L-86-138, Application for Amends to Licenses DPR-31 & DPR-41,modifying Tech Spec Section 5.2, Reactor, to Allow Use of Burnable Poisons in Form Other than Discrete Rod Clusters,But Integral to Fuel Design.Fee Paid

From kanterella
(Redirected from ML17342A456)
Jump to navigation Jump to search
Application for Amends to Licenses DPR-31 & DPR-41,modifying Tech Spec Section 5.2, Reactor, to Allow Use of Burnable Poisons in Form Other than Discrete Rod Clusters,But Integral to Fuel Design.Fee Paid
ML17342A456
Person / Time
Site: Turkey Point  
Issue date: 04/15/1986
From: Woody C
FLORIDA POWER & LIGHT CO.
To: Thompson H
Office of Nuclear Reactor Regulation
Shared Package
ML17342A457 List:
References
L-86-138, NUDOCS 8604210092
Download: ML17342A456 (7)


Text

REGULATOR'1 NFORMATION DISTRIBUTION l EM (R IDS)

ACCESSION NBR: 860421 0092 DOC. DATE: 86/04/ 1 5 NOTARIZED: YES DOCNET ¹ FACIL: 50-250 Tuv'l;eg Point Plant.

Unit 3> Flov'i da Pommer and Light C

05000250 50-251 Tuv keg Point Plant>

Unit 4>.Flov ida Power and Light C

05000251 AUTH. NAME AUTHOR AFFILIATION WOODY. C. O.

Flov ida Power 8c Light Co.

RECIP. NAME RECIPIENT AFFILIATION THOMPSON> H. L Division o+ Pressuri zed Watev'eactov'icen sing A (post 8'UBJECT:

Application for amends to Licenses DPR-31 Zc DPR-41> modify ing Tech Spec Section

5. 2>

"Reactor> " to allow use of burnable poisons in fovm othev than discrete v od clustev s> but integv'al to fuel design. Fee paid.

DISTRIBUTION CODE:

AOOID COPIEB RECEIVED: LTR ~

ENCL ~<

BITE:~~)

TITLE:

OR Submittal:

General Distribution NOTES:

RECIPIENT ID CODE/NAl'IE PWR-A ADTS PWR-A EICSB PWR-A PD2 PD 01 PWR-* PSB INTERNAL: ADM/LFMB T/TSCB IL 04 COP IES LTTR ENCL 1

0 2

2 5

5 0

1 1

. RECIPIENT ID CODE/NAME PWR-A EB PWR-A FOB McDONALD> D PWR-A RSB ELD/HDS4 NRR/GRAS RQN2 COPIES LTTR ENCL 1

i.

1 1

0 1

0 EXTERNAL: 24X LPDR NSIC 03 05 1

1 1

1 1

EQi4~Q BRUSQUE> S NRC PDR 02 TOTAL NUMBER GF COPIES REQUIRED:

LTTR 24 ENCL 20 r

b.

1'

~

R r

FLORIOA POWER & LIGHTCOMPANY ape

~ 5""

L-86-138 Office of Nuclear Reactor Regulation Attention: Mr. Hugh L. Thompson,3r., Director Division of P WR Licensing - A U. S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Thompson:

Re: Turkey Point Units 3 and 0 Docket Nos. 50-250 and 50-251 Proposed License Amendment Reactor Core In accordance with 10 CFR 50.90, Florida Power 4 Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and Ol.

The proposed amendment modifies the Technical Specifications, Section 5.2 Reactor, to allow the use of burnable poisons that are not in the form of discrete rod clusters but are integral to the fuel design.

Westinghouse Electric Corporation, Water Reactor Divisions, issued Topical WCAP-10000-P-A, "Reference Core Report YANTAGE 5 Fuel Assembly" and received NRC approval in a SER dated 3uly 1985.

In addition, Westinghouse issued Addendum I to WCAP-10000-P-A and received NRC approval on March 12, 1986.

The proposed change adds additional design information not found in Rev. 5 (Draft) of the Westinghouse Standard Technical Specifications.-

The format of this section will be modified as part of our Standard Technical Specification conversion submittal.

The proposed Technical Specification is shown on accompanying Page 5.2-1.

Attachment 1 provides Addendum 1 to Westinghouse Topical WCAP-IOOOO-P-A, "Evaluation of IFBA Impact on Fuel Design for AllFuel Rod Arrays".

A safety evaluation of this proposed change is provided in Attachment II.

In accordance with 10 CFR 50.91(a)(l), we have determined that this amendment does not involve any significant hazards considerations pursuant to 10 CFR 50.91(c).

A discussion of our evaluation is provided in Attachment II.

In accordance with 10 CFR 170.12(c), a check for $ 150.00 is attached.

8604210092 Bb04i5 PDR ADOCK 05000250 PDR Ll:I PEOPLE... SERVING PEOPI E

Mr. Hugh L. Thompson, Jr., Director L I 38 Page two ln accordance with IO CFR 50.9I(b)(l), a copy of the proposed amendment is being forwarded to the State Designee for the State of Florida.

The proposed amendment has been reviewed by the Turkey Point Plant Nuclear Safety Committee and the Florida Power 6 Light Company Nuclear Review Board.

Very truly yours,

.O. Wo Group Vi resident Nuclear Energy CO W/RG/gp Attachments:

Attachment I

Attachment II FPL Check No. 083 I cc:

Dr. J. Nelson Grace, USNRC, Region II Harold Reis, Esq.

Mr. Allan Schubert, Manager Public Health Physicist and Rehabilitative Services Department of Health and Rehabilitative Services l323 Winewood Boulevard Tallahassee, FL 3230 I RG I /027/2

1 kt rh

STATE OF FLORIDA

)

)

ss.

COUNTY OF DADE"

)

C. O. Woody, being first duly sworn, deposes and says:

That he is a Group Vice President of Florida Power 4 Light Company, the licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said Licensee.

C. O. Wo Subscribed and sworn to before me this

/8 day of

, 1936.

k t /

C.

~.

$46~TAQY.PUBLIC, in and for the County of

" Dade-

'.a~t'e;oi Florida.

My commission expires:

HOTARY PUBLIC STATE OF FlORIDA HY COKKISSIOH EXP SEPT 18,1989 HRU GEHERAL IHS ~

UHD0

1i 4')

I, y,41 s+

I

, ~

El 1t

~rg J1q><

~<>> ~ s