L-96-118, Forwards Response to Request for Addl Info Re Proposed Licensee Amends for SBLOCA re-analysis

From kanterella
(Redirected from ML17353A676)
Jump to navigation Jump to search
Forwards Response to Request for Addl Info Re Proposed Licensee Amends for SBLOCA re-analysis
ML17353A676
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 05/09/1996
From: Hovey R
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17353A677 List:
References
L-96-118, NUDOCS 9605140363
Download: ML17353A676 (8)


Text

CATEGORY 1 REGULA' INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9605140363 DOC.DATE: 96/05/09 NOTARIZED: YES DOCKET I FACIL:50-250 Turkey. Point Plant, Unit 3, Florida Power and Light C 05000250 GG-253. Turkey Point Plant, Unit 4, Florida Power and Light C

05000251 AUTH.NAME

'AUTHOR AFFILIATION HOVEY,R.J.

Florida Power s Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards response to request for addi info re proposed licensee amends for SBLOCA re-analysis.

DISTRIBUTION CODE:

ZOOID COPIES RECEIVED:LTR I

ENCL

(

SIZE:

TITLE: OR Submittal: General Distribution NOTES:

INTERNAL:

RECIPIENT ID CODE/NAME PD2-3 LA CRO NRR/DRCH/HICB NRR/DSSA/SRXB OGC/HDS3 COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

0 RECXPIENT ID CODE/NAME PD2-3 PD NRR/DE/EMCB NRR/DSSA/SPLB

.NUDOCS-ABSTRACT COPIES LTTR ENCL 1

1 1

1 1

1 1

1 EXTERNAL: NOAC 1

1 NRC PDR 1

1 NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5D-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED)

TOTAL NUMBER OF COPIES REQUIRED:

LTTR '2

'ENCL

'll

~

P.i%I MAY09]996 L-96-118 10 CFR 550.36 10 CFR 550.90 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555 Gentlemen:

Re Turkey Point Units 3 and 4

Docket Nos.

50-250 and 50-251 Request for Additional Information (RAI)

Proposed License Amendments By letter L-95-193, dated July 26, 1995, Florida Power and Light Company (FPL) submitted a request to amend Turkey Point Units 3 and 4 Technical Specifications.

The staff requested additional information to support the technical review of the proposed license amendments.

The response to these NRC questions is enclosed.

Should there be any questions, please contact us

~

Very truly yours, Sj R. J.

Hove Vice President Turkey Point Plant enclosure CC'.

D. Ebneter, Regional Administrator, Region II, USNRC T.

P. Johnson, Senior Resident Inspector, USNRC, Turkey Point W. A. Passetti, Florida Department of Health and Rehabilitative Services

'rr605l40363 960509 PDR ADOCK 05000250 P

,. PDR 4 "V l ()

an FPL Group company

s

STATE OF FLORIDA COUNTY OF DADE

)

) ss.

)

being first duly sworn, deposes and says:

That he is

Company, the Licensee herein; of Florida Power and Light That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.

R. J.

Hove Subscribed and sworn to before me this day of 1996.

C arne of Notary Public (Type or Print)

NOTARY PUBLIC, in and for the County of

Dade, State of Florida My Commission expires J- >>

"Pf'ommission No.

C JAMEs E. Kgp~

MYCOMMISSQII)IX;~gyp EXPIRES: Jgggy 2g Iggg R. J.

Hovey is personally known to me.

f

Enclosure Page 1-of 3 L-96-118 SMALL BREAK LOCA SUBMITTAL REQUEST FOR ADDITIONAL INFORMATION QUESTION:

Request for additional information response letter L-96-066 dated March 13, 1996, identifies an abbreviation of "PCT" as Peak Centerline Temperature.

Is this correct?

RESPONSE

The abbreviation "PCT" defined in the second paragraph on page 2 of 4 of L-96-066 should be Peak ~Qjzlg Temperature, QUESTION:

"The original submittal letter L-95-193 dated July 26,

1995, on attachment 1, page 2, reference 4.

Is this the correct reference, or should it be WCAP-10054-P REV 1 OCT.

1995?"

RESPONSE

Revision 1 of WCAP-10054-P, Addendum 2 was issued in October

1995, subsequent to the submittal of the Small Break LOCA Re-analysis Proposed License Amendment.

The Turkey Point Units 3 and 4 Uprate Small Break LOCA analysis was performed consistent with the methodology described in WCAP-10054-P, Addendum 2, Revision 1, October 1995.

As a result, a revised Technical Specification (TS) reference will be required.

TS 6.9.1.7 Core Operating Limits Report, requires that the analytical methods used to determine K(z) be reviewed and approved by the NRC.

WCAP-10054-P, Addendum 2, Revision 1, October 1995 is presently under review by the NRC and not approved.

The following revised references are provided:

3.

WCAP-10054-P-A, (proprietary),

"Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code",

August 1985.

WCAP-10054-P, Addendum 2, Revision 1 (proprietary),

"Addendum to the Westinghouse Small Break LOCA ECCS Evaluation Model Using the NOTRUMP Code: Safety Injection in the Broken Loop and Improved Condensation Model", October 1995.+

"This reference is only to be used subsequent to NRC approval.

~

k h

'i