S

REGULATORY GUI DE

DIRECTORATE OF REGULATORY STANDARDS

REGULATORY GUIDE 6.2 CLASSIFICATION OF UNIRRADIATED PLUTONIUM AND URANIUM SCRAP

A. INTRODUCTION

Methods of Nuclear Materials Control, has developed two standards for the classification of "cold" scrap Part 70 of the Atomic Energy Commission's containing plutonium or uranium. The standard for the regulations requires each licensee to maintain material classification of uranium scrap was approved by ANSI in control and accounting procedures for the special 1970. The standard for the classification of plutonium nuclear material in his possession under license. A key scrap was approved by the ANSI Board of Standards component of such a system is an accurate, measured Review on July 25, 1972.

material balance. A significant factor in obtaining such a material balance is the determination of the quantity of

C. REGULATORY POSITION

nuclear material contained in inventories of heterogeneous scrap. Segregation and identification of The classifications for plutonium and uranium various types and classes of such scrap can materially "cold" scrap contained in the following ANSI standards assist in the determination of the nuclear material are generally acceptable and are sufficiently flexible to contents by providing information necessary for the be applicable to a wide variety of nuclear facilities:

selection of appropriate measurement methods and for the correction of measurement results for such things as ANSI N15.1-1970

impurities, poisons, self-absorption, or Classification of Unirradiated Uranium Scrap.1 self-multiplication. This guide describes acceptable ANSI N15.10-1972 standard classifications for both plutonium and uranium Classification of Unirradiated Plutonium

"cold" scrap to aid in determining material balances.

Scrap.'

B. DISCUSSION

'Copies may be obtained from the American National Subcommittee Nl5.], of the American National Standards Institute, Inc., 1430 Broadway, New York, New York Standards Institute (ANSI) Standards Committee NI5, 10018.

USAEC REGULATORY GUIDES Copies of published guides may be obtained by request indicating the divisions desired to the US. Atomic Energy Commission, Washington, D.C. 20545, Regulatory Guides are issued to describe and make available to the public Attention: Director of Regulatory Standards. Comments and suggestions for methods acceptable to the AEC Regulatory staff of implementing specific parts of Improvements in these guides are encouraged and should be sent to the Secretary the Commission's regulations, to delineate techniques used by the staff in of the Commission, U.S. Atomic Energy Commission, Washington. D.C. 20545, evaluating specific problems or postulated accidents, or to provide guidance to Attention: Chief, Public Proceedings Staff.

applicants. Regulatory Guides are not substitutes for regulations and compliance with them is not required. Methods and solutions different from those set out In The guides are issued in the following ten broad divisions:

the guides will be acceptable if they provide a basis for the findings requisite to the issuance or continuance of a permit or license by the Commission. 1. Power Reactors

6. Products

2. Research and Test Reactors

7. Transportation

3. Fuels and Materials Facilities 8. Occupational Health Published guides will be r pariodicaliy, as appropriate, to accommodate ev.ted 4. Environmental and Siting 9. Antitrust Review comments and to reflect new informatior o, experience. 5. Materials and Plant Protection 10. General