GO2-92-154, Submits Addl Info Re 920318 Application for Amend to License NPF-21,changing TS Surveillance Requirement 4.6.6.1.B.3 to Include Addl Acceptance Criterion for Temp Profile within Hydrogen Recombiner Bed,Per NRC Request

From kanterella
(Redirected from ML17289A651)
Jump to navigation Jump to search
Submits Addl Info Re 920318 Application for Amend to License NPF-21,changing TS Surveillance Requirement 4.6.6.1.B.3 to Include Addl Acceptance Criterion for Temp Profile within Hydrogen Recombiner Bed,Per NRC Request
ML17289A651
Person / Time
Site: Columbia 
Issue date: 06/25/1992
From: Sorensen G
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17289A652 List:
References
GO2-92-154, NUDOCS 9206300196
Download: ML17289A651 (8)


Text

) ACCELERATED DISTRIBUTION DEMONSTjRATION SYSTEM REGULAT INFORMATION DISTRIBUTIOtISTEM (RIDE)

, ~

ACCESSION NBR:9206300196 DOC.DATE: 92/06/25 NOTARIZED:

NO DOCKET FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe 0500039<7'UTH.

NAME AUTHOR AFFILIATION SORENSEN,G.C.

Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amend to license NPF-21,revising SR 4.6.6.l.b to include addi acceptance criterion for temp profile within hydrogen recombiner bed.

DISTRIBUTION CODE:

A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal: General Distribution NOTES:

RECIPIENT ID CODE/NAME PD5 LA DEAN,W.

INTERNAL: ACRS NRR/DET/ESGB NRR/DST SE2 NRR/DST/SICBSH7 NUDOCS-ABSTRACT OGC/HDS1 RES/DSIR/EIB EXTERNAL: NRC PDR COPIES LTTR ENCL 1

1 2

2 6

6 1

1 1

1 1

1 1

1 1

0 1

1 1

1 RECIPIENT ID CODE/NAME PD5 PD NRR/DET/ECMB 7D NRR/DOEA/OTSB11 NRR/DST/SELB 7E NRR/DST/SRXB SE

.C LFMB G

LE NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

0 1

1 1

1 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTETH CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED)

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 24 ENCL 22

WASHINGTONPUBLIC POWER SUPPLY SYSTEM P.O. Bec96'8 ~ 3000George Washington Way ~ Rtcbland, Wasbtngton 99352496'8

~ (509) 372-5000 June 25, 1992 G02-92-154 Docket No. 50-397 U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Gentlemen:

Subject:

WNP-2, OPERATING LICENSE NPF-21 RE(UEST FOR AMENDMENT TO TECHNICAL SPECIFICATION 4.6.6.1.B.3 PRIMARY CONTAINMENT ATMOSPHERE CONTROL (ADDITIONAL INFORMATION)

Reference:

Letter G02-92-064, dated March 18,

1992, GC Sorensen (SS) to
NRC, same subject In the reference, the Supply System requested an amendment to WNP-2 Technical Specifications surveillance requirements for the Containment Atmosphere Control System (CAC). After several discussions with WM Dean and AJ D'Angelo of the NRC, the Supply System has decided to modify the original request.

Specifically, Surveillance Requirement 4.6.6. l.b should be revised to include an additional acceptance criterion for the temperature profile within the hydrogen recombiner bed.

The proposed revision is included as Attachment 1 to this letter.

In support of this revision, the corresponding changes to the bases are shown in Attachment 2.

As discussed in the reference, the Supply System believes that measuring less than 25 parts per million by volume (ppmV) hydrogen in the effluent stream, after the introduction of at least a

1% hydrogen concentration to the recombiner skid provides acceptable indication of the operability of the catalyst.

However, additional information about the degradation of the bed may be obtained by monitoring the temperature profile through the catalyst bed.
Ideally, a catalyst bed should show a sharp increase in temperature within the first few inches of the bed upon the introduction of hydrogen and oxygen.

Under ideal equilibrium and adiabatic conditions, downstream temperatures should indicate little or no increase because the reaction has been essentially completed in the first few inches.

In actual testing where neither equilibrium nor adiabatic conditions exist, the downstream temperatures should be consider-ably lower than the peak temperature.

If the catalyst activity is degraded for any reason, the reaction will take place further into the bed and the peak temperature will occur further down.

9206~00>+~ +~pppg97 cyppb25 PDR ADOCN, 05o p t'A.

t Page Two RE(VEST FOR AMENDMENT TO TECHNICAL SPECIFICATION 4.6.6.1.B.3 PRIMARY CONTAINMENT ATMOSPHERE CONTROL (ADDITIONAL INFORMATION)

The majority of our tests have shown the peak temperature to be at the second in-bed detector which is approximately at the 30% level.

A few tests have shown peak temperature at the third detector which is approximately at the 60% level.

There has not been a consistent downward trend and we believe these few cases have been due to lower initial temperatures and/or varying heat loss conditions from year to year.

The surveillance tests are run without the electric preheater at inlet temperatures around 250'F rather than the design inlet temperature of 500'o 550'F.

It is important to note that a catalyst bed and its ability to recombine hydrogen and oxygen does not deplete simply from use.

Any reduction in recombination capability is caused by poisoning or other damage to or loss of catalyst, or by insufficient activation energy (low inlet temperature).

Given adequate inlet temperature, the presence of poisoning in the top few inches of the bed will simply move the peak reaction further down in the bed with very little effect on the percent completion of the reaction.

Any such downward movement in the site of the majority of the recombination should be evaluated to determine any actions that may be necessary.

Taking temperature readings of the catalyst bed during the surveillance to determine that the recombination process is occurring in the upper 60% of the bed will provide the data to support the analysis of the capability of the catalyst.

Measuring the hydrogen concentration in the effluent stream provides the necessary information that in fact the catalyst is able to recombine hydrogen and oxygen.

The evaluation of the change of location of that recombination process provides indication of the potential degradation of the catalyst.

The Supply System has determined that monitoring the relative temperature profile in the recombiner catalyst bed does not involve a significant hazards consider-ation for the following reasons:

It does not involve a significant increase in the probability or consequences of an accident.

The recombiners are provided as an accident mitigating feature and, as

such, do not have the potential to cause an accident or increase the consequences of an accident.

The temperature rise criterion combined with the measurement of the hydrogen concentration in the effluent stream provides information of the operability and capability of the recombiner skid.

It does not create the possibility of a new or different kind of accident.

No new methods of system operation are introduced by the request.

Accordingly, no new or different kind of accident is credible as of result of this request.

It does not create a significant decrease in the margin of safety.

The proposed data recording provides information concerning the health of the catalyst.

This provides additional assurance that the catalyst bed will be able to perform the required functions in the event of the design bases accidents.

Hence, this request does not represent a decrease in the margin of safety.

I<

t Page Three RE(VEST FOR AHENDHENT TO TECHNICAL SPECIFICATION 4.6.6.1.B.3 PRIHARY CONTAINHENT ATHOSPHERE CONTROL (ADDITIONAL INFORHATION)

As discussed above, the Supply System considers that this change does not involve a significant hazards consideration, nor is there a potential for significant change in the types or significant increase in the amount of any effluents that may be released offsite, nor does it involve a significant increase in individual or cumulative occupational radiation exposure.

Accordingly, the proposed change meets the eligibility criteria for categorical exclusion set forth in 10CFR 51.22(c)(9) and therefore, per 10CFR 51.22(b),

an environmental assessment of the change is not required.

This Technical Specification change has been reviewed and approved by the WNP-2 Plant Operations Committee (POC) and the Supply System Corporate Nuclear Safety Review Board (CNSRB).

In accordance with 10CFR 50.91, the State of Washington has been provided a copy of this letter.

G.

C. Sorensen, Hanager Regulatory Programs (Hail Drop 280)

HGE/bk Attachments CC:

JB Hartin -

NRC RV NS Reynolds

- Winston

& Strawn WH Dean NRC DL Williams - BPA/399 NRC Site Inspector

- 901A

ATTACHMENT 1

~ t 1