LER 78-008/01T-0:on 780202,facility Flooded once-through Steam Generator Feedwater Nozzles During Operation Below 5% Full Power Per B&W Recommended Procedure
ML19261F260
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 02/16/1978
From:
METROPOLITAN EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19261F259 List:
References
LER-78-008-01T, LER-78-8-1T, NUDOCS 7910250698
Download: ML19261F260 (2)


Text

. February 16,1978 GQL c'%

NARRATIVE OF LICENSEE EVENT REPORT 78-08/1T *

'n' hen the Main Steam Line Break Analysis was originally performed, the B&W recc== ended operating procedure required a 30" vater levs1 in the CTSG's at low power levels. As B&W gained operating experience, flood-ing of the feedvater nozzles at low power levels was recce= ended to prevent thermal shocking of the nozzles. 'IMI-1 has been following the latter B&W recoc= ended operating procedure and operates with the second-ary side feedvater nozzles submerged when belov 5% full power in order to avoid kng-term feedvater nozzle ther=al degradation. Operation .

vith feedvater nozzles submerged, when below 5% full power was apparent ,

ly not considered for the Steam Line Break Analysis and is therefore reportable per section 6.9.2.A(9).

Since these conditions occur during startup and shutdown, which constitutes a small percentage of total operating time, the probability of a steam line . break occurring during startup or shutdown is significantly less than the probebility of a steam line break occurring as analyzed.

Preliminary Met-Ed analysis indicates that should a main steam line break occur during operation belev 5", full power with OTSG nozzles flooded, no return to criticality vill occur following reactor trip. However, the TMI-1 shutdown and cooldovn procedures have been changed to prevent opera-tion below 5". full power vitb the OTSG nozzles flooded. Met-Ed is atte=pting to verify the above preli=inary evaluation, and to obtain B&W's concurrence with Met-Ed's analysis.

4 1481 27I 791gggy

(URM 366 v. S UL. 6An hvULAl OrtY COMMlZION

)

LINNSEE EVENT REPORT CONTROL BLUCK: l 1

l l l l l lh 6

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

] lol3lmlvltl,l@l 01 0l -l Ol0 l0 l0 0 l- l0 l0 l@lL l1 8 9 LICENSEE CODE 14 15 LICENSE N6M8ER 25 26

._ lil1l@l LICENSE TY PE J0 l

57 CAT 58 l@

(T ,

3 8

"'3"C O

l60L l@ 610 l 5101010121819 DOCK ET NUMB ER 68 l@l69 01210121718 EVENT DATE 74 l@l012 75 li 16 I? lA80l@

REPCRT DATE EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h 1 lIn accordance with a B&W reccenended overating trecedure. mvI-1 kog wa - c1 mm. e I y 10TSG feedvater nozzles during operatien belev 5% full power. This cenditien was not I g analyzed in the FSAR and is therefore reportable ter 6.9.2. A(9) . Because this utm- 1 y tien occ;rs only during startup ar.1 shutdown, the erobability of a steam line break at1 4

9 l such times u significantly less than the probability of a steem line break cecurrinc !

] as analyzed. I I

1.l 80 8 9 SYSTEM CAUSE CAUSE COMP. VALVE CCDE CODE SUSCODE COMPONENT CODE SUSCODE SUSCODE I I z 12 l@ l_qj@ l Zl@ l Z I Z I z l Z I Z I z l@ LZ_J@ LZ_j @

8 9 10 11 12 13 18 19 20

,,, SEQUENTIAL OCCURRENCE REPORT REVISION LER RO EVENT YEAR REPORT NO. CODE TYPE N O.

@ , ureg U l8 l l-l l0 0l 8l [d l0 1l Tl [-j l0l 21 22 23 24 26 27 28 29 30 31 32

( KEN AC ON ON PL NT ME HOURS S8 I FOR B. SLPPLIE MANUFACTURER IC 33 l@lz 34 l@ lz l@

35 l36 Zl@ l 0] 0l 0l 0l 31 40 l Ylg 41 42 Nl@ l43 Zl@ l Z l 9 l9 44 947l@

CAUSE DESCRITTION AND CORRECTIVE ACTIONS o lWhen the Main Steam Line Break Analysis was originally performed, the B&W recc= mended l i (cperating procedure required a 30" vater level in the OTSG's at lov tower levels. As I 7 lB&W gained operating experience, flooding of the feedvater nozzles at low power levels 3 lvas reccc= ended to prevent ther=al shocking of the nozzles. The shutdown and cooldevnl 4 l procedures were changed to prevent floeding the nozzles when <:5% full power. .

[

8 9 80 ST  % POWER OTHER STATUS Dis O RY DISCOVERY DESCRIPTION B LF,_J@ l,Inlnl@l u "

I Iz l@l NA 'o I

' " '5 '8 A!TiviTY CATE~T aELEASED OF REL E ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE NA l l 'M l B 8la_] 9

@ Lz_i iO

@ 11 44 46 80 PERSONNEL EXPOSURES NUM8ER TYPE DESCRIPTION B8101010 -

l@lz l@l" NA PERSO~~Er.Na s NUMBE. oESCRiPTiO~@ I=481 272 B910 9 10 10l@l 11 12 NA 80 l

LOSS OF OR DAMAGE TO FACILITY TYPE D ESCHiP TION 8 9 h 10 NA 80 l

PU B LICITY NRC USE ONLY

  • ISSUED 2 [J_j@ DESCRIPTION l weakiv news release  !

IIIIIIIIIIIIl! ..