WASHINGTON PUBLIC POWER SUPPLY SYSTEM P.O. Box 96B

~ 3000 George Washington Way

~ Richland, Washington 99352 February 28, 1991 G02-91-040 Docket No. 50-397 U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Subject:

NUCLEAR PLANT NO. 2, OPERATING LICENSE NPF-21 REQUEST FOR AMENDMENT TO TECHNICAL SPECIFICATIONS SAFETY LIMIT; THERMAL POWER, HIGH PRESSURE AND HIGH FLOW

Reference:

Letter, May 3,
1990, RA Copeland (ANF) to RC Jones (USNRC),

"Transmittal of

'Additional Information on Topical Report ANF-524(P), Revision 2"

In accordance with the Code of Federal Regulations, Title 10, Parts 50.90 and

2. 101, the Supply System hereby requests an amendment to the WNP-2 Technical Specifications.

This amendment is being submitted to allow the use of Cycle 7

reload fuel in WNP-2.

Changes to the following Technical Specifications are being requested.

2.1.2 B2.0 Safety Limits; Thermal

Power, High Pressure and High Flow Safety Limits and Limiting Safety System Settings Attached to this letter are marked-up Technical Specifications (Attachment 1) and Appendix A of the relevant cycle specific document (Attachment 2)generated by the fuel vendor.

As a part of the markup and in keeping with past Supply System

practice, a

brief summary justification of the change requests is attached for clarification and information.

Taken together, this letter and its attachments form the basis for the proposed no significant hazards determination.

Bundle power limits in a boiling water reactor (BWR) are determined through evaluation of critical heat flux phenomena.

The basic criterion used in establishing critical power ratio (CPR) limits is that at least 99.9X of the fuel rods in the core will be expected to avoid boiling transition (critical heat flux) during normal operation and anticipated operational occurrences.

Operating margins are defined by establishing a minimum margin to the onset of boiling transition condition for steady state operation and calculating a

transient effects allowance, thereby assuring that the steady state limit is protected during anticipated off-normal conditions.

This letter addresses establishment of the minimum margin to the steady state boiling transition condition, which is implemented as.the MCPR.,safety'imit in the plant Technical Specifications.

9l03070008 910228 PDR ADOCK 05000397 P

PDR

/

l

~

e

Page Two REQUEST FOR AMENDMENT TO TECHNICAL SPECIFICATIONS SAFETY LIMIT, THERMAL POWER, HIGH PRESSURE AND HIGH FLOW The MCPR safety 1imit is establ ished through stati sti cal consi derati on of measurement and calculational uncertainties associated with the thermal hydraulic state of the reactor using design basis

radial, axial, and local power distributions and considering fuel assembly channel bow.

Some of the calculational uncertai nties, including those introduced by the critical power correlation, power

peaking, and core coolant distribution, are fuel related.

When ANF fuel is introduced into a

core where it will reside with another supplier's fuel

types, the appropriate value of the MCPR safety limit is calculated based on fuel-dependent parameters associated with the mixed core.

Similarly, when an ANF-fabricated reload batch is used to replace a group of dissimilar fuel assemblies, the core average fuel dependent parameters change because of the difference in the relative number of each type of bundle in the

core, and the MCPR safety limit is again reevaluated.

The design basis power distribution is made up of components corresponding to representative radial, axial, and local peaking factors.

Where such data are appropriately available from the previous cycle, these factors are determined through -examination of operating data for the previous cycle and predictions of operating conditions during the cycle being evaluated for the MCPR safety limit.

Available operating data for WNP-2 and the predicted operating conditions for Cycle 7

were evaluated to identify the design basis power distributions for use in the Cycle 7

MCPR safety limit analysis.

A statistical analysis for the number of fuel rods in boiling transition was performed using the methodology described in ANF topical report XN-NF-524(P)(A),

Revision 2

and Supplements, "Exxon Nuclear Critical Power Methodology for Boiling Water Reactors."

With 500 Monte Carlo trials it was determined that for a

minimum CPR value of 1.07 up to 4500 MWD/MTU cycle exposure and

1. 11 from 4500 MWD/MTU cycle exposure to end of cycle, at least 99.9%

of the fuel rods in the core would be expected to avoid boiling transition with a confidence level of 95%.

Therefore, the MCPR safety limits proposed are 1.07. for a cycle exposure up to 4500 MWD/MTU and 1.11 for a cycle exposure greater than 4500 MWD/MTU to EOC.

The effects of channel bow are included in the safety limit MCPR (SLMCPR).

Without channel bow, the SLMCPR would have been 0.03 lower.

The Supply System has reused some initial core channels on fuel assemblies in the WNP-2 Cycle 7

core.

The exposure effects of the reused channel on channel bow was considered in the ANF safety limit MCPR analysis.

The ANF channel data base used in this analysis includes data that corresponds to a channel exposure of approximately 50,000 MWD/MTU (Reference).

I 1

t

Page Three RE(}UEST FOR AMENDMENT TO TECHNICAL SPECIFICATIONS SAFETY LIMIT, THERMAL POWER, HIGH PRESSURE AND HIGH FLOW The Supply System has evaluated this request per 10 CFR 50.92 and determined that it does not:

1.

Involve a significant increase in the probability or consequence of an accident previously evaluated.

A multidiscipline analysis has been performed for the Cycle 7

reload design.

This analysis examines all of the core design changes and their operational impact.

The SLMCPR is established through statistical consideration of measurement and calculational uncertainties associated with the thermal hydraulic state of the reactor.

The SLMCPR as developed determines that at least 99.9X of the fuel rods in the core will be expected to avoid boiling transition during normal and anticipated operational occurrences.

The proposed change in safety limit, analyzed based upon changing core conditions, provides renewed assurance that the above criterion will be met.

Because the above criterion has not changed, establishment of the proposed safety limit change will assure that the probability or consequences of accidents previously analyzed will not change.

2.

3.

Create the possibility of a

new or different kind of acc'ident from any previously evaluated.

The

Cycle, 7

reload design has been analyzed in some detail.

The identification of the need for a change to the SLMCPR does not create a

new type of accident.

The reload design itself is sufficiently similar to the present

design, even considering the fuel design
changes, to preclude the introduction of a new transient.

)

Create a significant reduction in the margin of safety.

The proposed change to the SLMCPR does not create a reduction in the margin of safety.

The purpose of the proposed increase in SLMCPR is to at least preserve the current margin to safety.

Changes in analytical methodology, which because of flatter power distributions increases the population of fuel rods potentially near boiling transition, and direct consideration of potential channel bow associated with extended life fuel channels have identi.fied an increase in SLMCPR.

The proposed SLMCPR increase has been shown to maintain the current margin of safety enjoyed by the WNP-2 core.

As discussed

above, the Supply System considers that this change does not involve a

significant hazard consideration, nor is there a

potential for sufficient change in the types, or significant increase in the amount of any effluents that may be released

offsite, nor does it involve a significant increase in individual or cumulative occupational radiation exposure.

Accordingly, the proposed change meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9) and therefore, per 10 CFR 51.22(b),

an environmental assessment of the change is not required.

0

Page Four RE(VEST FOR AMENDMENT TO TECHNICAL SPECIFICATIONS SAFETY LIMIT, THERMAL POWER, HIGH PRESSURE AND HIGH FLOW This Technical Specification change has been reviewed and approved by the WNP-2 Plant Operations Committee (POC) and the Supply System Corporate Nuclear Safety Review Board (CNSRB).

WNP-2 is currently scheduled to begin the spring outage on April 12, 1991 and resume operation on or about June 1,

1991.

Yery truly yours, G.

C. Sorensen, Manager Regulatory Programs WCW/bw Attachments:

I.

Proposed Technical Specification Changes for Safety Limit, Thermal

Power, High Pressure and High Flow II. ANF-91-01, 2/91, WNP-2 Cycle 7

Plant Transient

Analysis, Appendix A

cc JB Martin -

NRC RV NS Reynolds - Winston 8 Strawn RL Eng NRC DL Williams BPA/399 NRC Site Inspector - 901A RG Waldo -

EFSEC

1

+

a 1

STATE OF WASHINGTON)

)

COUNTY OF BENTON

)

SubjeCt:

Ze dLCIEJ'r RA. @Md~SR>>

7'>. ~4&@ Cider 7~8'~4~

@/Crt I PFJ/Crllfes 4dyO Pig~ +C.cICu I, G. C. SORENSEN, being duly sworn, subscribe to and say that I am the Manager, Regulatory Programs, for the WASHINGTON PUBLIC POWER SUPPLY SYSTEM, the applicant herein; that I have full authority to execute this oath; that I have reviewed the foregoing; and that to the best of my knowledge, information, and belief the statements made in it are true.

DATE:

, 1991 G. C. Sorensen, Manager Regulatory Programs On this date personally appeared before me G. C. SORENSEN, to me known to be the individual who executed the foregoing instrument, and acknowledged that he signed the same as his free act and deed for the uses and purposes herein mentioned.

GIVEN under my hand and seaL this~ day of 1991.

tr ~~

u' Q