05000251/LER-1980-008-01, /01T-0:on 800523,review of Radiographs Per IE Bulletin 79-13 Revealed Indications of Cracking in Feedwater Nozzle to Pipe Weld on Steam Generator 4 C Reducers.Cause Not Stated.Fittings Containing Defects Are Being Replaced

From kanterella
(Redirected from ML17339B132)
Jump to navigation Jump to search
/01T-0:on 800523,review of Radiographs Per IE Bulletin 79-13 Revealed Indications of Cracking in Feedwater Nozzle to Pipe Weld on Steam Generator 4 C Reducers.Cause Not Stated.Fittings Containing Defects Are Being Replaced
ML17339B132
Person / Time
Site: Turkey Point 
Issue date: 06/09/1980
From: Schoppman M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17339B131 List:
References
IEB-79-13, LER-80-008-01T-01, LER-80-8-1T-1, NUDOCS 8006230571
Download: ML17339B132 (4)


LER-1980-008, /01T-0:on 800523,review of Radiographs Per IE Bulletin 79-13 Revealed Indications of Cracking in Feedwater Nozzle to Pipe Weld on Steam Generator 4 C Reducers.Cause Not Stated.Fittings Containing Defects Are Being Replaced
Event date:
Report date:
2511980008R01 - NRC Website

text

NRC FORM Sdp rr TT)

i UCENSEE EVcNT REPORT U S.NUCLEAR RKOULATORYCOVIMISSION CONTROL BLOC@I I

I I

~ Ol [PLSASS PRINT OR TYPS ALLRfCUtRHZ INFOR!vIATIONl I

IQ I

I I

I I

I-I "Q I

I O~IQ 8

9 UCSNSSS COOS UC>>SNSS NUMSSR 35 SS L CSNS8 TiVt>>

'0 ST CON'T OCHl

"'.".*'.I'0 '

' 0~(6~II 0

80 SI COCKST NUAIS8 R od 49

'VCNTOATS Ia 15 REPORT OATS 50 SVSNT OSSCR

!PTIOPI ANO PROS ASLS CONSZCUmmCSS OO

~O2 'eview o inspections revealed indications of cracking in the feedwater nozzle to e weld ar'ea on steam enerator 4C.

S ecificall the I

are located ad acent-to the nozzl'e to reducer'veld are oriented

~o 8

circumferentiall in the 18 x 14 inch reducer base m

S.'iotts were observed in the radiographs associated vith these areas on the 4A and 43 reducers.

1 9

SYSTS u CAUSS CAUS 8 CQMP.

VAt.Vf CQOS COOS SUSC Qf CCMPONSNT COOL SUSCQQS SUSCQOf

~09 "0 nnm aim~m onm n<<0 l

4 9

Io II

-'= IS IS IS I9 30 SfCUSNllAL OC<<JRRSNC>>

RftORT VSNTVSAR

- R SPORTNO,,

COOS*-

  • TVPf

~

'- -'-1IQ" <<<<"'880'J

.~:"-,:~0:0 18 '.; ~m.:.,-:.~01

~T ACTION FUTUR8 fttfce 5NUTOQwN~",

Al,ACNMSNl'PROUT tRIAISCQMS, TMSN ACTIQN ON tLANT ufTIIQD';"-8 IIQURs ~22 sufMITTfo AIR!ll>us.

svtPUSR LcsLzls. mls els 'mia0 tos Itis Ins CAUSS OLISCRIPTION ANO CORRSC'AVE ACTloNS Q23 i

Re airs are'hain im 1'emented to remove and re lace the Zittin s RSVI5ION ~

COMPO NfNT hllAHUFACTUR8R Aa 47 contain-ing the defects.

Baseline inspections villbe performed prior to return-in the unit to service.'-

A full accountin of i e

io re pairs will be made in response to I & E Bulletin 79-13.

~I 3

8, 9

FACILITY.

ST*TU5 el POWS R s

MQ~

IL001 lgJQ9 5 8'0 IS IS ACTIVITY CQNTSNT RfLSASSO OF RSLSASS AAIOUN S

~Z QSS

~ZOSS NA l

3 9

10 II aA P>>RSQHNfl. SIIPOSURSS NUMSS R Tvtf ofscFIPrON Q~

L001o0 O0 liQ<<~ZQS NA 7

I I If 13 PSRSCNNS L INIUR!9 3 3

5 9

lf LCSS OF CR DAM*OfTO FACIUTY~48 Yta'fSCRIPTIQN 9

LZ~Q42 NA 7

9 9 'o tudUC:~a.

~If!QA NA 8 9:0 NA 45 30 NRC tlSa ptll Y itd 90 pvoNS, 305-552-3802 NAvls oF FRspAR;R H. A. Sebo man ufTIIOQOS OTIISR STATUS ~

OISCQVS RV 015COV>>RV OSSCFIPTIQN O2 LJS AS ds TQF ACRVITVOSS LCCATIQNOF RfLSAS8 OSS SPPP88P~

It (

0

'"REPORTABLE OCCURRENCE 251

- 08 LICENSEE EVENT REPORT PAGE 2 ADDITIONAL EVENT DESCRIPTION AND PROBABLE CONSE UENCES-On Friday, Hay 23, 1980 review of radiographs taken in accordance with USNRC I 5 E Bulletin 79-13 inspections revealed indications of cracking in the feedwater nozzle to pipe weld area on steam generator 4C.

Specifi.cally, the crack indications are located adjacent to the nozzle to the reducer weld and are oriented circumferentially in the 18 x 14 inch reducer base metal.

The indications were confirmed by ultrasonic testing.

Subsequent review of radiographs and ultrasonic test results on 4A and 4B steam gen-erators nozzle welds revealed similar indications.

Radiographs of A, B, and C steam generator feedwater nozzle welds on Unit 3 were reviewed and no abnormal ind',cations were observed.