ULNRC-05918 October 15, 2012 Page 1 of 6 Amendment 12, LRA Changes from RAI Responses Summary Table Affected LRA Section LRA Page Table 4.2-3 4.2-5 and 6 Table 4.2-4 4.2-8, 9, and 10

ULNRC-05918 October 15, 2012 Page 2 of 6 Callaway Plant Unit 1 Page 4.2-5 License Renewal Application Amendment 12 Chapter 4 TIME-LIMITED AGING ANALYSES Table 4.2-3 Predicted USE Values at 54 EFPY (EOLE) for Callaway RPV Material Cu (Wt. %)

1/4 T Fluence (n/cm2) (1)

Initial USE (ft - lb)

USE Decrease

(%)

USE (ft-lb)

Reactor Vessel Beltline Materials Intermediate Shell Plate R2707-1 0.05 1.752E19 78 22 61 Intermediate Shell Plate R2707-2 0.06 1.752E19 100 22 78 Intermediate Shell Plate R2707-3 0.06 1.752E19 99 22 77 Lower Shell Plate R2708-1 0.07 1.752E19 82 22 64

- Using Credible Surveillance Data 0.07 1.752E19 82 17 68 Lower Shell Plate R2708-2 0.06 1.752E19 105 22 82 Lower Shell Plate R2708-3 0.08 1.752E19 101 22 79 Intermediate Shell Longitudinal Weld Seams 0.04 1.752E19 143 22 112

- Using Credible Surveillance Data 0.04 1.752E19 143 17 119 Lower Shell Longitudinal Weld Seams 0.04 1.752E19 143 22 112

- Using Credible Surveillance Data 0.04 1.752E19 143 17 119 Intermediate to Lower Shell Circumferential Weld Seam 0.04 1.752E19 112 22 87

- Using Credible Surveillance Data 0.04 1.752E19 112 17 93 Reactor Vessel Extended Beltline Materials Nozzle Shell Plate R2706-1 0.045 4.326E17 102 9.2 93 Nozzle Shell Plate R2706-2 0.055 4.326E17 87 9.2 79 Nozzle Shell Plate R2706-3 0.075 4.326E17 101 9.2 92

ULNRC-05918 October 15, 2012 Page 3 of 6 Callaway Plant Unit 1 Page 4.2-6 License Renewal Application Amendment 12 Chapter 4 TIME-LIMITED AGING ANALYSES Table 4.2-3 Predicted USE Values at 54 EFPY (EOLE) for Callaway RPV Material Cu (Wt. %)

1/4 T Fluence (n/cm2) (1)

Initial USE (ft - lb)

USE Decrease

(%)

USE (ft-lb)

Inlet Nozzle R2702-1 0.1846 0.16 4.326E17 135 14(2) 116 Inlet Nozzle R2702-2 0.1846 0.16 4.326E17 137 14(2) 118 Inlet Nozzle R2702-3 0.1846 0.16 4.326E17 137 14(2) 118 Inlet Nozzle R2702-4 0.1846 0.16 4.326E17 134 14(2) 115 Outlet Nozzle R2703-1 0.1846 0.16 4.326E17 90 14(2) 77 Outlet Nozzle R2703-2 0.1846 0.16 4.326E17 114 14(2) 98 Outlet Nozzle R2703-3 0.1846 0.16 4.326E17 113 14(2) 97 Outlet Nozzle R2703-4 0.1846 0.16 4.326E17 118 14(2) 101 Nozzle Shell to Intermediate Shell Weld Seam 0.04 4.326E17 145 9.2 132 Inlet Nozzle to Shell Weld Seams 0.163 4.326E17 101 17(3) 84 Outlet Nozzle to Shell Weld Seams 0.163 4.326E17 99 17(3) 82 Nozzle Shell Long Weld Seams 0.045 4.326E17 128 9.2 116 1

Fluence values are based on the limiting beltline and extended beltline fluence.

2 The projected USE decreases were calculated in accordance with Position 1.2 of Regulatory Guide 1.99, Revision 2, and were conservatively taken from the base metal 0.20 % copper line in Figure 2 of the Reg. Guide.

3 The projected USE decreases were calculated in accordance with Position 1.2 of Regulatory Guide 1.99, Revision 2, and were conservatively taken from the weld metal 0.20 % copper line in Figure 2 of the Reg. Guide.

ULNRC-05918 October 15, 2012 Page 4 of 6 Callaway Plant Unit 1 Page 4.2-8 License Renewal Application Amendment 12 Chapter 4 TIME-LIMITED AGING ANALYSES Table 4.2-4 Calculation of Callaway Unit 1 RTPTS Values for 54 EFPY (EOLE) at the Clad/Base Metal Interface RPV Material Cu (Wt. %)

Ni (Wt. %)

CF

(ºF)

Fluence (n/cm2) (1)

FF RTNDT(U)

(ºF)

RTNDT

(ºF)

U

(ºF)

D

(ºF)

M

(°F)

RTPTS

(°F)

Reactor Vessel Beltline Materials Intermediate Shell Plate R2707-1 0.05 0.58 31 2.94E19 1.2859 40 39.9 0

17 34 114 Intermediate Shell Plate R2707-2 0.06 0.61 37 2.94E19 1.2859 10 47.6 0

17 34 92 Intermediate Shell Plate R2707-3 0.06 0.62 37 2.94E19 1.2859

-10 47.6 0

17 34 72 Lower Shell Plate R2708-1 0.07 0.58 44 2.94E19 1.2859 50 56.6 0

17 34 141(2)

-Using Credible Surveillance Data 25.6 2.94E19 1.2859 50 32.9 0

8.5 17 100 Lower Shell Plate R2708-2 0.06 0.57 37 2.94E19 1.2859 10 47.6 0

17 34 92 Lower Shell Plate R2708-3 0.08 0.62 51 2.94E19

.2859 20 65.6 0

17 34 120(2)

Intermediate Shell Longitudinal Weld Seams (G2.03) 0.04 0.05 28.8 2.94E19 1.2859

-60 37.0 0

18.5 37 14

-Using Credible Surveillance Data 40.8 2.94E19 1.2859

-60 52.5 0

14 28 20 Lower Shell Longitudinal Weld Seams (G2.03) 0.04 0.05 28.8 2.94E19 1.2859

-60 37 0

18.5 37 14

-Using Credible Surveillance Data 40.8 2.94E19 1.2859

-60 52.5 0

14 28 20 Intermediate to Lower Shell Circumferential Weld Seam (E3.14) 0.04 0.05 28.8 2.94E19 1.2859

-60 37 0

18.5 37 14

ULNRC-05918 October 15, 2012 Page 5 of 6 Callaway Plant Unit 1 Page 4.2-9 License Renewal Application Amendment 12 Chapter 4 TIME-LIMITED AGING ANALYSES Table 4.2-4 Calculation of Callaway Unit 1 RTPTS Values for 54 EFPY (EOLE) at the Clad/Base Metal Interface RPV Material Cu (Wt. %)

Ni (Wt. %)

CF

(ºF)

Fluence (n/cm2) (1)

FF RTNDT(U)

(ºF)

RTNDT

(ºF)

U

(ºF)

D

(ºF)

M

(°F)

RTPTS

(°F)

-Using Credible Surveillance Data 40.8 2.94E19 1.2859

-60 52.5 0

14 28 20 Reactor Vessel Extended Beltline Materials Nozzle Shell Plate R2706-1 0.045 0.615 28.5 7.26E17 0.3559 20 10.1 0

5.1 10.1 40 Nozzle Shell Plate R2706-2 0.055 0.665 34 7.26E17 0.3559 30 12.1 0

6.1 12.1 54 Nozzle Shell Plate R2706-3 0.075 0.6 47.5 7.26E17 0.3559 30 16.9 0

8.5 16.9 64 Inlet Nozzle R2702-1 0.1846 0.16 0.885 146.6 123.9 7.26E17 0.3559 10 52.2 44.1 0

17 34 96.2 88 Inlet Nozzle R2702-2 0.1846 0.16 0.875 146.4 123.8 7.26E17 0.3559 10 52.1 44.1 0

17 34 96.1 88 Inlet Nozzle R2702-3 0.1846 0.16 0.79 144.8 122.8 7.26E17 0.3559

-10 51.5 43.7 0

17 34 75.5 68 Inlet Nozzle R2702-4 0.1846 0.16 0.795 145.0 122.9 7.26E17 0.3559

-10 51.6 43.7 0

17 34 75.6 68 Outlet Nozzle R2703-1 0.1846 0.16 0.64 139.2 119 7.26E17 0.3559

-10 49.5 42.4 0

17 34 73.5 66 Outlet Nozzle R2703-2 0.1846 0.16 0.67 140.3 119.8 7.26E17 0.3559 10 49.9 42.6 0

17 34 93.9 87 Outlet Nozzle R2703-3 0.1846 0.16 0.675 140.5 119.9 7.26E17 0.3559 10 50.0 42.7 0

17 34 94.0 87 Outlet Nozzle R2703-4 0.1846 0.16 0.66 139.9 119.5 7.26E17 0.3559 0

49.8 42.5 0

17 34 83.8 77

ULNRC-05918 October 15, 2012 Page 6 of 6 Callaway Plant Unit 1 Page 4.2-10 License Renewal Application Amendment 12 Chapter 4 TIME-LIMITED AGING ANALYSES Table 4.2-4 Calculation of Callaway Unit 1 RTPTS Values for 54 EFPY (EOLE) at the Clad/Base Metal Interface RPV Material Cu (Wt. %)

Ni (Wt. %)

CF

(ºF)

Fluence (n/cm2) (1)

FF RTNDT(U)

(ºF)

RTNDT

(ºF)

U

(ºF)

D

(ºF)

M

(°F)

RTPTS

(°F)

Nozzle Shell to Intermediate Shell Weld Seam 0.04 1.005 54 7.26E17 0.3559

-60 19.2 0

9.6 19.2

-22 Inlet Nozzle to Shell Weld Seams 0.163 0.035 74.6 7.26E17 0.3559

-40 26.5 0

13.3 26.5 13 Outlet Nozzle to Shell Weld Seams 0.163 0.035 74.6 7.26E17 0.3559

-40 26.5 0

13.3 26.5 13 Nozzle Shell Long Weld Seams 0.035 1.005 47.5 7.26E17 0.3559

-40 16.9 0

8.5 16.9

-6 1

Fluence values are based on the limiting beltline and extended beltline fluence.

2 The limiting RTPTS value for the axially oriented welds and plates is 120°F, which corresponds to the Lower Shell Plate R2708-3. Note that the Lower Shell Plate R2708-1 resulted in a higher RTPTS value of 141°F when the surveillance data was not used; however, the Lower Shell Plate R2708-1 RTPTS value is 100°F when the credible surveillance data was used. Thus, taking credit for the Lower Shell Plate R2708-1 credible surveillance data, the limiting material of the axially oriented welds and plates is the Lower Shell Plate R2708-3.