LER 1975-004-00 for R. E. Ginna, Failure of Solenoid Test Valves to Operate on a Main Steam Isolation Valve During Surveillance Test
ML18142B892
Person / Time
Site: Ginna Constellation icon.png
Issue date: 02/21/1975
From: White L
Rochester Gas & Electric Corp
To: O'Reilly J
NRC/IE, NRC Region 1
References
LER 1975-004-00
Download: ML18142B892 (7)


Text

.t HC DISTr. -UTluV X=OR PART "~0 DOCl' f l/j i ERlAL (TEi.iPOliARY . ORi'ii)

'CONTROL NO:

F l LE: MXQJM~EZQRT FRp,;,~ Rochester Gas & Elec. DATE OF DOC DATE REC'D ~I lviA

~ i \A LTR OTH=R Rochester, N Y.

L. D. White T I/21/75 2/25/75 TO: ORlG CC OTHER SEiVT AEC POR J. O'Rei l ly non signed EE SENT LOCAL PDR xxxx CLASS UiVC LASS PROPliVFO lNPUT NO CYS REC'D DOCKET NO:

XXX non signed 50-244 DES Rl. Tl ENCLOSURES:

Ltr trans the following: Rpt, 8 50-244/75-04, occurrence date'/21/75 re: one, of two(series-of air supply solenoids 'did.not trip to the closedx position although the coil armature did pick up I

PLANT NAM: ghana. 1)ONOT REMQVE BUTLER (S)

W/ Copies SCHWENCER W/ Copies (S)

FOR ACTlCX/li'FO>i';lATfON ZXEHANN (S) REGAÃ ZD~L25$

(E)

~

W/ Copies W/ Copies CLARK iS) STOLZ (S) DICKER (E) LEAR (S)

~

W/ Copies W/ Copies W/ Copies W/ Copies PARR (S) VASSALLO (S) KNXGHTON (E) SPEIS (S)

W/ Copies W/ Copies W/ Copies W/ Copies KNXEL (S) V PUR LE (S) YovNGBr,ooD (E)

W/ Copies M/ Copies W Co ies IMT o AL DISTxl l:"CUTIQV TECH REVIEW DEN TOE Ll:C. ASST. A/T XRD tAHC PDR GRL'iES DXGGS (S) BRAXT!IAE

. WGC, Rootf P-506"A NifACCARRY GAr&ILL GEARIN (S) SALTZNAN

~(ossr cK /sTAFF t4 N'XGHT VrQBTNER .' GOULBOURNE (S) B. HURT

@CASE UPAWLXCKX BALLARD KREUTZER (E)

GIANfBUSSO PEIAO SPANGLER IEE (S) PLASS BOYD <@TELLO llAXGRET (S) MCDONALD tfOORH (S) (BWR) i@OUSTON EllPXRO REED (E) CHAPtfAN DEYOUNG (S) (PWR) 4OVAK M)LIER SERVXCE (S) DUBE w/input SKOVHOLT (S) 0 OSS DICKER VSHEPPARD (8) E. COUPE Gor.LER (s) APPOLITO KNXGHTGN S>>TER (E) 9 R ~ Har tfield (2)

P. COLLXNS TEDESCO XOUNGBLOOD SHITH (S) ~KLECZER DENISE NG REGAN TFFTS (S) gP. WILLIAMS REG,OPR AINAS PROJECT LDR WXLLXAtfs (E)

@gjXLK & REGION Ci() 44ENAROYA wxrsoN (s)

M.R. WILSON MESTEE tAJOLXlfER HArdsss Xl GRAN (S) (.~)

E):TER(V 'AL DlS -RiBUTlOi~!

K"'LOCAL PDQyLB)X ~c,4+ $ 1) (2) (10) -NATxoNAr, LABs 1"PDR SAN/LA/NY

>>TIC (ABERNATAY) iV y ~l-i(, PENNXNGTON, RH'E-201 G.T. 1-BROOKHAVEN NAT LAB 6"NSXC(BUCHANAN) 1-CONSULTANTS 1-G, ULRIKSON, ORNL 1"ASLB NEWtfAfU(/BLUME/ASBABIAN 1-AGtfED(RUTH GUSStLAN) 1-NEfVON ANDERSON RH B-127 G.T.

+.-5-AcRS sENT To Lxc. ASST. 1"J. RU1K.ES) Rtf E-201 She( P>~~ G.T.

~ ~

lt I

~ e'< pii!<5! fi!j"'l'.ilail t

ISi/li/!"!'Ik~i'8i~fiTI 'p ROCHESTER GAS AND ELECTRIC CORPORATION 89 EAST AVENUE, ROCHESTER, N.Y. 14649 LEON O. WHITE. JR. TCLCPHONC YICC PRCSIDCNT RRCA COOC Via 546.2700 February 21, 19.75 O

\

Mr. James P. O'Reilly, Director ggf/yp'pttttt U. 'S. Nuc'lear"Regu'la'tory Commission 'Re Elg@<

Ittl Office of Inspection and Enforcement uttZ ee let ttez Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

Abnormal Occurrence 75-04, Failure of solenoid test valves to operate on "A" Main Steam Isolation Valve during surveillance test R. E. Ginna Nuclear Power Plant, Unit No. 1 Docket No. 50-244

Dear Mr. O'Reilly:

In accordance with Technical Specifications, Article 6. 6. 2a, the attached report of Abnormal Occurrence 75-04 is hereby submitted. 'Two additional copies of this letter and the attachment are enclosed.

Very truly yours, L. D. White, Jr.

Attachment cc: Mr. Donald F. Knuth (40)

4 n

C rJ'

50-244/75-04 0

February 21, 1975 2b. Occurrence Date: February 13, 1975

3. ~Faciltt: R. E. Ginna Nuclear Power Plant, Unit No. 1 4 .. Identification of Occurrence:

This abnormal occurrence is defined by Technical Specifications Article 1.9d: Failure of one or more components of an engineered safety feature or plant protection system that causes or threatens to cause the feature or system to be incapable of performing its intended function.

5. Conditions Prior to Occurrence:

The unit was operating. at a'steady state level of 100 percent power.

6. ~

Descri tion of Occurrence:

During the performance of the surveillance test, PT-20, "Main Steam Isolation Valve Solenoid Trip Test", upon actuating the Main Control Board (MCB) control switch for the "A" Steam Li'ne Isolation. Valve, one of the two series air supply solenoids did not trip to the closed position although the coil armature did pick up.

.An immediate r'etest resulted in the repeated failure of the same air supply valve to trip and in addition, one of the air exhaust valves failed to operate at this time. The MCB control switch operationand necessary, ~

resets were then performed several times with similar and erratic failure results. Instrument and Control Repairman personnel witnessed the operation and then made a minor adjustment to'the latching me'chanism.

Following this the test was satisfactorily performed five times without failure.

The test of the "B" Main Steam Isolation Valve trip was completed without incident.

7. Desi nation of A arent Cause of Occurrence:

In all cases the coil armature operated as required. The failure of the "A" solenoid valves was in their mechanical operation. It is believed that a flat spot or burr may have developed on the latching pin of the air supply valve trip mechanism. Rotation of this'pin from its fixed position produced the successful retesting. The exhaust valve trip mechanisms appeared stiff in action and responded properly after the several test operations.

~ ~S 4

I

~ \

~ g

\

I

AOR. 50-244/75-04 cont'+

8. Anal sis of Occurrence:

There was no hazard to plant personnel or the public. Due to the arrangement of the four solenoid valves, failure of the two solenoid valves in question would not have prevented closure of the "A" Main Steam Isolation valve.

The solenoid valves are tested every two months and had operated properly during the last three tests of August, October and December of 1974.

9. Corrective Action:

As described above, a reposition of the latching pin and the exer-cising of the mechanisms to overcome any linkage friction or binding of valve packings apparently corrected the problem.

The PORC.met at 1530 hours0.0177 days <br />0.425 hours <br />0.00253 weeks <br />5.82165e-4 months <br /> on February 13, 1975 to discuss the failure and recommended that the test be repeated prior to our scheduled outage on March 1-5, 1975 to determine the amount of maintenance to be performed on this system during the shutdown.

10. Failure Data:

Since th'e valves were mounted on the containment wall to reduce a vibration problem, there has been one other dissimilar failure of these solenoids prior to this occurrence. This failure occurred on June 26,1974 and was reported as Abnormal Occurrence 74-11.

The valves are Laurence Solenoid Valves, Cat. g 125434W (air vent valves), and Cat. g 110114W (air supply valves) for 125 psi. air.

They are manufactured by the R. G. Laurence Company, Inc., Tenafly, New Jersey 07670.