L-PI-13-076, Supplement to License Amendment Request for Exception to Technical Specification 5.5.14 Testing Requirements Associated with Steam Generator Replacement

From kanterella
(Redirected from ML13206A313)
Jump to navigation Jump to search

Supplement to License Amendment Request for Exception to Technical Specification 5.5.14 Testing Requirements Associated with Steam Generator Replacement
ML13206A313
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 07/25/2013
From: Jeffery Lynch
Northern States Power Co, Xcel Energy
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
L-PI-13-076, TAC ME9141
Download: ML13206A313 (4)


Text

Xcel Energy July 25, 2013 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Prairie Island Nuclear Generating Plant, Unit 2 Docket 50-306 Renewed License No. DPR-60 Prairie Island Nuclear Generating Plant 1717 Wakonade Drive East Welch, MN 55089 L-PI-13-076 10 CFR 50.90 Supplement to License Amendment Request for Exception to Technical Specification 5.5.14 Testing Requirements Associated With Steam Generator Replacement (TAC No.

ME9141)

In a letter to the U.S. Nuclear Regulatory Commission (NRC) dated July 25, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12207A523), the Northern States Power Company, a Minnesota corporation doing business as Xcel Energy (hereafter "NSPM"), submitted a license amendment request (LAR) to revise Technical Specification (TS) 5.5.14, "Containment Leakage Rate Testing," for Prairie Island Nuclear Generating Plant (PINGP), Unit 2. The proposed change would except PINGP Unit 2 from the requirements of Regulatory Guide (RG) 1.163 as specified in TS 5.5.14 for post-modification containment leakage rate testing associated with steam generator replacement. This exception is being requested to avoid performing an unnecessary integrated leakage rate test (ILRT).

As suggested by NRC Staff, NSPM is enclosing a revised TS markup to clarify that the proposed exception only applies to the upcoming Unit 2 steam generator replacements that are commencing in Fall 2013.

The enclosure to this letter provides the proposed TS change.

NSPM submits this information in accordance with the provisions of 10 CFR 50.90.

The supplemental information provided in this letter does not impact the conclusions of the Determination of No Significant Hazards Consideration and Environmental Assessment presented in the July 25, 2012 submittal.

A copy of this submittal is being forwarded to the designated State of Minnesota official pursuant to 10 CFR 50.91 (b)(1 ).

If there are any questions or if additional information is needed, please contact Glenn Adams at 612-330-6777.

Document Control Desk Page 2 Summary of Commitments This letter contains no new commitments or revisions to existing commitments.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on o7 /:t> /cJo/3

)£~~

~me Lynch Site V e President, Prairie Island Nuclear Generating Plant Northern States Power Company-Minnesota Enclosure cc:

Regional Administrator, Region Ill, USNRC Project Manager, Prairie Island Nuclear Generating Plant, USNRC Resident Inspector, Prairie Island Nuclear Generating Plant, USNRC State of Minnesota

ENCLOSURE Marked-Up Technical Specification Page The enclosed markup illustrates the net changes for the proposed amendment, as applied to the renewed operating license (Unit 1 Amendment 206, Unit 2 Amendment 193).

1 page follows 5.0-28

Programs and Manuals 5.5 5.5 Programs and Manuals (continued) 5.5.14 Containment Leakage Rate Testing Program Prairie Island Units 1 and 2

a.

A program shall be established to implement the leakage rate testing of the containment as required by 10 CPR 50.54(o) and 10 CPR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Pelformance-Based Containment Leak-Test Program," dated September 1995, as modified by the following exceptions:

1.

~~~~~:~u excepted from post-modification integrated leakage rate testing requirements associated with SG&t=ettm generator replacement.

2.

Exception to NEI 94-01, "Industry Guideline for Implementing Pelformance-Based Option of 10 CPR 50, Appendix J", Section 9.2.3, to allow the following:

(i ).

The first Unit 1 Type A test pelformed after December 1, 1997 shall be performed by December 1, 2012.

(ii).

The first Unit 2 Type A test pelformed after March 7, 1997 shall be performed by March 7, 2012.

b.

The peak calculated containment internal pressure for the design basis loss of coolant accident is less than the containment internal design pressure, p a* of 46 psi g.

c.

The maximum allowable primary containment leakage rate, La, at P a.

shall be 0.15% of primary containment air weight per day. For pipes connected to systems that are in the auxiliary building special ventilation zone, the total leakage shall be less than 0.06% of primary containment air weight per day at pressure Pa. For pipes connected to systems that are exterior to both the shield building and the auxiliary building special ventilation zone, the total leakage past isolation valves shall be less than 0.006% of primary containment air weight per day at pressure Pa.

Unit 1 -Amendment No. ~

-1:-+4 206 5.0-28 Unit 2-Amendment No. 164 193