT NO.

CODE TYPE NO.

b njQRT l7 l8 l l0 l3 l5 l y

l 0l 3l g

g l0 l R

_ 21 22 23 24 26 27 28 29 J0 31 J2 1 N AC 0 ON P L NT MET HOURS SU IT O FO i B.

S PPLIE MAN F TURER [A_j@[_.Zj@

l Z l@

l Zl@

l0l0l0l0l

{ g lN lg ]@

lR l2 l9 l0l@

33 34 35 36 J/

40 di 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l 5 l o l l Moisture caused a short circuit in the amplifier printed circuit board. The amplifier l lin the Model 351-A switch was replaced.

The switch was calibrated and returned to I

i l service within a few hours. This problem was considered random in nature and no l

, 7 l recurrence control action was taken.

l

, 3 i 4 l

7 8 9 80 STA S

+. POWER OTHE R STATUS ISCO RY DISCOVERY DESCRIPTION W@ l0 l 0 l 0 l@l NA l

l Bl@l Surveillance testing l

s AC TIVITY CO TENT RELE ASED@OF RELE ASE[Z_J@l AMOUNT OF ACTIVITY LOCATION OF RELEASE

{_Z,j NA l

l NA l

1 6 7

8 9 10 ft 44 45 80 PERSONNEL EXPOSURES NUV8ER TYPE

DESCRIPTION

l0l0l0l@lZj@l N

l 1 7 PERSONN E L INJU tES NUMRER DESCRIP flON l0l0l0l@l N

l i a 7

8 9 11 12 80 LOSS OF OR DAMAGE TO FACILE TY TYPE DESCHIPTION Q ]Ql NA l

7 8 9 to 80

,SSUEf@t'lSCR,,T,0N @

790104oIp]

NRC USE ONLY LN l

NA _ _

l lllllllllllll{

2 a 7

8 3 to 68 69 80 NAME OF PREPARER PHONE:

fcrm DF-17 5

BF 15.2 6/09/78 3,

LER SUPPLEMENTAL INFORMATION BFRO-50 259

/ 7835 Technical Specification Involved 3 2.H

~

6.7.2.b.2 Reported Under Technical Specification Date of Occurrence 12/1/78 Time of Occurrence 1500 Unit common Identification and Description of Occurrence:

L.S.23-75B level switch failed to operate during surveillance 'esting.

t Conditions Prior to Occurrence:

Unit 1 - shutdown for refueling-

~

Unit 2 - operating at 97% power.

t Unit 3

, operating at 24% power.

Action specified in the Technical Specification Surveillance Requirements met due to inoperable equipment.

Describe.

Returned to service within thirty days.

i Apparent Cause of Occurrence:

Moisture caused a short circuit in the amplifier printed circuit board.

Analysis of Occurrence:

Redundant switch, LS-23-75B, was operable; consequeritly, an annunciation would have occurred if the reservoir level had risen.

Corrective Action

Amplifier printed circuit board was replaced, calibrated, and returned to service.

Failure Data:

l l

None Tennessee Valley Authority - Brown Ferry Nuclear Plant 1