L-80-417, Application to Amend Licenses DPR-31 & DPR 41 Authorizing Proposed Changes to Tech Specs Per TMI Lessons Learned
| ML17340A521 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 12/23/1980 |
| From: | Robert E. Uhrig FLORIDA POWER & LIGHT CO. |
| To: | Eisenhut D Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML17340A522 | List: |
| References | |
| L-80-417, NUDOCS 8012300320 | |
| Download: ML17340A521 (10) | |
Text
F
~
e So REGULAT RY INFORMATION DISTRIBUTION'YSTEM (RIDS) ie ACCESSION NBR:801230032 DOC ~ DATE! 80/12'/23 50 ARIZED: NO, DOCKET' FACIL:50 250 Turkey Point Planti Unit 3E Florida Power and Light C'5000250 50 251 Turkey Point Plant-E Unit OP Florfdai Power and Light C
05000251 AUTH'AME AUTHOR AFFILIATION UHRIGg R ~ E ~
Flor.fda Power 8 Light Co.
'REC I P ~ NAME RECIPIENT AFFILIATION EISKNHUTEDRG.
Division of LicenSing.
SUBJECT:
Application to amend Licenses DPRss31 L DPR Qi authorizing proposed ohsnBes to Tech Speos per TNI Lessons Learned;.
DISTRIBUTION.CODEt ABOIS COPIES RECEIVED:LTR.
ENCL.
SIZE..., P'.I ~
TITLKg General Distribution for after. Issuance of Operating Lfcense NOTES'ECIPIENT IO CODE/NAME ACTION VARGAg S ~
OQ'OPIES LTTR ENCL 13 RECIPIENT ID COOK/NAME" COPIES LTTR ENCL INTERNAL: D/DIR g HUM ILE OEL FIL EXTERNAL: ACRS NSIC FAC08 Obil 0 ir 09 05I 1
1 2
2 1
0 1
1 16 16 1
1 1
1 1-1 0
LPDR 03
~
1 OIR"p OI V OF LIC NRC. PDR 02" OR.ASSESS BR 10 TOTAL'UMBER OF COPIES REQUIRED!
LTTR 39 ENCL-37"
iP il J
II f
C u
P.O. BOX 529100 MIAMI,F L33152 FLORIDAPOWER & LIGHTCOMPANY December
?3 1980.
L-80-417 Director of Nuclear Reactor Regulation Attention:
Hr. Darrell G. Eisenhut, Director Division of Licensing U.
S. Nuclear Regulatory Commission Washington, D.
C.
20555
Dear Hr. Eisenhut:
RE:
Turkev Point Un'.ts 3
8 4 Docket Nos 50-250 8 50-251 Proposed Amendment to Facility 0 eratin Licenses DPR-31
& DPR-41 In accordance with '10 CFR 50.30, Florida Power 5 Light Company submits herewith three (3) signed originals and forty (40) copi'es of a request to amend Appendix A of Facility Operating Licenses DPR-31 and DPR-41.
This proposal is submitted in response to your letter of July 2, 1980.
The license condition changes from Enclosure 2 of that letter have not been included in this proposal-These items will be forwarded as a separate request.
The proposed changes are shown on the acccmpanying Technical Specification pages bearing the date of this letter in the lower right hand corner.
The proposed amendment has been approved by the Turkey Point Plant Nuclear Safety Committee and the Florida Power 8 Light Company Nuclear Review Board.
Very trul
- yours, Robert E-Uhrig Vice President Advanced Systems 8 Technology REU/HAS/ras N)NbG Qgg'g3S NOllAGIHI Sl6 QN> N Attachment 930 ~<~
cc:
Hr. James P. O'Reilly, Region II Harold F.
Rei s, Esquire J.IHA S"'AIA1";.
IN)LAtilUL~~l'-""-"
'-'='oza3008>
PEOPLE... SERVING PEOPLE
'I
l5
'I g
f
RE:
Turkey Point Units 3 8 4 Proposed Tech Spec Change TMI Lessons Learned ATTACHMENT Pa e 3.l-la Specification 3.1.1 is expanded to include the pressurizer, the
- PORYs, and associated block valves.
The requirement for a monthly flux map is moved to Chapter 4, Surveillance Requirements (Table 4-1-1).
Pa e 3.3-1 Containment Isolation Yalves are added to Specification 3.3.
Pa es 3.5-1 and Tables 3.5-2 3.5-4 8 3.5-5 Additional accident monitori ng instrumentation is added to Specification 3. 5 and the Tables for ESF Actuation and ESF Setpoints-Table 3.5-5 is a new Table-Table 4.1-1 Sheets 1~3 and 4
Testing requirements for certain AUXILIARY FEEDWATER INSTRUMENTATION and ACCIDENT MONITORING INSTRUMENTATION.are added to this Table (Minimum Frequencies for Checks, Calibrations, and Test of Instrument Channels).
This requirement for a monthly flux map is also added to this Table.
Pa e 4-10-1 Specification 4.10 is expanded to include 18 month testing requirements for the Auxiliary Feedwater System.
Table 6.2-1 Shift manning requirements are modified and include the Shift Technical Advisor.
P.a<ac 6-5 Miniminum qualifications for the Shift Technical Advisor are added to Specification 6.3.1.
P I
Presssurizer The pressurizer shall be operable with a steam bubble, and with at least 125 KM of pressurizer heaters capable of being supplied by emergency
- power, when the reactor coolant is heated above 350F.
e.
Relief Valves l.
A power operated relief valve (PORY) and its associated block valve shall be operable when the reactor coolant is heated above 350F.
2., If the average coolant temperature is greater than 350F and the conditions of 3.l.l-e-l cannot be met because one or more PORV(s) is inoperable, within 1
hour either restore the PORV(s) to operable status or close the associated block valve(s) and remove power from the block valve(s); otherwise, be in a condition with Keff < 0-99 within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in cold shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
3.
If the average coolant temperature is greater than 350F and the conditions of 3. 1.1-e.l cannot be met because one or more block valve(s) is inoperable, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> either restore the block valve(s) to operable status or close the block valve(s) and remove power from the block valve(s); otherwise, be in a condition with Keff < 0.99 within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in cold shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
- 3. 1-1 a
i
(b)
(1')0 i
r The measurement of total peaking facto F~ a h
r,, shall be tolerances nc eased by three percent to account for q f
and further increased by five percent to ac t
r manu acturing for measurement error-o account (2}
T(e measurement of the enthaipy rise hot h
F shall b
c anne
- factor, H, s a
e increased by four percent to account for measurement error.
If the measured hot channel factor exceeds it 1
t under Item /a the reactor power shall be reduced so as not to s i s imit specified exceed a fraction of the rated value equal to th t'
eraioof theF imit to measured
- value, whichever is less, and the hi h neutron flux trip setpoint shall be reduced by the same ratio-If subsequent incore mapping cannot, within a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period shall be demonstrate that the hot channel factors t,
h e brought to a hot shutdown condition with return to ower authorized only for the purpose of.physics testin Th may be returned to hi her th t h o
ig er power levels when measurements indicate a
ot channel factors are within limits.
The reference equilibrium indicated axial flux difference as a
function of power level (called the target flux difference) shall be measured at least once per effective f 11 the axial flux difference has not been measured in the last effective full power month, the target flux difference must be updated monthly by linear interpolation using the most recent measured value and the value predicted fo th d f life.
r e en o
the cycle d.
e.
Except during physics tests or during excore calibration procedures and as modified by items Ge through 6
b 1
indicat ed axial flux difference shall be maintained with a + 5$
band about the target flux difference
( this defin h
band on axial flux difference).
is e ines t e target If the indicated axial flux difference 'at a power level reater than 905 of rated power deviates
- 3. 2-4
i~