RS-09-063, Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency

From kanterella
(Redirected from ML092380433)
Jump to navigation Jump to search

Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency
ML092380433
Person / Time
Site: LaSalle  
(NPF-011, NPF-018)
Issue date: 05/08/2009
From: Simpson P
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RS-09-063, TAC MD9414, TAC MD9415
Download: ML092380433 (173)


Text

Exelon Nuclear www.exeloncorp.com 4300 Winfield Road Warrenville, IL 60555 RS-09-063 10 CFR 50.90 May 8, 2009 U. S. Nuclear Regulatory Commission ATTN : Document Control Desk Washington, DC 20555-0001 LaSalle County Station, Units 1 and 2 Facility Operating License Nos. NPF-11 and NPF-18 NRC Docket Nos. 50-373 and 50-374 Exelon.

Nuclear

Subject:

Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency References :

1.

Letter from Mr. P. R. Simpson (Exelon Generation Company, LLC) to U. S. NRC, "Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency," dated July 25, 2008 2.

Letter from U. S. NRC to Mr. C. G. Pardee (Exelon Generation Company, LLC), "LaSalle County Station, Units 1 and 2 - Request for Additional Information Related to License Amendment Request to Revise Local Power Range Monitor Calibration Frequency (TAC Nos. MD9414 and MD9415)," dated October 1, 2008

3.

Letter from Mr. P. R. Simpson (Exelon Generation Company, LLC) to U. S. NRC, "Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency," dated October 31, 2008

4.

Letter from Mr. P. R. Simpson (Exelon Generation Company, LLC) to U. S. NRC, "Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency," dated February 17, 2009 In Reference 1, Exelon Generation Company, LLC (EGC) requested an amendment to the facility operating license for LaSalle County Station (LSCS), Units 1 and 2.

Specifically, the proposed changes will revise Technical Specification (TS) 3.3.1.1, "Reactor Protection System (RPS) Instrumentation," Surveillance Requirement (SR) 3.3.1.1.8 and TS 3.3.1.3, "Oscillation Power Range Monitor (OPRM) Instrumentation,"

May 8, 2009 U. S. Nuclear Regulatory Commission Page 2 SR 3.3.1.3.2 to increase the frequency interval between Local Power Range Monitor (LPRM) calibrations from 1000 effective full power hours (EFPH) to 2000 EFPH.

In Reference 2, the NRC requested that EGC provide additional information in support of their review of Reference 1. The response to this NRC request was provided in Reference 3. Following their review of the responses provided in Reference 3, the NRC requested by email that EGC provide additional information to support their review of Reference 1. The response to this request was provided in Reference 4. Based on their review of the responses to these requests, the NRC requested by email, additional clarification of the responses provided in Reference 4. The additional clarification is provided in the attachment to this letter.

EGC has reviewed the information supporting a finding of no significant hazards consideration that was previously provided to the NRC in Reference 1. The additional information provided in this submittal does not affect the bases for concluding that the proposed license amendment does not involve a significant hazards consideration. No new regulatory commitments are established by this submittal.

If you have any questions concerning this letter, please contact Mr. Timothy A. Byam at (630) 657-2804.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 8th day of May 2009.

Patrick R. Simpson Manager - Licensing Exelon Generation Company, LLC

Attachment:

Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency

SRXB-1 ATTACHMENT Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency RAI-1 requested the licensee to provide an uncertainty analysis using decay constants specific to the LPRM detectors at the LSCS. The results should demonstrate that the uncertainties based on a fixed decay factor bound that based on the LPRM specific decay factors for the LSCS. In the response, the licensee did not provide the requested analysis. Instead, it summarized the results of its analysis and indicated that (1) the analysis used in support of the LA R was based on a fixed decay factor of -0.092, which is based on manufacture's data ; and (2) the decay constant used in the CMS will be adjusted to-0

.100 to assure that the evaluated LPRM uncertainty is within the bounds of SLMCPR analysis.

With the results of the analysis with the fixed decay constants of either -0.092 or

-0.100, the NRC staff is not sure whether the results are adequate to represent the actual data with values of the decay constants specific to various LPRM detectors at the LSCS. To resolve this RAI satisfactorily, the licensee should provide a discussion or an analysis (such as the requested detector specific decay constant analysis) to show that the assumption used in the analysis in support of the LA R is valid, i.e., the uncertainties based on a fixed decay factor bound that based on the LPRM specific decay factors for the LSCS.

If the licensee uses an existing analysis to support the RAI response, it should address applicability of the existing analysis to the LAR. The RAI response should identify the effects of any plant specific deviations, such as the LPRM exposure data that may be collected from different models of LPRM detectors, or methods for the uncertainty analysis that may be based on different ranges of the LPRM exposures to represent a nominal exposure value.

Response

The GE Local Power Range Monitor (LPRM) detectors used by Grand Gulf (i.e., NA-250) and used by LaSalle County Station (LSCS) (i.e., NA-300), are regenerative sensors. A regenerative sensor contains U-234 and U-235 in the coated surface. The U-235 absorbs neutrons and produces fission fragments that ionize the gas in the fission chamber. The ionized particles are collected by the sensor electrodes, and produce a detector signal that is proportional to the neutron flux incident on the detector. The fission rate is due primarily to thermal neutron flux, since the product of neutron flux and fission cross section in the thermal region is significantly greater than in the epithermal and fast neutron regions. The U-234 atoms absorb neutrons, become U-235 atoms, and the new U-235 atoms are then available for future fission events. Due to the similarity in the characteristic behavior of the detectors used in Grand Gulf and LSCS, the conclusions presented by Grand Gulf showing the fixed decay constant bounds the specific decay constant is applicable to LSCS.

Previous analysis for Grand Gulf presented results where LPRM calibration currents were based upon LPRM specifically derived calibration curve slopes (Reference 2). This data was presented because this was the method employed in the core monitoring system at Grand Gulf. It was demonstrated that these results were more accurate than the results utilizing a fixed value for the LPRM calibration current slope and therefore provided additional margin (i.e., less uncertainty). LSCS does not utilize LPRM specific Page 1 of 5

ATTACHMENT Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency decay constants so an evaluation of the uncertainties based upon individual LPRM decay constants is not applicable to LSCS.

LPRM calibration data for the NA-300 type LPRMs was collected for both LSCS Units 1 and 2 over a period of several years (Enclosure 1). During this time the core monitoring system (CMS) was accumulating LPRM exposure using the MICROBURN-B (1996 -

2004) or the MICROBURN-B2 (2004 - 2006) LPRM flux calculations. The core monitoring system evaluates the LPRM sensitivity between calibrations based upon this same LPRM flux calculation and a single input value for the variation in sensitivity as a function of LPRM fluence (i.e., exposure). In order to evaluate the uncertainty of this core monitoring system it is necessary to evaluate the variance in the actual and expected LPRM sensitivity. This is the analysis that was presented in the original License Amendment Request (LAR) and following Requests for Additional Information (RAls). In order to project the uncertainty associated with longer calibration intervals, intermediate calibrations were ignored and the projected sensitivity is based upon the calibration one or more calibration steps previous. The projected sensitivity is based upon the single input value for the variation in sensitivity as a function of LPRM fluence.

The measured calibration currents, provided in Enclosure 1, are compared to the vendor supplied logarithmic slope (i.e., -0.092) as well as the average slope determined from the measured data (i.e., -0.100) in Figure SRXB-1.1.

7.5000 7.3000 7.1000 6.9000 6.7000 m 6.5000 0

6.3000 -

y 6.1000 -

U 5.9000 5.7000 -

a U 5.5000 5.3000 -

5.1000 4.9000 4.7000 4.5000 Figure 1. LaSalle Station LPRM Decay Constant 0.0000 5.0000 10.0000 15.0000 20.0000 25.0000 LPRM Exposure (snvt)

This collection of raw calibration currents is not representative of LPRM uncertainties since the LPRM is specifically calibrated for first use and the CMS uses this calibration to project the sensitivity during the interval between that calibration and the next Page 2 of 5 LPRM calibration data

-Measured Decay Constant (-.100)

-Manufacturer Decay Constant (-.092)

z.

SRXB-2 ATTACHMENT Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency calibration. This projection is based upon a constant calibration current below a user defined breakpoint and a user defined logarithmic slope (i.e., decay constant). LSCS provides a single value for the breakpoint and slope for all NA-300 detectors. The error in the LPRM reading just prior to the next calibration is evaluated by comparing the measured calibration current with the projected calibration current at the time of a calibration.

A detailed discussion of the methodology was provided in Reference 1. The LSCS data described above and provided in Enclosure 1 supports using a fixed decay constant of

-0.100. This decay constant was used in the uncertainty analysis and supports the conclusions provided in Reference 1.

In the RAI-2 response, the licensee indicated that it would modify the decay constant to

-0.100 in its CMS so that the evaluated LPRM uncertainty is within the bounds of the SLMCPR analysis.

Discuss adequacy of the use of the LPRM uncertainty in the SLMCPR to bound the evaluated LPRM uncertainty, which is the difference between standard deviations (underlined for emphasis) calculated at two different exposure intervals (i.e., 1000 MWdIMTU and 2675 MWdIMTU). If applicable, clarify that the LPRM uncertainty limit used in the SLMCPR analysis is the maximum value of one standard deviation (which captures 67% of the data points) allowed for the relative LPRM errors. Explain that the LPRM uncertainty limit is appropriately used in the SLMCPR analysis to assure that the determined SLMCPR is the core-wide critical power ratio at which 99.9% (equivalent to more than 3 standard deviations) of the fuel rods would not be expected to experience boiling transition during normal condition.

Response

The Safety Limit Minimum Critical Power Ratio (SLMCPR) uncertainties used to determine LSCS SLMCPR are identified in the methodology provided in AREVA topical report ANF-524(P)(A), Revision 2, (Reference 3) and approved by the NRC in the SER provided on August 8, 1990, (Reference 4). The report includes the MCPR calculational procedure and the system measurement and calculational uncertainties to determine an MCPR safety limit that protects 99.9 percent of the fuel rods from boiling transition. The uncertainties used in AREVA's SLMCPR methodology for LSCS are equivalent to one standard deviation.

The radial bundle power uncertainty being used in the SLMCPR calculations, consistent with the methodology described above, includes the LPRM uncertainty component discussed in the AREVA topical report EMF-2158(P)(A) dated October 1999 (Reference

5). The NRC completed their review of topical report EMF-2158 and documented their approval in the Safety Evaluation dated October 18, 1999 (Reference 6). As documented in Reference 5, Equations 9-12 and 9-13 incorporate the LPRM measurement uncertainty into the radial bundle power measurement uncertainty. The Page 3 of 5

SRXB-3 Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency radial bundle power uncertainty value currently being used in the SLMCPR analysis for LSCS utilizes an LPRM uncertainty of 4.3% (i.e., a conservative value for the 2500 EFPH recalibration interval) in lieu of 3.4% for 1000 EFPH.

Identify the name of the simulator (or computer code) if it has one, and discuss acceptability of the simulator used for determination of accumulated exposure values. If the simulator was previously approved by the NRC, reference the title and the date of the safety evaluation report that approved the simulator for licensing applications.

Response

ATTACHMENT In the RAl-3 response, the licensee indicated that a 3D nodal simulator was used to calculate the accumulated exposure values.

Since 1996 EGC has used two different software packages for core monitoring at LSCS.

LSCS has used POWERPLEX-II and POWERPLEX-III.

POWERPLEX-II is a software package developed by AREVA for core monitoring tasks in BWR plants. The accumulated exposure values in POWERPLEX-II are performed by the calculation engine (or code) MICROBURN-B in accordance with XN-NF-80-19(P)(A),

Volume 1, Supplements 3 and 4, dated November 1990 (Reference 7). This report was reviewed and approved by the NRC in the Safety Evaluation dated August 13, 1990 (Reference 8).

POWERPLEX-III is a software package developed by AREVA for core monitoring tasks in BWR plants. The accumulated exposure values in POWERPLEX-III are performed by the calculation engine (or code) MICROBURN-B2 in accordance with EMF-2158(P)(A),

dated October 1999 (Reference 5) as reviewed and approved by the NRC in the Safety Evaluation dated October 18, 1999 (Reference 6).

References :

1.

Letter from Mr. P. R. Simpson (Exelon Generation Company, LLC) to U.S. NRC, "Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency," dated October 31, 2008 2.

Letter from W. R. Brian (Entergy Operations, Inc.) to U.S. NRC, "License Amendment Request Changes to the Local Power Range Monitor (LPRM)

Calibration Frequency," dated November 1, 2006

3. AREVA Topical Report ANF-524(P)(A), "Advanced Nuclear Fuel Corporation Critical Power Methodology for Boiling Water Reactors," Revision 2, dated November 1990

ATTACHMENT Additional Information Supporting the Request for a License Amendment to Revise Local Power Range Monitor Calibration Frequency

4.

Letter from A. C. Thadani (NRC) to R. A. Copeland (ANF), "Acceptance for Referencing of Topical Report ANF-524(P), Revision 2, ANF Critical Power Methodology for Boiling Water Reactors," dated August 8, 1990

5. Siemens Topical Report EMF-2158(P)(A), "Siemens Power Corporation Methodology for Boiling Water Reactors : Evaluation and Validation of CASMO-4/MICROBURN-B2," dated October 1999 6.

Letter from Stephen Dembeck (U.S. NRC) to J. F. Mallay (Siemens Power Corporation), "Acceptance for Referencing of Licensing Topical Report EMF-2158(P), Revision 0, 'Siemens Power Corporation Methodology for Boiling Water Reactors : Evaluation and Validation of CASMO-4/MICROBURN-B2' (TAC No.

MA4592)," dated October 18, 1999

7. Advanced Nuclear Fuels Topical Report XN-NF-80-19(P)(A), Volume 1, Supplements 3 and 4, "Advanced Nuclear Fuels Corporation Methodology for Boiling Water Reactors : Benchmark Results for the CASMO-3G/MICROBURN-B Calculation Methodology," dated November 1990
8. Letter from Stephen Dembeck (U.S. NRC) to R. A. Copeland (Advanced Nuclear Fuels Corporation), "Acceptance for Referencing of Licensing Topical Report XN-NF-80-19(P) Volume 1, Supplement 3, Revision 0, 'Advanced Nuclear Fuels Corporation Methodology for Boiling Water Reactors : Benchmark Results for the CASMO-3G/MICROBURN-B Calculation Methodology,"' dated August 13, 1990

ENCLOSURE1 LaSalle County Station Units 1 and 2 Local Power Range Monitor (LPRM) Calibration Data

LaSalle County Station Unit 1

LaSalle Unit 1 LPRM Data Printed: 11/22(2006 String No.: 1 Serial No. : L-2693 Cycle Installed:

6 Coordinates:

Level:

57 A

Type :

LPRM ID No. :

NA300 44 Cumulative Core Beginning Average Exposure at BOC :

of Life Calibration Current:

86,992 1,289.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Life Good Date CAVEX Exp GAF GAFpost Corrected CalCur In(CalCur)

Byp.?

Value 6/7/2001 46,317 5.206 1.459 0.000 No 650.0 6.5 No Yes 7/7/2001 47,088 5.341 1.052 0.000 No 617.9 6.4 No Yes 9/13/2001 48,853 5.687 1.057 0.000 No 584.6 6.4 No Yes 3/29/2002 50,962 6.333 1.074 0.000 No 544.3 6.3 No Yes 1/16/2003 55,612 7.492 1.063 0.000 No 512.0 6.2 No Yes 7/30/2003 60,484 8.442 1.054 0.000 No 485.8 6.2 No Yes 3/25/2004 69,535 9.087 1.059 0.000 No 458.7 6.1 No Yes 5/6/2004 70,615 9208 0.949 0.000 No 483.4 6.2 No Yes 7/15/2004 72,392 9.411 1.061 0.000 No 455.6 6.1 No Yes 1/6/2005 76,871 9.910 0.912 0.000 No 499.5 6.2 No Yes 4/21/2005 79,565 10.147 1.070 0.000 No 466.9 6.1 No Yes 9/15/2005 83,306 10.536 0.943 0.000 No 495.1 6.2 No Yes 10/20/2005 84,207 10.596 0.948 0.000 No 522.0 6.3 No Yes 3/24/2006 87,119 10.838 1.154 0.000 No 452.3 6.1 No Yes 10/26/2006 92,606 11.493 0.994 0.000 No 455.1 6.1 No Yes Level: B LPRM ID No. : 130 Beginning of Life Calibration Current:

1,281.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp ?

Value 9/12/1996 21,038 2.398 1.047 0.000 Yes 969.0 6.9 No Yes 8/25/1998 22,612 2.495 1.060 0.000 No 914.2 6.8 No Yes 9/29/1998 23,473 2.648 0.992 0.000 No 921.5 6.8 No Yes 3/11/1999 27,265 3.306 1.086 0.000 No 846.0 6.7 No Yes 6/24/1999 29,696 3.690 1.069 0.000 No 791.4 6.7 No Yes 11/24/1999 32,205 4.029 1.081 0.000 No 732.1 6.6 No Yes 2/2/2000 33,916 4.333 1.061 0.000 No 690.0 6.5 No Yes 6/14/2000 37,221 4.941 1.051 0.000 No 656.5 6.5 No Yes 9/28/2000 39,966 5.467 1.050 0.000 No 625.3 6.4 No Yes 1/18/2001 42,777 6.010 1.057 0.000 No 591.5 6.4 No Yes 6/7/2001 46,317 6.684 1.059 0.000 No 558.6 6.3 No Yes 7/7/2001 47,088 6.830 1.098 0.000 No 508.7 6.2 No Yes 3/29/2002 50,962 7.946 1.084 0.000 No 469.3 6.2 No Yes

Level: C LPRM ID No. : 216 Beginning of Life Calibration Current:

1,371.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 2.900 1.016 0.000 Yes 1,201.0 7.1 No Yes 8/25/1998 22,612 2.954 1.066 0.000 No 1,126.6 7.0 No Yes 9/29/1998 23,473 3.078 0.992 0.000 No 1,135.7 7.0 No Yes 4/15/1999 28,093 3.770 1.052 0.000 No 1,079.6 7.0 No Yes 11/24/1999 32,205 4.436 1.106 0.000 No 976.1 6.9 No Yes 4/12/2000 35,637 4.942 1.070 0.000 No 912.3 6.8 No Yes 5/10/2000 36,328 5.039 1.002 0.000 No 910.4 6.8 No Yes 7/7/2001 47,088 6.755 1.102 0.000 No 827.8 6.7 No Yes 6/6/2002 49,915 7.963 1.002 0.000 No 780.0 6.7 No Yes 3/29/2002 50,962 7.777 1.055 0.000 No 784.7 6.7 No Yes 12/5/2002 54,558 8.556 1.053 0.000 No 740.7 6.6 No Yes 7/30/2003 60,484 9.356 1.064 0.000 No 696.2 6.5 No Yes 11/20/2003 63,386 9.855 1.056 0.000 No 659.3 6.5 No Yes 2/19/2004 68,646 10.133 1.061 0.000 No 621.4 6.4 No Yes 6/17/2004 71,692 10.577 1.082 0.000 No 574.3 6.4 No Yes 12/9/2004 76,150 11.247 1.070 0.000 No 536.7 6.3 No Yes 8/4/2005 82,243 12.084 1.052 0.000 No 510.2 6.2 No Yes 1/12/2006 86,332 12.709 1.051 0.000 No 485.4 6.2 No Yes 10/26/2006 92,606 13.622 1.046 0.000 No 464.1 6.1 No Yes Level: D LPRM ID No. : 302 Beginning of Life Calibration Current:

1,300.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 2.554 1.051 0.000 Yes 988.0 6.9 No Yes 8/25/1998 22,612 2.573 1.027 0.000 No 962.0 6.9 No Yes 9/29/1998 23,473 2.647 0.999 0.000 No 963.0 6.9 No Yes 3/11/1999 27,265 3.014 1.061 0.000 No 908.0 6.8 No Yes 11/24/1999 32,205 3.602 1.128 0.000 No 805.0 6.7 No Yes 1/16/2003 55,612 9.361 1.079 0.000 No 434.9 6.1 No Yes 7/30/2003 60,484 10.327 1.045 0.000 No 435.0 6.1 No Yes 10/16/2003 62,481 10.693 1.063 0.000 No 409.2 6.0 No Yes 2/19/2004 68,646 11.082 1.069 0.000 No 382.8 5.9 No Yes 6/17/2004 71,692 11.542 1.074 0.000 No 356.4 5.9 No Yes 6/8/2006 89,031 13.743 1.071 0.000 No 332.8 5.8 No Yes 10/26/2006 92,606 14.267 1.018 0.000 No 326.9 5.8 No Yes

String No. : 2 Serial No.: K-7089 Cycle Installed:

7 Coordinates:

Level:

57 A

Type:

LPRM ID No.:

NA300 45 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current :

79,343 1,426.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 2.344 1.035 0.000 Yes 1,194.0 7.1 No Yes 8/25/1998 14,963 2.461 1.095 0.000 No 1,090.4 7.0 No Yes 9/29/1998 15,824 2.613 1.007 0.000 No 1,082.8 7.0 No Yes 2/4/1999 18,757 3.087 1.061 0.000 No 1,020.6 6.9 No Yes 11/24/1999 24,556 3.937 1.080 0.000 No 945.0 6.9 No Yes 11/30/1999 24,692 3.963 1.053 0.000 No 897.4 6.8 No Yes 6/14/2000 29,572 4.933 1.062 0.000 No 845.0 6.7 No Yes 9/28/2000 32,317 5.526 1.104 0.000 No 765.4 6.6 No Yes 2/22/2001 35,949 6.438 1.073 0.000 No 713.3 6.6 No Yes 6/7/2001 38,668 6.961 1.082 0.000 No 659.3 6.5 No Yes 2/14/2002 42,230 8.191 1.052 0.000 No 587.9 6.4 No Yes 3/29/2002 43,313 8.431 1.073 0.000 No 547.9 6.3 No Yes 12/20/2001 43,726 8.061 1.066 0.000 No 618.5 6.4 No Yes 9/19/2002 44,942 9.396 1.081 0.000 No 506.8 6.2 No Yes 4/10/2003 50,087 10.676 1.060 0.000 No 478.2 6.2 No Yes 7/30/2003 52,835 11.571 1.066 0.000 No 448.6 6.1 No Yes 10/16/2003 54,832 12.134 1.061 0.000 No 422.8 6.0 No Yes 2/19/2004 60,997 12.618 1.078 0.000 No 392.2 6.0 No Yes 4/12/2000 35,637 3.869 1.054 0.000 No 763.7 6.6 No Yes 1/18/2001 42,777 4.522 1.059 0.000 No 721.2 6.6 No Yes 7/7/2001 47,088 5.006 1.051 0.000 No 686.2 6.5 No Yes 10/18/2001 49,756 5.337 1.055 0.000 No 650.4 6.5 No Yes 3/25/2004 69,535 6.841 0.927 0.000 No 701.6 6.6 No Yes 5/6/2004 70,615 6.929 1.146 0.000 No 612.2 6.4 No Yes 7/15/2004 72,392 7.092 0.941 0.000 No 650.6 6.5 No Yes 8/12/2004 73,112 7.164 1.066 0.000 No 610.3 6.4 No Yes 2/3/2005 77,588 7.665 1.051 0.000 No 580.7 6.4 No Yes 12/1/2005 85,259 8.717 1.063 0.000 No 546.3 6.3 No Yes 3/24/2006 87,119 9.061 0.932 0.000 No 586.2 6.4 No Yes 6/8/2006 89,031 9.268 1.066 0.000 No 549.9 6.3 No Yes 10/26/2006 92,606 9.723 1.001 0.000 No 549.3 6.3 No Yes

7/15/2004 64,743 13.351 1.086 0.000 No 361.1 5.9 No Yes 10/28/2004 67,434 14.000 1.062 0.000 No 340.0 5.8 No Yes 1/6/2005 69,222 14.373 0.942 0.000 No 361.0 5.9 No Yes 4/21/2005 71,916 14.976 1.089 0.000 No 331.5 5.8 No Yes 8/4/2005 74,594 15.584 1.056 0.000 No 313.9 5.7 No Yes 12/1/2005 77,610 16.132 0.940 0.000 No 333.9 5.8 No Yes 3/24/2006 79,470 16.435 1.116 0.000 No 299.2 5.7 No Yes 5/4/2006 80,518 16.705 1.112 0.000 No 269.1 5.6 No Yes 8/17/2006 83,172 17.216 0.926 0.000 No 290.6 5.7 No Yes 9/21/2006 84,063 17.395 1.097 0.000 No 264.9 5.6 No Yes 10/26/2006 84,957 17.592 1.006 0.000 No 263.3 5.6 No Yes Level : B LPRM ID No. : 131 Beginning of Life Calibration Current :

1,445.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 3.144 1.065 0.000 Yes 1,137.0 7.0 No Yes 8/25/1998 14,963 3.262 1.077 0.000 No 1,055.7 7.0 No Yes 9/29/1998 15,824 3.463 1.016 0.000 No 1,039.1 6.9 No Yes 2/4/1999 18,757 4.133 1.098 0.000 No 946.3 6.9 No Yes 3/11/1999 19,616 4.312 1.053 0.000 No 904.0 6.8 No Yes 6/24/1999 22,047 4.796 1.060 0.000 No 852.8 6.7 No Yes 11/24/1999 24,556 5.225 1.104 0.000 No 772.5 6.6 No Yes 2/2/2000 26,267 5.589 1.061 0.000 No 728.1 6.6 No Yes 5/10/2000 28,679 6.121 1.057 0.000 No 688.8 6.5 No Yes 7/20/2000 30,502 6.528 1.080 0.000 No 637.8 6.5 No Yes 1/18/2001 35,128 7.576 1.072 0.000 No 595.0 6.4 No Yes 3/22/2001 36,674 7.884 1.056 0.000 No 563.4 6.3 No Yes 6/7/2001 38,668 8.271 1.058 0.000 No 532.5 6.3 No Yes 10/18/2001 42,107 9.018 1.090 0.000 No 488.5 6.2 No Yes 2/14/2002 42,230 9.536 1.121 0.000 No 435.8 6.1 No Yes 8/15/2002 44,072 10.589 1.084 0.000 No 402.0 6.0 No Yes 4/10/2003 50,087 12.081 1.052 0.000 No 382.2 5.9 No Yes 7/30/2003 52,835 12.783 1.057 0.000 No 361.6 5.9 No Yes 11/20/2003 55,737 13.512 1.061 0.000 No 340.8 5.8 No Yes 2/19/2004 60,997 13.845 1.065 0.000 No 320.0 5.8 No Yes 7/15/2004 64,743 14.634 1.076 0.000 No 297.4 5.7 No Yes 2/3/2005 69,939 15.744 1.059 0.000 No 280.8 5.6 No Yes 5/31/2005 72,935 16.382 1.053 0.000 No 266.7 5.6 No Yes

10/20/2005 3/24/2006 7/13/2006 10/26/2006 76,558 79,470 82,276 84,957 17.128 17.801 18.434 19.016 1.066 1.238 1.053 1.005 0.000 0.000 0.000 0.000 No No No No 250.0 201.9 191.8 190.8 5.5 5.3 5.3 5.3 No No No No Yes Yes Yes Yes Level : C LPRM ID No. : 217 Beginning of Life Calibration Current:

1,411.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 3.129 1.043 0.000 Yes 1,173.0 7.1 No Yes 8/25/1998 14,963 3.208 1.104 0.000 No 1,062.5 7.0 No Yes 9/29/1998 15,824 3.368 1.022 0.000 No 1,039.6 6.9 No Yes 2/4/1999 18,757 3.939 1.081 0.000 No 961.7 6.9 No Yes 4/15/1999 20,444 4.276 1.062 0.000 No 905.6 6.8 No Yes 8/4/1999 22,908 4.775 1.076 0.000 No 841.6 6.7 No Yes 11/24/1999 24,556 5.125 1.141 0.000 No 737.6 6.6 No Yes 2/2/2000 26,267 5.409 1.081 0.000 No 682.3 6.5 No Yes 6/14/2000 29,572 5.943 1.065 0.000 No 640.7 6.5 No Yes 11/4/2000 33,192 6.567 1.055 0.000 No 607.3 6.4 No Yes 2/22/2001 35,949 7.093 1.064 0.000 No 570.8 6.3 No Yes 8/17/2001 40,505 8.125 1.055 0.000 No 541.0 6.3 No Yes 10/18/2001 42,107 8.478 1.052 0.000 No 514.3 6.2 No Yes 2/14/2002 42,230 8.976 1.108 0.000 No 464.1 6.1 No Yes 6/19/2003 51,771 10.804 1.057 0.000 No 439.1 6.1 No Yes 7/30/2003 52,835 11.007 1.022 0.000 No 439.0 6.1 No Yes 11/20/2003 55,737 11.635 1.063 0.000 No 413.0 6.0 No Yes 2/19/2004 60,997 11.988 1.063 0.000 No 388.5 6.0 No Yes 6/17/2004 64,043 12.516 1.073 0.000 No 362.1 5.9 No Yes 12/9/2004 68,501 13.346 1.077 0.000 No 336.2 5.8 No Yes 8/4/2005 74,594 14.506 1.089 0.000 No 308.7 5.7 No Yes 1/12/2006 78,683 15.419 1.083 0.000 No 285.1 5.7 No Yes 3/24/2006 79,470 15.665 1.125 0.000 No 253.4 5.5 No Yes 9/21/2006 84,063 16.540 1.051 0.000 No 241.1 5.5 No Yes 10/26/2006 84,957 16.710 0.996 0.000 No 242.1 5.5 No Yes Level : D LPRM ID No. : 303 Beginning of Life Calibration Current:

1,384.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 2.289 1.018 0.000 Yes 1,387.0 7.2 No Yes 8/25/1998 14,963 2.314 1.049 0.000 No 1,322.2 7.2 No Yes

9/29/1998 15,824 2.414 1.007 0.000 No 1,313.0 7.2 No Yes 3/11/1999 19,616 2.909 1.055 0.000 No 1,239.0 7.1 No Yes 11/24/1999 24,556 3.697 1.121 0.000 No 1,105.3 7.0 No Yes 7/20/2000 30,502 4.250 1.071 0.000 No 1,032.0 6.9 No Yes 10/18/2001 42,107 5.798 1.063 0.000 No 970.8 6.9 No Yes 2/14/2002 42,230 6.166 1.159 0.000 No 837.6 6.7 No Yes 4/10/2003 50,087 6.752 0.948 0.000 No 883.6 6.8 No Yes 6/19/2003 51,771 6.869 1.058 0.000 No 835.2 6.7 No Yes 7/30/2003 52,835 6.959 1.008 0.000 No 835.0 6.7 No Yes 6/17/2004 64,043 7.758 1.086 0.000 No 768.9 6.6 No Yes 8/12/2004 65,463 7.916 1.062 0.000 No 724.0 6.6 No Yes 10/28/2004 67,434 8.150 0.935 0.000 No 774.3 6.7 No Yes 12/9/2004 68,501 8.290 1.073 0.000 No 721.6 6.6 No Yes 5/31/2005 72,935 8.995 1.084 0.000 No 665.7 6.5 No Yes 12/1/2005 77,610 9.850 1.096 0.000 No 607.4 6.4 No Yes 3/24/2006 79,470 10.318 1.171 0.000 No 518.7 6.3 No Yes 5/4/2006 80,518 10.450 0.923 0.000 No 562.0 6.3 No Yes 6/8/2006 81,382 10.578 1.081 0.000 No 519.9 6.3 No Yes 8/17/2006 83,172 10.895 1.069 0.000 No 486.3 6.2 No Yes 9/21/2006 84,063 11.048 0.932 0.000 No 521.8 6.3 No Yes 10/26/2006 84,957 11.193 1.001 0.000 No 521.3 6.3 No Yes String No.: 3 Serial No.: L-2689 Cycle Installed:

6 Coordinates: 57 Type : NA300 Cumulative Core Average Exposure at BOC:

86,992 Level: A LPRM ID No. : 46 Beginning of Life Calibration Current:

1,345.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp ?

Value 9/12/1996 21,038 3.537 1.064 0.000 Yes 759.0 6.6 No Yes 8/25/1998 22,612 3.638 1.025 0.000 No 740.5 6.6 No Yes 9/29/1998 23,473 3.786 1.041 0.000 No 711.3 6.6 No Yes 2/4/1999 26,406 4.241 1.063 0.000 No 669.2 6.5 No Yes 6/24/1999 29,696 4.744 1.057 0.000 No 633.1 6.5 No Yes 11/24/1999 32,205 5.080 1.087 0.000 No 582.4 6.4 No Yes 12/27/1999 33,008 5.230 1.090 0.000 No 534.3 6.3 No Yes 8/24/2000 39,057 6.471 1.073 0.000 No 498.0 6.2 No Yes 2/22/2001 43,598 7.507 1.102 0.000 No 451.9 6.1 No Yes 2/14/2002 49,879 9.182 1.051 0.000 No 407.2 6.0 No Yes

12/20/2001 51,375 9.044 1.056 0.000 No 427.9 6.1 No Yes 8/15/2002 51,721 10.204 1.062 0.000 No 383.4 5.9 No Yes 6/19/2003 59,420 12.050 1.059 0.000 No 362.0 5.9 No Yes 7/30/2003 60,484 12.373 1.033 0.000 No 362.0 5.9 No Yes 10/16/2003 62,481 12.948 1.077 0.000 No 336.1 5.8 No Yes 2/19/2004 68,646 13.447 1.150 0.000 No 292.3 5.7 No Yes 3/25/2004 69,535 13.646 0.900 0.000 No 324.8 5.8 No Yes 6/17/2004 71,692 14.111 1.149 0.000 No 282.6 5.6 No Yes 8/12/2004 73,112 14.391 0.916 0.000 No 308.6 5.7 No Yes 10/28/2004 75,083 14.848 1.101 0.000 No 280.3 5.6 No Yes 12/9/2004 76,150 15.109 1.051 0.000 No 266.7 5.6 No Yes 1/6/2005 76,871 15.252 0.894 0.000 No 298.3 5.7 No Yes 2/3/2005 77,588 15.398 1.115 0.000 No 267.5 5.6 No Yes 8/4/2005 82,243 16.446 0.936 0.000 No 285.8 5.7 No Yes 9/15/2005 83,306 16.624 1.135 0.000 No 251.8 5.5 No Yes 1/12/2006 86,332 17.176 0.912 0.000 No 276.1 5.6 No Yes 3/24/2006 87,119 17.336 1.216 0.000 No 227.1 5.4 No Yes 10/26/2006 92,606 18.373 1.034 0.000 No 219.6 5.4 No Yes Level: B LPRM ID No. : 132 Beginning of Life Calibration Current:

1,365.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 4.568 1.066 0.000 Yes 721.0 6.6 No Yes 8/25/1998 22,612 4.681 1.042 0.000 No 691.9 6.5 No Yes 9/29/1998 23,473 4.883 1.034 0.000 No 669.2 6.5 No Yes 2/4/1999 26,406 5.541 1.095 0.000 No 611.1 6.4 No Yes 6/24/1999 29,696 6.175 1.086 0.000 No 562.7 6.3 No Yes 11/24/1999 32,205 6.632 1.106 0.000 No 508.8 6.2 No Yes 3/8/2000 34,776 7.206 1.058 0.000 No 480.9 6.2 No Yes 7/20/2000 38,151 7.993 1.050 0.000 No 458.0 6.1 No Yes 9/28/2000 39,966 8.362 1.053 0.000 No 435.0 6.1 No Yes 4/26/2001 45,228 9.514 1.071 0.000 No 406.1 6.0 No Yes 10/18/2001 49,756 10.417 1.085 0.000 No 374.3 5.9 No Yes 2/14/2002 49,879 10.955 1.089 0.000 No 343.7 5.8 No Yes 12/5/2002 54,558 12.711 1.060 0.000 No 324.3 5.8 No Yes 5/15/2003 58,582 13.609 1.058 0.000 No 306.5 5.7 No Yes 7/30/2003 60,484 14.092 1.020 0.000 No 306.0 5.7 No Yes 11/20/2003 63,386 14.819 1.063 0.000 No 287.9 5.7 No Yes

Level: C LPRM ID No.: 218 Beginning of Life Calibration Current :

1,325.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 4.587 1.081 0.000 Yes 656.0 6.5 No Yes 8/25/1998 22,612 4.666 1.048 0.000 No 626.0 6.4 No Yes 9/29/1998 23,473 4.827 1.018 0.000 No 614.9 6.4 No Yes 2/4/1999 26,406 5.423 1.058 0.000 No 581.2 6.4 No Yes 6/24/1999 29,696 6.123 1.084 0.000 No 536.1 6.3 No Yes 11/24/1999 32,205 6.666 1.144 0.000 No 468.7 6.1 No Yes 3/8/2000 34,776 7.096 1.057 0.000 No 443.4 6.1 No Yes 1/18/2001 42,777 8.519 1.059 0.000 No 418.7 6.0 No Yes 6/7/2001 46,317 9.300 1.060 0.000 No 395.0 6.0 No Yes 2/14/2002 49,879 10.541 1.061 0.000 No 353.9 5.9 No Yes 11/15/2001 50,480 10.191 1.052 0.000 No 375.5 5.9 No Yes 5/15/2003 58,582 12.191 1.064 0.000 No 332.6 5.8 No Yes 7/30/2003 60,484 12.545 1.005 0.000 No 333.0 5.8 No Yes 11/20/2003 63,386 13.176 1.059 0.000 No 314.4 5.8 No Yes 2/19/2004 68,646 13.529 1.082 0.000 No 290.6 5.7 No Yes 7/15/2004 72,392 14.174 1.056 0.000 No 275.2 5.6 No Yes 12/9/2004 76,150 14.852 1.077 0.000 No 255.5 5.5 No Yes 9/15/2005 83,306 16.143 1.054 0.000 No 242.4 5.5 No Yes 3/24/2006 87,119 17.108 1.141 0.000 No 212.5 5.4 No Yes 7/13/2006 89,925 17.657 1.068 0.000 No 198.9 5.3 No Yes 10/26/2006 92,606 18.179 1.009 0.000 No 197.2 5.3 No Yes Level: D LPRM ID No. : 304 Beginning of Life Calibration Current:

1,362.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 3.473 1.060 0.000 Yes 883.0 6.8 No Yes 8/25/1998 22,612 3.499 1.057 0.000 No 835.4 6.7 No Yes 9/29/1998 23,473 3.599 0.999 0.000 No 836.2 6.7 No Yes 2/19/2004 68,646 15.154 1.150 0.000 No 250.3 5.5 No Yes 8/12/2004 73,112 16.110 1.052 0.000 No 237.9 5.5 No Yes 12/9/2004 76,150 16.770 1.051 0.000 No 226.4 5.4 No Yes 10/20/2005 84,207 18.336 1.060 0.000 No 214.0 5.4 No Yes 3/24/2006 87,119 19.023 1.143 0.000 No 187.2 5.2 No Yes 9/21/2006 91,712 20.008 1.072 0.000 No 174.7 5.2 No Yes 10/26/2006 92,606 20.207 0.977 0.000 No 178.8 5.2 No Yes

2/4/1999 26,406 3.986 1.062 0.000 No 787.4 6.7 No Yes 6/24/1999 29,696 4.463 1.070 0.000 No 735.9 6.6 No Yes 11/24/1999 32,205 4.911 1.127 0.000 No 653.0 6.5 No Yes 2/2/2000 33,916 5.073 1.070 0.000 No 610.2 6.4 No Yes 9/28/2000 39,966 5.681 1.065 0.000 No 573.0 6.4 No Yes 2/14/2002 49,879 7.478 1.085 0.000 No 528.1 6.3 No Yes 6/19/2003 59,420 8.203 0.929 0.000 No 568.5 6.3 No Yes 7/30/2003 60,484 8.297 1.004 0.000 No 568.0 6.3 No Yes 3/25/2004 69,535 8.872 1.124 0.000 No 505.3 6.2 No Yes 6/17/2004 71,692 9.068 0.916 0.000 No 551.7 6.3 No Yes 8/12/2004 73,112 9.220 1.104 0.000 No 499.7 6.2 No Yes 10/28/2004 75,083 9.445 0.948 0.000 No 527.1 6.3 No Yes 1/6/2005 76,871 9.688 1.081 0.000 No 487.6 6.2 No Yes 2/3/2005 77,588 9.801 0.949 0.000 No 513.8 6.2 No Yes 8/4/2005 82,243 10.431 1.119 0.000 No 459.2 6.1 No Yes 9/15/2005 83,306 10.598 0.927 0.000 No 495.3 6.2 No Yes 1/12/2006 86,332 11.189 1.132 0.000 No 437.6 6.1 No Yes 5/4/2006 88,167 11.558 1.078 0.000 No 405.9 6.0 No Yes 7/13/2006 89,925 11.868 1.091 0.000 No 372.1 5.9 No Yes 10/26/2006 92,606 12.366 0.962 0.000 No 386.8 6.0 No Yes String No.: 4 Serial No.: K-7091 Cycle Installed:

7 Coordinates: 57 Type: NA300 Cumulative Core Average Exposure at BOC:

79,343 Level: A LPRM ID No.: 47 Beginning of Life Calibration Current :

1,232.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 1.880 1.046 0.000 Yes 1,170.0 7.1 No Yes 8/25/1998 14,963 1.982 1.087 0.000 No 1,076.4 7.0 No Yes 9/29/1998 15,824 2.114 1.026 0.000 No 1,049.1 7.0 No Yes 3/11/1999 19,616 2.640 1.065 0.000 No 980.0 6.9 No Yes 6/24/1999 22,047 3.002 1.055 0.000 No 928.9 6.8 No Yes 11/24/1999 24,556 3.283 1.111 0.000 No 836.1 6.7 No Yes 12/27/1999 25,359 3.416 1.059 0.000 No 789.5 6.7 No Yes 4/12/2000 27,988 3.864 1.061 0.000 No 744.1 6.6 No Yes 8/24/2000 31,408 4.530 1.075 0.000 No 692.2 6.5 No Yes 9/28/2000 32,317 4.678 1.050 0.000 No 659.3 6.5 No Yes 1/18/2001 35,128 5.258 1.060 0.000 No 621.9 6.4 No Yes

Level: B LPRM ID No.: 133 Beginning of Life Calibration Current :

1,299.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 2.568 1.043 0.000 Yes 1,185.0 7.1 No Yes 8/25/1998 14,963 2.674 1.071 0.000 No 1,106.4 7.0 No Yes 9/29/1998 15,824 2.859 1.014 0.000 No 1,091.2 7.0 No Yes 3/11/1999 19,616 3.640 1.068 0.000 No 1,020.0 6.9 No Yes 6/24/1999 22,047 4.081 1.068 0.000 No 955.1 6.9 No Yes 11/24/1999 24,556 4.466 1.088 0.000 No 877.8 6.8 No Yes 3/8/2000 27,127 4.984 1.079 0.000 No 813.5 6.7 No Yes 7/20/2000 30,502 5.675 1.073 0.000 No 758.2 6.6 No Yes 12/7/2000 34,042 6.407 1.060 0.000 No 715.3 6.6 No Yes 3/22/2001 36,674 6.927 1.057 0.000 No 676.7 6.5 No Yes 6/7/2001 38,668 7.285 1.073 0.000 No 630.7 6.4 No Yes 9/13/2001 41,204 7.808 1.053 0.000 No 598.9 6.4 No Yes 2/14/2002 42,230 8.485 1.119 0.000 No 535.2 6.3 No Yes 6/6/2002 42,266 9.082 1.055 0.000 No 507.3 6.2 No Yes 9/19/2002 44,942 9.701 1.060 0.000 No 478.6 6.2 No Yes 4/10/2003 50,087 10.921 1.075 0.000 No 443.0 6.1 No Yes 7/30/2003 52,835 11.583 1.052 0.000 No 421.1 6.0 No Yes 11/20/2003 55,737 12.260 1.067 0.000 No 394.7 6.0 No Yes 2/19/2004 60,997 12.566 1.133 0.000 No 348.3 5.9 No Yes 11/15/2001 42,831 6.789 1.058 0.000 No 587.8 6.4 No Yes 10/24/2002 45,842 8.430 1.059 0.000 No 555.1 6.3 No Yes 4/10/2003 50,087 9.483 1.063 0.400 No 522.2 6.3 No Yes 7/30/2003 52,835 10.254 1.032 0.000 No 522.0 6.3 No Yes 10/16/2003 54,832 10.705 1.088 0.000 No 479.8 6.2 No Yes 2/19/2004 60,997 11.084 1.061 0.000 No 452.2 6.1 No Yes 7/15/2004 64,743 11.695 1.086 0.000 No 416.4 6.0 No Yes 12/9/2004 68,501 12.492 0.947 0.000 No 439.7 6.1 No Yes 2/3/2005 69,939 12.662 1.052 0.000 No 418.0 6.0 No Yes 4/21/2005 71,916 13.031 1.067 0.000 No 391.7 6.0 No Yes 1/12/2006 78,683 14.156 0.960 0.000 No 419.0 6.0 No Yes 3/24/2006 79,470 14.287 1.152 0.000 No 363.7 5.9 No Yes 5/4/2006 80,518 14.502 1.088 0.000 No 334.3 5.8 No Yes 7/13/2006 82,276 14.812 0.939 0.000 No 356.0 5.9 No Yes 10/26/2006 84,957 15.270 1.087 0.000 No 327.5 5.8 No Yes

Level: C LPRM ID No.: 219 Beginning of Life Calibration Current :

1,319.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/1221996 13,460 2.744 1.042 0.000 Yes 1,247.0 7.1 No Yes 8/25/1998 14,963 2.811 1.087 0.000 No 1,135.0 7.0 No Yes 9/29/1998 15,824 2.961 1.006 0.000 No 1,128.2 7.0 No Yes 2/4/1999 18,757 3.488 1.059 0.000 No 1,065.4 7.0 No Yes 6/24/1999 22,047 4.090 1.099 0.000 No 969.4 6.9 No Yes 11/24/1999 24,556 4.579 1.128 0.000 No 859.4 6.8 No Yes 12/27/1999 25,359 4.703 1.075 0.000 No 799.4 6.7 No Yes 3/8/2000 27,127 4.976 1.048 0.000 No 762.8 6.6 No Yes 7/20/2000 30,502 5.477 1.115 0.000 No 717.0 6.6 No Yes 12/7/2000 34,042 6.067 1.055 0.000 No 679.6 6.5 No Yes 3/22/2001 36,674 6.551 1.053 0.000 No 645.4 6.5 No Yes 8/17/2001 40,505 7.341 1.063 0.000 No 607.2 6.4 No Yes 2/14/2002 42,230 8.135 1.086 0.000 No 559.1 6.3 No Yes 7/30/2003 52,835 10.072 1.052 0.000 No 531.4 6.3 No Yes 12/30/2003 56,664 10.876 1.053 0.000 No 504.7 6.2 No Yes 2/19/2004 60,997 10.991 1.112 0.000 No 453.9 6.1 No Yes 6/17/2004 64,043 11.496 1.052 0.000 No 431.4 6.1 No Yes 1/6/2005 69,222 12.422 1.057 0.000 No 408.2 6.0 No Yes 8/4/2005 74,594 13.333 1.060 0.000 No 385.1 6.0 No Yes 1/12/2006 78,683 14.148 1.053 0.000 No 365.7 5.9 No Yes 3/24/2006 79,470 14.371 1.054 0.000 No 346.9 5.8 No Yes 8/17/2006 83,172 15.023 1.060 0.000 No 327.3 5.8 No Yes 10/26/2006 84,957 15.334 0.991 0.000 No 330.3 5.8 No Yes Level: D LPRM ID No.: 305 Beginning of Life Calibration Current :

1,261.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 8/25/1998 14,963 2.208 0.999 0.000 No 1,164.0 7.1 No Yes 9/29/1998 15,824 2.301 0.997 0.000 No 1,167.5 7.1 No Yes 11/24/1999 24,556 3.487 1.120 0.000 No 1,042.4 6.9 No Yes 8/12/2004 65,463 13.419 1.075 0.000 No 324.0 5.8 No Yes 2/3/2005 69,939 14.253 1.052 0.000 No 308.0 5.7 No Yes 10/20/2005 76,558 15.442 1.063 0.000 No 290.0 5.7 No Yes 3/24/2006 79,470 16.030 1.133 0.000 No 256.0 5.5 No Yes 10/26/2006 84,957 17.150 1.046 0.000 No 244.7 5.5 No Yes

String No. : 5 Serial No.: L-2692 Cycle Installed:

6 Coordinates:

Level:

49 A

Type:

LPRM ID No.:

NA300 48 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current :

86,992 1,059.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 1.915 1.057 0.000 Yes 954.0 6.9 No Yes 8/25/1998 22,612 2.010 0.983 0.000 No 970.5 6.9 No Yes 9/29/1998 23,473 2.143 1.013 0.000 No 958.0 6.9 No Yes 3/11/1999 27,265 2.622 1.054 0.000 No 912.0 6.8 No Yes 8/4/1999 30,557 3.089 1.048 0.000 No 870.2 6.8 No Yes 11/24/1999 32,205 3.283 1.098 0.000 No 792.6 6.7 No Yes 7/20/2000 38,151 4.047 1.065 0.000 No 744.2 6.6 No Yes 11/4/2000 40,841 4.475 1.059 0.000 No 702.7 6.6 No Yes 3/22/2001 44,323 5.054 1.055 0.000 No 666.1 6.5 No Yes 4/26/2001 45,228 5.235 1.073 0.000 No 620.8 6.4 No Yes 2/14/2002 49,879 6.432 1.074 0.000 No 545.8 6.3 No Yes 11/15/2001 50,480 6.208 1.059 0.000 No 586.2 6.4 No Yes 8/15/2002 51,721 7.269 1.092 0.000 No 499.8 6.2 No Yes 4/10/2003 57,736 8.449 1.072 0.000 No 466.2 6.1 No Yes 7/30/2003 60,484 9.034 1.040 0.000 No 466.0 6.1 No Yes 10/16/2003 62,481 9.328 1.060 0.000 No 439.6 6.1 No Yes 11/30/1999 24,692 3.498 1.058 0.000 No 985.3 6.9 No Yes 8/24/2000 31,408 4.083 1.051 0.000 No 937.5 6.8 No Yes 3/22/2001 36,674 4.663 1.057 0.000 No 886.9 6.8 No Yes 2/14/2002 42,230 5.715 1.055 0.000 No 796.8 6.7 No Yes 12/20/2001 43,726 5.625 1.055 0.000 No 840.7 6.7 No Yes 2/26/2003 49,017 6.216 0.923 0.000 No 863.3 6.8 No Yes 7/30/2003 52,835 6.483 1.047 0.000 No 863.0 6.8 No Yes 9/11/2003 53,930 6.585 1.051 0.000 No 821.1 6.7 No Yes 6/17/2004 64,043 7.268 1.090 0.000 No 753.3 6.6 No Yes 12/9/2004 68,501 7.794 1.081 0.000 No 696.9 6.5 No Yes 8/4/2005 74,594 8.754 1.039 0.000 No 670.7 6.5 No Yes 10/20/2005 76,558 9.123 1.091 0.000 No 639.0 6.5 No Yes 3/24/2006 79,470 9.759 1.054 0.000 No 606.3 6.4 No Yes 7/13/2006 82,276 10.134 1.068 0.000 No 567.7 6.3 No Yes 10/26/2006 84,957 10.538 0.942 0.000 No 602.6 6.4 No Yes

Level: B LPRM ID No.: 134 Beginning of Life Calibration Current :

1,062.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 2.804 1.054 0.000 Yes 856.0 6.8 No Yes 8/25/1998 22,612 2.904 0.977 0.000 No 876.2 6.8 No Yes 9/29/1998 23,473 3.082 1.014 0.000 No 864.1 6.8 No Yes 2/4/1999 26,406 3.640 1.077 0.000 No 802.3 6.7 No Yes 4/15/1999 28,093 3.951 1.062 0.000 No 755.4 6.6 No Yes 8/4/1999 30,557 4.355 1.056 0.000 No 715.4 6.6 No Yes 11/30/1999 32,341 4.635 1.088 0.000 No 657.5 6.5 No Yes 3/8/2000 34,776 5.073 1.057 0.000 No 622.1 6.4 No Yes 7/20/2000 38,151 5.689 1.053 0.000 No 590.8 6.4 No Yes 11/4/2000 40,841 6.204 1.053 0.000 No 561.0 6.3 No Yes 4/26/2001 45,228 7.031 1.068 0.000 No 525.3 6.3 No Yes 7/7/2001 47,088 7.387 1.051 0.000 No 499.8 6.2 No Yes 12/20/2001 51,375 8.178 1.056 0.000 No 473.3 6.2 No Yes 8/15/2002 51,721 9.217 1.086 0.000 No 435.8 6.1 No Yes 2/26/2003 56,666 10.241 1.053 0.000 No 413.9 6.0 No Yes 7/30/2003 60,484 11.022 1.056 0.000 No 391.9 6.0 No Yes 2/19/2004 68,646 11.775 1.148 0.000 No 341.4 5.8 No Yes 6/17/2004 71,692 12.339 1.073 0.000 No 318.2 5.8 No Yes 6/30/2005 81,352 13.701 1.051 0.000 No 302.7 5.7 No Yes 3/24/2006 87,119 14.478 0.948 0.000 No 319.3 5.8 No Yes 7/13/2006 89,925 15.014 1.051 0.000 No 303.9 5.7 No Yes 10/26/2006 92,606 15.479 1.012 0.000 No 300.2 5.7 No Yes Level : C LPRM ID No.: 220 Beginning of Life Calibration Current:

1,200.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good 3/25/2004 69,535 9.717 1.078 0.000 No 407.8 6.0 No Yes 9/23/2004 74,182 10.390 1.058 0.000 No 385.5 6.0 No Yes 12/9/2004 76,150 10.651 0.915 0.000 No 421.3 6.0 No Yes 8/4/2005 82,243 11.335 1.096 0.000 No 384.4 6.0 No Yes 9/15/2005 83,306 11.452 0.893 0.000 No 430.4 6.1 No Yes 12/1/2005 85,259 11.616 1.086 0.000 No 396.3 6.0 No Yes 1/12/2006 86,332 11.707 0.948 0.000 No 452.0 6.1 No Yes 3/24/2006 87,119 11.803 1.088 0.000 No 415.4 6.0 No Yes 5/4/2006 88,167 12.002 1.099 0.000 No 378.0 5.9 No Yes 10/26/2006 92,606 12.690 0.987 0.000 No 383.0 5.9 No Yes

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 3.278 1.054 0.000 Yes 886.0 6.8 No Yes 8/25/1998 22,612 3.340 0.975 0.000 No 908.7 6.8 No Yes 9/29/1998 23,473 3.479 1.013 0.000 No 897.1 6.8 No Yes 2/4/1999 26,406 3.968 1.059 0.000 No 847.1 6.7 No Yes 6/24/1999 29,696 4.521 1.098 0.000 No 771.5 6.6 No Yes 11/24/1999 32,205 4.982 1.075 0.000 No 717.7 6.6 No Yes 11/30/1999 32,341 5.004 1.052 0.000 No 682.2 6.5 No Yes 3/8/2000 34,776 5.377 1.053 0.000 No 647.8 6.5 No Yes 7/20/2000 38,151 5.851 1.069 0.000 No 606.0 6.4 No Yes 2/22/2001 43,598 6.698 1.070 0.000 No 566.4 6.3 No Yes 7/7/2001 47,088 7.268 1.052 0.000 No 538.4 6.3 No Yes 8/15/2002 51,721 8.728 1.062 0.000 No 507.0 6.2 No Yes 7/30/2003 60,484 9.975 1.066 0.000 No 475.6 6.2 No Yes 2/19/2004 68,646 10.782 1.159 0.000 No 410.3 6.0 No Yes 12/9/2004 76,150 11.965 1.061 0.000 No 386.7 6.0 No Yes 8/4/2005 82,243 12.834 1.083 0.000 No 357.1 5.9 No Yes 3/24/2006 87,119 13.695 0.927 0.000 No 385.2 6.0 No Yes 8/17/2006 90,821 14.274 1.068 0.000 No 360.7 5.9 No Yes 10/26/2006 92,606 14.529 0.993 0.000 No 363.2 5.9 No Yes Level: D LPRM ID No. : 306 Beginning of Life Calibration Current:

1,123.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 2.854 1.041 0.000 Yes 962.0 6.9 No Yes 8/25/1998 22,612 2.859 0.978 0.000 No 983.6 6.9 No Yes 9/29/1998 23,473 2.940 1.012 0.000 No 972.0 6.9 No Yes 6/24/1999 29,696 3.638 1.062 0.000 No 915.2 6.8 No Yes 11/24/1999 32,205 4.000 1.085 0.000 No 843.5 6.7 No Yes 11/30/1999 32,341 4.011 1.067 0.000 No 790.6 6.7 No Yes 4/12/2000 35,637 4.286 1.052 0.000 No 751.5 6.6 No Yes 1/18/2001 42,777 4.964 1.061 0.000 No 708.3 6.6 No Yes 9/13/2001 48,853 5.659 1.070 0.000 No 661.9 6.5 No Yes 2/14/2002 49,879 6.080 1.060 0.000 No 624.5 6.4 No Yes 7/30/2003 60,484 6.852 0.986 0.000 No 624.0 6.4 No Yes 2/19/2004 68,646 7.323 1.077 0.000 No 579.4 6.4 No Yes 12/9/2004 76,150 8.105 1.068 0.000 No 542.5 6.3 No Yes 9/15/2005 83,306 9.093 1.061 0.000 No 511.3 6.2 No Yes

5/4/2006 88,167 9.887 0.928 0.000 No 551.0 6.3 No Yes 10/26/2006 String No. :

Coordinates:

Level :

92,606 6

49 A

10.442 Serial No. :

Type :

LPRM ID No. :

1.027 03s61368 NA300 497 0.000 Cumulative Core Beginning No 536.5 Cycle Installed :

Average Exposure at BOC:

of Life Calibration Current:

6.3 No 18,500 1,250.0 Yes 11 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.029 1.058 0.000 No 1,181.5 7.1 No Yes 3/25/2004 1,043 0.287 1.085 0.000 No 1,088.9 7.0 No Yes 8/12/2004 4,620 1.420 0.926 0.000 No 1,175.9 7.1 No Yes 9/23/2004 5,690 1.736 1.058 0.000 No 1,111.5 7.0 No Yes 12/9/2004 7,658 2.328 0.906 0.000 No 1,226.8 7.1 No Yes 1/6/2005 8,379 2.499 1.054 0.000 No 1,163.9 7.1 No Yes 3/17/2005 10,169 2.959 0.945 0.000 No 1,231.7 7.1 No Yes 4/21/2005 11,073 3.207 1.082 0.000 No 1,138.3 7.0 No Yes 3/24/2006 18,627 5.227 1.180 0.000 No 964.7 6.9 No Yes 10/26/2006 24,114 6.861 1.010 0.000 No 955.1 6.9 No Yes Level: B LPRM ID No.: 507 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf s Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.041 1.086 0.000 No 1,151.0 7.0 No Yes 9/23/2004 5,690 1.594 0.939 0.000 No 1,225.8 7.1 No Yes 4/2112005 11,073 2.849 0.937 0.000 No 1,308.2 7.2 No Yes 12/1/2005 16,767 4.254 1.071 0.000 No 1,221.5 7.1 No Yes 3/24/2006 18,627 4.832 1.177 0.000 No 1,037.8 6.9 No Yes 10/26/2006 24,114 6.340 1.022 0.000 No 1,015.4 6.9 No Yes Level: C LPRM ID No. : 517 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12130/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 8/12/2004 4,620 1.029 0.941 0.000 No 1,328.4 7.2 No Yes 12/9/2004 7,658 1.675 0.941 0.000 No 1,411.7 7.3 No Yes 6/30/2005 12,860 2.721 0.948 0.000 No 1,489.1 7.3 No Yes 1/12/2006 17,840 4.036 1.059 0.000 No 1,406.1 7.2 No Yes

String No. : 7 Serial No. : 00s19542 Cycle Installed:

10 Coordinates:

Level :

49 A

Type :

LPRM ID No. :

NA300 401 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

37,300 700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.053 1.100 0.000 No 1,136.0 7.0 No Yes 3/29/2002 1,270 0.346 1.054 0.000 No 1,077.8 7.0 No Yes 2/26/2003 6,974 2.727 1.062 0.000 No 1,014.9 6.9 No Yes 5/15/2003 8,890 3.413 1.106 0.000 No 917.6 6.8 No Yes 7/30/2003 10,792 3.953 1.066 0.000 No 860.8 6.8 No Yes 10/16/2003 12,789 4.513 1.100 0.000 No 782.5 6.7 No Yes 2/19/2004 18,954 5.036 1.119 0.000 No 699.3 6.6 No Yes 5/6/2004 20,923 5.681 1.063 0.000 No 657.9 6.5 No Yes 6/17/2004 22,000 6.036 1.069 0.000 No 615.4 6.4 No Yes 12/9/2004 26,458 7.292 1.123 0.000 No 548.0 6.3 No Yes 2/3/2005 27,896 7.782 1.057 0.000 No 518.5 6.3 No Yes 4/21/2005 29,873 8.555 1.058 0.000 No 490.0 6.2 No Yes 8/4/2005 32,551 9.461 1.061 0.000 No 461.9 6.1 No Yes 3/24/2006 37,427 10.690 1.130 0.000 No 408.7 6.0 No Yes 3/24/2006 10/26/2006 18,627 24,114 4.350 5.551 1.167 1.012 0.000 0.000 No No 1,204.9 1,190.6 7.1 7.1 No No Yes Yes Level: D LPRM ID No.: 527 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gays Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.018 0.942 0.000 No 1,327.0 7.2 No Yes 9/23/2004 5,690 0.659 0.917 0.000 No 1,447.1 7.3 No Yes 1/6/2005 8,379 1.021 0.941 0.000 No 1,537.8 7.3 No Yes 4/21/2005 11,073 1.452 0.946 0.000 No 1,625.6 7.4 No Yes 5/31/2005 12,092 1.624 1.065 0.000 No 1,526.4 7.3 No Yes 9/15/2005 14,814 2.134 0.896 0.000 No 1,704.0 7.4 No Yes 12/1/2005 16,767 2.582 1.083 0.000 No 1,573.4 7.4 No Yes 5/4/2006 19,675 3.235 1.071 0.000 No 1,469.1 7.3 No Yes 8/17/2006 22,329 3.669 0.948 0.000 No 1,549.7 7.3 No Yes 9/21/2006 23,220 3.813 0.932 0.000 No 1,662.8 7.4 No Yes 10/26/2006 24,114 3.942 1.061 0.000 No 1,567.2 7.4 No Yes

7/13/2006 9/21/2006 10/26/2006 Level:

40,233 42,020 42,914 B

11.461 11.946 12.247 LPRM ID No.:

1.055 1.082 1.000 409 0.000 0.000 0.000 Beginning No No No of Life Calibration 387.4 358.1 358.1 Current :

6.0 5.9 5.9 No No No 700.0 Yes Yes Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.051 1.054 0.000 No 1,186.0 7.1 No Yes 8/15/2002 2,029 1.351 0.943 0.000 No 1,257.7 7.1 No Yes 6/19/2003 9,728 3.506 1.067 0.000 No 1,178.7 7.1 No Yes 7/30/2003 10,792 3.781 1.044 0.000 No 1,179.0 7.1 No Yes 9/11/2003 11,887 4.069 1.072 0.000 No 1,099.8 7.0 No Yes 10/16/2003 12,789 4.336 1.061 0.000 No 1,036.6 6.9 No Yes 12/30/2003 14,621 4.842 1.058 0.000 No 979.8 6.9 No Yes 2/19/2004 18,954 4.979 1.193 0.000 No 821.3 6.7 No Yes 6/17/2004 22,000 5.890 1.113 0.000 No 737.9 6.6 No Yes 9/23/2004 24,490 6.544 1.056 0.000 No 698.7 6.5 No Yes 12/9/2004 26,458 7.058 1.068 0.000 No 654.3 6.5 No Yes 3/17/2005 28,969 7.747 1.072 0.000 No 610.3 6.4 No Yes 5/31/2005 30,892 8.271 1.054 0.000 No 579.0 6.4 No Yes 8/4/2005 32,551 8.701 1.056 0.000 No 548.3 6.3 No Yes 10/20/2005 34,515 9.250 1.053 0.000 No 521.0 6.3 No Yes 1/12/2006 36,640 9.854 1.078 0.000 No 483.3 6.2 No Yes 3/24/2006 37,427 10.169 1.089 0.000 No 443.8 6.1 No Yes 7/13/2006 40,233 10.952 1.053 0.000 No 421.5 6.0 No Yes 10/26/2006 42,914 11.735 1.051 0.000 No 401.0 6.0 No Yes Level : C LPRM ID No. : 417 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.037 1.046 0.000 No 1,250.0 7.1 No Yes 3/29/2002 1,270 0.269 1.091 0.000 No 1,145.7 7.0 No Yes 8/15/2002 2,029 0.963 0.927 0.000 No 1,236.0 7.1 No Yes 5/15/2003 8,890 2.566 1.069 0.000 No 1,156.2 7.1 No Yes 7/30/2003 10,792 3.078 1.089 0.000 No 1,061.7 7.0 No Yes 9/11/2003 11,887 3.406 1.065 0.000 No 996.9 6.9 No Yes 10/16/2003 12,789 3.670 1.063 0.000 No 937.8 6.8 No Yes 12/30/2003 14,621 4.241 1.093 0.000 No 858.0 6.8 No Yes 2/19/2004 18,954 4.393 1.066 0.000 No 804.9 6.7 No Yes

10/26/2006 42,914 10.381 1.049 0.000 No 417.7 6.0 No Yes Level : D LPRM ID No. : 425 Beginning of Life Calibration Current :

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.013 0.988 0.000 No 1,250.0 7.1 No Yes 6/6/2002 223 0.211 0.989 0.000 No 1,163.0 7.1 No Yes 8/15/2002 2,029 0.349 0.948 0.000 No 1,226.8 7.1 No Yes 2/26/2003 6,974 0.859 0.901 0.000 No 1,346.0 7.2 No Yes 7/30/2003 10,792 1.302 0.982 0.000 No 1,346.0 7.2 No Yes 3/25/2004 19,843 2.188 1.095 0.000 No 1,229.2 7.1 No Yes 10/28/2004 25,391 2.895 1.066 0.000 No 1,153.1 7.1 No Yes 4/21/2005 29,873 3.637 1.058 0.000 No 1,089.9 7.0 No Yes 6/30/2005 31,660 3.947 1.069 0.000 No 1,019.6 6.9 No Yes 9/15/2005 33,614 4.371 1.100 0.000 No 926.9 6.8 No Yes 12/1/2005 35,567 4.852 1.094 0.000 No 847.2 6.7 No Yes 1/12/2006 36,640 5.144 1.027 0.000 No 803.0 6.7 No Yes 6/8/2006 39,339 5.735 1.100 0.000 No 730.0 6.6 No Yes 10/26/2006 42,914 6.498 1.068 0.000 No 683.5 6.5 No Yes String No. : 8 Serial No. : OOs19547 Cycle Installed :

10 Coordinates : 49 Type : NA300 Cumulative Core Average Exposure at BOC :

37,300 Level : A LPRM ID No. : 402 Beginning of Life Calibration Current :

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.060 1.148 0.000 No 1,066.0 7.0 No Yes 3/29/2002 1,270 0.428 1.063 0.000 No 1,002.8 6.9 No Yes 12/5/2002 4,866 2.098 1.051 0.000 No 901.0 6.8 No Yes 1/16/2003 5,920 2.338 0.945 0.000 No 953.4 6.9 No Yes 5/6/2004 20,923 4.839 1.055 0.000 No 762.9 6.6 No Yes 8/12/2004 23,420 5.397 1.064 0.000 No 717.0 6.6 No Yes 12/9/2004 26,458 6.054 1.081 0MO No 663.3 6.5 No Yes 5/31/2005 30,892 7.121 1.089 0.000 No 609.1 6.4 No Yes 8/4/2005 32,551 7.516 1.067 0.000 No 570.9 6.3 No Yes 12/1/2005 35,567 8.422 1.085 0.000 No 526.1 6.3 No Yes 1/12/2006 36,640 8.766 1.040 0.000 No 501.0 6.2 No Yes 3/24/2006 37,427 9.113 1.087 0.000 No 460.9 6.1 No Yes 6/8/2006 39,339 9.523 1.052 0.000 No 438.1 6.1 No Yes

Level: B LPRM ID No. : 410 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.057 1.117 0.000 No 1,119.0 7.0 No Yes 12/5/2002 4,866 2.154 1.072 0.000 No 1,043.8 7.0 No Yes 2/26/2003 6,974 2.780 1.074 0.000 No 971.9 6.9 No Yes 5/15/2003 8,890 3.387 1.106 0.000 No 878.8 6.8 No Yes 7/30/2003 10,792 3.908 1.078 0.000 No 815.2 6.7 No Yes 10/16/2003 12,789 4.477 1.060 0.000 No 769.0 6.6 No Yes 12/30/2003 14,621 4.987 1.076 0.000 No 714.7 6.6 No Yes 2/19/2004 18,954 5.119 1.122 0.000 No 637.0 6.5 No Yes 8/12/2004 23,420 6.314 1.086 0.000 No 586.6 6.4 No Yes 2/3/2005 27,896 7.537 1.096 0.000 No 535.2 6.3 No Yes 6/30/2005 31,660 8.595 1.088 0.000 No 491.9 6.2 No Yes 12/1/2005 35,567 9.734 1.063 0.000 No 462.7 6.1 No Yes 1/12/2006 36,640 10.035 1.064 0.000 No 434.9 6.1 No Yes 3/24/2006 37,427 10.353 1.083 0.000 No 401.6 6.0 No Yes 6/8/2006 39,339 10.943 1.053 0.000 No 381.4 5.9 No Yes 10/26/2006 42,914 11.918 1.054 0.000 No 361.8 5.9 No Yes Level: C LPRM ID No.: 418 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.037 1.086 0.000 No 1,151.0 7.0 No Yes 1/16/2003 5,920 1.949 1.050 0.000 No 1,096.2 7.0 No Yes 2/26/2003 6,974 2.738 1.097 0.000 No 869.1 6.8 No Yes 5/15/2003 8,890 3.547 1.147 0.000 No 757.7 6.6 No Yes 6/19/2003 9,728 3.818 1.059 0.000 No 715.5 6.6 No Yes 7/30/2003 10,792 4.112 1.021 0.000 No 716.0 6.6 No Yes 10/16/2003 12,789 4.692 1.066 0.000 No 599.0 6.4 No Yes 3/25/2004 19,843 5.472 1.052 0.000 No 569.4 6.3 No Yes 6/17/2004 22,000 6.086 1.051 0.000 No 541.8 6.3 No Yes 9/23/2004 24,490 6.791 1.102 0.000 No 491.6 6.2 No Yes 3/17/2005 28,969 8.345 1.109 0.000 No 443.3 6.1 No Yes 9/15/2005 33,614 10.063 1.052 0.000 No 421.4 6.0 No Yes 1/12/2006 36,640 10.761 1.074 0.000 No 392.4 6.0 No Yes 3/24/2006 37,427 10.986 1.157 0.000 No 339.1 5.8 No Yes 10/26/2006 42,914 12.487 1.040 0.000 No 326.1 5.8 No Yes

String No.: 9 Serial No. : 03s61362 Cycle Installed:

11 Coordinates: 49 Type : NA300 Cumulative Core Average Exposure at BOC:

18,500 Level: A LPRM ID No. : 498 Beginning of Life Calibration Current:

1,250.0 5/15/2003 8,890 2.586 1.071 0.000 No 1,023.5 6.9 No Yes 7/30/2003 10,792 3.132 1.108 0.000 No 923.8 6.8 No Yes 9/11/2003 11,887 3.469 1.063 0.000 No 869.0 6.8 No Yes 11/20/2003 13,694 4.014 1.073 0.000 No 809.9 6.7 No Yes 2/19/2004 18,954 4.451 1.133 0.000 No 714.8 6.6 No Yes 8/12/2004 23,420 5.365 1.055 0.000 No 677.6 6.5 No Yes 1/6/2005 27,179 6.226 1.071 0.000 No 632.6 6.4 No Yes 5/31/2005 30,892 7.094 1.056 0.000 No 599.1 6.4 No Yes 9/15/2005 33,614 7.830 1.085 0.000 No 552.2 6.3 No Yes 12/1/2005 35,567 8.444 1.053 0.000 No 524.4 6.3 No Yes 1/12/2006 36,640 8.782 0.000 0.000 No 480.0 6.2 No Yes 5/4/2006 38,475 9.379 1.084 0.000 No 442.8 6.1 No Yes 6/8/2006 39,339 9.582 1.055 0.000 No 419.7 6.0 No Yes 10/26/2006 42,914 10.416 1.034 0.000 No 405.9 6.0 No Yes Level: D LPRM ID No.: 426 Beginning of Life Calibration Current :

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.013 1.023 0.000 No 1,250.0 7.1 No Yes 1/16/2003 5,920 0.768 0.949 0.000 No 1,317.2 7.2 No Yes 5/15/2003 8,890 1.062 0.939 0.000 No 1,402.7 7.2 No Yes 7/30/2003 10,792 1.313 1.026 0.000 No 1,403.0 7.2 No Yes 2/19/2004 18,954 2.115 1.058 0.000 No 1,326.1 7.2 No Yes 8/12/2004 23,420 2.626 1.094 0.000 No 1,212.1 7.1 No Yes 9/23/2004 24,490 2.789 0.928 0.000 No 1,306.2 7.2 No Yes 2/3/2005 27,896 3.355 1.138 0.000 No 1,147.8 7.0 No Yes 6/30/2005 31,660 3.992 1.135 0.000 No 1,011.3 6.9 No Yes 9/15/2005 33,614 4.408 1.079 0.000 No 937.2 6.8 No Yes 12/1/2005 35,567 4.886 1.065 0.000 No 880.0 6.8 No Yes 1/12/2006 36,640 5.183 1.049 0.000 No 807.0 6.7 No Yes 3/24/2006 37,427 5.491 0.978 0.000 No 807.0 6.7 No Yes 6/8/2006 39,339 5.794 1.071 0.000 No 753.5 6.6 No Yes 7/13/2006 40,233 5.992 1.078 0.000 No 699.0 6.5 No Yes 10/26/2006 42,914 6.605 1.028 0.000 No 679.9 6.5 No Yes

String No.: 10 Serial No.: 05x105126 Cycle Installed:

12 Coordinates: 49 Type: NA300 Cumulative Core Average Exposure at BOC:

0 Level: A LPRM ID No.: 577 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 18,627 5.639 1.656 0.000 No 754.8 6.6 No Yes 9/21/2006 23,220 6.986 1.088 0.000 No 693.8 6.5 No Yes 10/26/2006 24,114 7.272 0.984 0.000 No 705.1 6.6 No Yes Level: B LPRM ID No. : 508 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.047 1.152 0.000 No 1,085.1 7.0 No Yes 6/17/2004 3,200 0.960 0.944 0.000 No 1,149.4 7.0 No Yes 1/6/2005 8,379 2.308 0.928 0.000 No 1,238.6 7.1 No Yes 3/24/2006 18,627 5.054 1.127 0.000 No 1,099.0 7.0 No Yes 8/17/2006 22,329 6.107 1.052 0.000 No 1,044.7 7.0 No Yes 10/26/2006 24,114 6.643 1.002 0.000 No 1,042.6 6.9 No Yes Level : C LPRM ID No.: 518 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.042 1.063 0.000 No 1,175.9 7.1 No Yes 6/8/2006 20,539 4.925 1.060 0.000 No 1,179.2 7.1 No Yes 10/26/2006 24,114 5.792 1.015 0.000 No 1,161.8 7.1 No Yes Level: D LPRM ID No.: 528 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.019 0.932 0.000 No 1,341.2 7.2 No Yes 12/9/2004 7,658 0.969 0.933 0.000 No 1,437.5 7.3 No Yes 6/8/2006 20,539 3.556 1.065 0.000 No 1,349.8 7.2 No Yes 7/13/2006 21,433 3.719 1.060 0.000 No 1,273.4 7.1 No Yes 8/17/2006 22,329 3.891 0.945 0.000 No 1,347.5 7.2 No Yes 10/26/2006 24,114 4.209 0.995 0.000 No 1,354.3 7.2 No Yes

Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp ?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.036 1.143 0.000 No 1,093.6 7.0 No Yes 7/13/2006 2,933 0.792 1.054 0.000 No 1,037.6 6.9 No Yes 9/21/2006 4,720 1.194 0.934 0.000 No 1,110.9 7.0 No Yes 10/26/2006 5,614 1.339 1.027 0.000 No 1,081.7 7.0 No Yes Level: B LPRM ID No.: 585 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.0()0 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.032 1.057 0.000 No 1,182.6 7.1 No Yes 6/8/2006 2,039 0.534 1.054 0.000 No 1,122.0 7.0 No Yes 10/26/2006 5,614 1.379 0.969 0.000 No 1,157.9 7.1 No Yes Level: C LPRM ID No. : 593 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp-?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.023 1.035 0.000 No 1,250.0 7.1 No Yes 6/8/2006 2,039 0.406 1.091 0.000 No 1,145.7 7.0 No Yes 10/26/2006 5,614 1.101 0.962 0.000 No 1,191.0 7.1 No Yes Level: D LPRM ID No. : 601 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 6/8/2006 2,039 0.265 1.057 0.000 No 1,182.6 7.1 No Yes 10/26/2006 5,614 0.786 0.959 0.000 No 1,233.2 7.1 No Yes String No.: 11 Serial No. : 0109549 Cycle installed:

11 Coordinates: 41 Type : NA300 Cumulative Core Average Exposure at BOC:

18,500 Level: A LPRM ID No. : 499 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.026 1.137 0.000 No 1,099.4 7.0 No Yes 3/25/2004 1,043 0.221 1.078 0.000 No 1,019.8 6.9 No Yes 10/28/2004 6,591 1.608 0.936 0.000 No 1,089.6 7.0 No Yes

Level: B LPRM ID No.: 509 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.038 1.136 0.000 No 1,100.4 7.0 No Yes 3/17/2005 10,169 2.345 0.995 0.000 No 1,105.9 7.0 No Yes 6/30/2005 12,860 2.920 1.108 0.000 No 993.1 6.9 No Yes 10/20/2005 15,715 3.571 1.071 0.000 No 927.0 6.8 No Yes 1/1212006 17,840 4.106 1.052 0.000 No 838.0 6.7 No Yes 3/24/2006 18,627 4.385 1.013 0.000 No 838.0 6.7 No Yes 6/8/2006 20,539 4.884 1.089 0.000 No 769.5 6.6 No Yes 8/17/2006 22,329 5.333 1.056 0.000 No 728.7 6.6 No Yes 10/26/2006 24,114 5.803 1.043 0.000 No 698.7 6.5 No Yes Level: C LPRM ID No. : 519 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.036 1.053 0.000 No 1,187.1 7.1 No Yes 12/9/2004 7,658 1.503 0.930 0.000 No 1,276.4 7.2 No Yes 2/3/2005 9,096 1.816 1.057 0.000 No 1,207.6 7.1 No Yes 8/4/2005 13,751 2.714 1.090 0.000 No 1,107.9 7.0 No Yes 10/20/2005 15,715 3.170 1.071 0.000 No 1,034.0 6.9 No Yes 1/12/2006 17,840 3.752 1.053 0.000 No 908.0 6.8 No Yes 3/24/2006 18,627 4.051 1.070 0.000 No 848.6 6.7 No Yes 7/13/2006 21,433 4.617 1.070 0.000 No 793.1 6.7 No Yes 10/26/2006 24,114 5.179 1.045 0.000 No 758.9 6.6 No Yes Level: D LPRM ID No.: 529 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good 1/6/2005 8,379 2.053 1.061 0.000 No 1,026.9 6.9 No Yes 3/17/2005 10,169 2.470 1.069 0.000 No 960.6 6.9 No Yes 4/21/2005 11,073 2.697 0.945 0.000 No 1,016.6 6.9 No Yes 5/31/2005 12,092 2.978 1.146 0.000 No 887.0 6.8 No Yes 8/4/2005 13,751 3.521 1.071 0.000 No 828.2 6.7 No Yes 1/12/2006 17,840 4.519 1.001 0.000 No 749.0 6.6 No Yes 5/4/2006 19,675 5.073 1.079 0.000 No 694.2 6.5 No Yes 7/13/2006 21,433 5.560 1.065 0.000 No 651.8 6.5 No Yes 10/26/2006 24,114 6.322 1.065 0.000 No 612.0 6.4 No Yes

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/25/2004 1,043 0.102 0.901 0.000 No 1,387.3 7.2 No Yes 5/6/2004 2,123 0.210 1.058 0.000 No 1,311.3 7.2 No Yes 2/3/2005 9,096 1.110 0.908 0.000 No 1,444.2 7.3 No Yes 4/21/2005 11,073 1.431 1.053 0.000 No 1,371.5 7.2 No Yes 8/4/2005 13,751 1.853 0.925 0.000 No 1,482.7 7.3 No Yes 10/20/2005 15,715 2.249 1.066 0.000 No 1,391.0 7.2 No Yes 12/1/2005 16,767 2.469 1.051 0.000 No 1,323.5 7.2 No Yes 7/13/2006 21,433 3.342 1.076 0.000 No 1,230.0 7.1 No Yes 10/26/2006 24,114 3.774 1.091 0.000 No 1,127.4 7.0 No Yes String No.: 12 Serial No. : 03s61367 Cycle Installed:

11 Coordinates: 41 Type : NA300 Cumulative Core Average Exposure at BOC:

18,500 Level: A LPRM ID No. : 500 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf s Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.033 0.934 0.000 No 1,338.3 7.2 No Yes 3/25/2004 1,043 0.341 1.149 0.000 No 1,164.8 7.1 No Yes 3/17/2005 10,169 3.382 0.940 0.000 No 1,239.1 7.1 No Yes 5/31/2005 12,092 4.160 1.092 0.000 No 1,134.7 7.0 No Yes 3/24/2006 18,627 5.770 1.167 0.000 No 972.3 6.9 No Yes 10/26/2006 24,114 7.336 1.051 0.000 No 925.2 6.8 No Yes Level: B LPRM ID No.: 510 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf s Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/31/2005 12,092 3.434 0.938 0.000 No 1,310.0 7.2 No Yes 12/1/2005 16,767 4.689 1.081 0.000 No 1,211.8 7.1 No Yes 3/24/2006 18,627 5.297 1.187 0.000 No 1,020.9 6.9 No Yes 10/26/2006 24,114 6.893 1.017 0.000 No 1,003.9 6.9 No Yes Level: C LPRM ID No. : 520 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 6/17/2004 3,200 0.759 0.939 0.000 No 1,331.2 7.2 No Yes

12/9/2004 7,658 1.729 0.940 0.000 No 1,416.2 7.3 No Yes 1/12/2006 17,840 4.369 1.051 0.000 No 1,347.5 7.2 No Yes 3/24/2006 18,627 4.711 1.153 0.000 No 1,168.7 7.1 No Yes 7/13/2006 21,433 5.377 1.053 0.000 No 1,109.8 7.0 No Yes 10/26/2006 24,114 6.073 0.965 0.000 No 1,150.1 7.0 No Yes Level: D LPRM ID No.: 530 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 6/17/2004 3,200 0.367 0.936 0.000 No 1,335.5 7.2 No Yes 12/9/2004 7,658 1.044 1.051 0.000 No 1,270.7 7.1 No Yes 3/17/2005 10,169 1.467 0.937 0.000 No 1,356.1 7.2 No Yes 5/31/2005 12,092 1.803 0.923 0.000 No 1,469.2 7.3 No Yes 9/15/2005 14,814 2.365 1.068 0.000 No 1,375.7 7.2 No Yes 12/1/2005 16,767 2.832 0.923 0.000 No 1,490.4 7.3 No Yes 1/12/2006 17,840 3.123 1.084 0.000 No 1,375.0 7.2 No Yes 5/4/2006 19,675 3.576 1.052 0.000 No 1,307.0 7.2 No Yes 10/26/2006 24,114 4.472 1.003 0.000 No 1,303.1 7.2 No Yes String No. : 13 Serial No.: 04s82833 Cycle Installed:

12 Coordinates: 41 Type : NA300 Cumulative Core Average Exposure at BOC:

0 Level: A LPRM ID No.: 578 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.046 1.132 0.000 No 1,104.2 7.0 No Yes 6/8/2006 2,039 0.690 1.069 0.000 No 1,033.0 6.9 No Yes 10/26/2006 5,614 1.747 0.945 0.000 No 1,093.1 7.0 No Yes Level: B LPRM ID No.: 586 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 6/8/2006 2,039 0.653 1.051 0.000 No 1,189.3 7.1 No Yes 10/26/2006 5,614 1.743 0.952 0.000 No 1,249.3 7.1 No Yes Level: C LPRM ID No.: 594 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value

String No.: 14 Serial No. : K-7092 Cycle Installed:

7 Coordinates:

Level:

41 A

Type:

LPRM ID No.:

NA300 57 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

79,343 1,265.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 3.510 1.043 0.000 Yes 1,026.0 6.9 No Yes 8/25/1998 14,963 3.654 1.021 0.000 No 1,004.9 6.9 No Yes 9/29/1998 15,824 3.926 1.024 0.000 No 981.3 6.9 No Yes 2/4/1999 18,757 4.700 1.103 0.000 No 889.7 6.8 No Yes 3/11/1999 19,616 4.940 0.000 0.000 No 890.0 6.8 Yes Yes 6/14/2000 29,572 7.440 0.000 0.000 No 552.0 6.3 No Yes 11/4/2000 33,192 8.248 1.063 0.000 No 519.3 6.3 No Yes 1/18/2001 35,128 8.608 1.069 0.000 No 485.8 6.2 No Yes 8/17/2001 40,505 9.971 1.067 0.000 No 455.3 6.1 No Yes 2/14/2002 42,230 10.795 1.064 0.000 No 403.7 6.0 No Yes 11/15/2001 42,831 10.430 1.060 0.000 No 429.5 6.1 No Yes 3/29/2002 43,313 11.105 1.052 0.000 No 383.7 5.9 No Yes 9/19/2002 44,942 12.435 1.064 0.000 No 360.6 5.9 No Yes 12/5/2002 46,909 12.824 1.057 0.000 No 341.2 5.8 No Yes 7/30/2003 52,835 14.723 1.086 0.000 No 314.2 5.7 No Yes 12/30/2003 56,664 15.712 1.054 0.000 No 298.1 5.7 No Yes 5/6/2004 62,966 16.469 1.086 0.000 No 274.5 5.6 No Yes 3/17/2005 71,012 19.254 1.065 0.000 No 257.7 5.6 No Yes 4/21/2005 71,916 19.588 1.130 0.000 No 228.1 5.4 No Yes 5/31/2005 72,935 19.945 0.905 0.000 No 252.0 5.5 No Yes 8/4/2005 74,594 20.459 1.073 0.000 No 234.9 5.5 No Yes 1/12/2006 78,683 21.179 1.026 0.000 No 216.0 5.4 No Yes 2/16/2006 0

10/26/2006 5,614 0.000 1.000 1.417 0.978 0.000 0.000 No No 1,250.0 1,278.1 7.1 7.2 No No Yes Yes Level: D LPRM ID No. : 602 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.016 0.882 0.000 No 1,417.2 7.3 No Yes 6/8/2006 2,039 0.303 1.053 0.000 No 1,345.9 7.2 No Yes 10/26/2006 5,614 1.108 0.967 0.000 No 1,391.8 7.2 No Yes

3/24/2006 6/8/2006 10/26/2006 79,470 81,382 84,957 21.384 21.960 23.088 1.082 1.094 1.036 0.000 0.000 0.000 No 199.6 No 182.5 No 176.1 5.3 5.2 5.2 No No No Yes Yes Yes Level: B LPRM ID No.: 143 Beginning of Life Calibration Current :

1,289.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 4.292 1.102 0.000 Yes 831.0 6.7 No Yes 8/25/1998 14,963 4.376 0.995 0.000 No 835.2 6.7 No Yes 9/29/1998 15,824 4.648 1.047 0.000 No 797.7 6.7 No Yes 12/29/1998 17,872 5.225 1.119 0.000 No 712.9 6.6 No Yes 3/11/1999 19,616 5.697 1.071 0.000 No 666.0 6.5 No Yes 4/15/1999 20,444 5.924 1.067 0.000 No 624.2 6.4 No Yes 6/24/1999 22,047 6.373 1.070 0.000 No 583.3 6.4 No Yes 9/17/1999 23,855 6.930 1.087 0.000 No 536.7 6.3 No Yes 11/24/1999 24,556 7.153 1.161 0.000 No 462.2 6.1 No Yes 11/30/1999 24,692 7.187 1.059 0.000 No 436.5 6.1 No Yes 3/8/2000 27,127 7.871 1.061 0.000 No 411.4 6.0 No Yes 5/10/2000 28,679 8.280 1.059 0.000 No 388.5 6.0 No Yes 7/20/2000 30,502 8.730 1.056 0.000 No 367.9 5.9 No Yes 11/4/2000 33,192 9.379 1.058 0.000 No 347.7 5.9 No Yes 1/18/2001 35,128 9.811 1.069 0.000 No 325.3 5.8 No Yes 6/7/2001 38,668 10.672 1.073 0.000 No 303.1 5.7 No Yes 2/14/2002 42,230 12.075 1.071 0.000 No 257.5 5.6 No Yes 11/15/2001 42,831 11.646 1.099 0.000 No 275.8 5.6 No Yes 3/29/2002 43,313 12.381 1.055 0.000 No 244.1 5.5 No Yes 10/24/2002 45,842 13.881 1.070 0.000 No 228.1 5.4 No Yes 4/10/2003 50,087 15.043 1.065 0.000 No 214.2 5.4 No Yes 7/30/2003 52,835 15.873 1.054 0.000 No 203.2 5.3 No Yes 2/19/2004 60,997 17.064 1.191 0.000 No 170.6 5.1 No Yes 6/17/2004 64,043 18.010 1.060 0.000 No 161.0 5.1 No Yes 1/6/2005 69,222 19.495 1.083 0.000 No 148.7 5.0 No Yes 6/30/2005 73,703 20.710 1.052 0.000 No 141.3 5.0 No Yes 12/1/2005 77,610 21.745 1.060 0.000 No 133.3 4.9 No Yes 1/12/2006 78,683 22.004 1.013 0.000 No 131.6 4.9 No Yes Level: C LPRM ID No.: 229 Beginning of Life Calibration Current :

1,336.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value

9/12/1996 13,460 4.156 1.026 0.000 Yes 1,119.0 7.0 No Yes 8/25/1998 14,963 4.185 1.002 0.000 No 1,116.8 7.0 No Yes 9/29/1998 15,824 4.388 1.045 0.000 No 1,068.7 7.0 No Yes 2/4/1999 18,757 5.070 1.087 0.000 No 983.1 6.9 No Yes 4/15/1999 20,444 5.481 1.084 0.000 No 907.0 6.8 No Yes 6/24/1999 22,047 5.891 1.069 0.000 No 848.4 6.7 No Yes 9/17/1999 23,855 6.446 1.090 0.000 No 778.4 6.7 No Yes 11/24/1999 24,556 6.692 1.154 0.000 No 674.5 6.5 No Yes 12/27/1999 25,359 6.884 1.071 0.000 No 629.8 6.4 No Yes 4/12/2000 27,988 7.439 1.072 0.000 No 587.0 6.4 No Yes 6/14/2000 29,572 7.729 1.051 0.000 No 558.5 6.3 No Yes 9/28/2000 32,317 8.229 1.056 0.000 No 528.9 6.3 No Yes 12/7/2000 34,042 8.557 1.078 0.000 No 490.6 6.2 No Yes 4/26/2001 37,579 9.193 1.061 0.000 No 462.4 6.1 No Yes 10/18/2001 42,107 10.202 1.062 0.000 No 435.4 6.1 No Yes 3/29/2002 43,313 11.109 1.071 0.000 No 383.9 6.0 No Yes 12/20/2001 43,726 10.669 1.059 0.000 No 411.2 6.0 No Yes 10/24/2002 45,842 12.282 1.080 0.000 No 355.5 5.9 No Yes 5/15/2003 50,933 13.473 1.068 0.000 No 332.8 5.8 No Yes 7/30/2003 52,835 13.974 1.042 0.000 No 333.0 5.8 No Yes 9/11/2003 53,930 14.293 1.074 0.000 No 310.1 5.7 No Yes 12/30/2003 56,664 15.125 1.064 0.000 No 291.4 5.7 No Yes 2/19/2004 60,997 15.274 1.097 0.000 No 265.6 5.6 No Yes 6/17/2004 64,043 15.979 1.051 0.000 No 252.7 5.5 No Yes 3/17/2005 71,012 17.612 1.060 0.000 No 238.4 5.5 No Yes 9/15/2005 75,657 18.758 1.063 0.000 No 224.3 5.4 No Yes 1/12/2006 78,683 19.628 1.092 0.000 No 205.4 5.3 No Yes 3/24/2006 79,470 19.974 1.094 0.000 No 187.8 5.2 No Yes 9/21/2006 84,063 21.115 1.058 0.000 No 177.5 5.2 No Yes 10/26/2006 84,957 21.350 1.005 0.000 No 176.6 5.2 No Yes Level: D LPRM ID No. : 315 Beginning of Life Calibration Current:

1,343.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Lip.?

Value 9/12/1996 13,460 2.922 1.005 0.000 Yes 1,291.0 7.2 No Yes 8/25/1998 14,963 2.891 0.988 0.000 No 1,306.7 7.2 No Yes 9/29/1998 15,824 3.018 0.991 0.000 No 1,318.5 7.2 No Yes 4/15/1999 20,444 3.852 1.076 0.000 No 1,225.4 7.1 No Yes

9/17/1999 23,855 4.591 1.077 0.000 No 1,137.8 7.0 No Yes 11/24/1999 24,556 4.785 1.102 0.000 No 1,032.5 6.9 No Yes 12/27/1999 25,359 4.912 1.081 0.000 No 955.1 6.9 No Yes 6/14/2000 29,572 5.482 1.079 0.000 No 885.2 6.8 No Yes 9/28/2000 32,317 5.889 1.059 0.000 No 835.9 6.7 No Yes 12/7/2000 34,042 6.265 1.076 0.000 No 776.8 6.7 No Yes 3/22/2001 36,674 6.734 1.057 0.000 No 734.9 6.6 No Yes 8/17/2001 40,505 7.355 1.073 0.000 No 684.9 6.5 No Yes 10/18/2001 42,107 7.720 1.064 0.000 No 643.7 6.5 No Yes 3/29/2002 43,313 8.301 1.058 0.000 No 577.3 6.4 No Yes 12/20/2001 43,726 8.075 1.054 0MO No 610.8 6.4 No Yes 7/30/2003 52,835 9.614 1.041 0.000 No 577.0 6.4 No Yes 12/30/2003 56,664 10.354 1.077 0.000 No 535.7 6.3 No Yes 2/19/2004 60,997 10.462 1.071 0.000 No 500.2 6.2 No Yes 3/25/2004 61,886 10.561 1.089 0.000 No 459.3 6.1 No Yes 5/6/2004 62,966 10.692 0.912 0MO No 503.7 6.2 No Yes 6/17/2004 64,043 10.832 1.113 0.000 No 452.5 6.1 No Yes 7/15/2004 64,743 10.931 0.918 0.000 No 493.0 6.2 No Yes 8/12/2004 65,463 11.040 1.103 0.000 No 446.9 6.1 No Yes 9/23/2004 66,533 11.197 0.943 0.000 No 473.9 6.2 No Yes 12/9/2004 68,501 11.477 1.067 0.000 No 444.2 6.1 No Yes 4/21/2005 71,916 12.060 0.917 0.000 No 484.4 6.2 No Yes 5/31/2005 72,935 12.224 1.113 0.000 No 435.2 6.1 No Yes 9/15/2005 75,657 12.777 1.068 0.000 No 407.5 6.0 No Yes 1/12/2006 78,683 13.562 1.073 0.000 No 379.8 5.9 No Yes 3/24/2006 79,470 13.886 1.076 0.000 No 352.9 5.9 No Yes 9/21/2006 84,063 14.709 1.052 0.000 No 335.5 5.8 No Yes 10/26/2006 84,957 14.914 1.053 0.000 No 318.6 5.8 No Yes String No.: 15 Serial No. : 99SO6335 Cycle Installed:

9 Coordinates: 41 Type : NA300 Cumulative Core Average Exposure at BOC:

54,800 Level: A LPRM ID No. : 345 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.004 1.099 0.000 No 1,137.4 7.0 No Yes 11/30/1999 149 0.034 1.116 0.000 No 1,019.2 6.9 No Yes 3/8/2000 2,584 0.643 1.053 0.000 No 967.9 6.9 No Yes

8/24/2000 6,865 1.986 1.086 0.000 No 891.2 6.8 No Yes 11/4/2000 8,649 2.468 1.106 0.000 No 805.8 6.7 No Yes 1/18/2001 10,585 2.843 1.062 0.000 No 758.8 6.6 No Yes 3/22/2001 12,131 3.254 1.067 0.000 No 711.1 6.6 No Yes 4/26/2001 13,036 3.507 1.051 0.000 No 677.0 6.5 No Yes 617/2001 14,125 3.796 1.050 0.000 No 644.8 6.5 No Yes 7/7/2001 14,896 3.979 1.140 0.000 No 565.6 6.3 No Yes 9/13/2001 16,661 4.359 1.053 0.000 No 537.1 6.3 No Yes 2/14/2002 17,687 5.000 0.946 0.000 No 567.8 6.3 No Yes 6/6/2002 17,723 5.794 1.061 0.000 No 508.0 6.2 No Yes 12/5/2002 22,366 6.978 1.061 0.000 No 478.8 6.2 No Yes 4/10/2003 25,544 7.967 1.053 0.000 No 454.7 6.1 No Yes 6/19/2003 27,228 8.515 1.051 0.000 No 432.6 6.1 No Yes 7/30/2003 28,292 8.835 1.016 0.000 No 433.0 6.1 No Yes 10/16/2003 30,289 9.316 1.054 0.000 No 410.8 6.0 No Yes 3/25/2004 37,343 9.978 1.053 0.000 No 390.1 6.0 No Yes 8/12/2004 40,920 11.076 1.069 0.000 No 365.0 5.9 No Yes 12/9/2004 43,958 12.121 1.069 0.000 No 341.4 5.8 No Yes 3/17/2005 46,469 13.046 1.054 0.000 No 323.9 5.8 No Yes 9/15/2005 51,114 14.693 1.071 0.000 No 302.0 5.7 No Yes 10/20/2005 52,015 14.912 1.079 0.000 No 280.0 5.6 No Yes 12/1/2005 53,067 15.070 0.875 0.000 No 320.0 5.8 No Yes 1/12/2006 54,140 15.244 1.041 0.000 No 300.0 5.7 No Yes 3/24/2006 54,927 15.431 1.128 0.000 No 266.0 5.6 No Yes 9/21/2006 59,520 16.733 1.115 0.000 No 238.5 5.5 No Yes 10/26/2006 60,414 16.966 0.979 0.000 No 243.6 5.5 No Yes Level: B LPRM ID No. : 351 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.005 1.112 0.000 No 1,124.1 7.0 No Yes 12/27/1999 816 0.236 1.073 0.000 No 1,047.6 7.0 No Yes 8/24/2000 6,865 2.089 1.087 0.000 No 963.8 6.9 No Yes 11/4/2000 8,649 2.615 1.065 0.000 No 905.0 6.8 No Yes 1/18/2001 10,585 3.092 1.107 0.000 No 817.5 6.7 No Yes 4/26/2001 13,036 3.736 1.078 0.000 No 758.3 6.6 No Yes 617/2001 14,125 4.027 1.056 0.000 No 718.1 6.6 No Yes 7/7/2001 14,896 4.230 1.116 0.000 No 643.5 6.5 No Yes

9/13/2001 16,661 4.670 1.063 0.000 No 605.3 6.4 No Yes 6/6/2002 17,723 6.257 1.048 0.000 No 543.0 6.3 No Yes 11/15/2001 18,288 5.063 1.057 0.000 No 572.7 6.4 No Yes 8/15/2002 19,529 6.749 1.084 0.000 No 500.9 6.2 No Yes 12/5/2002 22,366 7.520 1.056 0.000 No 474.4 6.2 No Yes 4/10/2003 25,544 8.440 1.054 0.000 No 450.1 6.1 No Yes 6/19/2003 27,228 8.906 1.058 0.000 No 425.4 6.1 No Yes 7/30/2003 28,292 9.202 1.006 0.000 No 425.0 6.1 No Yes 11/20/2003 31,194 9.934 1.066 0.000 No 398.7 6.0 No Yes 2/19/2004 36,454 10.262 1.108 0.000 No 359.8 5.9 No Yes 9/23/2004 41,990 11.835 1.084 0.000 No 331.9 5.8 No Yes 4/21/2005 47,373 13.339 1.081 0.000 No 307.1 5.7 No Yes 9/15/2005 51,114 14.408 1.061 0.000 No 289.4 5.7 No Yes 1/12/2006 54,140 15.222 1.059 0.000 No 273.3 5.6 No Yes 3/24/2006 54,927 15.514 1.096 0.000 No 249.4 5.5 No Yes 9/21/2006 59,520 16.876 1.064 0.000 No 234.4 5.5 No Yes 10/26/2006 60,414 17.134 1.003 0.000 No 233.7 5.5 No Yes Level: C LPRM ID No.: 357 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 7/7/2001 14,896 3.366 1.103 0.000 No 1,133.3 7.0 No Yes 10/18/2001 17,564 4.033 1.052 0.000 No 1,077.3 7.0 No Yes 9/19/2002 20,399 5.687 1.058 0.000 No 1,018.2 6.9 No Yes 1/16/2003 23,420 6.498 1.072 0.000 No 949.8 6.9 No Yes 6/19/2003 27,228 7.301 1.064 0.000 No 892.7 6.8 No Yes 7/30/2003 28,292 7.555 1.034 0.000 No 893.0 6.8 No Yes 9/11/2003 29,387 7.832 1.071 0.000 No 833.8 6.7 No Yes 12/30/2003 32,121 8.564 1.070 0.000 No 779.3 6.7 No Yes 2/19/2004 36,454 8.697 1.099 0.000 No 709.1 6.6 No Yes 8/12/2004 40,920 9.692 1.077 0.000 No 658.4 6.5 No Yes 1/6/2005 44,679 10.564 1.060 0.000 No 621.1 6.4 No Yes 5/31/2005 48,392 11.443 1.071 0.000 No 579.9 6.4 No Yes 9/15/2005 51,114 12.188 1.074 0.000 No 540.0 6.3 No Yes 1/12/2006 54,140 13.091 1.090 0.000 No 495.4 6.2 No Yes 3/24/2046 54,927 13.418 1.137 0.000 No 435.7 6.1 No Yes 7/13/2006 57,733 14.117 1.051 0.000 No 414.5 6.0 No Yes 9/21/2006 59,520 14.581 1.071 0.000 No 387.1 6.0 No Yes

10/26/2006 Level:

60,414 D

14.790 LPRM ID No.:

1.007 363 0.000 Beginning No 384.4 of Life Calibration Current :

6.0 No 1,250.0 Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.002 1.119 0.000 No 1,117.1 7.0 No Yes 12/27/1999 816 0.128 1.077 0.000 No 1,037.2 6.9 No Yes 1/18/2001 10,585 1.887 1.100 0.000 No 942.9 6.8 No Yes 4/26/2001 13,036 2.381 1.071 0.000 No 880.4 6.8 No Yes 7/7/2001 14,896 2.707 1.087 0.000 No 809.9 6.7 No Yes 9/13/2001 16,661 3.116 1.078 0.000 No 751.3 6.6 No Yes 11/15/2001 18,288 3.481 1.079 0.000 No 696.3 6.5 No Yes 12/5/2002 22,366 4.507 1.070 0.000 No 650.8 6.5 No Yes 7/30/2003 28,292 5.155 1.050 0.000 No 651.0 6.5 No Yes 9/11/2003 29,387 5.307 1.070 0.000 No 608.4 6.4 No Yes 2/19/2004 36,454 5.870 1.077 0.000 No 564.9 6.3 No Yes 5/6/2004 38,423 6.107 1.077 0.000 No 524.5 6.3 No Yes 6/17/2004 39,500 6.259 0.946 0.000 No 554.5 6.3 No Yes 9/23/2004 41,990 6.662 1.078 0.000 No 514.3 6.2 No Yes 12/9/2004 43,958 6.957 0.934 0.000 No 550.7 6.3 No Yes 2/3/2005 45,396 7.190 1.054 0.000 No 522.5 6.3 No Yes 4/21/2005 47,373 7.519 1.077 0.000 No 485.1 6.2 No Yes 9/15/2005 51,114 8.304 1.061 0.000 No 457.2 6.1 No Yes 10/20/2005 52,015 8.520 0.936 0.000 No 488.0 6.2 No Yes 1/12/2006 54,140 9.067 1.101 0.000 No 443.2 6.1 No Yes 3/24/2006 54,927 9.382 1.065 0.000 No 416.2 6.0 No Yes 7/13/2006 57,733 9.851 1.064 0.000 No 391.1 6.0 No Yes 10/26/2006 60,414 10.422 1.016 0.000 No 385.0 6.0 No Yes String No.: 16 Serial No. : 99SO6332 Cycle Installed:

9 Coordinates: 41 Type : NA300 Cumulative Core Average Exposure at BOC:

54,800 Level: A LPRM ID No. : 346 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.003 1.111 0.000 No 1,125.1 7.0 No Yes 11/30/1999 149 0.035 1.064 0.000 No 1,057.4 7.0 No Yes 12/27/1999 816 0.222 1.058 0.000 No 999.5 6.9 No Yes 4/12/2000 3,445 0.946 1.052 0.000 No 950.1 6.9 No Yes

8/24/2000 6,865 1.772 1.077 0.000 No 882.1 6.8 No Yes 11/4/2000 8,649 2.174 1.081 0.000 No 816.0 6.7 No Yes 1/18/2001 10,585 2.579 1.074 0.000 No 759.8 6.6 No Yes 4/26/2001 13,036 3.244 1.109 0.000 No 685.1 6.5 No Yes 7/7/2001 14,896 3.723 1.087 0.000 No 630.3 6.4 No Yes 10/18/2001 17,564 4.374 1.082 0.000 No 582.5 6.4 No Yes 2/14/2002 17,687 4.944 1.102 0.000 No 528.6 6.3 No Yes 8/15/2002 19,529 6.250 1.063 0.000 No 497.3 6.2 No Yes 12/5/2002 22,366 7.120 1.063 0.000 No 467.8 6.1 No Yes 2/26/2003 24,474 7.793 1.075 0.000 No 435.2 6.1 No Yes 5/15/2003 26,390 8.454 1.066 0.000 No 408.2 6.0 No Yes 7/30/2003 28,292 9.133 1.041 0.000 No 408.0 6.0 No Yes 9/11/2003 29,387 9.461 1.056 0.000 No 386.4 6.0 No Yes 2/19/2004 36,454 10.209 1.059 0.000 No 364.8 5.9 No Yes 5/6/2004 38,423 10.881 1.083 0.000 No 336.9 5.8 No Yes 6/17/2004 39,500 11.252 1.052 0.000 No 320.2 5.8 No Yes 12/9/2004 43,958 12.591 1.056 0.000 No 303.2 5.7 No Yes 1/6/2005 44,679 12.832 0.937 0.000 No 323.6 5.8 No Yes 2/3/2005 45,396 13.081 1.097 0.000 No 295.0 5.7 No Yes 3/17/2005 46,469 13.430 0.947 0.000 No 311.5 5.7 No Yes 5/31/2005 48,392 14.083 1.089 0.000 No 286.1 5.7 No Yes 8/4/2005 50,051 14.610 0.931 0.000 No 307.3 5.7 No Yes 9/15/2005 51,114 14.888 1.072 0.000 No 286.6 5.7 No Yes 3124/2006 54,927 15.808 1.150 0.000 No 249.2 5.5 No Yes 7/13/2006 57,733 16.656 1.075 0.000 No 231.9 5.4 No Yes 10/26/2006 60,414 17.495 1.070 0.000 No 216.7 5.4 No Yes Level: B LPRM ID No.: 352 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/30/1999 149 0.044 1.050 0.000 No 1,190.5 7.1 No Yes 1/18/2001 10,585 2.833 1.049 0.000 No 1,134.9 7.0 No Yes 7/7/2001 14,896 3.926 1.078 0.000 No 1,052.8 7.0 No Yes 10/18/2001 17,564 4.597 1.076 0.000 No 978.4 6.9 No Yes 2/14/2002 17,687 5.256 1.078 0.000 No 907.6 6.8 No Yes 8/15/2002 19,529 6.541 1.052 0.000 No 862.7 6.8 No Yes 12/5/2002 22,366 7.425 1.087 0.000 No 793.7 6.7 No Yes 2/26/2003 24,474 8.053 1.069 0.000 No 742.5 6.6 No Yes

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Good Value Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Level: D LPRM ID No. : 364 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Level: C LPRM ID No.: 358 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

4/12/2000 3,445 0.757 0.943 0.000 No 1,325.6 7.2 No 7/7/2001 14,896 3.360 1.067 0.000 No 1,242.3 7.1 No 10/18/2001 17,564 4.003 1.069 0.000 No 1,162.1 7.1 No 3/29/2002 18,770 4.875 1.060 0.000 No 1,084.0 7.0 No 9/19/2002 20,399 5.674 1.052 0.000 No 1,030.4 6.9 No 12/5/2002 22,366 6.136 1.053 0.000 No 978.6 6.9 No 5/15/2003 26,390 6.998 1.051 0.000 No 931.1 6.8 No 7/30/2003 28,292 7.471 1.051 0.000 No 885.9 6.8 No 10/16/2003 30,289 8.030 1.063 0.000 No 833.4 6.7 No 2/19/2004 36,454 8.746 1.164 0.000 No 716.0 6.6 No 6/17/2004 39,500 9.444 1.057 0.000 No 677.4 6.5 No 12/9/2004 43,958 10.404 1.056 0.000 No 641.4 6.5 No 3/17/2005 46,469 10.970 1.057 0.000 No 606.8 6.4 No 6/30/2005 49,160 11.543 1.058 0.000 No 573.6 6.4 No 9/15/2005 51,114 12.025 1.052 0.000 No 545.2 6.3 No 1/12/2006 54,140 12.918 1.067 0.000 No 511.0 6.2 No 3/24/2006 54,927 13.251 1.121 0.000 No 455.8 6.1 No 6/8/2006 56,839 13.655 1.082 0.000 No 421.3 6.0 No 10/26/2006 60,414 14.488 1.049 0.000 No 401.6 6.0 No 6/19/2003 27,228 8.844 1.056 0.000 No 703.1 6.6 No 7/30/2003 28,292 9.167 1.035 0.000 No 703.0 6.6 No 9/11/2003 29,387 9.487 1.056 0.000 No 665.7 6.5 No 11/20/2003 31,194 10.001 1.052 0.000 No 632.8 6.5 No 2/19/2004 36,454 10.386 1.175 0.000 No 538.6 6.3 No 6/17/2004 39,500 11.299 1.053 0.000 No 511.5 6.2 No 12/9/2004 43,958 12.460 1.054 0.000 No 485.3 6.2 No 3/17/2005 46,469 13.096 1.079 0.000 No 449.7 6.1 No 9/15/2005 51,114 14.254 1.065 0.000 No 422.3 6.0 No 1/12/2006 54,140 15.083 1.058 0.000 No 399.1 6.0 No 3/24/2006 54,927 15.394 1.099 0.000 No 363.2 5.9 No 8/17/2006 58,629 16.463 1.066 0.000 No 340.7 5.8 No 10/26/2006 60,414 16.992 1.038 0.000 No 328.2 5.8 No

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/30/1999 149 0.021 1.117 0.000 No 1,119.1 7.0 No Yes 4/12/2000 3,445 0.476 0.937 0.000 No 1,194.3 7.1 No Yes 3/29/2002 18,770 3.681 1.050 0.000 No 1,137.4 7.0 No Yes 7/30/2003 28,292 4.809 1.018 0.000 No 1,137.0 7.0 No Yes 11/20/2003 31,194 5.273 1.111 0.000 No 1,023.4 6.9 No Yes 2/19/2004 36,454 5.553 1.094 0.000 No 935.5 6.8 No Yes 3/25/2004 37,343 5.643 1.074 0.000 No 871.0 6.8 No Yes 6/17/2004 39,500 5.891 0.926 0.000 No 940.6 6.8 No Yes 12/9/2004 43,958 6.516 1.102 0.000 No 853.6 6.7 No Yes 1/6/2005 44,679 6.637 1.122 0.000 No 760.7 6.6 No Yes 2/3/2005 45,396 6.760 0.933 0.000 No 815.4 6.7 No Yes 3/17/2005 46,469 6.949 1.089 0.000 No 748.7 6.6 No Yes 8/4/2005 50,051 7.580 1.096 0.000 No 683.2 6.5 No Yes 10/20/2005 52,015 8.026 1.093 0.000 No 625.0 6.4 No Yes 1/12/2006 54,140 8.554 1.084 0.000 No 576.6 6.4 No Yes 6/8/2006 56,839 9.111 1.100 0.000 No 524.2 6.3 No Yes 10/26/2006 60,414 9.685 1.007 0.000 No 520.5 6.3 No Yes String No.: 17 Serial No. : L-2703 Cycle Installed:

7 Coordinates: 41 Type : NA300 Cumulative Core Average Exposure at BOC:

79,343 Level: A LPRM ID No. : 60 Beginning of Life Calibration Current:

1,188.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 1.878 1.033 0.000 Yes 1,028.0 6.9 No Yes 8/25/1998 14,963 1.971 0.990 0.000 No 1,038.4 6.9 No Yes 9/29/1998 15,824 2.104 1.019 0.000 No 1,019.0 6.9 No Yes 4/15/1999 20,444 2.754 1.047 0.000 No 973.3 6.9 No Yes 8/4/1999 22,908 3.106 1.045 0.000 No 931.4 6.8 No Yes 11/24/1999 24,556 3.274 1.124 0.000 No 828.6 6.7 No Yes 12/27/1999 25,359 3.413 1.039 0.000 No 797.5 6.7 No Yes 2/2/2000 26,267 3.571 1.061 0.000 No 779.0 6.7 No Yes 5/10/2000 28,679 4.024 1.052 0.000 No 740.5 6.6 No Yes 7/20/2000 30,502 4.410 1.057 0.000 No 700.6 6.6 No Yes 11/4/2000 33,192 4.955 1.055 0.000 No 664.0 6.5 No Yes 1/18/2001 35,128 5.428 1.070 0.000 No 620.6 6.4 No Yes 6/7/2001 38,668 6.126 1.054 0.000 No 588.8 6.4 No Yes

Level : B LPRM ID No. : 146 Beginning of Life Calibration Current:

1,172.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 2.585 1.052 0.000 Yes 915.0 6.8 No Yes 8/25/1998 14,963 2.689 0.981 0.000 No 932.7 6.8 No Yes 9/29/1998 15,824 2.875 1.040 0.000 No 896.8 6.8 No Yes 2/4/1999 18,757 3.486 1.071 0.000 No 837.4 6.7 No Yes 4/15/1999 20,444 3.812 1.048 0.000 No 799.0 6.7 No Yes 8/4/1999 22,908 4.240 1.050 0.000 No 761.0 6.6 No Yes 11/24/1999 24,556 4.483 1.150 0.000 No 661.7 6.5 No Yes 2/2/2000 26,267 4.838 1.051 0.000 No 629.6 6.4 No Yes 5/10/2000 28,679 5.350 1.052 0.000 No 598.5 6.4 No Yes 8/24/2000 31,408 5.931 1.056 0.000 No 566.8 6.3 No Yes 1/18/2001 35,128 6.731 1.066 0.000 No 531.7 6.3 No Yes 3/22/2001 36,674 7.023 1.022 0.000 No 520.2 6.3 No Yes 8/17/2001 40,505 7.773 1.077 0.000 No 483.0 6.2 No Yes 2/14/2002 42,230 8.616 1.075 0.000 No 449.3 6.1 No Yes 10/24/2002 45,842 10.029 1.075 0.000 No 418.0 6.0 No Yes 6/19/2003 51,771 11.459 1.061 0.000 No 394.0 6.0 No Yes 7/30/2003 52,835 11.715 1.033 0.000 No 394.0 6.0 No Yes 10/16/2003 54,832 12.185 1.059 0.000 No 372.0 5.9 No Yes 8/17/2001 40,505 6.533 1.061 0.000 No 555.0 6.3 No Yes 3/29/2002 43,313 7.520 1.118 0.000 No 496.4 6.2 No Yes 10/24/2002 45,842 8.610 1.051 0.000 No 472.3 6.2 No Yes 4/10/2003 50,087 9.634 1.063 0.000 No 444.3 6.1 No Yes 7/30/2003 52,835 10.407 1.025 0.000 No 444.0 6.1 No Yes 9/11/2003 53,930 10.668 1.066 0.000 No 416.5 6.0 No Yes 2/19/2004 60,997 11.272 1.090 0.000 No 382.1 5.9 No Yes 7/15/2004 64,743 11.892 1.082 0.000 No 353.2 5.9 No Yes 12/9/2004 68,501 12.689 0.902 0.000 No 391.5 6.0 No Yes 1/6/2005 69,222 12.773 1.060 0.000 No 369.4 5.9 No Yes 2/3/2005 69,939 12.859 0.947 0.000 No 390.0 6.0 No Yes 3/17/2005 71,012 13.054 1.075 0.000 No 362.8 5.9 No Yes 4/21/2005 71,916 13.222 1.077 0.000 No 336.9 5.8 No Yes 1/12/2006 78,683 14.342 0.944 0.000 No 356.9 5.9 No Yes 3/24/2006 79,470 14.474 1.139 0.000 No 313.3 5.7 No Yes 10/26/2006 84,957 15.539 1.054 0.000 No 297.3 5.7 No Yes

Level : C LPRM ID No. : 232 Beginning of Life Calibration Current:

1,102.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/1211996 13,460 2.720 1.067 0.000 Yes 894.0 6.8 No Yes 12/29/1998 17,872 3.311 1.012 0.000 No 879.0 6.8 No Yes 3/11/1999 19,616 3.625 1.074 0.000 No 821.0 6.7 No Yes 8/4/1999 22,908 4.238 1.089 0.000 No 753.9 6.6 No Yes 11/24/1999 24,556 4.563 1.153 0.000 No 653.9 6.5 No Yes 3/8/2000 27,127 4.970 1.076 0.000 No 607.7 6.4 No Yes 11/4/2000 33,192 5.934 1.058 0.000 No 574.4 6.4 No Yes 3/22/2001 36,674 6.578 1.072 0.000 No 535.8 6.3 No Yes 8/17/2001 40,505 7.394 1.076 0.000 No 497.9 6.2 No Yes 2/14/2002 42,230 8.210 1.062 0.000 No 468.9 6.2 No Yes 6/19/2003 51,771 9.943 1.051 0.000 No 446.1 6.1 No Yes 7/30/2003 52,835 10.130 1.030 0.000 No 446.0 6.1 No Yes 11/20/2003 55,737 10.712 1.066 0.000 No 418.4 6.0 No Yes 2/19/2004 60,997 11.041 1.197 0.000 No 349.5 5.9 No Yes 3/17/2005 71,012 12.794 1.052 0.000 No 332.3 5.8 No Yes 6/30/2005 73,703 13.238 1.051 0.000 No 316.1 5.8 No Yes 1/1212006 78,683 14.204 1.069 0.000 No 295.7 5.7 No Yes 3/24/2006 79,470 14.424 1.052 0.000 No 281.1 5.6 No Yes 9/21/2006 84,063 15.212 1.051 0.000 No 267.5 5.6 No Yes 10/26/2006 84,957 15.357 0.981 0.000 No 272.6 5.6 No Yes Level: D LPRM ID No.: 318 Beginning of Life Calibration Current:

1,268.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 13,460 2.145 1.034 0.000 Yes 1,039.0 6.9 No Yes 8/25/1998 14,963 2.171 0.962 0.000 No 1,080.0 7.0 No Yes 9/29/1998 15,824 2.264 1.015 0.000 No 1,064.1 7.0 No Yes 3/11/1999 19,616 2.722 1.049 0.000 No 1,013.0 6.9 No Yes 2/19/2004 60,997 12.699 1.174 0.000 No 316.9 5.8 No Yes 7/15/2004 64,743 13.411 1.053 0.000 No 301.0 5.7 No Yes 3/17/2005 71,012 14.602 1.070 0.000 No 281.3 5.6 No Yes 9/15/2005 75,657 15.452 1.069 0.000 No 263.1 5.6 No Yes 3/24/2006 79,470 16.199 1.096 0.000 No 240.1 5.5 No Yes 9/21/2006 84,063 17.172 1.058 0.000 No 226.9 5.4 No Yes 10/26/2006 84,957 17.351 0.991 0.000 No 229.0 5.4 No Yes

6/24/1999 22,047 3.041 1.049 0.000 No 965.7 6.9 No Yes 11/24/1999 24,556 3.449 1.131 0.000 No 853.8 6.7 No Yes 12/27/1999 25,359 3.515 1.050 0.000 No 813.2 6.7 No Yes 7/20/2000 30,502 3.962 1.061 0.000 No 766.4 6.6 No Yes 3/22/2001 36,674 4.626 1.072 0.000 No 714.9 6.6 No Yes 2/14/2002 42,230 5.707 1.126 0.000 No 634.9 6.5 No Yes 2/26/2003 49,017 6.201 0.928 0.000 No 684.2 6.5 No Yes 7/30/2003 52,835 6.465 1.049 0.000 No 684.0 6.5 No Yes 2/19/2004 60,997 6.931 1.073 0.000 No 637.5 6.5 No Yes 8/12/2004 65,463 7.459 1.053 0.000 No 605.4 6.4 No Yes 12/9/2004 68,501 7.858 1.108 0.000 No 546.4 6.3 No Yes 12/1/2005 77,610 9.437 1.087 0.000 No 502.6 6.2 No Yes 6/8/2006 81,382 10.100 1.070 0.000 No 469.8 6.2 No Yes 10/26/2006 84,957 10.562 0.978 0.000 No 480.3 6.2 No Yes String No. : 18 Serial No.: 03861361 Cycle Installed:

11 Coordinates: 33 Type : NA300 Cumulative Core Average Exposure at BOC:

18,500 Level: A LPRM ID No.: 501 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/25/2004 1,043 0.306 1.118 0.000 No 1,118.1 7.0 No Yes 8/12/2004 4,620 1.249 0.919 0.000 No 1,216.6 7.1 No Yes 3/17/2005 10,169 3.003 1.063 0.000 No 1,144.5 7.0 No Yes 10/20/2005 15,715 4.745 1.125 0.000 No 1,017.0 6.9 No Yes 12/1/2005 16,767 5.009 0.936 0.000 No 1,086.5 7.0 No Yes 3/24/2006 18,627 5.453 1.166 0.000 No 931.9 6.8 No Yes 10/26/2006 24,114 6.945 0.999 0.000 No 932.8 6.8 No Yes Level: B LPRM ID No.: 511 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 9/23/2004 5,690 1.459 0.929 0.000 No 1,345.5 7.2 No Yes 3/17/2005 10,169 2.643 0.944 0.000 No 1,425.4 7.3 No Yes 1/12/2006 17,840 4.653 1.078 0.000 No 1,322.2 7.2 No Yes 3/24/2006 18,627 4.951 1.161 0.000 No 1,138.9 7.0 No Yes 10/26/2006 24,114 6.365 0.998 0.000 No 1,141.1 7.0 No Yes

Level: C LPRM ID No.: 521 Beginning of Life Calibration Current:

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 7.2 7.3 7.2 7.1 7.1 7.3 7.2 7.3 7.3 7.4 7.3 7.4 7.2 7.3 7.3 7.3 8

7.0 7.1 7.1 7.0 6.9 6.9 6.8 6.7 6/17/2004 1/6/2005 3/24/2006 10/26/2006 3,200 8,379 18,627 24,114 0.660 1.742 4.444 5.631 0.924 0.933 1.133 1.021 0.000 0.000 0.000 0.000 No No No No 1,352.8 1,450.0 1,279.8 1,253.4 Level: D LPRM ID No.: 531 Beginning of Life Calibration Current :

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 3/25/2004 1,043 0.099 0.854 0.000 No 1,463.7 5/6/2004 2,123 0.204 1.056 0.000 No 1,386.1 9/23/2004 5,690 0.667 0.948 0.000 No 1,462.1 3/17/2005 10,169 1.368 0.943 0.000 No 1,550.5 10/20/2005 15,715 2.347 0.940 0.000 No 1,649.0 12/1/2005 16,767 2.598 1.075 0.000 No 1,534.0 1/1212006 17,840 2.866 0.947 0.000 No 1,619.8 3/24/2006 18,627 3.143 1.155 0.000 No 1,402.4 5/4/2006 19,675 3.286 0.935 0.000 No 1,499.9 6/8/2006 20,539 3.433 1.065 0.000 No 1,408.4 10/26/2006 24,114 4.169 0.996 0.000 No 1,414.0 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes String No.: 19 Serial No. : 95SO1707 Cycle Installed:

Coordinates:

Level:

33 A

Type :

LPRM ID No. :

NA300 62 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 9/12/1996 1,276 0.623 1.023 0.000 Yes 1,120.0 8/25/1998 2,824 0.710 0.971 0.000 No 1,153.5 9/29/1998 3,685 0.942 0.993 0.000 No 1,161.6 3/11/1999 7,477 2.020 1.067 0.000 No 1,086.0 6/24/1999 9,908 2.715 1.085 0.000 No 1,000.9 9/17/1999 11,716 3.209 1.060 0.000 No 944.3 11/24/1999 12,417 3.352 1.097 0.000 No 860.8 212/2000 14,128 3.640 1.064 0.000 No 809.0 67,204 1,148.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes

5/10/2000 16,540 4.195 1.076 0.000 No 751.9 6.6 No Yes 7/20/2000 18,363 4.683 1.076 0.000 No 698.7 6.5 No Yes 9/28/2000 20,178 5.089 1.068 0.000 No 654.3 6.5 No Yes 12/7/2000 21,903 5.404 1.059 0.000 No 617.8 6.4 No Yes 2/22/2001 23,810 5.814 1.022 0.000 No 574.0 6.4 No Yes 4/26/2001 25,440 6.251 1.052 0.000 No 557.0 6.3 No Yes 8/17/2001 28,366 6.954 1.063 0.000 No 524.0 6.3 No Yes 2/14/2002 30,091 7.868 1.067 0.000 No 460.2 6.1 No Yes 3/29/2002 31,174 8.234 1.051 0.000 No 437.9 6.1 No Yes 12/20/2001 31,587 7.705 1.067 0.000 No 491.1 6.2 No Yes 9/19/2002 32,803 9.468 1.067 0.000 No 410.4 6.0 No Yes 2/26/2003 36,878 10.494 1.085 0.000 No 378.3 5.9 No Yes 6/19/2003 39,632 11.558 1.070 0.000 No 353.5 5.9 No Yes 7/30/2003 40,696 11.819 1.022 0.000 No 354.0 5.9 No Yes 11/20/2003 43,598 12.602 1.071 0.000 No 330.5 5.8 No Yes 3/25/2004 49,747 13.158 1.109 0.000 No 298.0 5.7 No Yes 9/23/2004 54,394 14.675 1.097 0.000 No 271.7 5.6 No Yes 10/28/2004 55,295 14.996 0.947 0.000 No 286.9 5.7 No Yes 1/6/2005 57,083 15.606 1.092 0.000 No 262.7 5.6 No Yes 2/3/2005 57,800 15.846 0.932 0.000 No 281.9 5.6 No Yes 3/17/2005 58,873 16.219 1.118 0.000 No 252.1 5.5 No Yes 4/21/2005 59,777 16.545 0.920 0.000 No 274.1 5.6 No Yes 5/31/2005 60,796 16.920 1.150 0.000 No 238.3 5.5 No Yes 6/30/2005 61,564 17.221 0.924 0.000 No 257.9 5.6 No Yes 1/12/2006 66,544 18.336 1.038 0.000 No 245.0 5.5 No Yes 3/24/2006 67,331 18.559 1.144 0.000 No 214.2 5.4 No Yes 6/8/2006 69,243 19.207 1.056 0.000 No 202.8 5.3 No Yes 10/26/2006 72,818 20.270 1.057 0.000 No 191.9 5.3 No Yes Level: B LPRM ID No. : 148 Beginning of Life Calibration Current:

1,160.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/1211996 1,276 0.708 0.986 0.000 Yes 1,159.0 7.1 No Yes 8/25/1998 2,824 0.733 1.000 0.000 No 1,159.0 7.1 No Yes 9/29/1998 3,685 0.974 1.006 0.000 No 1,152.1 7.0 No Yes 2/4/1999 6,618 1.852 1.046 0.000 No 1,115.0 7.0 No Yes 3/11/1999 7,477 2.085 1.094 0.000 No 1,070.0 7.0 No Yes 4/15/1999 8,305 2.308 1.098 0.000 No 974.5 6.9 No Yes

8/4/1999 10,769 3.028 1.072 0.000 No 909.0 6.8 No Yes 9/17/1999 11,716 3.320 1.133 0.000 No 802.3 6.7 No Yes 11/24/1999 12,417 3.535 1.076 0.000 No 745.7 6.6 No Yes 12/27/1999 13,220 3.722 1.058 0.000 No 704.8 6.6 No Yes 3/22/2001 24,535 6.438 1.331 0.000 No 531.0 6.3 No Yes 8/17/2001 28,366 7.334 1.056 0.000 No 502.8 6.2 No Yes 10/18/2001 29,968 7.714 1.053 0.000 No 477.5 6.2 No Yes 2/14/2002 30,091 8.337 1.107 0.000 No 431.4 6.1 No Yes 6/6/2002 30,127 9.164 0.999 0.000 No 403.0 6.0 No Yes 9/19/2002 32,803 9.901 1.074 0.000 No 375.2 5.9 No Yes 4/10/2003 37,948 11.401 1.080 0.000 No 347.4 5.9 No Yes 7/30/2003 40,696 12.158 1.055 0.000 No 329.3 5.8 No Yes 10/16/2003 42,693 12.701 1.052 0.000 No 313.0 5.7 No Yes 2/19/2004 48,858 13.329 1.191 0.000 No 262.8 5.6 No Yes 3/25/2004 49,747 13.591 1.056 0.000 No 248.9 5.5 No Yes 10/28/2004 55,295 15.227 1.052 0.000 No 236.6 5.5 No Yes 4/21/2005 59,777 16.437 1.059 0.000 No 223.4 5.4 No Yes 10/20/2005 64,419 17.755 1.060 0.000 No 211.0 5.4 No Yes 1/12/2006 66,544 18.285 1.036 0.000 No 198.0 5.3 No Yes 3/24/2006 67,331 18.603 1.122 0.000 No 176.5 5.2 No Yes 10/26/2006 72,818 20.300 1.065 0.000 No 165.7 5.1 No Yes Level: C LPRM ID No.: 234 Beginning of Life Calibration Current:

1,156.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.592 0.992 0.000 Yes 1,159.0 7.1 No Yes 8/25/1998 2,824 0.589 0.964 0.000 No 1,202.3 7.1 No Yes 9/29/1998 3,685 0.768 1.008 0.000 No 1,192.7 7.1 No Yes 2/4/1999 6,618 1.547 0.946 0.000 No 1,260.8 7.1 No Yes 6/24/1999 9,908 2.508 1.109 0.000 No 1,136.9 7.0 No Yes 9/17/1999 11,716 3.066 1.096 0.000 No 1,037.3 6.9 No Yes 11/24/1999 12,417 3.307 1.126 0.000 No 921.2 6.8 No Yes 12/27/1999 13,220 3.472 1.068 0.000 No 862.6 6.8 No Yes 3/8/2000 14,988 3.805 1.061 0.000 No 813.0 6.7 No Yes 5/10/2000 16,540 4.099 1.062 0.000 No 765.5 6.6 No Yes 7/20/2000 18,363 4.466 1.071 0.000 No 714.8 6.6 No Yes 11/4/2000 21,053 4.962 1.056 0.000 No 676.9 6.5 No Yes 3/22/2001 24,535 5.603 1.060 0.000 No 638.6 6.5 No Yes

Level: D LPRM ID No.: 320 Beginning of Life Calibration Current :

1,102.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/1211996 1,276 0.407 1.032 0.000 Yes 1,075.0 7.0 No Yes 8/25/1998 2,824 0.372 0.981 0.000 No 1,095.8 7.0 No Yes 9/29/1998 3,685 0.489 1.023 0.000 No 1,071.2 7.0 No Yes 3/11/1999 7,477 1.165 1.055 0.000 No 1,020.0 6.9 No Yes 6/24/1999 9,908 1.645 1.075 0.000 No 948.8 6.9 No Yes 9/17/1999 11,716 2.048 1.074 0.000 No 883.5 6.8 No Yes 11/24/1999 12,417 2.240 1.116 0.000 No 791.6 6.7 No Yes 2/2/2000 14,128 2.508 1.060 0.000 No 746.8 6.6 No Yes 6/14/2000 17,433 2.980 1.064 0.000 No 701.9 6.6 No Yes 12/7/2000 21,903 3.768 1.057 0.000 No 664.0 6.5 No Yes 4/26/2001 25,440 4.342 1.051 0.000 No 631.8 6.4 No Yes 2/14/2002 30,091 5.656 1.147 0.000 No 550.9 6.3 No Yes 7/30/2003 40,696 7.036 0.989 0.000 No 551.0 6.3 No Yes 9/11/2003 41,791 7.230 1.060 0.000 No 519.8 6.3 No Yes 2/19/2004 48,858 7.914 1.201 0.000 No 432.8 6.1 No Yes 3/25/2004 49,747 8.000 0.835 0.000 No 518.3 6.3 No Yes 7/15/2004 52,604 8.327 1.097 0.000 No 472.5 6.2 No Yes 8/12/2004 53,324 8.439 1.071 0.000 No 441.2 6.1 No Yes 9/23/2004 54,394 8.601 0.892 0.000 No 494.6 6.2 No Yes 10/18/2001 29,968 6.769 1.089 0.000 No 586.4 6.4 No Yes 2/14/2002 30,091 7.419 1.123 0.000 No 522.2 6.3 No Yes 6/6/2002 30,127 8.013 0.989 0.000 No 493.0 6.2 No Yes 12/5/2002 34,770 9.153 1.084 0.000 No 454.8 6.1 No Yes 5/15/2003 38,794 10.139 1.053 0.000 No 431.9 6.1 No Yes 7/30/2003 40,696 10.573 1.022 0.000 No 432.0 6.1 No Yes 9/11/2003 41,791 10.862 1.079 0.000 No 400.4 6.0 No Yes 11/20/2003 43,598 11.412 1.059 0.000 No 378.1 5.9 No Yes 2119/2004 48,858 11.854 1.154 0.000 No 327.6 5.8 No Yes 1/6/2005 57,083 13.771 1.075 0.000 No 304.8 5.7 No Yes 9/15/2005 63,518 15.394 1.066 0.000 No 285.9 5.7 No Yes 1211/2005 65,471 15.958 1.070 0.000 No 267.2 5.6 No Yes 3/24/2006 67,331 16.621 1.179 0.000 No 226.6 5.4 No Yes 7/13/2006 70,137 17.318 1.069 0.000 No 212.0 5.4 No Yes 10/26/2006 72,818 17.994 1.047 0.000 No 202.5 5.3 No Yes

10/28/2004 55,295 8.732 1.143 0.000 No 432.7 6.1 No Yes 1/6/2005 57,083 9.037 0.933 0.000 No 463.8 6.1 No Yes 223/2005 57,800 9.177 1.070 0.000 No 433.5 6.1 No Yes 3/17/2005 58,873 9.344 0.926 0.000 No 468.1 6.1 No Yes 4/21/2005 59,777 9.485 1.121 0.000 No 417.6 6.0 No Yes 5/31/2005 60,796 9.653 0.892 0.000 No 468.1 6.1 No Yes 6/30/2005 61,564 9.796 1.147 0.000 No 408.1 6.0 No Yes 9/15/2005 63,518 10.228 1.061 0.000 No 384.7 6.0 No Yes 1/12/2006 66,544 11.030 1.049 0.000 No 357.0 5.9 No Yes 6/8/2006 69,243 11.648 1.073 0.000 No 332.7 5.8 No Yes 8/17/2006 71,033 12.027 1.060 0.000 No 313.9 5.7 No Yes 10/26/2006 72,818 12.445 1.004 0.000 No 312.6 5.7 No Yes String No.: 20 Serial No. : 05005131 Cycle Installed:

12 Coordinates: 33 Type : NA300 Cumulative Core Average Exposure at BOC:

0 Level: A LPRM ID No. : 579 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2216/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.042 1.176 0.000 No 1,062.9 7.0 No Yes 6/8/2006 2,039 0.592 1.098 0.000 No 968.1 6.9 No Yes 10/26/2006 5,614 1.574 1.015 0.000 No 953.7 6.9 No Yes Level: B LPRM ID No. : 587 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.038 1.052 0.000 No 1,188.2 7.1 No Yes 10/26/2006 5,614 1.629 0.952 0.000 No 1,248.1 7.1 No Yes Level: C LPRM ID No.: 595 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/4/2006 1,175 0.254 1.093 0.000 No 1,143.6 7.0 No Yes 9/21/2006 4,720 1.079 0.946 0.000 No 1,208.9 7.1 No Yes 10/26/2006 5,614 1.319 0.987 0.000 No 1,224.8 7.1 No Yes Level: D LPRM ID No.: 603 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good

Date 2/16/2006 9/21/2006 10/26/2006 CAVEX 0

4,720 5,614 Exp GAF 0.000 1.000 0.884 0.932 1.104 1.007 GAFpost 0.000 0.000 0.000 Corrected CalCur No 1,250.0 No 1,341.2 No 1,331.9 7.1 7.2 7.2 Byp.?

No No No Value Yes Yes Yes String No. : 21 Serial No. : 99SO6333 Cycle Installed:

9 Coordinates: 33 Type : NA300 Cumulative Core Average Exposure at BOC:

54,800 Level : A LPRM ID No.: 347 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/30/1999 149 0.030 1.078 0.000 No 1,159.6 7.1 No Yes 12/7/2000 9,499 2.360 1.050 0.000 No 1,104.3 7.0 No Yes 7/7/2001 14,896 3.838 1.095 0.000 No 1,008.5 6.9 No Yes 6/6/2002 17,723 5.731 1.051 0.000 No 901.9 6.8 No Yes 3/29/2002 18,770 5.242 1.064 0.000 No 947.9 6.9 No Yes 4/10/2003 25,544 7.633 1.065 0.000 No 846.8 6.7 No Yes 6/19/2003 27,228 8.206 1.053 0.000 No 804.2 6.7 No Yes 7/30/2003 28,292 8.607 1.018 0.000 No 804.0 6.7 No Yes 9/11/2003 29,387 8.935 1.065 0.000 No 754.9 6.6 No Yes 2/19/2004 36,454 9.530 1.089 0.000 No 693.2 6.5 No Yes 5/6/2004 38,423 10.195 1.079 0.000 No 642.5 6.5 No Yes 6/17/2004 39,500 10.547 1.051 0.000 No 611.3 6.4 No Yes 10/28/2004 42,891 11.613 1.057 0.000 No 578.3 6.4 No Yes 12/9/2004 43,958 11.985 1.079 0.000 No 536.0 6.3 No Yes 3/17/2005 46,469 12.923 1.069 0.000 No 501.4 6.2 No Yes 4/21/2005 47,373 13.327 1.051 0.000 No 477.1 6.2 No Yes 6/30/2005 49,160 13.973 1.059 0.000 No 450.5 6.1 No Yes 8/4/2005 50,051 14.225 0.946 0.000 No 476.2 6.2 No Yes 9/15/2005 51,114 14.453 1.096 0.000 No 434.0 6.1 No Yes 12/1/2005 53,067 14.822 0.913 0.000 No 475.4 6.2 No Yes 1/12/2006 54,140 14.974 1.021 0.000 No 451.0 6.1 No Yes 10/26/2006 60,414 16.625 1.054 0.000 No 362.3 5.9 No Yes Level : B LPRM ID No.: 353 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/30/1999 149 0.040 1.095 0.000 No 1,141.6 7.0 No Yes 2/2/2000 1,724 0.461 1.050 0.000 No 1,087.2 7.0 No Yes

6/14/2000 5,029 1.401 1.061 0.000 No 1,024.7 6.9 No Yes 8/24/2000 6,865 1.932 1.092 0.000 No 938.4 6.8 No Yes 11/4/2000 8,649 2.411 1.091 0.000 No 860.1 6.8 No Yes 1/18/2001 10,585 2.826 1.108 0.000 No 776.3 6.7 No Yes 4/26/2001 13,036 3.504 1.093 0.000 No 710.2 6.6 No Yes 6/7/2001 14,125 3.818 1.050 0.000 No 676.4 6.5 No Yes 7/7/2001 14,896 4.039 1.069 0.000 No 632.7 6.5 No Yes 9/13/2001 16,661 4.507 1.052 0.000 No 601.5 6.4 No Yes 2/14/2002 17,687 5.324 1.065 0.000 No 533.8 6.3 No Yes 6/6/2002 17,723 6.122 1.083 0.000 No 492.9 6.2 No Yes 11/15/2001 18,288 4.905 1.058 0.000 No 568.5 6.3 No Yes 12/5/2002 22,366 7.357 1.062 0.000 No 464.1 6.1 No Yes 4/10/2003 25,544 8.172 1.072 0.000 No 432.9 6.1 No Yes 7/30/2003 28,292 8.998 1.045 0.000 No 433.0 6.1 No Yes 9/11/2003 29,387 9.314 1.074 0.000 No 403.2 6.0 No Yes 2/19/2004 36,454 10.077 1.118 0.000 No 360.6 5.9 No Yes 5/6/2004 38,423 10.691 1.052 0.000 No 342.8 5.8 No Yes 9/23/2004 41,990 11.707 1.074 0.000 No 319.2 5.8 No Yes 12/9/2004 43,958 12.304 1.056 0.000 No 302.2 5.7 No Yes 5/31/2005 48,392 13.675 1.055 0.000 No 286.5 5.7 No Yes 8/4/2005 50,051 14.179 1.067 0.000 No 268.5 5.6 No Yes 12/1/2005 53,067 15.056 1.065 0.000 No 252.1 5.5 No Yes 1/12/2006 54,140 15.345 1.013 0.000 No 238.0 5.5 No Yes 7/13/2006 57,733 16.448 1.051 0.000 No 206.6 5.3 No Yes 10/26/2006 60,414 17.174 1.015 0.000 No 203.6 5.3 No Yes Level: C LPRM ID No. : 359 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/30/1999 149 0.032 1.091 0.000 No 1,145.7 7.0 No Yes 2/14/2002 17,687 4.506 1.051 0.000 No 1,027.5 6.9 No Yes 11/15/2001 18,288 4.021 1.061 0.000 No 1,079.9 7.0 No Yes 9/19/2002 20,399 5.603 1.052 0.000 No 976.7 6.9 No Yes 2/26/2003 24,474 6.507 1.061 0.000 No 920.5 6.8 No Yes 7/30/2003 28,292 7.362 1.070 0.000 No 860.3 6.8 No Yes 10/16/2003 30,289 7.909 1.086 0.000 No 792.2 6.7 No Yes 2/19/2004 36,454 8.577 1.144 0.000 No 692.5 6.5 No Yes 5/6/2004 38,423 9.021 1.060 0.000 No 653.3 6.5 No Yes

Level: D LPRM ID No.: 365 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 17,687 3.479 1.054 0.000 No 1,186.0 7.1 No Yes 7/30/2003 28,292 4.877 1.040 0.000 No 1,186.0 7.1 No Yes 9/11/2003 29,387 5.054 1.054 0.000 No 1,125.2 7.0 No Yes 2/19/2004 36,454 5.677 1.066 0.000 No 1,055.6 7.0 No Yes 9/23/2004 41,990 6.450 1.139 0.000 No 926.8 6.8 No Yes 2/3/2005 45,396 7.153 1.089 0.000 No 851.0 6.7 No Yes 3/17/2005 46,469 7.378 0.905 0.000 No 940.3 6.8 No Yes 5/31/2005 48,392 7.777 1.062 0.000 No 885.4 6.8 No Yes 8/4/2005 50,051 8.146 1.091 0.000 No 811.6 6.7 No Yes 9/15/2005 51,114 8.433 0.941 0.000 No 862.0 6.8 No Yes 10/20/2005 52,015 8.676 1.063 0.000 No 811.0 6.7 No Yes 12/1/2005 53,067 9.004 1.079 0.000 No 751.6 6.6 No Yes 6/8/2006 56,839 9.990 1.079 0.000 No 623.6 6.4 No Yes 8/17/2006 58,629 10.403 1.061 0.000 No 587.8 6.4 No Yes 10/26/2006 60,414 10.881 1.056 0.000 No 556.6 6.3 No Yes String No.: 22 Serial No.: 0000723 Cycle installed:

10 Coordinates: 33 Type : NA300 Cumulative Core Average Exposure at BOC:

37,300 Level : A LPRM ID No.: 403 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 3/29/2002 1,270 0.261 1.082 0.000 No 1,155.3 7.1 No Yes 10/24/2002 3,799 1.663 1.060 0.000 No 1,089.9 7.0 No Yes 4/10/2003 8,044 2.746 1.097 0.000 No 993.5 6.9 No Yes 6/19/2003 9,728 3.353 1.057 0.000 No 939.9 6.8 No Yes 7/30/2003 10,792 3.751 1.062 0.000 No 885.1 6.8 No Yes 9/23/2004 41,990 9.806 1.084 0.000 No 602.6 6.4 No Yes 1/6/2005 44,679 10.499 1.056 0.000 No 570.7 6.3 No Yes 4/21/2005 47,373 11.242 1.068 0.000 No 534.4 6.3 No Yes 8/4/2005 50,051 11.965 1.068 0.000 No 500.3 6.2 No Yes 10/20/2005 52,015 12.568 1.078 0.000 No 464.0 6.1 No Yes 1/12/2006 54,140 13.234 1.069 0.000 No 434.1 6.1 No Yes 8/17/2006 58,629 14.409 1.062 0.000 No 340.6 5.8 No Yes 10/26/2006 60,414 14.848 1.049 0.000 No 324.7 5.8 No Yes

Level: B LPRM ID No. : 411 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.052 1.112 0.000 No 1,124.0 7.0 No Yes 8/15/2002 2,029 1.215 0.942 0.000 No 1,193.2 7.1 No Yes 12/5/2002 4,866 2.002 1.087 0.000 No 1,097.7 7.0 No Yes 2/26/2003 6,974 2.582 1.062 0.000 No 1,033.6 6.9 No Yes 5/15/2003 8,890 3.111 1.081 0.000 No 956.2 6.9 No Yes 7/30/2003 10,792 3.713 1.093 0.000 No 874.8 6.8 No Yes 10/16/2003 12,789 4.302 1.072 0.000 No 816.1 6.7 No Yes 12/30/2003 14,621 4.791 1.073 0.000 No 760.5 6.6 No Yes 2/19/2004 18,954 4.919 1.111 0.000 No 684.6 6.5 No Yes 3/25/2004 19,843 5.207 1.064 0.000 No 643.4 6.5 No Yes 7/15/2004 22,700 6.069 1.074 0.000 No 599.0 6.4 No Yes 10/28/2004 25,391 6.844 1.055 0.000 No 567.8 6.3 No Yes 1/6/2005 27,179 7.344 1.051 0.000 No 540.3 6.3 No Yes 4/21/2005 29,873 8.078 1.070 0.000 No 504.9 6.2 No Yes 8/4/2005 32,551 8.812 1.051 0.000 No 480.4 6.2 No Yes 10/20/2005 34,515 9.327 1.076 0.000 No 446.0 6.1 No Yes 3/24/2006 37,427 10.161 1.161 0.000 No 384.2 6.0 No Yes 7/13/2006 40,233 11.000 1.060 0.000 No 362.4 5.9 No Yes 10/26/2006 42,914 11.817 1.045 0.000 No 346.8 5.8 No Yes Level: C LPRM ID No.: 419 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/16/2003 12,789 4.388 1.084 0.000 No 816.5 6.7 No Yes 11/20/2003 13,694 4.613 1.056 0.000 No 773.2 6.7 No Yes 3/25/2004 19,843 5.193 1.149 0.000 No 672.9 6.5 No Yes 7/15/2004 22,700 6.186 1.110 0.000 No 606.2 6.4 No Yes 12/9/2004 26,458 7.424 1.107 0.000 No 547.6 6.3 No Yes 2/3/2005 27,896 7.976 1.060 0.000 No 516.6 6.2 No Yes 4/21/2005 29,873 8.702 1.086 0.000 No 475.7 6.2 No Yes 9/15/2005 33,614 9.807 1.071 0.000 No 444.2 6.1 No Yes 3/24/2006 37,427 10.501 1.106 0.000 No 401.6 6.0 No Yes 5/4/2006 38,475 10.809 1.065 0.000 No 377.1 5.9 No Yes 7/13/2006 40,233 11.336 1.070 0.000 No 352.4 5.9 No Yes 10/26/2006 42,914 12.140 1.061 0.000 No 332.2 5.8 No Yes

Level: D LPRM ID No.: 427 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.015 1.057 0.000 No 1,183.0 7.1 No Yes 6/6/2002 223 0.197 1.068 0.000 No 1,107.7 7.0 No Yes 9/19/2002 2,899 0.422 0.924 0.000 No 1,198.8 7.1 No Yes 2/26/2003 6,974 0.947 0.925 0.000 No 1,296.0 7.2 No Yes 7/30/2003 10,792 1.354 0.994 0.000 No 1,296.0 7.2 No Yes 12/30/2003 14,621 2.071 1.082 0.000 No 1,197.8 7.1 No Yes 2/19/2004 18,954 2.178 1.183 0.000 No 1,012.5 6.9 No Yes 3/25/2004 19,843 2.279 0.860 0.000 No 1,177.3 7.1 No Yes 5/6/2004 20,923 2.411 1.072 0.000 No 1,098.2 7.0 No Yes 8/12/2004 23,420 2.759 1.077 0.000 No 1,019.7 6.9 No Yes 1/6/2005 27,179 3.334 1.066 0.000 No 956.6 6.9 No Yes 6/30/2005 31,660 4.083 1.052 0.000 No 909.3 6.8 No Yes 9/15/2005 33,614 4.494 1.052 0.000 No 864.4 6.8 No Yes 12/1/2005 35,567 4.982 1.089 0.000 No 793.7 6.7 No Yes 1/12/2006 36,640 5.284 1.045 0.000 No 734.0 6.6 No Yes 9/21/2006 42,020 6.354 1.082 0.000 No 678.4 6.5 No Yes 10/26/2006 42,914 6.536 1.019 0.000 No 665.7 6.5 No Yes 2/14/2002 187 0.038 1.056 0.000 No 1,184.0 7.1 No Yes 8/15/2002 2,029 0.914 0.947 0.000 No 1,250.3 7.1 No Yes 1/16/2003 5,920 1.937 1.057 0.000 No 1,182.8 7.1 No Yes 4/10/2003 8,044 2.365 1.075 0.000 No 1,100.3 7.0 No Yes 7/30/2003 10,792 3.017 1.123 0.000 No 979.8 6.9 No Yes 10/16/2003 12,789 3.599 1.091 0.000 No 898.1 6.8 No Yes 12/30/2003 14,621 4.163 1.084 0.000 No 828.5 6.7 No Yes 2/19/2004 18,954 4.313 1.151 0.000 No 719.8 6.6 No Yes 7/15/2004 22,700 5.181 1.070 0.000 No 672.7 6.5 No Yes 12/9/2004 26,458 6.043 1.074 0.000 No 626.4 6.4 No Yes 4/21/2005 29,873 6.854 1.053 0.000 No 594.8 6.4 No Yes 8/4/2005 32,551 7.510 1.066 0.000 No 558.0 6.3 No Yes 10/20/2005 34,515 8.058 1.061 0.000 No 526.0 6.3 No Yes 1/12/2006 36,640 8.665 1.041 0.000 No 491.0 6.2 No Yes 3/24/2006 37,427 9.010 1.089 0.000 No 450.9 6.1 No Yes 7/13/2006 40,233 9.651 1.056 0.000 No 427.0 6.1 No Yes 10/26/2006 42,914 10.310 1.044 0.000 No 409.0 6.0 No Yes

String No. :

Coordinates:

Level:

Total 23 33 A

Serial No.: 03s61364 Type : NA300 LPRM ID No.: 502 Pre-Cal Cumulative Core Beginning Post-Cal Cycle Installed:

Average Exposure at BOC:

of Life Calibration Current:

Gaf's Exp.

18,500 1,250.0 11 Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.036 1.082 0.000 No 1,155.3 7.1 No Yes 3/25/2004 1,043 0.285 1.055 0.000 No 1,095.0 7.0 No Yes 6/17/2004 3,200 0.887 0.948 0.000 No 1,155.1 7.1 No Yes 4/21/2005 11,073 3.483 1.059 0.000 No 1,090.8 7.0 No Yes 3/24/2006 18,627 5.735 1.323 0.000 No 824.5 6.7 No Yes 6/8/2006 20,539 6.339 0.944 0.000 No 873.4 6.8 No Yes 10/26/2006 24,114 7.017 1.004 0.000 No 869.9 6.8 No Yes Level : B LPRM ID No. : 512 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/6/2004 2,123 0.584 0.932 0.000 No 1,341.2 7.2 No Yes 9/23/2004 5,690 1.528 0.919 0.000 No 1,459.4 7.3 No Yes 1/12/2006 17,840 4.949 1.056 0.000 No 1,382.0 7.2 No Yes 3/24/2006 18,627 5.265 1.240 0.000 No 1,114.5 7.0 No Yes 10/26/2006 24,114 6.679 1.058 0.000 No 1,053.4 7.0 No Yes Level: C LPRM ID No. : 522 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/6/2004 2,123 0.445 0.948 0.000 No 1,318.6 7.2 No Yes 9/23/2004 5,690 1.213 0.933 0.000 No 1,413.3 7.3 No Yes 1/12/2006 17,840 4.441 1.060 0.000 No 1,333.3 7.2 No Yes 3/24/2006 18,627 4.789 1.219 0.000 No 1,093.7 7.0 No Yes 10/26/2006 24,114 5.870 1.010 0.000 No 1,082.9 7.0 No Yes Level: D LPRM ID No.: 532 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.020 0.893 0.000 No 1,399.8 7.2 No Yes

10/28/2004 6,591 0.831 0.932 0.000 No 1,501.9 7.3 No Yes 3/24/2006 18,627 3.443 1.101 0.000 No 1,364.1 7.2 No Yes 10/26/2006 24,114 4.171 0.975 0.000 No 1,399.1 7.2 No Yes 6

Good Value Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Level : B LPRM ID No. : 153 Beginning of Life Calibration Current:

1,246.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good String No. : 24 Serial No.: L-2708 Cycle Installed:

Coordinates:

Level:

33 A

Type :

LPRM ID No.:

NA300 67 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

86,992 1,336.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

9/12/1996 21,038 3.452 1.079 0.000 Yes 720.0 6.6 No 8/25/1998 22,612 3.564 1.013 0.000 No 710.8 6.6 No 9/29/1998 23,473 3.713 1.018 0.000 No 698.2 6.5 No 2/4/1999 26,406 4.170 1.061 0.000 No 658.1 6.5 No 6/24/1999 29,696 4.674 1.067 0.000 No 616.7 6.4 No 11/24/1999 32,205 5.011 1.095 0.000 No 563.2 6.3 No 11/30/1999 32,341 5.038 1.068 0.000 No 527.4 6.3 No 3/8/2000 34,776 5.504 1.051 0.000 No 501.8 6.2 No 8/24/2000 39,057 6.427 1.058 0.000 No 474.3 6.2 No 4/26/2001 45,228 7.817 1.090 0.000 No 435.1 6.1 No 3/29/2002 50,962 9.378 1.079 0.000 No 383.0 5.9 No 12/20/2001 51,375 9.020 1.053 0.000 No 413.2 6.0 No 10/24/2002 53,491 10.474 1.077 0.000 No 355.6 5.9 No 7/30/2003 60,484 12.167 1.034 0.000 No 356.0 5.9 No 9/11/2003 61,579 12.485 1.080 0.000 No 329.6 5.8 No 12/30/2003 64,313 13.181 1.058 0.000 No 311.6 5.7 No 2/19/2004 68,646 13.277 1.085 0.000 No 287.2 5.7 No 3/25/2004 69,535 13.473 0.924 0.000 No 310.8 5.7 No 5/6/2004 70,615 13.706 1.095 0.000 No 283.8 5.6 No 12/9/2004 76,150 14.910 1.060 0.000 No 267.7 5.6 No 6/30/2005 81,352 16.077 0.946 0.000 No 283.0 5.6 No 8/4/2005 82,243 16.217 1.065 0.000 No 265.8 5.6 No 9/15/2005 83,306 16.393 1.061 0.000 No 250.5 5.5 No 12/1/2005 85,259 16.772 0.943 0.000 No 265.6 5.6 No 3/24/2006 87,119 17.096 1.190 0.000 No 223.2 5.4 No 10/26/2006 92,606 18.110 0.968 0.000 No 230.6 5.4 No

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 4.603 1.042 0.000 Yes 614.0 6.4 No Yes 8/25/1998 22,612 4.707 1.002 0.000 No 612.8 6.4 No Yes 9/29/1998 23,473 4.909 1.017 0.000 No 602.5 6.4 No Yes 2/4/1999 26,406 5.568 1.082 0.000 No 556.9 6.3 No Yes 6/24/1999 29,696 6.203 1.055 0.000 No 527.8 6.3 No Yes 11/24/1999 32,205 6.661 1.146 0.000 No 460.6 6.1 No Yes 12/27/1999 33,008 6.839 1.054 0.000 No 437.0 6.1 No Yes 6/14/2000 37,221 7.809 1.053 0.000 No 415.0 6.0 No Yes 12/7/2000 41,691 8.805 1.061 0.000 No 391.1 6.0 No Yes 8/17/2001 48,154 10.124 1.061 0.000 No 368.7 5.9 No Yes 10/18/2001 49,756 10.462 1.080 0.000 No 341.3 5.8 No Yes 3/29/2002 50,962 11.248 1.061 0.000 No 321.7 5.8 No Yes 8/15/2002 51,721 12.024 1.064 0.000 No 302.4 5.7 No Yes 2/26/2003 56,666 13.208 1.054 0.000 No 286.9 5.7 No Yes 7/30/2003 60,484 14.102 1.025 0.000 No 287.0 5.7 No Yes 9/11/2003 61,579 14.373 1.068 0.000 No 268.7 5.6 No Yes 12/30/2003 64,313 15.041 1.061 0.000 No 253.3 5.5 No Yes 2/19/2004 68,646 15.156 1.105 0.000 No 229.2 5.4 No Yes 10/28/2004 75,083 16.546 1.070 0.000 No 214.2 5.4 No Yes 6/30/2005 81,352 17.817 1.053 0.000 No 203.4 5.3 No Yes 1/12/2006 86,332 18.811 1.087 0.000 No 187.2 5.2 No Yes 3/24/2006 87,119 19.042 1.087 0.000 No 172.2 5.1 No Yes 8/17/2006 90,821 19.854 1.053 0.000 No 163.5 5.1 No Yes 10/26/2006 92,606 20.202 1.005 0.000 No 162.7 5.1 No Yes Level: C LPRM ID No. : 239 Beginning of Life Calibration Current:

1,263.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 4.640 1.063 0.000 Yes 653.0 6.5 No Yes 8/25/1998 22,612 4.718 0.985 0.000 No 662.9 6.5 No Yes 9/29/1998 23,473 4.879 1.026 0.000 No 646.1 6.5 No Yes 2/4/1999 26,406 5.474 1.064 0.000 No 607.3 6.4 No Yes 4/15/1999 28,093 5.844 1.056 0.000 No 575.1 6.4 No Yes 8/4/1999 30,557 6.358 1.068 0.000 No 538.5 6.3 No Yes 11/24/1999 32,205 6.719 1.103 0.000 No 488.2 6.2 No Yes 12/27/1999 33,008 6.854 1.050 0.000 No 464.9 6.1 No Yes 8/24/2000 39,057 7.873 1.055 0.000 No 440.7 6.1 No Yes

Level: D LPRM ID No.: 325 Beginning of Life Calibration Current :

1,391.0 Total Pre-Cal Post-Cal Gaf s Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 21,038 3.412 1.061 0.000 Yes 891.0 6.8 No Yes 8/25/1998 22,612 3.436 0.956 0.000 No 932.0 6.8 No Yes 9/29/1998 23,473 3.537 1.034 0.000 No 901.4 6.8 No Yes 3/11/1999 27,265 4.046 1.046 0.000 No 858.0 6.8 No Yes 4/15/1999 28,093 4.166 1.053 0.000 No 814.8 6.7 No Yes 9/17/1999 31,504 4.705 1.055 0.000 No 772.3 6.6 No Yes 11/24/1999 32,205 4.848 1.140 0.000 No 677.5 6.5 No Yes 6/14/2000 37,221 5.328 1.057 0.000 No 641.0 6.5 No Yes 3/22/2001 44,323 6.168 1.066 0.000 No 601.3 6.4 No Yes 2/14/2002 49,879 7.428 1.072 0.000 No 525.7 6.3 No Yes 12/20/2001 51,375 7.327 1.067 0.000 No 563.5 6.3 No Yes 4/10/2003 57,736 8.012 0.945 0.000 No 556.3 6.3 No Yes 7/30/2003 60,484 8.225 1.004 0.000 No 556.0 6.3 No Yes 2/19/2004 68,646 8.716 1.076 0.000 No 516.7 6.2 No Yes 3/25/2004 69,535 8.789 1.105 0.000 No 467.6 6.1 No Yes 5/6/2004 70,615 8.882 0.887 0.000 No 527.2 6.3 No Yes 8/12/2004 73,112 9.142 1.140 0.000 No 462.5 6.1 No Yes 9/23/2004 74,182 9.266 0.943 0.000 No 490.4 6.2 No Yes 10/28/2004 75,083 9.370 1.053 0.000 No 465.7 6.1 No Yes 12/9/2004 76,150 9.503 0.928 0.000 No 501.9 6.2 No Yes 1/6/2005 76,871 9.615 1.051 0.000 No 477.5 6.2 No Yes 1/18/2001 42,777 8.580 1.053 0.000 No 418.5 6.0 No Yes 6/6/2002 49,915 10.961 0.977 0.000 No 350.0 5.9 No Yes 11/15/2001 50,480 10.266 1.110 0.000 No 377.0 5.9 No Yes 7/30/2003 60,484 12.582 1.046 0.000 No 350.0 5.9 No Yes 10/16/2003 62,481 12.998 1.094 0.000 No 319.9 5.8 No Yes 2/19/2004 68,646 13.551 1.105 0.000 No 289.5 5.7 No Yes 8/12/2004 73,112 14.334 1.060 0.000 No 273.1 5.6 No Yes 1/6/2005 76,871 15.045 1.051 0.000 No 259.9 5.6 No Yes 8/4/2005 82,243 16.015 1.053 0.000 No 246.8 5.5 No Yes 1/12/2006 86,332 16.931 1.072 0.000 No 230.2 5.4 No Yes 3/24/2006 87,119 17.185 1.086 0.000 No 212.0 5.4 No Yes 8/17/2006 90,821 17.853 1.058 0.000 No 200.4 5.3 No Yes 10/26/2006 92,606 18.152 1.009 0.000 No 198.6 5.3 No Yes

String No.: 25 Serial No.: OOs19544 Cycle Installed:

10 Coordinates:

Level:

25 A

Type :

LPRM ID No.:

NA300 404 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

37,300 700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.060 1.103 0.000 No 1,133.0 7.0 No Yes 6/6/2002 223 0.842 0.983 0.000 No 1,078.0 7.0 No Yes 1/16/2003 5,920 2.432 1.077 0.000 No 1,000.9 6.9 No Yes 4/10/2003 8,044 3.232 1.082 0.000 No 925.1 6.8 No Yes 5/15/2003 8,890 3.587 1.053 0.000 No 878.5 6.8 No Yes 6/19/2003 9,728 3.863 1.067 0.000 No 823.3 6.7 No Yes 7/30/2003 10,792 4.173 1.050 0.000 No 823.0 6.7 No Yes 9/11/2003 11,887 4.483 1.085 0.000 No 758.5 6.6 No Yes 11/20/2003 13,694 5.021 1.067 0.000 No 710.9 6.6 No Yes 3/25/2004 19,843 5.536 1.098 0.000 No 647.4 6.5 No Yes 9/23/2004 24,490 6.618 1.128 0.000 No 574.0 6.4 No Yes 1/6/2005 27,179 7.371 0.945 0.000 No 607.4 6.4 No Yes 3/17/2005 28,969 7.895 1.139 0.000 No 533.3 6.3 No Yes 5/31/2005 30,892 8.564 1.052 0.000 No 506.9 6.2 No Yes 10/20/2005 34,515 9.659 1.062 0.000 No 477.0 6.2 No Yes 3/24/2006 37,427 10.400 1.117 0.000 No 427.0 6.1 No Yes 9/21/2006 42,020 11.598 1.077 0.000 No 396.5 6.0 No Yes 10/26/2006 42,914 11.883 1.029 0.000 No 385.3 6.0 No Yes Level: B LPRM ID No.: 412 Beginning of Life Calibration Current :

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.056 1.113 0.000 No 1,123.0 7.0 No Yes 10/24/2002 3,799 1.904 1.053 0.000 No 1,066.5 7.0 No Yes 6/30/2005 81,352 10.260 1.105 0.000 No 432.1 6.1 No Yes 8/4/2005 82,243 10.375 0.939 0.000 No 460.2 6.1 No Yes 10/20/2005 84,207 10.713 1.080 0.000 No 426.0 6.1 No Yes 3/24/2006 87,119 11.367 1.073 0.000 No 397.0 6.0 No Yes 6/8/2006 89,031 11.627 1.080 0.000 No 367.6 5.9 No Yes 7/13/2006 89,925 11.748 0.940 0.000 No 391.1 6.0 No Yes 9/21/2006 91,712 11.999 1.077 0.000 No 363.1 5.9 No Yes 10/26/2006 92,606 12.126 0.990 0.000 No 366.8 5.9 No Yes

Level: C LPRM ID No.: 420 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.033 1.089 0.000 No 1,148.0 7.0 No Yes 8/15/2002 2,029 0.862 0.942 0.000 No 1,218.7 7.1 No Yes 7130/2003 10,792 2.785 1.045 0.000 No 1,219.0 7.1 No Yes 9/11/2003 11,887 3.091 1.106 0.000 No 1,102.2 7.0 No Yes 11/20/2003 13,694 3.607 1.086 0.000 No 1,014.9 6.9 No Yes 2/19/2004 18,954 4.040 1.145 0.000 No 886.4 6.8 No Yes 7/15/2004 22,700 4.775 1.068 0.000 No 829.9 6.7 No Yes 12/912004 26,458 5.541 1.065 0.000 No 779.3 6.7 No Yes 4/21/2005 29,873 6.302 1.081 0.000 No 720.9 6.6 No Yes 9/15/2005 33,614 7.164 1.094 0.000 No 659.0 6.5 No Yes 10/20/2005 34,515 7.416 1.060 0.000 No 622.0 6.4 No Yes 1/12/2006 36,640 8.034 1.020 0.000 No 587.0 6.4 No Yes 3/24/2006 37,427 8.345 1.097 0.000 No 535.1 6.3 No Yes 6/8/2006 39,339 8.734 1.063 0.000 No 503.4 6.2 No Yes 10/26/2006 42,914 9.475 1.049 0.000 No 479.9 6.2 No Yes Level: D LPRM ID No.. 428 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.011 1.065 0.000 No 1,174.0 7.1 No Yes 1/16/2003 5,920 0.642 0.942 0.000 No 1,246.3 7.1 No Yes 1/16/2003 5,920 2.493 1.094 0.000 No 974.8 6.9 No Yes 4/10/2003 8,044 3.142 1.088 0.000 No 896.0 6.8 No Yes 6/19/2003 9,728 3.634 1.097 0.000 No 816.8 6.7 No Yes 7/30/2003 10,792 3.918 1.040 0.000 No 817.0 6.7 No Yes 9/11/2003 11,887 4.214 1.084 0.000 No 753.7 6.6 No Yes 11/20/2003 13,694 4.745 1.080 0.000 No 697.9 6.5 No Yes 2/19/2004 18,954 5.131 1.165 0.000 No 599.0 6.4 No Yes 8/12/2004 23,420 6.187 1.058 0.000 No 566.2 6.3 No Yes 3/17/2005 28,969 7.521 1.054 0.000 No 537.2 6.3 No Yes 8/4/2005 32,551 8.387 1.060 0.000 No 506.8 6.2 No Yes 10/20/2005 34,515 8.888 1.066 0.000 No 475.0 6.2 No Yes 3/24/2006 37,427 9.735 1.100 0.000 No 431.8 6.1 No Yes 7/13/2006 40,233 10.453 1.059 0.000 No 407.8 6.0 No Yes 10/26/2006 42,914 11.136 1.063 0.000 No 383.6 5.9 No Yes

7/30/2003 10,792 1.112 0.962 0.000 No 1,246.0 7.1 No Yes 2/19/2004 18,954 1.795 1.076 0.000 No 1,158.0 7.1 No Yes 3/25/2004 19,843 1.878 0.894 0.000 No 1,295.3 7.2 No Yes 5/6/2004 20,923 1.985 1.118 0.000 No 1,158.6 7.1 No Yes 7/15/2004 22,700 2.186 1.062 0.000 No 1,090.9 7.0 No Yes 9/23/2004 24,490 2.421 0.903 0.000 No 1,208.1 7.1 No Yes 10/28/2004 25,391 2.533 1.102 0.000 No 1,096.3 7.0 No Yes 1 /6/2005 27,179 2.801 1.081 0.000 No 1,014.2 6.9 No Yes 6/30/2005 31,660 3.521 1.069 0.000 No 948.7 6.9 No Yes 10/20/2005 34,515 4.066 1.069 0.000 No 887.5 6.8 No Yes 1211/2005 35,567 4.301 1.057 0.000 No 839.6 6.7 No Yes 1/12/2006 36,640 4.554 0.940 0.000 No 813.0 6.7 No Yes 6/8/2006 39,339 5.089 1.119 0.000 No 726.5 6.6 No Yes 10/26/2006 42,914 5.762 1.018 0.000 No 713.7 6.6 No Yes String No.: 26 Serial No.: 05x105132 Cycle Installed:

12 Coordinates: 25 Type : NA300 Cumulative Core Average Exposure at BOC:

0 Level: A LPRM ID No. : 580 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.040 1.097 0.000 No 1,139.5 7.0 No Yes 5/4/2006 1,175 0.348 1.077 0.000 No 1,058.0 7.0 No Yes 8/17/2006 3,829 1.165 1.053 0.000 No 1,004.8 6.9 No Yes 9/21/2006 4,720 1.445 0.945 0.000 No 1,063.2 7.0 No Yes 10/26/2006 5,614 1.736 1.026 0.000 No 1,036.3 6.9 No Yes Level: B LPRM ID No.: 588 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/26/2006 5,614 1.704 0.988 0.000 No 1,265.2 7.1 No Yes Level: C LPRM ID No.: 596 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 6/8/2006 2,039 0.457 1.053 0.000 No 1,187.1 7.1 No Yes 9/21/2006 4,720 1.161 0.942 0.000 No 1,260.2 7.1 No Yes

10/26/2006 5,614 1.387 0.994 0.000 No 1,267.8 7.1 No Yes Level: D LPRM ID No.: 604 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.015 0.920 0.000 No 1,358.7 7.2 No Yes 10/26/2006 5,614 1.068 0.997 0.000 No 1,362.8 7.2 No Yes String No. : 27 Serial No. : 03s61359 Cycle Installed:

11 Coordinates: 25 Type : NA300 Cumulative Core Average Exposure at BOC:

18,500 Level : A LPRM ID No.: 503 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.033 1.059 0.000 No 1,180.4 7.1 No Yes 12/9/2004 7,658 2.369 0.915 0.000 No 1,290.0 7.2 No Yes 4/21/2005 11,073 3.674 1.073 0.000 No 1,202.2 7.1 No Yes 1/12/2006 17,840 5.446 0.929 0.000 No 1,223.0 7.1 No Yes 3/24/2006 18,627 5.622 1.141 0.000 No 1,071.9 7.0 No Yes 10/26/2006 24,114 7.185 1.057 0.000 No 1,014.1 6.9 No Yes Level: B LPRM ID No.: 513 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.042 1.076 0.000 No 1,161.7 7.1 No Yes 5/6/2004 2,123 0.615 0.943 0.000 No 1,231.9 7.1 No Yes 12/9/2004 7,658 2.191 0.949 0.000 No 1,298.1 7.2 No Yes 1/12/2006 17,840 5.061 1.039 0.000 No 1,195.0 7.1 No Yes 3/24/2006 18,627 5.336 1.074 0.000 No 1,112.7 7.0 No Yes 10/26/2006 24,114 6.948 1.018 0.000 No 1,093.0 7.0 No Yes Level: C LPRM ID No. : 523 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/25/2004 1,043 0.238 1.061 0.000 No 1,178.1 7.1 No Yes 6/17/2004 3,200 0.717 0.928 0.000 No 1,269.5 7.1 No Yes 10/28/2004 6,591 1.518 0.948 0.000 No 1,339.2 7.2 No Yes

String No.: 28 Serial No.: 00s19546 Cycle Installed:

10 Coordinates:

Level :

25 A

Type:

LPRM ID No. :

NA300 405 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

37,300 700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.054 1.087 0.000 No 1,150.0 7.0 No Yes 8/15/2002 2,029 1.373 1.079 0.000 No 1,065.8 7.0 No Yes 12/5/2002 4,866 2.050 1.063 0.000 No 1,002.6 6.9 No Yes 4/10/2003 8,044 2.905 1.110 0.000 No 903.3 6.8 No Yes 6/19/2003 9,728 3.507 1.095 0.000 No 824.9 6.7 No Yes 7/30/2003 10,792 3.899 1.061 0.000 No 777.5 6.7 No Yes 10/16/2003 12,789 4.471 1.071 0.000 No 725.9 6.6 No Yes 2/19/2004 18,954 4.945 1.116 0.000 No 650.5 6.5 No Yes 5/6/2004 20,923 5.598 1.078 0.000 No 603.4 6.4 No Yes 8/12/2004 23,420 6.376 1.059 0.000 No 569.8 6.3 No Yes 12/9/2004 26,458 7.277 1.081 0.000 No 527.1 6.3 No Yes 5/31/2005 30,892 9.074 1.108 0.000 No 475.7 6.2 No Yes 10/20/2005 34,515 9.913 0.944 0.000 No 504.0 6.2 No Yes 3/17/2005 1/12/2006 3/24/2006 10/26/2006 10,169 17,840 18,627 24,114 2.403 4.603 4.921 6.232 0.946 1.034 1.127 1.026 0.000 0.000 0.000 0.000 No No No No 1,415.6 1,330.0 1,180.1 1,150.2 7.3 7.2 7.1 7.0 No No No No Yes Yes Yes Yes Level: D LPRM ID No.: 533 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/19/2004 154 0.023 0.925 0.000 No 1,351.4 7.2 No Yes 9/23/2004 5,690 0.763 1.057 0.000 No 1,278.5 7.2 No Yes 10/28/2004 6,591 0.896 0.916 0.000 No 1,395.7 7.2 No Yes 1/6/2005 8,379 1.194 1.057 0.000 No 1,320.5 7.2 No Yes 2/3/2005 9,096 1.324 0.948 0.000 No 1,392.9 7.2 No Yes 8/4/2005 13,751 2.186 0.930 0.000 No 1,497.7 7.3 No Yes 9/15/2005 14,814 2.467 1.055 0.000 No 1,419.6 7.3 No Yes 10/20/2005 15,715 2.687 0.946 0.000 No 1,501.0 7.3 No Yes 3/24/2006 18,627 3.623 1.148 0.000 No 1,302.0 7.2 No Yes 10/26/2006 24,114 4.732 0.965 0.000 No 1,349.2 7.2 No Yes

1/1212006 3/24/2006 7/13/2006 10/26/2006 36,640 37,427 40,233 42,914 10.281 10.470 11.239 11.985 1.043 1.117 1.099 0.996 0.000 0.000 0.000 0.000 No No No No 469.0 419.9 382.1 383.6 6.2 6.0 5.9 5.9 No No No No Yes Yes Yes Yes Level : B LPRM ID No. : 413 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2114/2002 187 0.052 1.149 0.000 No 1,088.0 7.0 No Yes 1/16/2003 5,920 2.379 1.056 0.000 No 1,030.3 6.9 No Yes 4/10/2003 8,044 2.955 1.107 0.000 No 930.7 6.8 No Yes 6/19/2003 9,728 3.438 1.088 0.000 No 855.4 6.8 No Yes 7/30/2003 10,792 3.765 1.048 0.000 No 855.0 6.8 No Yes 9/11/2003 11,887 4.083 1.079 0.000 No 792.4 6.7 No Yes 11/20/2003 13,694 4.562 1.058 0.000 No 749.0 6.6 No Yes 2/19/2004 18,954 4.926 1.199 0.000 No 624.7 6.4 No Yes 6/17/2004 22,000 5.875 1.059 0.000 No 589.9 6.4 No Yes 10/28/2004 25,391 6.795 1.055 0.000 No 559.1 6.3 No Yes 2/3/2005 27,896 7.497 1.069 0.000 No 523.0 6.3 No Yes 5/31/2005 30,892 8.390 1.052 0.000 No 497.2 6.2 No Yes 8/4/2005 32,551 8.846 1.068 0.000 No 465.5 6.1 No Yes 12/1/2005 35,567 9.638 1.055 0.000 No 441.2 6.1 No Yes 3/24/2006 37,427 10.215 1.098 0.000 No 401.9 6.0 No Yes 8/17/2006 41,129 11.257 1.057 0.000 No 380.2 5.9 No Yes 10/26/2006 42,914 11.795 1.026 0.000 No 370.6 5.9 No Yes Level: C LPRM ID No. : 421 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.038 1.083 0.000 No 1,154.0 7.1 No Yes 2/26/2003 6,974 2.132 1.063 0.000 No 1,085.6 7.0 No Yes 6/19/2003 9,728 2.691 1.110 0.000 No 978.0 6.9 No Yes 7/30/2003 10,792 2.971 1.059 0.000 No 923.5 6.8 No Yes 10/16/2003 12,789 3.546 1.072 0.000 No 861.5 6.8 No Yes 12/30/2003 14,621 4.111 1.086 0.000 No 793.3 6.7 No Yes 2/19/2004 18,954 4.266 1.134 0.000 No 699.5 6.6 No Yes 7/15/2004 22,700 5.152 1.067 0.000 No 655.6 6.5 No Yes 12/9/2004 26,458 5.991 1.062 0.000 No 617.3 6.4 No Yes 4/21/2005 29,873 6.891 1.068 0.000 No 578.0 6.4 No Yes

Level: D LPRM ID No.: 429 Beginning of Life Calibration Current :

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.016 1.033 0.000 No 1,250.0 7.1 No Yes 3/29/2002 1,270 0.114 1.052 0.000 No 1,188.2 7.1 No Yes 9/19/2002 2,899 0.483 0.937 0.000 No 1,268.1 7.1 No Yes 2/26/2003 6,974 1.021 0.945 0.000 No 1,341.9 7.2 No Yes 7/30/2003 10,792 1.422 0.993 0.000 No 1,342.0 7.2 No Yes 2/19/2004 18,954 2.276 1.083 0.000 No 1,239.2 7.1 No Yes 3/25/2004 19,843 2.380 1.084 0.000 No 1,143.1 7.0 No Yes 5/6/2004 20,923 2.517 0.916 0.000 No 1,248.0 7.1 No Yes 6/17/2004 22,000 2.665 1.062 0.000 No 1,175.1 7.1 No Yes 9/23/2004 24,490 3.007 1.094 0.000 No 1,074.1 7.0 No Yes 10/28/2004 25,391 3.134 0.948 0.000 No 1,133.1 7.0 No Yes 1/6/2005 27,179 3.442 1.077 0.000 No 1,052.0 7.0 No Yes 2/3/2005 27,896 3.588 1.067 0.000 No 986.0 6.9 No Yes 8/4/2005 32,551 4.448 1.067 0.000 No 924.1 6.8 No Yes 9/15/2005 33,614 4.695 1.082 0.000 No 854.0 6.7 No Yes 12/1/2005 35,567 5.191 1.055 0.000 No 809.5 6.7 No Yes 1/12/2006 36,640 5.514 1.036 0.000 No 757.0 6.6 No Yes 8/17/2006 41,129 6.490 1.060 0.000 No 714.2 6.6 No Yes 9/21/2006 42,020 6.695 1.071 0.000 No 666.8 6.5 No Yes 10/26/2006 42,914 6.911 1.028 0.000 No 648.6 6.5 No Yes String No.: 29 Serial No.: 05005134 Cycle Installed:

12 Coordinates: 25 Type : NA300 Cumulative Core Average Exposure at BOC:

0 Level: A LPRM ID No. : 581 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.046 1.207 0.000 No 1,035.6 6.9 No Yes 8/4/2005 32,551 7.590 1.100 0.000 No 525.5 6.3 No Yes 12/1/2005 35,567 8.472 1.053 0.000 No 499.0 6.2 No Yes 1/12/2006 36,640 8.805 1.023 0.000 No 471.0 6.2 No Yes 3/24/2006 37,427 9.139 1.059 0.000 No 444.8 6.1 No Yes 6/8/2006 39,339 9.557 1.053 0.000 No 422.4 6.0 No Yes 10/26/2006 42,914 10.412 1.041 0.000 No 405.7 6.0 No Yes

8/17/2006 3,829 1.223 1.270 0.000 No 993.0 6.9 No Yes 10/26/2006 5,614 1.706 1.025 0.000 No 968.8 6.9 No Yes Level: B LPRM ID No.: 589 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.041 1.165 0.000 No 1,073.0 7.0 No Yes 5/4/2006 1,175 0.377 1.061 0.000 No 1,011.3 6.9 No Yes 8/17/2006 3,829 1.193 0.915 0.000 No 1,105.2 7.0 No Yes 10/26/2006 5,614 1.713 1.001 0.000 No 1,104.1 7.0 No Yes Level: C LPRM ID No.: 597 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.029 1.032 0.000 No 1,250.0 7.1 No Yes 5/4/2006 1,175 0.273 1.078 0.000 No 1,159.6 7.1 No Yes 10/26/2006 5,614 1.354 0.963 0.000 No 1,204.1 7.1 No Yes Level: D LPRM ID No.: 605 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/26/2006 5,614 1.023 0.993 0.000 No 1,258.8 7.1 No Yes String No.: 30 Serial No. : 05s105125 Cycle Installed:

12 Coordinates: 25 Type : NA300 Cumulative Core Average Exposure at BOC:

0 Level: A LPRM ID No. : 582 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.040 1.176 0.000 No 1,062.9 7.0 No Yes 8/17/2006 3,829 1.149 1.263 0.000 No 989.7 6.9 No Yes 10/26/2006 5,614 1.687 1.044 0.000 No 948.0 6.9 No Yes Level: B LPRM ID No. : 590 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.036 1.125 0.000 No 1,111.1 7.0 No Yes

Date 2/16/2006 5/4/2006 10/26/2006 CAVEX 0

1,175 5,614 Exp GAF 0.000 1.000 0.165 1.068 0.853 0.935 GAFpost Corrected CalCur 0.000 No 1,250.0 0.000 No 1,170.4 0.000 No 1,251.8 7.1 7.1 7.1 Byp.?

No No No Value Yes Yes Yes String No. : 31 Serial No. : 95SO1703 Cycle Installed:

8 Coordinates: 25 Type : NA300 Cumulative Core Average Exposure at BOC:

67,204 Level: A LPRM ID No. : 74 Beginning of Life Calibration Current:

1,349.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.387 1.078 0.000 Yes 1,234.0 7.1 No Yes 8/25/1998 2,824 0.507 1.059 0.000 No 1,165.3 7.1 No Yes 9/29/1998 3,685 0.660 1.049 0.000 No 1,110.8 7.0 No Yes 11/30/1999 12,553 2.016 1.059 0.000 No 1,048.9 7.0 No Yes 9/28/2000 20,178 3.631 1.084 0.000 No 967.7 6.9 No Yes 4/26/2001 25,440 4.911 1.068 0.000 No 906.0 6.8 No Yes 2/14/2002 30,091 6.336 1.091 0.000 No 753.6 6.6 No Yes 6/6/2002 30,127 6.866 1.023 0.000 No 709.0 6.6 No Yes 11/15/2001 30,692 6.038 1.102 0.000 No 822.2 6.7 No Yes 9/19/2002 32,803 7.491 1.093 0.000 No 648.7 6.5 No Yes 1/16/2003 35,824 8.116 1.075 0.000 No 603.4 6.4 No Yes 4/10/2003 37,948 8.723 1.073 0.000 No 562.4 6.3 No Yes 6/19/2003 39,632 9.280 1.051 0.000 No 535.1 6.3 No Yes 7/30/2003 40,696 9.608 1.015 0.000 No 535.0 6.3 No Yes 10/16/2003 42,693 10.055 1.080 0.000 No 495.4 6.2 No Yes 10/26/2006 5,614 1.628 1.023 0.000 No 1,086.1 7.0 No Yes Level : C LPRM ID No.: 598 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.026 1.061 0.000 No 1,178.1 7.1 No Yes 5/4/2006 1,175 0.242 1.059 0.000 No 1,112.5 7.0 No Yes 7/13/2006 2,933 0.634 0.947 0.000 No 1,174.8 7.1 No Yes 9/21/2006 4,720 1.038 0.905 0.000 No 1,298.1 7.2 No Yes 10/26/2006 5,614 1.234 0.964 0.000 No 1,346.6 7.2 No Yes Level: D LPRM ID No.: 606 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good

Yes Yes Yes Yes Yes Yes Yes Yes Yes Good Value Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Level: C LPRM ID No. : 246 Beginning of Life Calibration Current:

1,368.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Level : B LPRM ID No.: 160 Beginning of Life Calibration Current:

1,571.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

9/12/1996 1,276 0.514 1.031 0.000 Yes 1,461.0 7.3 No 8/25/1998 2,824 0.630 1.097 0.000 No 1,331.8 7.2 No 9/29/1998 3,685 0.831 0.999 0.000 No 1,333.1 7.2 No 4/15/1999 8,305 1.849 1.049 0.000 No 1,270.9 7.1 No 8/4/1999 10,769 2.326 1.049 0.000 No 1,211.5 7.1 No 11/30/1999 12,553 2.627 1.094 0.000 No 1,107.4 7.0 No 11/4/2000 21,053 4.500 1.063 0.000 No 1,041.8 6.9 No 2/22/2001 23,810 5.114 1.101 0.000 No 946.2 6.9 No 6/7/2001 26,529 5.642 1.063 0.000 No 890.1 6.8 No 10/18/2001 29,968 6.392 1.069 0.000 No 832.7 6.7 No 2/14/2002 30,091 6.911 1.168 0.000 No 671.3 6.5 No 6/6/2002 30,127 7.505 0.995 0.000 No 625.0 6.4 No 12/20/2001 31,587 6.752 1.062 0.000 No 784.1 6.7 No 9/19/2002 32,803 8.154 1.076 0.000 No 580.9 6.4 No 1/16/2003 35,824 8.906 1.086 0.000 No 534.9 6.3 No 6/19/2003 39,632 9.868 1.068 0.000 No 500.8 6.2 No 7/30/2003 40,696 10.140 1.022 0.000 No 501.0 6.2 No 9/11/2003 41,791 10.400 1.055 0.000 No 474.9 6.2 No 11/20/2003 43,598 10.796 1.052 0.000 No 451.4 6.1 No 12/30/2003 44,525 11.017 1.019 0.000 No 443.0 6.1 No 3/24/2006 67,331 15.050 1.537 0.000 No 293.7 5.7 No 7/13/2006 70,137 15.690 1.055 0.000 No 278.4 5.6 No 10/26/2006 72,818 16.259 1.054 0.000 No 264.1 5.6 No 2119/2004 48,858 10.563 1.056 0.000 No 469.1 6.2 No 3/25/2004 49,747 10.730 1.062 0.000 No 441.7 6.1 No 7/15/2004 52,604 11.272 1.068 0.000 No 413.6 6.0 No 10/28/2004 55,295 11.902 1.055 0.000 No 392.0 6.0 No 1/12/2006 66,544 14.125 0.947 0.000 No 414.0 6.0 No 3/24/2006 67,331 14.274 1.147 0.000 No 360.9 5.9 No 5/4/2006 68,379 14.533 1.077 0.000 No 335.1 5.8 No 9/21/2006 71,924 15.263 1.079 0.000 No 310.6 5.7 No 10/26/2006 72,818 15.431 1.003 0.000 No 309.6 5.7 No

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.440 1.023 0.000 Yes 1,292.0 7.2 No Yes 8/25/1998 2,824 0.514 1.113 0.000 No 1,160.8 7.1 No Yes 9/29/1998 3,685 0.674 0.983 0.000 No 1,180.9 7.1 No Yes 11/24/1999 12,417 2.432 1.128 0.000 No 1,046.9 7.0 No Yes 3/8/2000 14,988 2.857 1.062 0.000 No 985.8 6.9 No Yes 2/22/2001 23,810 4.400 1.070 0.000 No 921.3 6.8 No Yes 6/7/2001 26,529 5.024 1.080 0.000 No 853.0 6.7 No Yes 9/13/2001 29,065 5.592 1.058 0.000 No 806.3 6.7 No Yes 2/14/2002 30,091 6.288 1.192 0.000 No 639.3 6.5 No Yes 11/15/2001 30,692 5.947 1.058 0.000 No 762.1 6.6 No Yes 9/19/2002 32,803 7.017 1.069 0.000 No 598.1 6.4 No Yes 4/10/2003 37,948 7.827 1.051 0.000 No 569.0 6.3 No Yes 7/30/2003 40,696 8.284 1.047 0.000 No 569.0 6.3 No Yes 9/11/2003 41,791 8.506 1.082 0.000 No 525.9 6.3 No Yes 11/20/2003 43,598 8.924 1.067 0.000 No 492.9 6.2 No Yes 2/19/2004 48,858 9.271 1.098 0.000 No 448.9 6.1 No Yes 10/28/2004 55,295 10.438 1.065 0.000 No 421.5 6.0 No Yes 12/9/2004 56,362 10.643 1.054 0.000 No 399.9 6.0 No Yes 5/31/2005 60,796 11.499 1.065 0.000 No 375.5 5.9 No Yes 10/20/2005 64,419 12.219 1.069 0.000 No 351.0 5.9 No Yes 3/24/2006 67,331 12.945 1.105 0.000 No 317.6 5.8 No Yes 7/13/2006 70,137 13.449 1.061 0.000 No 299.4 5.7 No Yes 10/26/2006 72,818 13.909 1.006 0.000 No 297.6 5.7 No Yes Level: D LPRM ID No. : 332 Beginning of Life Calibration Current:

1,382.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp ?

Value 9/12/1996 1,276 0.298 0.974 0.000 Yes 1,369.0 7.2 No Yes 8/25/1998 2,824 0.323 1.123 0.000 No 1,219.1 7.1 No Yes 9/29/1998 3,685 0.422 0.987 0.000 No 1,235.1 7.1 No Yes 11/30/1999 12,553 1.716 1.124 0.000 No 1,098.9 7.0 No Yes 2/14/2002 30,091 4.175 1.242 0.000 No 839.4 6.7 No Yes 11/15/2001 30,692 3.922 1.054 0.000 No 1,042.6 6.9 No Yes 12/5/2002 34,770 4.548 0.949 0.000 No 884.5 6.8 No Yes 1/16/2003 35,824 4.620 1.051 0.000 No 841.6 6.7 No Yes 7/30/2003 40,696 4.944 0.968 0.000 No 842.0 6.7 No Yes 12/30/2003 44,525 5.374 1.074 0.000 No 784.0 6.7 No Yes

6/17/2004 51,904 5.763 1.059 0.000 No 740.3 6.6 No Yes 12/9/2004 56,362 6.324 1.090 0.000 No 679.2 6.5 No Yes 4/21/2005 59,777 6.908 1.061 0.000 No 640.1 6.5 No Yes 8/4/2005 62,455 7.334 1.070 0.000 No 598.3 6.4 No Yes 12/1/2005 65,471 7.937 1.070 0.000 No 559.1 6.3 No Yes 3/24/2006 67,331 8.402 1.091 0.000 No 513.0 6.2 No Yes 8/17/2006 71,033 8.877 1.054 0.000 No 486.7 6.2 No Yes 9/21/2006 71,924 8.996 0.939 0.000 No 518.3 6.3 No Yes 10/26/2006 72,818 9.115 1.004 0.000 No 516.3 6.2 No Yes String No. : 32 Serial No. : 05s105130 Cycle Installed:

12 Coordinates: 17 Type : NA300 Cumulative Core Average Exposure at BOC:

0 Level : A LPRM ID No. : 583 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.035 1.087 0.000 No 1,150.0 7.0 No Yes 5/4/2006 1,175 0.305 1.088 0.000 No 1,056.9 7.0 No Yes 10/26/2006 5,614 1.341 1.003 0.000 No 1,053.8 7.0 No Yes Level: B LPRM ID No.: 591 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp ?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/4/2006 1,175 0.278 1.067 0.000 No 1,171.5 7.1 No Yes 10/26/2006 5,614 1.294 0.992 0.000 No 1,181.0 7.1 No Yes Level: C LPRM ID No.: 599 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.021 1.096 0.000 No 1,140.5 7.0 No Yes 10/26/2006 5,614 1.026 1.028 0.000 No 1,109.4 7.0 No Yes Level: D LPRM ID No.: 607 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/26/2006 5,614 0.756 0.951 0.000 No 1,314.4 7.2 No Yes

String No. : 33 Serial No. : 00s19545 Cycle Installed:

10 Coordinates:

Level:

17 A

Type :

LPRM ID No.:

NA300 406 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

37,300 700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.062 1.158 0.000 No 1,079.0 7.0 No Yes 8/15/2002 2,029 1.492 1.052 0.000 No 1,025.7 6.9 No Yes 10/24/2002 3,799 2.036 1.106 0.000 No 927.4 6.8 No Yes 1/16/2003 5,920 2.597 1.087 0.000 No 853.1 6.7 No Yes 4/10/2003 8,044 3.270 1.132 0.000 No 753.7 6.6 No Yes 6/19/2003 9,728 3.817 1.062 0.000 No 709.7 6.6 No Yes 7/30/2003 10,792 4.106 1.055 0.000 No 672.7 6.5 No Yes 12/30/2003 14,621 4.922 1.055 0.000 No 637.6 6.5 No Yes 2/19/2004 18,954 5.013 1.091 0.000 No 584.4 6.4 No Yes 5/6/2004 20,923 5.688 1.068 0.000 No 547.2 6.3 No Yes 9/23/2004 24,490 6.775 1.062 0.000 No 515.3 6.2 No Yes 2/3/2005 27,896 7.840 1.067 0.000 No 482.9 6.2 No Yes 3/17/2005 28,969 8.233 1.052 0.000 No 459.0 6.1 No Yes 1221/2005 35,567 10.250 1.078 0.000 No 425.8 6.1 No Yes 3/24/2006 37,427 10.685 1.181 0.000 No 360.6 5.9 No Yes 10/26/2006 42,914 12.204 1.064 0.000 No 338.9 5.8 No Yes Level: B LPRM ID No. : 414 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.058 1.209 0.000 No 1,034.0 6.9 No Yes 10/24/2002 3,799 1.990 1.084 0.000 No 953.9 6.9 No Yes 1/16/2003 5,920 2.591 1.071 0.000 No 890.6 6.8 No Yes 4/10/2003 8,044 3.181 1.098 0.000 No 811.1 6.7 No Yes 7/30/2003 10,792 3.922 1.081 0.000 No 750.4 6.6 No Yes 10/16/2003 12,789 4.418 1.078 0.000 No 696.1 6.5 No Yes 2/19/2004 18,954 5.037 1.209 0.000 No 575.7 6.4 No Yes 7/15/2004 22,700 6.179 1.074 0.000 No 536.1 6.3 No Yes 12/9/2004 26,458 7.178 1.061 0.000 No 505.3 6.2 No Yes 5/31/2005 30,892 8.321 1.088 0.000 No 464.4 6.1 No Yes 10/20/2005 34,515 9.331 1.080 0.000 No 430.0 6.1 No Yes 1/12/2006 36,640 9.883 1.018 0.000 No 407.0 6.0 No Yes 3/24/2006 37,427 10.189 1.086 0.000 No 374.8 5.9 No Yes

8/17/2006 10/26/2006 Level :

41,129 42,914 C

11.235 11.726 LPRM ID No. :

1.074 1.031 422 0.000 0.000 Beginning No No of Life Calibration 348.9 338.5 Current:

5.9 5.8 No No 700.0 Yes Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.037 1.122 0.000 No 1,114.0 7.0 No Yes 8/15/2002 2,029 0.944 0.937 0.000 No 1,188.9 7.1 No Yes 6/19/2003 9,728 2.685 1.058 0.000 No 1,123.7 7.0 No Yes 7/30/2003 10,792 2.924 1.038 0.000 No 1,124.0 7.0 No Yes 9/11/2003 11,887 3.191 1.070 0.000 No 1,050.5 7.0 No Yes 11/20/2003 13,694 3.689 1.071 0.000 No 980.8 6.9 No Yes 2/19/2004 18,954 4.140 1.134 0.000 No 864.9 6.8 No Yes 5/6/2004 20,923 4.606 1.064 0.000 No 812.9 6.7 No Yes 7/15/2004 22,700 5.016 1.071 0.000 No 759.0 6.6 No Yes 1/6/2005 27,179 6.015 1.089 0.000 No 697.0 6.5 No Yes 4/21/2005 29,873 6.618 1.054 0.000 No 661.3 6.5 No Yes 8/4/2005 32,551 7.275 1.061 0.000 No 623.3 6.4 No Yes 10/20/2005 34,515 7.847 1.088 0.000 No 573.0 6.4 No Yes 12/1/2005 35,567 8.132 1.053 0.000 No 544.2 6.3 No Yes 3/24/2006 37,427 8.794 1.088 0.000 No 500.1 6.2 No Yes 6/8/2006 39,339 9.230 1.091 0.000 No 458.4 6.1 No Yes 10/26/2006 42,914 10.104 1.018 0.000 No 450.3 6.1 No Yes Level: D LPRM ID No.: 430 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.013 1.023 0.000 No 1,250.0 7.1 No Yes 3/29/2002 1,270 0.093 1.064 0.000 No 1,174.8 7.1 No Yes 10/24/2002 3,799 0.516 0.946 0.000 No 1,241.9 7.1 No Yes 2/26/2003 6,974 0.868 0.944 0.000 No 1,315.5 7.2 No Yes 4/10/2003 8,044 0.981 1.057 0.000 No 1,244.6 7.1 No Yes 5/15/2003 8,890 1.076 0.929 0.000 No 1,339.7 7.2 No Yes 7/30/2003 10,792 1.310 0.983 0.000 No 1,340.0 7.2 No Yes 5/6/2004 20,923 2.320 1.072 0.000 No 1,238.0 7.1 No Yes 9/15/2005 33,614 4.411 1.339 0.000 No 922.0 6.8 No Yes 10/20/2005 34,515 4.634 1.080 0.000 No 854.0 6.7 No Yes 1/12/2006 36,640 5.146 1.014 0.000 No 797.0 6.7 No Yes 6/8/2006 39,339 5.724 1.056 0.000 No 754.7 6.6 No Yes

10/26/2006 42,914 6.408 1.056 0.000 No 714.7 6.6 No Yes String No. : 34 Serial No. : 03s61360 Cycle Installed:

11 Coordinates: 17 Type : NA300 Cumulative Core Average Exposure at BOC:

18,500 Level : A LPRM ID No.: 504 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/25/2004 1,043 0.334 1.135 0.000 No 1,101.3 7.0 No Yes 6/17/2004 3,200 1.089 1.059 0.000 No 1,040.0 6.9 No Yes 7/15/2004 3,900 1.332 0.939 0.000 No 1,107.5 7.0 No Yes 8/12/2004 4,620 1.577 1.071 0.000 No 1,034.1 6.9 No Yes 3/24/2006 18,627 5.709 1.192 0.000 No 867.5 6.8 No Yes 5/4/2006 19,675 6.013 0.906 0.000 No 957.5 6.9 No Yes 7/13/2006 21,433 6.546 1.135 0.000 No 843.7 6.7 No Yes 10/26/2006 24,114 7.373 1.007 0.000 No 837.8 6.7 No Yes Level: B LPRM ID No.: 514 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/6/2004 2,123 0.665 0.927 0.000 No 1,348.4 7.2 No Yes 8/12/2004 4,620 1.417 0.940 0.000 No 1,434.5 7.3 No Yes 12/9/2004 7,658 2.251 0.947 0.000 No 1,514.8 7.3 No Yes 1/12/2006 17,840 4.985 1.016 0.000 No 1,441.0 7.3 No Yes 3/24/2006 18,627 5.297 1.197 0.000 No 1,203.8 7.1 No Yes 10/26/2006 24,114 6.962 1.021 0.000 No 1,179.1 7.1 No Yes Level : C LPRM ID No.: 524 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 6/17/2004 3,200 0.760 0.918 0.000 No 1,361.7 7.2 No Yes 12/9/2004 7,658 1.811 0.935 0.000 No 1,456.3 7.3 No Yes 1/12/2006 17,840 4.490 1.038 0.000 No 1,339.0 7.2 No Yes 3/24/2006 18,627 4.838 1.114 0.000 No 1,202.0 7.1 No Yes 10/26/2006 24,114 6.199 1.038 0.000 No 1,158.0 7.1 No Yes Level: D LPRM ID No.: 534 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12130/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/6/2004 2,123 0.231 0.936 0.000 No 1,335.5 7.2 No Yes 7/15/2004 3,900 0.455 1.063 0.000 No 1,256.3 7.1 No Yes 8/12/2004 4,620 0.566 0.948 0.000 No 1,325.2 7.2 No Yes 10/28/2004 6,591 0.854 0.938 0.000 No 1,412.8 7.3 No Yes 12/9/2004 7,658 1.016 1.052 0.000 No 1,343.0 7.2 No Yes 2/3/2005 9,096 1.274 0.917 0.000 No 1,464.6 7.3 No Yes 1/12/2006 17,840 3.112 1.052 0.000 No 1,392.2 7.2 No Yes 5/4/2006 19,675 3.580 1.070 0.000 No 1,301.1 7.2 No Yes 10/26/2006 24,114 4.484 0.974 0.000 No 1,335.8 7.2 No Yes String No. : 35 Serial No.: 99SO6334 Cycle Installed:

9 Coordinates: 17 Type : NA300 Cumulative Core Average Exposure at BOC:

54,800 Level: A LPRM ID No.: 349 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/30/1999 149 0.024 1.063 0.000 No 1,175.9 7.1 No Yes 4/12/2000 3,445 0.655 0.949 0.000 No 1,239.1 7.1 No Yes 4/26/2001 13,036 2.862 1.073 0.000 No 1,155.0 7.1 No Yes 2/14/2002 17,687 4.486 1.072 0.000 No 1,014.5 6.9 No Yes 6/6/2002 17,723 5.332 0.976 0.000 No 941.0 6.8 No Yes 11/15/2001 18,288 4.105 1.062 0.000 No 1,087.6 7.0 No Yes 10/24/2002 21,299 6.266 1.064 0.000 No 884.4 6.8 No Yes 4/10/2003 25,544 7.519 1.101 0.000 No 803.3 6.7 No Yes 6/19/2003 27,228 8.113 1.055 0.000 No 761.4 6.6 No Yes 7/30/2003 28,292 8.383 1.038 0.000 No 761.0 6.6 No Yes 10/16/2003 30,289 8.896 1.058 0.000 No 719.3 6.6 No Yes 12230/2003 32,121 9.284 1.054 0.000 No 682.4 6.5 No Yes 2/19/2004 36,454 9.380 1.054 0.000 No 647.5 6.5 No Yes 7/15/2004 40,200 10.554 1.132 0.000 No 572.0 6.3 No Yes 9/23/2004 41,990 11.198 1.059 0.000 No 540.1 6.3 No Yes 4/21/2005 47,373 13.124 1.093 0.000 No 494.1 6.2 No Yes 5/31/2005 48,392 13.503 1.090 0.000 No 453.3 6.1 No Yes 1/12/2006 54,140 14.901 1.065 0.000 No 425.7 6.1 No Yes 3/24/2006 54,927 15.120 1.091 0.000 No 390.2 6.0 No Yes 6/8/2006 56,839 15.757 1.069 0.000 No 365.0 5.9 No Yes

10/26/2006 60,414 16.795 1.027 0.000 No 355.4 5.9 No Yes Level : B LPRM ID No. : 355 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/30/1999 149 0.035 1.082 0.000 No 1,155.3 7.1 No Yes 10/18/2001 17,564 4.172 1.074 0.000 No 1,086.0 7.0 No Yes 2/14/2002 17,687 4.794 1.097 0.000 No 990.0 6.9 No Yes 6/6/2002 17,723 5.613 1.002 0.000 No 930.0 6.8 No Yes 9/19/2002 20,399 6.349 1.063 0.000 No 874.9 6.8 No Yes 1/16/2003 23,420 7.155 1.068 0.000 No 819.2 6.7 No Yes 4/10/2003 25,544 7.811 1.083 0.000 No 756.4 6.6 No Yes 7/30/2003 28,292 8.545 1.054 0.000 No 717.6 6.6 No Yes 10/16/2003 30,289 9.073 1.066 0.000 No 673.2 6.5 No Yes 2/19/2004 36,454 9.680 1.187 0.000 No 567.2 6.3 No Yes 6/17/2004 39,500 10.559 1.067 0.000 No 531.5 6.3 No Yes 8/12/2004 40,920 10.998 1.052 0.000 No 505.3 6.2 No Yes 1/6/2005 44,679 12.095 1.073 0.000 No 470.9 6.2 No Yes 3/17/2005 46,469 12.570 1.058 0.000 No 445.1 6.1 No Yes 9/15/2005 51,114 13.892 1.074 0.000 No 414.0 6.0 No Yes 1/12/2006 54,140 14.666 1.088 0.000 No 380.5 5.9 No Yes 3/24/2006 54,927 14.986 1.082 0.000 No 351.7 5.9 No Yes 6/8/2006 56,839 15.595 1.059 0.000 No 332.1 5.8 No Yes 9/21/2006 59,520 16.417 1.059 0.000 No 313.6 5.7 No Yes 10/26/2006 60,414 16.676 1.018 0.000 No 308.0 5.7 No Yes Level : C LPRM ID No. : 361 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.002 1.096 0.000 No 1,140.5 7.0 No Yes 11/30/1999 149 0.029 1.067 0MO No 1,068.9 7.0 No Yes 5/10/2000 4,136 0.793 0.989 0.000 No 1,080.8 7.0 No Yes 12/7/2000 9,499 1.818 1.050 0.000 No 1,018.0 6.9 No Yes 2/22/2001 11,406 2.168 1.066 0.000 No 955.0 6.9 No Yes 4/26/2001 13,036 2.456 1.055 0.000 No 905.2 6.8 No Yes 9/13/2001 16,661 3.214 1.085 0.000 No 834.3 6.7 No Yes 10/18/2001 17,564 3.459 1.057 0.000 No 789.3 6.7 No Yes 2/14/2002 17,687 4.108 1.078 0.000 No 681.7 6.5 No Yes 6/6/2002 17,723 4.686 0.999 0.000 No 635.0 6.5 No Yes

12/20/2001 19,183 3.921 1.074 0.000 No 734.9 6.6 No Yes 8/15/2002 19,529 5.094 1.054 0.000 No 602.5 6.4 No Yes 12/5/2002 22,366 5.820 1.083 0.000 No 556.3 6.3 No Yes 4/10/2003 25,544 6.557 1.068 0.000 No 520.9 6.3 No Yes 7/30/2003 28,292 7.096 1.054 0.000 No 494.2 6.2 No Yes 10/16/2003 30,289 7.606 1.070 0.000 No 461.9 6.1 No Yes 12/30/2003 32,121 8.161 1.053 0.000 No 438.6 6.1 No Yes 2/19/2004 36,454 8.308 1.112 0.000 No 394.4 6.0 No Yes 8/12/2004 40,920 9.329 1.065 0.000 No 370.4 5.9 No Yes 2/3/2005 45,396 10.414 1.078 0.000 No 343.6 5.8 No Yes 8/4/2005 50,051 11.553 1.078 0.000 No 318.7 5.8 No Yes 1/12/2006 54,140 12.741 1.065 0.000 No 299.3 5.7 No Yes 3/24/2006 54,927 13.100 1.143 0.000 No 261.8 5.6 No Yes 8/17/2006 58,629 14.029 1.057 0.000 No 247.7 5.5 No Yes 10/26/2006 60,414 14.461 1.021 0.000 No 242.6 5.5 No Yes Level: D LPRM ID No. : 367 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.001 1.167 0.000 No 1,071.1 7.0 No Yes 11/30/1999 149 0.022 1.069 0.000 No 1,002.0 6.9 No Yes 12/27/1999 816 0.126 1.050 0.000 No 954.3 6.9 No Yes 6/14/2000 5,029 0.738 0.946 0.000 No 1,008.7 6.9 No Yes 1/18/2001 10,585 1.749 1.061 0.000 No 950.7 6.9 No Yes 4/26/2001 13,036 2.108 1.074 0.000 No 885.2 6.8 No Yes 9/13/2001 16,661 2.763 1.081 0.000 No 818.9 6.7 No Yes 2/14/2002 17,687 3.418 1.059 0.000 No 694.8 6.5 No Yes 11/15/2001 18,288 3.102 1.052 0.000 No 778.4 6.7 No Yes 12/20/2001 19,183 3.294 1.058 0.000 No 735.8 6.6 No Yes 8/15/2002 19,529 3.789 1.076 0.000 No 645.7 6.5 No Yes 7/30/2003 28,292 4.696 1.011 0.000 No 646.0 6.5 No Yes 9/11/2003 29,387 4.859 1.096 0.000 No 589.4 6.4 No Yes 2/19/2004 36,454 5.460 1.086 0.000 No 542.7 6.3 No Yes 6/17/2004 39,500 5.783 1.070 0.000 No 507.2 6.2 No Yes 8/12/2004 40,920 5.995 1.053 0.000 No 481.7 6.2 No Yes 9/23/2004 41,990 6.159 0.914 0.000 No 527.0 6.3 No Yes 12/9/2004 43,958 6.457 1.072 0.000 No 491.6 6.2 No Yes 6/30/2005 49,160 7.349 1.090 0.000 No 451.0 6.1 No Yes

String No. :

Coordinates:

Level :

36 17 A

Serial No.: 03s61365 Type : NA300 LPRM ID No.: 505 Cumulative Core Beginning Cycle Installed:

Average Exposure at BOC:

of Life Calibration Current:

18,500 1,250.0 11 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/25/2004 1,043 0.349 1.130 0.000 No 1,106.2 7.0 No Yes 7/15/2004 3,900 1.363 0.921 0.000 No 1,201.1 7.1 No Yes 3/24/2006 18,627 5.854 1.239 0.000 No 956.0 6.9 No Yes 9/21/2006 23,220 7.109 1.082 0.000 No 894.0 6.8 No Yes 10/26/2006 24,114 7.390 1.033 0.000 No 865.4 6.8 No Yes Level: B LPRM ID No.: 515 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 9/23/2004 5,690 1.697 0.945 0.000 No 1,322.8 7.2 No Yes 1/6/2005 8,379 2.419 0.946 0.000 No 1,398.3 7.2 No Yes 1/12/2006 17,840 5.015 1.001 0.000 No 1,396.9 7.2 No Yes Level: C LPRM ID No.: 525 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 9/23/2004 5,690 1.335 0.929 0.000 No 1,345.5 7.2 No Yes 1/6/2005 8,379 1.930 0.936 0.000 No 1,437.5 7.3 No Yes 9/15/2005 14,814 3.502 0.935 0.000 No 1,537.5 7.3 No Yes 3/24/2006 18,627 4.742 1.478 0.000 No 1,040.2 6.9 No Yes 10/26/2006 24,114 6.071 0.985 0.000 No 1,056.1 7.0 No Yes Level: D LPRM ID No. : 535 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/25/2004 1,043 0.117 0.923 0.000 No 1,354.3 7.2 No Yes 1/12/2006 54,140 8.554 1.000 0.000 No 413.0 6.0 No Yes 3/24/2006 54,927 8.877 1.057 0.000 No 390.7 6.0 No Yes 7/13/2006 57,733 9.351 1.073 0.000 No 364.1 5.9 No Yes 10/26/2006 60,414 9.953 1.040 0.000 No 350.1 5.9 No Yes

String No. : 37 Serial No. : 00s19548 Cycle Installed:

10 Coordinates:

Level:

17 A

Type :

LPRM ID No. :

NA300 407 Cumulative Core Beginning Average Exposure at BOC:

of Life Calibration Current:

37,300 700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.058 1.156 0.000 No 1,081.0 7.0 No Yes 6/6/2002 223 0.818 1.055 0.000 No 1,024.6 6.9 No Yes 10/24/2002 3,799 1.961 1.067 0.000 No 960.3 6.9 No Yes 2126/2003 6,974 3.006 1.067 0.000 No 900.0 6.8 No Yes 4/10/2003 8,044 3.420 1.083 0.000 No 831.0 6.7 No Yes 6119/2003 9,728 4.053 1.099 0.000 No 756.2 6.6 No Yes 7/30/2003 10,792 4.394 1.048 0.000 No 756.0 6.6 No Yes 9/11/2003 11,887 4.672 1.080 0.000 No 700.0 6.6 No Yes 12/30/2003 14,621 5.198 1.062 0.000 No 659.1 6.5 No Yes 5/6/2004 20,923 5,903 1.128 0.000 No 584.3 6.4 No Yes 9/23/2004 24,490 7.004 1.061 0.000 No 550.7 6.3 No Yes 2/3/2005 27,896 7.953 1.053 0.000 No 523.0 6.3 No Yes 5/31/2005 30,892 8.778 1.062 0.000 No 492.5 6.2 No Yes 3/2412006 37,427 10.494 1.183 0.000 No 416.3 6.0 No Yes 6/8/2006 39,339 11.124 1.059 0.000 No 393.1 6.0 No Yes 9/21/2006 42,020 11.923 1.063 0.000 No 369.8 5.9 No Yes 1012612006 42,914 12.139 0.995 0.000 No 371.7 5.9 No Yes Level: B LPRM ID No. : 415 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.054 1.125 0.000 No 1,111.0 7.0 No Yes 1215/2002 4,866 2.212 1.092 0.000 No 1,017.4 6.9 No Yes 2/26/2003 6,974 2.853 1.090 0.000 No 933.4 6.8 No Yes 5/1512003 8,890 3.421 1.079 0.000 No 865.1 6.8 No Yes 7/30/2003 10,792 3.973 1.086 0.000 No 796.6 6.7 No Yes 6/17/2004 3,200 0.385 1.053 0.000 No 1,286.1 7.2 No Yes 10/28/2004 6,591 0.914 0.934 0.000 No 1,377.0 7.2 No Yes 3/17/2005 10,169 1.499 0.940 0.000 No 1,464.9 7.3 No Yes 10/20/2005 15,715 2.633 0.945 0.000 No 1,550.0 7.3 No Yes 3/24/2006 18,627 3.469 1.253 0.000 No 1,237.0 7.1 No Yes 10/26/2006 24,114 4.474 0.992 0,000 No 1,247.0 7.1 No Yes

11/20/2003 13,694 4.700 1.081 0.000 No 736.9 6.6 No Yes 2/19/2004 18,954 5.068 1.153 0.000 No 639.1 6.5 No Yes 6/17/2004 22,000 5.965 1.055 0.000 No 605.8 6.4 No Yes 10/28/2004 25,391 6.861 1.051 0.000 No 576.4 6.4 No Yes 4/21/2005 29,873 7.880 1.056 0.000 No 545.8 6.3 No Yes 8/4/2005 32,551 8.542 1.055 0.000 No 517.4 6.2 No Yes 1/12/2006 36,640 9.571 1.054 0.000 No 490.8 6.2 No Yes 3/24/2006 37,427 9.863 1.157 0.000 No 424.2 6.1 No Yes 7/13/2006 40,233 10.658 1.051 0.000 No 403.7 6.0 No Yes 10/26/2006 42,914 11.364 1.044 0.000 No 386.6 6.0 No Yes Level: C LPRM ID No. : 423 Beginning of Life Calibration Current :

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.033 1.044 0.000 No 1,250.0 7.1 No Yes 3/29/2002 1,270 0.231 1.101 0.000 No 1,135.3 7.0 No Yes 8/15/2002 2,029 0.830 0.929 0.000 No 1,222.1 7.1 No Yes 2/26/2003 6,974 1.828 1.055 0.000 No 1,158.4 7.1 No Yes 6/19/2003 9,728 2.349 1.061 0.000 No 1,091.8 7.0 No Yes 7/30/2003 10,792 2.584 1.050 0.000 No 1,092.0 7.0 No Yes 9/11/2003 11,887 2.844 1.068 0.000 No 1,022.5 6.9 No Yes 1/6/2005 27,179 5.536 1.444 0.000 No 707.0 6.6 No Yes 8/4/2005 32,551 6.656 1.062 0.000 No 665.7 6.5 No Yes 12/1/2005 35,567 7.440 1.051 0.000 No 633.4 6.5 No Yes 3/24/2006 37,427 8.067 1.226 0.000 No 516.7 6.2 No Yes 8/17/2006 41,129 8.875 1.058 0.000 No 488.3 6.2 No Yes 10/26/2006 42,914 9.221 1,013 0.000 No 482.1 6.2 No Yes Level: D LPRM ID No.: 431 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.011 1.048 0.000 No 1,250.0 7.1 No Yes 3/29/2002 1,270 0.077 1.124 0.000 No 1,112.1 7.0 No Yes 9/19/2002 2,899 0.352 0.949 0.000 No 1,171.9 7.1 No Yes 4/10/2003 8,044 0.810 0.939 0.000 No 1,248.0 7.1 No Yes 7/30/2003 10,792 1.070 0.987 0.000 No 1,248.0 7.1 No Yes 3125/2004 19,843 1.834 1.135 0.000 No 1,099.6 7.0 No Yes 5/6/2004 20,923 1.946 0.937 0.000 No 1,173.5 7.1 No Yes 8/12/2004 23,420 2.265 1.059 0.000 No 1,108.1 7.0 No Yes

String No.: 38 Serial No.: 95SO1706 Cycle Installed:

8 Coordinates: 17 Type : NA300 Cumulative Core Average Exposure at BOC:

67,204 Level: A LPRM ID No.: 81 Beginning of Life Calibration Current:

1,143.0 Total Pre-Cal Post-Cal Gaf s Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.253 1.072 0.000 Yes 1,045.0 7.0 No Yes 8/25/1998 2,824 0.335 0.771 0.000 No 1,097.0 7.0 No Yes 9/29/1998 3,685 0.439 1.044 0.000 No 1,050.8 7.0 No Yes 6/2411999 9,908 1.171 0.879 0.000 No 1,164.0 7.1 No Yes 8/4/1999 10,769 1.271 1.077 0.000 No 1,178.0 7.1 No Yes 9/17/1999 11,716 1.368 1.085 0.000 No 1,085.7 7.0 No Yes 11/30/1999 12,553 1.448 1.101 0.000 No 986.1 6.9 No Yes 9/28/2000 20,178 2.639 1.069 0.000 No 922.5 6.8 No Yes 1/18/2001 22,989 3.140 1.067 0.000 No 864.5 6.8 No Yes 7/7/2001 27,300 3.989 1.099 0.000 No 786.7 6.7 No Yes 8/17/2001 28,366 4.212 1.060 0.000 No 742.1 6.6 No Yes 2/14/2002 30,091 4.800 1.059 0.000 No 662.4 6.5 No Yes 6/6/2002 30,127 5.211 1.052 0.000 No 629.6 6.4 No Yes 11/15/2001 30,692 4.591 1.058 0.000 No 701.5 6.6 No Yes 9/19/2002 32,803 5.666 1.051 0.000 No 564.0 6.3 No Yes 7/30/2003 40,696 7.053 1.049 0.000 No 564.0 6.3 No Yes 10/16/2003 42,693 7.301 1.094 0.000 No 527.0 6.3 No Yes 5/6/2004 50,827 7.792 1.054 0.000 No 500.0 6.2 No Yes 7/15/2004 52,604 8.004 1.052 0.000 No 489.0 6.2 No Yes 6/30/2005 61,564 8.950 0.948 0.000 No 515.8 6.2 No Yes 10/20/2005 64,419 9.214 0.919 0.000 No 561.0 6.3 No Yes 1/12/2006 66,544 9.383 0.947 0.000 No 592.4 6.4 No Yes 3/24/2006 67,331 9.463 1.244 0.000 No 476.2 6.2 No Yes 2/3/2005 27,896 2.886 1.036 0.000 No 1,069.6 7.0 No Yes 4/2112005 29,873 3.238 1.103 0.000 No 1,004.6 6.9 No Yes 6/30/2005 31,660 3.555 1.055 0.000 No 952.3 6.9 No Yes 9/15/2005 33,614 3.937 1.060 0.000 No 898.4 6.8 No Yes 12/1/2005 35,567 4.391 1.068 0.000 No 841.2 6.7 No Yes 3/24/2006 37,427 4.916 1.092 0.000 No 770.3 6.6 No Yes 5/4/2006 38,475 5.046 1.054 0.000 No 730.8 6.6 No Yes 10/26/2006 42,914 5.688 1.002 0.000 No 729.4 6.6 No Yes

10/26/2006 Level:

72,818 B

10.141 LPRM ID No.:

0.997 167 0.000 Beginning No of Life Calibration 477.6 Current:

6.2 No 1,171.0 Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.373 1.027 0.000 Yes 1,101.0 7.0 No Yes 8/25/1998 2,824 0.472 0.995 0.000 No 1,106.5 7.0 No Yes 9/29/1998 3,685 0.625 1.010 0.000 No 1,095.6 7.0 No Yes 12/29/1998 5,733 0.976 0.886 0.000 No 1,236.5 7.1 No Yes 6/24/1999 9,908 1.665 1.058 0.000 No 1,168.8 7.1 No Yes 11/30/1999 12,553 2.030 1.115 0.000 No 1,048.2 7.0 No Yes 3/8/2000 14,988 2.470 1.063 0.000 No 986.1 6.9 No Yes 6/14/2000 17,433 2.925 1.069 0.000 No 922.4 6.8 No Yes 8/24/2000 19,269 3.276 1.051 0.00.0 No 877.7 6.8 No Yes 11/4/2000 21,053 3.624 1.069 0.000 No 819.0 6.7 No Yes 1/18/2001 22,989 3.997 1.066 0.000 No 768.3 6.6 No Yes 3/22/2001 24,535 4.291 1.074 0.000 No 715.4 6.6 No Yes 6/7/2001 26,529 4.673 1.054 0.000 No 678.7 6.5 No Yes 7/7/2001 27,300 4.820 1.054 0.000 No 643.9 6.5 No Yes 8/17/2001 28,366 5.029 1.064 0.000 No 605.2 6.4 No Yes 2/14/2002 30,091 5.728 1.123 0.000 No 538.9 6.3 No Yes 8/15/2002 31,933 6.582 1.073 0.000 No 502.3 6.2 No Yes 10/24/2002 33,703 6.933 1.056 0.000 No 475.6 6.2 No Yes 4/10/2003 37,948 7.775 1.066 0.000 No 446.2 6.1 No Yes 7/30/2003 40,696 8.310 1.082 0.000 No 412.4 6.0 No Yes 2/19/2004 48,858 9.036 1.071 0.000 No 385.0 6.0 No Yes 7/15/2004 52,604 9.620 1.051 0.000 No 366.3 5.9 No Yes 3/17/2005 58,873 10.448 1.057 0.000 No 346.6 5.8 No Yes 1/12/2006 66,544 11.314 0.957 0.000 No 376.0 5.9 No Yes 3/24/2006 67,331 11.434 1.206 0.000 No 311.8 5.7 No Yes 10/26/2006 72,818 12.258 1.036 0.000 No 300.9 5.7 No Yes Level: C LPRM ID No.: 253 Beginning of Life Calibration Current:

1,153.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp ?

Value 9/12/1996 1,276 0.339 0.993 0.000 Yes 1,084.0 7.0 No Yes 8/25/1998 2,824 0.397 1.005 0.000 No 1,078.6 7.0 No Yes 9/29/1998 3,685 0.521 0.994 0.000 No 1,085.1 7.0 No Yes 2/4/1999 6,618 0.956 0.976 0.000 No 1,111.8 7.0 No Yes

Level: D LPRM ID No.: 339 Beginning of Life Calibration Current :

1,186.0 Total Pre-Cal Post-Cal Gaf s Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.223 0.995 0.000 Yes 1,142.0 7.0 No Yes 8/25/1998 2,824 0.243 1.040 0.000 No 1,098.1 7.0 No Yes 9/29/1998 3,685 0.317 0.985 0.000 No 1,114.8 7.0 No Yes 11/30/1999 12,553 1.280 1.105 0.000 No 1,008.9 6.9 No Yes 12/7/2000 21,903 2.076 1.051 0.000 No 959.9 6.9 No Yes 4/26/2001 25,440 2.449 1.053 0.000 No 911.6 6.8 No Yes 10/18/2001 29,968 3.007 1.055 0.000 No 864.1 6.8 No Yes 2/14/2002 30,091 3.311 1.132 0.000 No 763.3 6.6 No Yes 7/30/2003 40,696 3.986 1.025 0.000 No 763.0 6.6 No Yes 12/30/2003 44,525 4.343 1.061 0.000 No 719.1 6.6 No Yes 2/19/2004 48,858 4.396 0.924 0.000 No 778.3 6.7 No Yes 8/12/2004 53,324 4.827 1.084 0.000 No 718.0 6.6 No Yes 1/612005 57,083 5.257 1.068 0.000 No 672.3 6.5 No Yes 6/30/2005 61,564 5.861 1.059 0.000 No 634.8 6.5 No Yes 10/20/2005 64,419 6.278 1.060 0.000 No 599.0 6.4 No Yes 6/8/2006 69,243 6.971 1.071 0.000 No 559.3 6.3 No Yes 10/26/2006 72,818 7.360 0.991 0.000 No 564.4 6.3 No Yes 3/11/1999 7,477 1.084 0.977 0.000 No 1,085.0 7.0 No Yes 11/30/1999 12,553 1.898 1.056 0.000 No 1,027.5 6.9 No Yes 4/12/2000 15,849 2.385 1.052 0.000 No 976.7 6.9 No Yes 11/4/2000 21,053 3.138 1.054 0.000 No 926.6 6.8 No Yes 2/22/2001 23,810 3.591 1.082 0.000 No 856.4 6.8 No Yes 6/7/2001 26,529 4.056 1.069 0.000 No 801.1 6.7 No Yes 8/17/2001 28,366 4.387 1.080 0.000 No 741.8 6.6 No Yes 2/14/2002 30,091 5.098 1.082 0.000 No 648.6 6.5 No Yes 11/15/2001 30,692 4.811 1.057 0.000 No 701.8 6.6 No Yes 10/24/2002 33,703 5.850 1.059 0.000 No 612.5 6.4 No Yes 7/30/2003 40,696 6.773 1.084 0.000 No 565.0 6.3 No Yes 12130/2003 44,525 7.438 1.057 0.000 No 534.5 6.3 No Yes 10/28/2004 55,295 8.513 1.060 0.000 No 504.3 6.2 No Yes 3/17/2005 58,873 9.028 1.054 0.000 No 478.4 6.2 No Yes 8/4/2005 62,455 9.511 1.058 0.000 No 452.2 6.1 No Yes 3/24/2006 67,331 10.295 1.091 0.000 No 414.5 6.0 No Yes 10/26/2006 72,818 10.993 1.043 0.000 No 397.4 6.0 No Yes

String No.: 39 Coordinates: 9 Level: A Serial No.: 05s105129 Type: NA300 LPRM ID No. : 584 Cycle Installed:

Cumulative Core Average Exposure at BOC:

Beginning of Life Calibration Current:

0 1,250.0 12 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 5/4/2006 1,175 0.291 1.077 0.000 No 1,160.6 7.1 No Yes 7/13/2006 2,933 0.694 1.054 0.000 No 1,101.2 7.0 No Yes 8/17/2006 3,829 0.892 0.920 0.000 No 1,196.9 7.1 No Yes 9/21/2006 4,720 1.085 1.093 0.000 No 1,095.1 7.0 No Yes 10/26/2006 5,614 1.278 1.004 0.000 No 1,090.7 7.0 No Yes Level: B LPRM ID No. : 592 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 127 0.030 1.088 0.000 No 1,148.9 7.0 No Yes 5/4/2006 1,175 0.276 1.066 0.000 No 1,07T8 7.0 No Yes 10/26/2006 5,614 1.283 0.974 0.000 No 1,106.5 7.0 No Yes Level: C LPRM ID No. : 600 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 6/8/2006 2,039 0.364 1.060 0.000 No 1,179.2 7.1 No Yes 10/26/2006 5,614 1.025 0.955 0.000 No 1,234.8 7.1 No Yes Level: D LPRM ID No.: 608 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/16/2006 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 8/17/2006 3,829 0.515 1.051 0.000 No 1,189.3 7.1 No Yes 9/21/2006 4,720 0.643 0.937 0.000 No 1,269.3 7.1 No Yes 10/26/2006 5,614 0.762 0.981 0.000 No 1,293.9 7.2 No Yes String No.: 40 Serial No. : 95s01704 Cycle Installed:

9 Coordinates: 9 Type : NA300 Cumulative Core Average Exposure at BOC:

54,800 Level: A LPRM ID No. : 350 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.003 1.093 0.000 No 1,143.6 7.0 No Yes 12/27/1999 816 0.212 1.062 0.000 No 1,076.9 7.0 No Yes 6/14/2000 5,029 1.352 0.949 0.000 No 1,134.7 7.0 No Yes 9/28/2000 7,774 2.095 1.069 0.000 No 1,061.5 7.0 No Yes 2/22/2001 11,406 2.969 1.082 0.000 No 981.1 6.9 No Yes 4/26/2001 13,036 3.393 1.074 0.000 No 913.5 6.8 No Yes 6/7/2001 14,125 3.661 1.059 0.000 No 862.6 6.8 No Yes 8/17/2001 15,962 4.157 1.088 0.000 No 792.8 6.7 No Yes 10/18/2001 17,564 4.584 1.079 0.000 No 734.8 6.6 No Yes 2/14/2002 17,687 5.159 1.083 0.000 No 678.4 6.5 No Yes 6/6/2002 17,723 5.943 1.001 0.000 No 612.0 6.4 No Yes 3/29/2002 18,770 5.490 1.052 0.000 No 644.9 6.5 No Yes 8/15/2002 19,529 6.526 1.066 0.000 No 574.1 6.4 No Yes 10/24/2002 21,299 7.025 1.077 0.000 No 533.1 6.3 No Yes 2/26/2003 24,474 7.835 1.094 0.000 No 487.3 6.2 No Yes 6/19/2003 27,228 8.724 1.090 0.000 No 447.0 6.1 No Yes 7/30/2003 28,292 9.020 1.009 0.000 No 447.0 6.1 No Yes 9/11/2003 29,387 9.284 1.060 0.000 No 421.7 6.0 No Yes 6/17/2004 39,500 10.572 1.074 0.000 No 392.6 6.0 No Yes 7/15/2004 40,200 10.731 0.941 0.000 No 417.3 6.0 No Yes 9/23/2004 41,990 11.169 1.055 0.000 No 395.5 6.0 No Yes 10/28/2004 42,891 11.446 1.121 0.000 No 352.8 5.9 No Yes 1219/2004 43,958 11.771 0.893 0.000 No 395.1 6.0 No Yes 1/6/2005 44,679 11.944 1.101 0.000 No 358.8 5.9 No Yes 2/3/2005 45,396 12.124 0.925 0.000 No 387.9 6.0 No Yes 3/17/2005 46,469 12.486 1.052 0.000 No 368.8 5.9 No Yes 5/31/2005 48,392 13.177 1.107 0.000 No 333.1 5.8 No Yes 6/30/2005 49,160 13.441 0.942 0.000 No 353.6 5.9 No Yes 8/4/2005 50,051 13.734 1.082 0.000 No 326.8 5.8 No Yes 1/12/2006 54,140 14.802 0.969 0.000 No 303.0 5.7 No Yes 8/17/2006 58,629 15.946 1.084 0.000 No 279.5 5.6 No Yes 10/26/2006 60,414 16.443 1.049 0.000 No 266.5 5.6 No Yes Level: B LPRM ID No. : 356 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.004 1.080 0.000 No 1,157.4 7.1 No Yes

4/26/2001 13,036 3.366 1.058 0.000 No 1,094.0 7.0 No Yes 7/7/2001 14,896 3.817 1.061 0.000 No 1,031.1 6.9 No Yes 9/13/2001 16,661 4.299 1.063 0.000 No 970.0 6.9 No Yes 2/14/2002 17,687 5.187 1.073 0.000 No 859.3 6.8 No Yes 6/6/2002 17,723 5.966 1.059 0.000 No 759.7 6.6 No Yes 3/29/2002 18,770 5.512 1.068 0.000 No 804.6 6.7 No Yes 12/20/2001 19,183 4.991 1.052 0.000 No 922.0 6.8 No Yes 8/15/2002 19,529 6.514 1.072 0.000 No 708.7 6.6 No Yes 10/24/2002 21,299 7.027 1.089 0.000 No 650.8 6.5 No Yes 1/16/2003 23,420 7.606 1.073 0.000 No 606.5 6.4 No Yes 4/10/2003 25,544 8.160 1.074 0.000 No 564.7 6.3 No Yes 7/30/2003 28,292 8.863 1.087 0.000 No 519.5 6.3 No Yes 10/16/2003 30,289 9.349 1.070 0.000 No 485.5 6.2 No Yes 12/30/2003 32,121 9.770 1.068 0.000 No 454.6 6.1 No Yes 2/19/2004 36,454 9.883 1.092 0.000 No 416.3 6.0 No Yes 7/15/2004 40,200 10.789 1.053 0.000 No 395.4 6.0 No Yes 1/6/2005 44,679 11.875 1.057 0.000 No 374.1 5.9 No Yes 3/17/2005 46,469 12.300 1.051 0.000 No 355.9 5.9 No Yes 8/4/2005 50,051 13.177 1.065 0.000 No 334.2 5.8 No Yes 1/12/2006 54,140 14.251 1.053 0.000 No 300.0 5.7 No Yes 6/8/2006 56,839 15.053 1.079 0.000 No 278.0 5.6 No Yes 10/26/2006 60,414 15.938 1.041 0.000 No 267.1 5.6 No Yes Level: C LPRM ID No. : 362 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 11/24/1999 13 0.003 1.102 0.000 No 1,134.3 7.0 No Yes 9/28/2000 7,774 1.552 0.934 0.000 No 1,214.5 7.1 No Yes 6/7/2001 14,125 3.139 1.065 0.000 No 1,140.3 7.0 No Yes 8/17/2001 15,962 3.624 1.092 0.000 No 1,044.3 7.0 No Yes 10/18/2001 17,564 4.053 1.050 0.000 No 994.5 6.9 No Yes 2/14/2002 17,687 4.671 1.097 0.000 No 906.6 6.8 No Yes 3/29/2002 18,770 4.872 1.084 0.000 No 836.3 6.7 No Yes 8/15/2002 19,529 5.491 1.093 0.000 No 765.2 6.6 No Yes 12/5/2002 22,366 6.104 1.081 0.000 No 707.8 6.6 No Yes 4/10/2003 25,544 6.638 1.088 0.000 No 650.6 6.5 No Yes 7/30/2003 28,292 7.066 1.056 0.000 No 616.1 6.4 No Yes 10/16/2003 30,289 7.454 1.053 0.000 No 585.1 6.4 No Yes

String No. : 41 Serial No.: OOs19543 Cycle Installed:

10 Level: D LPRM ID No.: 368 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/2/2000 1,724 0.205 0.943 0.000 No 1,325.6 7.2 No Yes 3/8/2000 2,584 0.307 1.096 0.000 No 1,209.4 7.1 No Yes 4/12/2000 3,445 0.412 0.897 0.000 No 1,237.0 7.1 No Yes 5/10/2000 4,136 0.501 0.938 0.000 No 1,318.8 7.2 No Yes 3/29/2002 18,770 3.285 1.075 0.000 No 1,226.8 7.1 No Yes 1/16/2003 23,420 3.832 0.949 0.000 No 1,292.7 7.2 No Yes 4/10/2003 25,544 3.957 1.056 0.000 No 1,224.1 7.1 No Yes 7/30/2003 28,292 4.132 1.001 0.000 No 1,224.0 7.1 No Yes 3/25/2004 37,343 4.661 1.065 0.000 No 1,149.3 7.0 No Yes 6/17/2004 39,500 4.883 0.944 0.000 No 1,217.5 7.1 No Yes 7/15/2004 40,200 4.966 1.111 0.000 No 1,095.8 7.0 No Yes 10/28/2004 42,891 5.310 0.880 0.000 No 1,245.3 7.1 No Yes 1219/2004 43,958 5.453 1.173 0.000 No 1,061.6 7.0 No Yes 1/6/2005 44,679 5.578 0.912 0.000 No 1,164.0 7.1 No Yes 2/3/2005 45,396 5.705 1.141 0.000 No 1,020.2 6.9 No Yes 5/31/2005 48,392 6.166 0.937 0.000 No 1,088.8 7.0 No Yes 6/30/2005 49,160 6.286 1.081 0.000 No 1,007.2 6.9 No Yes 12/1/2005 53,067 7.074 1.061 0.000 No 949.3 6.9 No Yes 5/4/2006 55,975 7.735 1.089 0.000 No 871.7 6.8 No Yes 7/13/2006 57,733 8.048 1.073 0.000 No 812.4 6.7 No Yes 10/26/2006 60,414 8.553 1.006 0.000 No 807.6 6.7 No Yes 12/30/2003 32,121 7.881 1.077 0.000 No 543.3 6.3 No Yes 2/19/2004 36,454 8.004 1.054 0.000 No 515.4 6.2 No Yes 7/15/2004 40,200 8.746 1.062 0.000 No 485.3 6.2 No Yes 1/6/2005 44,679 9.697 1.074 0.000 No 451.9 6.1 No Yes 5/31/2005 48,392 10.518 1.052 0.000 No 429.6 6.1 No Yes 8/4/2005 50,051 10.897 1.060 0.000 No 405.2 6.0 No Yes 12/1/2005 53,067 11.740 1.052 0.000 No 385.2 6.0 No Yes 1/12/2006 54,140 12.059 1.016 0.000 No 359.0 5.9 No Yes 3/24/2006 54,927 12.374 1.082 0.000 No 331.8 5.8 No Yes 7/13/2006 57,733 12.946 1.074 0.000 No 308.9 5.7 No Yes 10/26/2006 60,414 13.507 1.005 0.000 No 307.4 5.7 No Yes

Coordinates: 9 Type : NA300 Cumulative Core Average Exposure at BOC:

37,300 Level :

Total A

LPRM ID No.:

Pre-Cal 408 Beginning Post-Cal of Life Calibration Gaf s Exp.

Current:

700.0 Good Date CAVEC Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.062 1.180 0.000 No 1,059.0 7.0 No Yes 9/19/2002 2,899 1.732 1.079 0.000 No 981.5 6.9 No Yes 1/16/2003 5,920 2.392 1.081 0.000 No 907.9 6.8 No Yes 4/10/2003 8,044 3.036 1.081 0.000 No 839.9 6.7 No Yes 6/19/2003 9,728 3.596 1.063 0.000 No 790.1 6.7 No Yes 7/30/2003 10,792 3.905 1.040 0.000 No 790.0 6.7 No Yes 9/11/2003 11,887 4.179 1.097 0.000 No 720.1 6.6 No Yes 12/30/2003 14,621 4.680 1.052 0.000 No 684.5 6.5 No Yes 5/6/2004 20,923 5.353 1.066 0.000 No 642.2 6.5 No Yes 6/17/2004 22,000 5.667 1.054 0.000 No 609.3 6.4 No Yes 8/12/2004 23,420 5.988 0.945 0.000 No 644.7 6.5 No Yes 9/23/2004 24,490 6.280 1.065 0.000 No 605.4 6.4 No Yes 10/28/2004 25,391 6.586 1.104 0.000 No 548.3 6.3 No Yes 4/21/2005 29,873 8.122 1.145 0.000 No 478.9 6.2 No Yes 5/31/2005 30,892 8.507 0.939 0.000 No 510.0 6.2 No Yes 6/30/2005 31,660 8.736 1.064 0.000 No 479.3 6.2 No Yes 1/12/2006 36,640 9.978 1.017 0.000 No 445.0 6.1 No Yes 3/24/2006 37,427 10.194 1.179 0.000 No 377.4 5.9 No Yes 8/17/2006 41,129 11.134 0.933 0.000 No 404.5 6.0 No Yes 9/21/2006 42,020 11.350 1.125 0.000 No 359.6 5.9 No Yes 10/26/2006 42,914 11.620 1.023 0.000 No 351.5 5.9 No Yes Level: B LPRM ID No. : 416 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf s Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.056 1.140 0.000 No 1,096.0 7.0 No Yes 12/5/2002 4,866 2.158 1.057 0.000 No 1,036.9 6.9 No Yes 1/16/2003 5,920 2.439 1.061 0.000 No 977.3 6.9 No Yes 4/10/2003 8,044 2.987 1.067 0.000 No 915.9 6.8 No Yes 6/19/2003 9,728 3.422 1.071 0.000 No 855.2 6.8 No Yes 7/30/2003 10,792 3.688 1.055 0.000 No 810.6 6.7 No Yes 10/16/2003 12,789 4.179 1.073 0.000 No 755.5 6.6 No Yes 12/30/2003 14,621 4.600 1.053 0.000 No 717.4 6.6 No Yes 2/19/2004 18,954 4.718 1.077 0.000 No 666.1 6.5 No Yes

Level: C LPRM ID No. : 424 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.033 1.072 0.000 No 1,166.0 7.1 No Yes 7/30/2003 10,792 2.436 1.031 0.000 No 1,166.0 7.1 No Yes 10/16/2003 12,789 2.826 1.080 0.000 No 1,079.6 7.0 No Yes 12/30/2003 14,621 3.254 1.057 0.000 No 1,021.4 6.9 No Yes 2/19/2004 18,954 3.377 1.082 0.000 No 944.0 6.9 No Yes 5/6/2004 20,923 3.785 1.059 0.000 No 891.4 6.8 No Yes 9/23/2004 24,490 4.499 1.084 0.000 No 822.3 6.7 No Yes 1/6/2005 27,179 5.113 1.052 0.000 No 781.7 6.7 No Yes 3/17/2005 28,969 5.530 1.059 0.000 No 738.1 6.6 No Yes 6/30/2005 31,660 6.129 1.051 0.000 No 702.3 6.6 No Yes 9/15/2005 33,614 6.604 1.076 0.000 No 652.7 6.5 No Yes 1/12/2006 36,640 7.520 1.071 0.000 No 609.4 6.4 No Yes 3/24/2006 37,427 7.844 1.219 0.000 No 500.0 6.2 No Yes 6/8/2006 39,339 8.261 1.052 0.000 No 475.2 6.2 No Yes 10/26/2006 42,914 9.017 1.026 0.000 No 463.2 6.1 No Yes Level: D LPRM ID No. : 432 Beginning of Life Calibration Current:

700.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/14/2002 187 0.011 1.012 0.000 No 1,250.0 7.1 No Yes 3/29/2002 1,270 0.076 1.076 0.000 No 1,161.7 7.1 No Yes 9/19/2002 2,899 0.354 0.921 0.000 No 1,261.4 7.1 No Yes 12/5/2002 4,866 0.540 1.107 0.000 No 1,250.0 7.1 No Yes 2/26/2003 6,974 0.695 0.939 0.000 No 1,331.2 7.2 No Yes 7/30/2003 10,792 0.929 1.025 0.000 No 1,331.0 7.2 No Yes 5/6/2004 20,923 5.258 1.053 0.000 No 632.6 6.4 No Yes 9/23/2004 24,490 6.148 1.078 0.000 No 586.8 6.4 No Yes 10/28/2004 25,391 6.401 1.003 0.000 No 585.1 6.4 No Yes 1/6/2005 27,179 6.875 1.064 0.000 No 551.5 6.3 No Yes 5/31/2005 30,892 7.860 1.075 0.000 No 513.1 6.2 No Yes 9/15/2005 33,614 8.533 1.053 0.000 No 487.2 6.2 No Yes 1/12/2006 36,640 9.385 1.024 0.000 No 447.0 6.1 No Yes 3/24/2006 37,427 9.685 1.196 0.000 No 373.7 5.9 No Yes 9/21/2006 42,020 10.837 1.058 0.000 No 353.3 5.9 No Yes 10/26/2006 42,914 11.085 1.003 0.000 No 352.2 5.9 No Yes

9/11/2003 11,887 1.021 1.108 0.000 No 1,326.0 7.2 No Yes 3/25/2004 19,843 1.464 1.078 0.000 No 1,230.1 7.1 No Yes 5/6/2004 20,923 1.570 0.932 0.000 No 1,319.8 7.2 No Yes 8/12/2004 23,420 1.887 1.094 0.000 No 1,206.4 7.1 No Yes 1/6/2005 27,179 2.445 1.082 0.000 No 1,115.0 7.0 No Yes 5/31/2005 30,892 3.063 1.093 0.000 No 1,020.1 6.9 No Yes 8/4/2005 32,551 3.326 1.053 0.000 No 968.8 6.9 No Yes 12/1/2005 35,567 3.990 1.087 0.000 No 891.2 6.8 No Yes 3/24/2006 37,427 4.543 1.144 0.000 No 779.0 6.7 No Yes 6/8/2006 39,339 4.836 1.055 0.000 No 738.4 6.6 No Yes 8/17/2006 41,129 5.220 1.090 0.000 No 677.5 6.5 No Yes 10/26/2006 42,914 5.566 0.967 0.000 No 700.6 6.6 No Yes String No.: 42 Serial No.: 03s61363 Cycle Installed:

11 Coordinates: 9 Type : NA300 Cumulative Core Average Exposure at BOC:

18,500 Level: A LPRM ID No.: 506 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/24/2006 18,627 4.928 1.451 0.000 No 861.5 6.8 No Yes 10/26/2006 24,114 6.445 1.034 0.000 No 833.1 6.7 No Yes Level: B LPRM ID No. : 516 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/25/2004 1,043 0.258 1.064 0.000 No 1,174.8 7.1 No Yes 6/17/2004 3,200 0.770 0.946 0.000 No 1,241.9 7.1 No Yes 12/9/2004 7,658 1.864 0.918 0.000 No 1,352.8 7.2 No Yes 5/31/2005 12,092 2.793 0.945 0.000 No 1,431.5 7.3 No Yes 1/12/2006 17,840 4.185 1.051 0.000 No 1,362.1 7.2 No Yes 3/24/2006 18,627 4.467 1.221 0.000 No 1,115.5 7.0 No Yes 10/26/2006 24,114 5.874 1.009 0.000 No 1,105.6 7.0 No Yes Level: C LPRM ID No.: 526 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 9/23/2004 5,690 1.152 0.941 0.000 No 1,311.0 7.2 No Yes

String No.: 43 Serial No. : 95SO1705 Cycle Installed:

8 Coordinates : 9 Type : NA300 Cumulative Core Average Exposure at BOC:

67,204 Level: A LPRM ID No. : 86 Beginning of Life Calibration Current:

1,097.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/1211996 1,276 0.354 1.064 0.000 Yes 1,017.0 6.9 No Yes 8/25/1998 2,824 0.434 0.916 0.000 No 1,110.3 7.0 No Yes 9/29/1998 3,685 0.568 0.970 0.000 No 1,144.6 7.0 No Yes 3/11/1999 7,477 1.032 1.051 0.000 No 1,090.0 7.0 No Yes 11/24/1999 12,417 1.697 1.076 0.000 No 1,013.0 6.9 No Yes 11/30/1999 12,553 1.712 1.054 0.000 No 961.1 6.9 No Yes 8/24/2000 19,269 2.611 0.945 0.000 No 1,017.0 6.9 No Yes 4/26/2001 25,440 3.653 1.061 0.000 No 958.6 6.9 No Yes 9/13/2001 29,065 4.360 1.076 0.000 No 890.9 6.8 No Yes 2/14/2002 30,091 4.849 1.072 0.000 No 831.0 6.7 No Yes 6/6/2002 30,127 5.333 1.023 0.000 No 780.0 6.7 No Yes 8/15/2002 31,933 5.681 1.088 0.000 No 716.9 6.6 No Yes 10/24/2002 33,703 6.004 1.056 0.000 No 678.9 6.5 No Yes 5/15/2003 38,794 6.929 1.053 0.000 No 644.7 6.5 No Yes 7/30/2003 40,696 7.238 1.046 0.000 No 645.0 6.5 No Yes 9/11/2003 41,791 7.379 1.060 0.000 No 608.5 6.4 No Yes 2/19/2004 48,858 7.684 1.098 0.000 No 554.2 6.3 No Yes 5/6/2004 50,827 8.034 1.071 0.000 No 517.4 6.2 No Yes 4/21/2005 3/24/2006 10/26/2006 Level:

11,073 18,627 24,114 D

2.235 4.160 5.275 LPRM ID No.:

0.939 1.146 1.002 536 0.000 0.000 0.000 Beginning No No No of Life Calibration 1,396.2 1,218.3 1,215.9 Current:

7.2 7.1 7.1 No No No 1,250.0 Yes Yes Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 12/30/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 9/23/2004 5,690 0.636 0.933 0.000 No 1,339.8 7.2 No Yes 2/3/2005 9,096 1.124 0.947 0.000 No 1,414.7 7.3 No Yes 5/31/2005 12,092 1.592 0.898 0.000 No 1,575.4 7.4 No Yes 8/4/2005 13,751 1.858 1.089 0.000 No 1,446.7 7.3 No Yes 3/24/2006 18,627 2.971 1.069 0.000 No 1,353.3 7.2 No Yes 10/26/2006 24,114 3.785 0.967 0.000 No 1,399.5 7.2 No Yes

10/20/2005 64,419 9.942 0.938 0.000 No 552.0 6.3 No Yes 1/12/2006 66,544 10.149 0.962 0.000 No 590.0 6.4 No Yes 3/24/2006 67,331 10.249 1.117 0.000 No 528.2 6.3 No Yes 6/8/2006 10/26/2006 Level :

69,243 72,818 B

10.605 11.139 LPRM ID No. :

1.060 0.984 172 0.000 0.000 Beginning No No of Life Calibration 498.3 506.4 Current:

6.2 6.2 No No 1,076.0 Yes Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.445 0.994 0.000 Yes 1,052.0 7.0 No Yes 8/25/1998 2,824 0.547 0.961 0.000 No 1,094.7 7.0 No Yes 9/29/1998 3,685 0.726 1.015 0.000 No 1,078.5 7.0 No Yes 11/30/1999 12,553 2.261 1.067 0.000 No 1,010.8 6.9 No Yes 7/20/2000 18,363 3.315 1.058 0.000 No 955.4 6.9 No Yes 2/22/2001 23,810 4.349 1.064 0.000 No 897.9 6.8 No Yes 6/7/2001 26,529 4.865 1.072 0.000 No 837.6 6.7 No Yes 8/17/2001 28,366 5.222 1.060 0.000 No 790.2 6.7 No Yes 2/14/2002 30,091 5.931 1.091 0.000 No 724.3 6.6 No Yes 6/6/2002 30,127 6.464 1.028 0.000 No 678.0 6.5 No Yes 8/15/2002 31,933 6.835 1.071 0.000 No 633.1 6.5 No Yes 10/24/2002 33,703 7.201 1.066 0.000 No 593.9 6.4 No Yes 4/10/2003 37,948 8.024 1.065 0.000 No 557.6 6.3 No Yes 6/19/2003 39,632 8.306 1.055 0.000 No 528.5 6.3 No Yes 7/30/2003 40,696 8.479 1.016 0.000 No 529.0 6.3 No Yes 11/20/2003 43,598 8.906 1.067 0.000 No 495.8 6.2 No Yes 2/19/2004 48,858 9.112 1.126 0.000 No 440.3 6.1 No Yes 6/17/2004 51,904 9.724 1.066 0.000 No 413.0 6.0 No Yes 10/28/2004 55,295 10.337 1.055 0.000 No 391.5 6.0 No Yes 1/6/2005 57,083 10.617 1.056 0.000 No 370.7 5.9 No Yes 8/4/2005 62,455 11.377 1.057 0.000 No 350.8 5.9 No Yes 1/12/2006 66,544 11.945 0.975 0.000 No 370.0 5.9 No Yes 9/21/2006 71,924 12.956 1.054 0.000 No 351.0 5.9 No Yes 10/26/2006 72,818 13.100 1.004 0.000 No 349.6 5.9 No Yes Level: C LPRM ID No.: 258 Beginning of Life Calibration Current:

1,072.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.371 1.000 0.000 Yes 1,039.0 6.9 No Yes 8/25/1998 2,824 0.442 0.960 0.000 No 1,082.3 7.0 No Yes

9/29/1998 3,685 0.581 1.033 0.000 No 1,047.7 7.0 No Yes 4/15/1999 8,305 1.331 0.953 0.000 No 1,099.4 7.0 No Yes 11/30/1999 12,553 2.088 1.113 0.000 No 987.8 6.9 No Yes 5/10/2000 16,540 2.683 1.053 0.000 No 938.1 6.8 No Yes 8/24/2000 19,269 3.058 1.052 0.000 No 891.7 6.8 No Yes 1/18/2001 22,989 3.654 1.078 0.000 No 827.2 6.7 No Yes 4/26/2001 25,440 4.031 1.076 0.000 No 768.7 6.6 No Yes 8/17/2001 28,366 4.529 1.076 0.000 No 714.4 6.6 No Yes 12/20/2001 31,587 5.116 1.054 0.000 No 677.8 6.5 No Yes 8/15/2002 31,933 5.801 1.064 0.000 No 637.1 6.5 No Yes 4/10/2003 37,948 6.594 1.052 0.000 No 605.6 6.4 No Yes 7/30/2003 40,696 6.904 1.042 0.000 No 606.0 6.4 No Yes 10/16/2003 42,693 7.171 1.064 0.000 No 569.5 6.3 No Yes 2/19/2004 48,858 7.554 1.110 0.000 No 513.1 6.2 No Yes 8/12/2004 53,324 8.295 1.068 0.000 No 480.4 6.2 No Yes 12/9/2004 56,362 8.783 1.057 0.000 No 454.5 6.1 No Yes 5/31/2005 60,796 9.421 1.054 0.000 No 431.2 6.1 No Yes 10/20/2005 64,419 10.012 1.057 0.000 No 408.0 6.0 No Yes 10/26/2006 72,818 11.392 1.039 0.000 No 392.7 6.0 No Yes Level: D LPRM ID No. : 344 Beginning of Life Calibration Current:

1,103.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 1,276 0.255 0.991 0.000 Yes 1,060.0 7.0 No Yes 8/25/1998 2,824 0.263 0.960 0.000 No 1,104.2 7.0 No Yes 9/29/1998 3,685 0.343 0.957 0.000 No 1,153.8 7.1 No Yes 11/30/1999 12,553 1.401 1.123 0.000 No 1,027.4 6.9 No Yes 9/28/2000 20,178 2.053 1.050 0.000 No 978.5 6.9 No Yes 2/22/2001 23,810 2.441 1.067 0.000 No 917.0 6.8 No Yes 10/18/2001 29,968 3.167 1.068 0.000 No 858.7 6.8 No Yes 2/14/2002 30,091 3.468 1.075 0.000 No 798.7 6.7 No Yes 9/19/2002 32,803 3.712 1.071 0.000 No 745.8 6.6 No Yes 2/26/2003 36,878 3.961 0.935 0.000 No 797.6 6.7 No Yes 7/30/2003 40,696 4.153 1.025 0.000 No 798.0 6.7 No Yes 11/20/2003 43,598 4.373 1.052 0.000 No 758.6 6.6 No Yes 3/25/2004 49,747 4.587 1.065 0.000 No 712.3 6.6 No Yes 12/9/2004 56,362 5.308 1.052 0.000 No 677.1 6.5 No Yes 4/21/2005 59,777 5.764 1.051 0.000 No 644.2 6.5 No Yes

8/4/2005 62,455 6.139 1.052 0.000 No 612.4 6.4 No Yes 12/1/2005 65,471 6.640 1.055 0.000 No 580.4 6.4 No Yes 6/8/2006 69,243 7.214 0.949 0.000 No 611.6 6.4 No Yes 7/13/2006 70,137 7.324 1.056 0.000 No 579.2 6.4 No Yes 10/26/2006 72,818 7.643 1.021 0.000 No 567.3 6.3 No Yes

LaSalle County Station Unit 2

LaSalle Unit String No. :

Coordinates :

2 1

57 Serial No. :

Type :

LPRM Data 96SO0501 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC:

Printed :

8 51,228 11/2212006 Level : A LPRM ID No. : 1 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good

% Life Good Date CAVEX Exp GAF GAFpost Corrected CalCur In(CalCur)

Byp.?

Value 4/16/1999 48 0.009 1.007 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.028 1.034 0.000 No 1,250.0 7.1 No Yes 5/18/2000 9,611 1.669 1.037 0.000 No 1,250.0 7.1 No Yes 12/8/2000 14,092 2.308 1.105 0.000 No 1,131.2 7.0 No Yes 1/9/2003 15,550 5.060 1.066 0.000 No 763.6 6.6 No Yes 2/15/2001 15,846 2.551 1.048 0.000 No 1,079.4 7.0 No Yes 7/1222001 19,517 3.035 1.077 0.000 No 1,002.2 6.9 No Yes 1/31/2002 24,595 3.857 1.100 0.000 No 911.1 6.8 No Yes 5/7/2002 26,607 4.195 1.057 0.000 No 862.0 6.8 No Yes 7/18/2002 28,480 4.454 1.059 0.000 No 814.0 6.7 No Yes 4/3/2003 34,037 5.261 1.085 0.000 No 703.8 6.6 No Yes 7/31/2003 36,969 5.752 1.072 0.000 No 656.5 6.5 No Yes 11/13/2003 39,615 6.134 1.052 0.000 No 624.0 6.4 No Yes 6/3/2004 44,858 7.022 1.065 0.000 No 585.9 6.4 No Yes 4/28/2005 52,297 8.090 1.144 0.000 No 512.2 6.2 No Yes 11/17/2005 57,483 8.840 0.937 0.000 No 547.0 6.3 No Yes 2/9/2006 59,635 9.100 1.112 0.000 No 492.0 6.2 No Yes 3/23/2006 60,713 9.234 0.943 0.000 No 521.7 6.3 No Yes 11/21/2006 66,942 9.845 1.009 0.000 No 517.1 6.2 No Yes Level : B LPRM ID No. : 87 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/20/1999 146 0.028 0.000 0.000 No 1,250.0 7.1 Yes No Level : C LPRM ID No. : 1 73 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.007 0.955 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.019 0.982 0.000 No 1,250.0 7.1 No Yes 11/23/1999 5,275 0.703 0.941 0.000 No 1,328.4 7.2 No Yes 5/18/2000 9,611 1.319 0.956 0.000 No 1,328.0 7.2 No Yes 8/10/2000 11,664 1.634 0.947 0.000 No 1,402.3 7.2 No Yes

String No. : 2 Serial No. : 04s82827 Coordinates : 57 Type : NA300

.Cycle Installed :

11 Cumulative Core Average Exposure at BOC :

0 Level : D LPRM ID No. : 259 Beginning of Life Calibration Current:

1,359.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.003 0.922 0.000 No 1,359.0 7.2 No Yes 4/20/1999 146 0.010 1.024 0.000 No 1,250.0 7.1 No Yes 5/18/2000 9,611 0.754 0.948 0.000 No 1,425.0 7.3 No Yes 12/8/2000 14,092 1.198 1.113 0.000 No 1,280.3 7.2 No Yes 2/15/2001 15,846 1.327 0.955 0.000 No 1,340.7 7.2 No Yes 3/14/2002 25,649 2.162 0.948 0.000 No 1,414.2 7.3 No Yes 3/23/2004 42,997 3.559 1.084 0.000 No 1,304.6 7.2 No Yes 6/3/2004 44,858 3.707 0.930 0.000 No 1,402.8 7.2 No Yes 7/8/2004 45,715 3.783 0.920 0.000 No 1,524.8 7.3 No Yes 10/21/2004 48,434 4.088 1.088 0.000 No 1,401.5 7.2 No Yes 3/21/2005 51,328 4.500 1.045 0.000 No 1,401.0 7.2 No Yes 7/7/2005 54,077 4.731 0.949 0.000 No 1,476.3 7.3 No Yes 8/11/2005 54,977 4.812 1.138 0.000 No 1,297.3 7.2 No Yes 11/17/2005 57,483 5.101 1.070 0.000 No 1,212.0 7.1 No Yes 2/9/2006 59,635 5.349 0.949 0.000 No 1,277.0 7.2 No Yes 3/23/2006 60,713 5.490 1.109 0.000 No 1,151.5 7.0 No Yes 7/6/2006 63,402 5.830 1.052 0.000 No 1,094.6 7.0 No Yes 11/21/2006 66,942 6.309 1.041 0.000 No 10515 70 No Yes 12/8/2000 14,092 2.063 1.109 0.000 No 1,264.5 7.1 No Yes 8/16/2001 20,431 3.062 1.060 0.000 No 1,192.9 7.1 No Yes 2/27/2003 33,184 5.039 1.063 0.000 No 1,122.2 7.0 No Yes 11/13/2003 39,615 5.798 1.051 0.000 No 1,067.8 7.0 No Yes 3/23/2004 42,997 6.245 1.054 0.000 No 1,013.1 6.9 No Yes 10/21/2004 48,434 7.068 1.068 0.000 No 948.6 6.9 No Yes 12/29/2004 50,211 7.391 1.069 0.000 No 887.3 6.8 No Yes 7/7/2005 54,077 7.992 1.051 0.000 No 844.3 6.7 No Yes 8/11/2005 54,977 8.123 1.059 0.000 No 797.2 6.7 No Yes 10/13/2005 56,583 8.377 1.058 0.000 No 753.5 6.6 No Yes 12/29/2005 58,559 8.689 1.056 0.000 No 713.6 6.6 No Yes 4/27/2006 61,610 9.157 1.059 0.000 No 673.8 6.5 No Yes 8/10/2006 64,302 9.560 1.070 0.000 No 629.7 6.4 No Yes 11/21/2006 66,942 9.938 1.048 0.000 No 600.9 6.4 No Yes

Level : A LPRM ID No. : 537 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gal's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.016 0.907 0.000 No 1,378.2 7.2 No Yes 4/28/2005 1,069 0.275 1.204 0.000 No 1,144.7 7.0 No Yes 2/9/2006 8,407 1.886 0.934 0.000 No 1,226.0 7.1 No Yes 3/23/2006 9,485 2.087 1.066 0.000 No 1,150.1 7.0 No Yes 7/6/2006 12,174 2.569 0.944 0.000 No 1,218.3 7.1 No Yes 11/21/2006 15,714 3.245 0.973 0.000 No 1,252.1 7.1 No Yes Level : B LPRM ID No. : 547 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.027 0.931 0.000 No 1,342.6 7.2 No Yes 10/19/2006 14,867 3.311 1.010 0.000 No 1,329.3 7.2 No Yes Level : C LPRM ID No. : 557 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.021 1.060 0.000 No 1,179.2 7.1 No Yes 11/17/2005 6,255 1.093 0.947 0.000 No 1,245.0 7.1 No Yes 11/21/2006 15,714 3.111 0.999 0.000 No 1,246.2 7.1 No Yes Level : D LPRM ID No. : 567 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.088 0.884 0.000 No 1,414.0 7.3 No Yes 11/21/2006 15,714 2.071 1.029 0.000 No 1,374.2 7.2 No Yes String No. : 3 Serial No. : 02841541 Cycle Installed :

10 Coordinates : 57 Type : NA300 Cumulative Core Average Exposure at BOC :

18,162 Level : A LPRM ID No. : 433 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gal's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/3/2003 971 0.266 1.087 0.000 No 1,150.0 7.0 No Yes

8/5/2004 13,375 3.570 1.052 0.000 No 1,093.0 7.0 No Yes 3/21/2005 18,262 4.479 1.087 0.000 No 1,005.5 6.9 No Yes 11/17/2005 24,417 5.926 1.052 0.000 No 956.0 6.9 No Yes 6/1/2006 29,438 7.048 0.946 0.000 No 1,010.6 6.9 No Yes 7/6/2006 30,336 7.254 1.065 0.000 No 948.9 6.9 No Yes 11/21/2006 33,876 8.112 0.972 0.000 No 976.2 6.9 No Yes Level : B LPRM ID No. : 449 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 9/4/2003 4,813 1.117 0.937 0.000 No 1,334.0 7.2 No Yes 6/3/2004 11,792 2.754 0.938 0.000 No 1,422.2 7.3 No Yes 9/16/2004 14,457 3.373 1.051 0.000 No 1,353.2 7.2 No Yes 10/21/2004 15,368 3.594 1.051 0.000 No 1,287.5 7.2 No Yes 3/21/2005 18,262 4.253 1.185 0.000 No 1,086.5 7.0 No Yes 2/9/2006 26,569 6.251 1.051 0.000 No 1,034.0 6.9 No Yes 9/14/2006 32,130 7.512 1.075 0.000 No 961.9 6.9 No Yes 11/21/2006 33,876 7.916 1.033 0.000 No 931.1 6.8 No Yes Level : C LPRM ID No. : 465 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/16/2003 5,819 0.833 0.944 0.000 No 1,324.2 7.2 No Yes 6/3/2004 11,792 1.793 0.948 0.000 No 1,396.8 7.2 No Yes 3/21/2005 18,262 3.242 1.226 0.000 No 1,139.3 7.0 No Yes 9/14/2006 32,130 5.973 1.060 0.000 No 1,064.0 7.0 No Yes 11/21/2006 33,876 6.374 0.970 0.000 No 1,096.9 7.0 No Yes Level : D LPRM ID No. : 481 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/16/2003 5,819 0.404 0.930 0.000 No 1,344.1 7.2 No Yes 1/5/2004 7,911 0.587 0.941 0.000 No 1,428.4 7.3 No Yes 7/8/2004 12,649 1.026 0.942 0.000 No 1,516.3 7.3 No Yes 3/21/2005 18,262 1.943 1.119 0.000 No 1,355.1 7.2 No Yes 4/27/2006 28,544 3.092 0.945 0.000 No 1,433.9 7.3 No Yes 6/1/2006 29,438 3.211 1.124 0.000 No 1,275.7 7.2 No Yes

7/6/2006 30,336 3.348 0.935 0.000 No 1,364.4 7.2 No Yes 11/21/2006 String No. :

Coordinates :

33,876 4

57 3.937 Serial No. :

Type :

1.058 M5419 NA300 0.000 Cumulative No Core Average 1,289.6 Cycle Installed :

Exposure at BOC :

7.2 No 61,028 Yes 7

Level : A LPRM ID No. : 4 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 9,490 1.229 1.019 0.000 Yes 1,091.0 7.0 No Yes 11/23/1999 15,075 2.292 1.073 0.000 No 1,016.8 6.9 No Yes 2/3/2000 16,838 2.600 1.053 0.000 No 965.6 6.9 No Yes 5/18/2000 19,411 3.008 1.051 0.000 No 918.7 6.8 No Yes 8/10/2000 21,464 3.434 1.039 0.000 No 885.0 6.8 No Yes 12/8/2000 23,892 3.788 1.165 0.000 No 759.7 6.6 No Yes 3/30/2001 26,762 4.275 1.074 0.000 No 707.3 6.6 No Yes 7/12/2001 29,317 4.673 1.059 0.000 No 667.9 6.5 No Yes 9/20/2001 30,967 4.969 1.050 0.000 No 636.1 6.5 No Yes 12/27/2001 33,507 5.492 1.051 0.000 No 605.2 6.4 No Yes 3/14/2002 35,449 5.953 1.051 0.000 No 575.9 6.4 No Yes 9/26/2002 40,020 6.974 1.072 0.000 No 537.2 6.3 No Yes 2/27/2003 42,984 7.478 1.068 0.000 No 503.0 6.2 No Yes 5/8/2003 44,745 7.890 1.052 0.000 No 478.1 6.2 No Yes 10/16/2003 48,685 8.740 1.052 0.000 No 454.5 6.1 No Yes 1/5/2004 50,777 9.173 1.060 0.000 No 428.8 6.1 No Yes 7/8/2004 55,515 10.355 1.116 0.000 No 384.2 6.0 No Yes 4/28/2005 62,097 11.637 1.166 0.000 No 329.5 5.8 No Yes 10/13/2005 66,383 12.564 1.082 0.000 No 304.5 5.7 No Yes 12/29/2005 68,359 12.920 0.945 0.000 No 322.3 5.8 No Yes 2/9/2006 69,435 13.139 1.061 0.000 No 304.0 5.7 No Yes 6/1/2006 72,304 13.641 0.947 0.000 No 321.0 5.8 No Yes 9/14/2006 74,996 13.934 1.067 0.000 No 300.9 5.7 No Yes 11/21/2006 76,742 14.238 1.002 0.000 No 300.3 5.7 No Yes Level : B LPRM ID No. : 90 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAMEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 9,490 1.695 1.011 0.000 Yes 1,129.0 7.0 No Yes 4/16/1999 9,848 1.737 0.940 0.000 No 1,201.1 7.1 No Yes

5/25/1999 10,770 1.925 1.058 0.000 No 1,135.2 7.0 No Yes 10/14/1999 14,167 2.614 1.059 0.000 No 1,072.0 7.0 No Yes 11/23/1999 15,075 2.800 1.057 0.000 No 1,014.2 6.9 No Yes 3/9/2000 17,697 3.378 1.062 0.000 No 955.0 6.9 No Yes 5/18/2000 19,411 3.774 1.075 0.000 No 888.3 6.8 No Yes 7/5/2000 20,547 4.018 1.058 0.000 No 839.6 6.7 No Yes 10/26/2000 23,420 4.610 1.104 0.000 No 760.5 6.6 No Yes 12/8/2000 23,892 4.698 1.124 0.000 No 676.6 6.5 No Yes 3/30/2001 26,762 5.230 1.108 0.000 No 610.7 6.4 No Yes 7/12/2001 29,317 5.721 1.088 0.000 No 561.3 6.3 No Yes 9/20/2001 30,967 6.066 1.043 0.000 No 538.1 6.3 No Yes 11/29/2001 32,778 6.464 1.091 0.000 No 514.5 6.2 No Yes 5/7/2002 36,407 7.288 1.055 0.000 No 487.7 6.2 No Yes 7/18/2002 38,280 7.709 1.056 0.000 No 461.8 6.1 No Yes 2/27/2003 42,984 8.583 1.101 0.000 No 419.4 6.0 No Yes 5/8/2003 44,745 8.964 1.061 0.000 No 395.3 6.0 No Yes 10/16/2003 48,685 9.793 1.061 0.000 No 372.6 5.9 No Yes 2/16/2004 51,865 10.454 1.100 0.000 No 338.7 5.8 No Yes 9/16/2004 57,323 11.646 1.073 0.000 No 315.7 5.8 No Yes 12/2/2004 59,312 12.085 1.071 0.000 No 294.7 5.7 No Yes 4/28/2005 62,097 12.715 1.127 0.000 No 261.5 5.6 No Yes 8/11/2005 64,777 13.382 1.064 0.000 No 245.8 5.5 No Yes 10/13/2005 66,383 13.753 1.068 0.000 No 230.1 5.4 No Yes 3/23/2006 70,513 14.688 1.060 0.000 No 217.1 5.4 No Yes 9/14/2006 74,996 15.467 1.065 0.000 No 203.9 5.3 No Yes 11/21/2006 76,742 15.808 1.026 0.000 No 198.7 5.3 No Yes Level : C LPRM ID No. : 176 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 9,490 1.824 1.020 0.000 Yes 1,029.0 6.9 No Yes 4/16/1999 9,848 1.886 0.949 0.000 No 1,083.0 7.0 No Yes 11/23/1999 15,075 2.704 1.084 0.000 No 999.1 6.9 No Yes 5/18/2000 19,411 3.434 1.047 0.000 No 999.0 6.9 No Yes 7/5/2000 20,547 3.630 1.080 0.000 No 925.0 6.8 No Yes 10/26/2000 23,420 4.205 1.080 0.000 No 856.5 6.8 No Yes 12/8/2000 23,892 4.308 1.125 0.000 No 761.3 6.6 No Yes 12/12/2002 24,660 7.574 1.060 0.000 No 536.2 63 No Yes

Level : C LPRM ID No. : 558 Beginning of Life Calibration Current :

1,250.0 3/8/2001 26,187 4.714 1.059 0.000 No 718.9 6.6 No Yes 5/24/2001 28,124 5.071 1.065 0.000 No 675.0 6.5 No Yes 8/16/2001 30,231 5.450 1.052 0.000 No 641.7 6.5 No Yes 12/27/2001 33,507 6.016 1.057 0.000 No 607.1 6.4 No Yes 6/13/2002 37,371 6.717 1.068 0.000 No 568.4 6.3 No Yes 2/27/2003 42,984 7.767 1.055 0.000 No 508.3 6.2 No Yes 11/13/2003 49,415 8.620 1.054 0.000 No 482.2 6.2 No Yes 8/5/2004 56,241 9.679 1.061 0.000 No 455.0 6.1 No Yes 10/21/2004 58,234 10.089 1.062 0.000 No 428.4 6.1 No Yes 3/21/2005 61,128 10.752 1.109 0.000 No 386.3 6.0 No Yes 7/7/2005 63,877 11.261 1.059 0.000 No 364.8 5.9 No Yes 11/17/2005 67,283 11.951 1.072 0.000 No 340.0 5.8 No Yes 3/23/2006 70,513 12.637 1.060 0.000 No 320.8 5.8 No Yes 6/1/2006 72,304 13.008 1.060 0.000 No 302.6 5.7 No Yes 11/21/2006 76,742 13.997 1.076 0.000 No 281.2 5.6 No Yes Level : D LPRM ID No. : 262 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value String No. : 5 Serial No. : 04s82826 Cycle Installed :

11 Coordinates: 49 Type: NA300 Cumulative Core Average Exposure at BOC :

0 Level : A LPRM ID No. : 538 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.182 1.111 0.000 No 1,125.1 7.0 No Yes 11/17/2005 6,255 1.043 0.942 0.000 No 1,194.0 7.1 No Yes 12/29/2005 7,331 1.180 1.076 0.000 No 1,109.7 7.0 No Yes 3/23/2006 9,485 1.507 0.943 0.000 No 1,176.7 7.1 No Yes 11/21/2006 15,714 2.212 0.997 0.000 No 1,180.3 7.1 No Yes Level : B LPRM ID No. : 548 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.022 0.956 0.000 No 1,307.5 7.2 No Yes 11/21/2006 15,714 2.653 1.008 0.000 No 1,240.1 7.1 No Yes

String No. :

Coordinates:

6 49 Serial No. :

Type :

02841547 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

18,162 10 Level : A LPRM ID No. : 434 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.028 1.083 0.000 No 1,154.2 7.1 No Yes 10/1612003 5,819 1.298 1.051 0.000 No 1,098.2 7.0 No Yes 10/2112004 15,368 4.440 1.066 0.000 No 1,030.2 6.9 No Yes 4128/2005 19,231 5.330 1.080 0.000 No 953.9 6.9 No Yes 11/17/2005 24,417 6.830 0.941 0.000 No 1,014.0 6.9 No Yes 12/29/2005 25,493 7.088 1.066 0.000 No 951.2 6.9 No Yes 2/9/2006 26,569 7.416 1.079 0.000 No 882.0 6.8 No Yes 9/14/2006 32,130 8.893 1.066 0.000 No 827.4 6.7 No Yes 11/21/2006 33,876 9.377 1.015 0.000 No 815.2 6.7 No Yes Level : B LPRM ID No. : 450 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/3/2003 971 0.292 1.129 0.000 No 1,107.2 7.0 No Yes 6/3/2004 11,792 3.220 0.949 0.000 No 1,158.0 7.1 No Yes 10/21/2004 15,368 4.268 1.058 0.000 No 1,094.5 7.0 No Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/2112005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3121/2005 100 0.017 0.980 0.000 No 1,250.0 7.1 No Yes 11/21/2006 15,714 2.567 1.016 0.000 No 1,230.3 7.1 No Yes Level : D LPRM ID No.: 568 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.010 0.847 0.000 No 1,475.8 7.3 No Yes 7/7/2005 2,849 0.280 1.067 0.000 No 1,383.1 7.2 No Yes 10/13/2005 5,355 0.569 0.936 0.000 No 1,477.7 7.3 No Yes 11/1712005 6,255 0.693 1.079 0.000 No 1,370.0 7.2 No Yes 12/29/2005 7,331 0.835 0.947 0.000 No 1,446.7 7.3 No Yes 11/21/2006 15,714 1.986 1.023 0.000 No 1,414.1 7.3 No Yes

3/21/2005 18,262 5.001 1.080 0.000 No 1,013.4 6.9 No Yes 9/8/2005 22,627 6.249 1.064 0.000 No 952.5 6.9 No Yes 7/6/2006 30,336 8.301 1.078 0.000 No 883.6 6.8 No Yes 9/14/2006 32,130 8.729 1.094 0.000 No 807.6 6.7 No Yes 11/21/2006 33,876 9.186 1.103 0.000 No 732.2 6.6 No Yes Level : C LPRM ID No. : 466 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2127/2003 118 0.024 1.057 0.000 No 1,182.6 7.1 No Yes 1/21/2005 17,737 4.090 1.053 0.000 No 1,123.1 7.0 No Yes 3/21/2005 18,262 4.236 1.094 0.000 No 1,026.6 6.9 No Yes 6/1/2006 29,438 6.950 1.069 0.000 No 960.3 6.9 No Yes 8/10/2006 31,236 7.379 1.059 0.000 No 906.8 6.8 No Yes 11/21/2006 33,876 8.058 1.100 0.000 No 824.4 6.7 No Yes Level : D LPRM ID No. : 482 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/3/2003 971 0.088 1.095 0.000 No 1,141.6 7.0 No Yes 10/1612003 5,819 0.624 0.934 0.000 No 1,222.2 7.1 No Yes 7/8/2004 12,649 1.531 0.900 0.000 No 1,358.0 7.2 No Yes 312112005 18,262 2.784 1.094 0.000 No 1,241.3 7.1 No Yes 8/11/2005 21,911 3.212 0.933 0.000 No 1,330.5 7.2 No Yes 9/8/2005 22,627 3.307 1.064 0.000 No 1,250.4 7.1 No Yes 11/17/2005 24,417 3.602 1.214 0.000 No 1,030.0 6.9 No Yes 2/9/2006 26,569 3.939 0.911 0.000 No 1,300.0 7.2 No Yes 6/1/2006 29,438 4.448 1.061 0.000 No 1,225.3 7.1 No Yes 11121/2006 33,876 5.251 0.988 0.000 No 1,240.1 7.1 No Yes String No. : 7 Serial No. : 02S41544 Cycle Installed :

10 Coordinates : 49 Type : NA300 Cumulative Core Average Exposure at BOC :

18,162 Level : A LPRM ID No. : 435 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.031 1.102 0.000 No 1,134.3 7.0 No Yes 4/3/2003 971 0.255 1.062 0.000 No 1,068.1 7.0 No Yes

10116/2003 5,819 1.496 1.052 0.000 No 1,015.3 6.9 No Yes 7/8/2004 12,649 3.528 0.946 0.000 No 1,073.2 7.0 No Yes 3/21/2005 18,262 4.854 1.105 0.000 No 971.3 6.9 No Yes 9/8/2005 22,627 6.173 1.082 0.000 No 897.7 6.8 No Yes 6/1/2006 29,438 8.143 1.051 0.000 No 854.1 6.8 No Yes 11/21/2006 33,876 9.562 1.081 0.000 No 790.1 6.7 No Yes 11/21/2006 33,876 9.215 1.076 0.000 No 704.9 6.6 No Yes Level : C LPRM ID No. : 467 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.022 1.078 0.000 No 1,159.6 7.1 No Yes 7/8/2004 12,649 2.505 0.942 0.000 No 1,230.9 7.i No Yes 12/2/2004 16,446 3.502 1.053 0.000 No 1,158.0 7.1 No Yes 3/21/2005 18,262 4.032 1.109 0.000 No 1,044.2 7.0 No Yes 8/10/2006 31,236 7.147 1.086 0.000 No 961.5 6.9 No Yes 9/14/2006 32,130 7.422 1.061 0.000 No 906.2 6.8 No Yes 10/19/2006 33,029 7.660 1.071 0.000 No 846.1 6.7 No Yes 11/21/2006 33,876 7.903 1.071 0.000 No 790.0 6.7 No Yes Level : D LPRM ID No. : 483 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 119/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/23/2004 9,931 1.312 0.942 0.000 No 1,327.0 7.2 No Yes 7/8/2004 12,649 1.713 0.945 0.000 No 1,404.2 7.2 No Yes 3/21/2005 18,262 3.046 1.116 0.000 No 1,258.2 7.1 No Yes 9/14/2006 32,130 5.215 0.945 0.000 No 1,331.5 7.2 No Yes 11/2112006 33,876 5.585 0.916 0.000 No 1,453.6 7.3 No Yes String No. : 8 Serial No. : 00s10719 Cycle Installed :

9 Coordinates : 49 Type : NA300 Cumulative Core Average Exposure at BOC :

37,262 Level : A LPRM ID No. : 369 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.034 1.109 0.000 No 1,127.1 7.0 No Yes 12/12/2002 894 3.969 1.054 0.000 No 615.4 6.4 No Yes 1/11/2001 994 0.242 1.068 0.000 No 1,055.4 7.0 No Yes

4/16/2001 3,366 0.783 1.052 0.000 No 1,003.2 6.9 No Yes 7/12/2001 5,551 1.302 1.077 0.000 No 931.5 6.8 No Yes 10/25/2001 8,114 1.871 1.078 0.000 No 864.1 6.8 No Yes 12/27/2001 9,741 2.262 1.075 0.000 No 803.8 6.7 No Yes 1/31/2002 10,629 2.484 1.054 0.000 No 762.6 6.6 No Yes 517/2002 12,641 2.878 1.103 0.000 No 691.4 6.5 No Yes 9/26/2002 16,254 3.577 1.066 0.000 No 648.6 6.5 No Yes 6/12/2003 21,885 4.850 1.073 0.000 No 573.5 6.4 No Yes 11/13/2003 25,649 5.897 1.102 0.000 No 520.4 6.3 No Yes 2/16/2004 28,099 6.598 1.058 0.000 No 491.9 6.2 No Yes 6/3/2004 30,892 7.397 1.059 0.000 No 464.5 6.1 No Yes 12/2/2004 35,546 8.504 1.055 0.000 No 440.3 6.1 No Yes 6/2/2005 39,224 9.426 1.087 0.000 No 405.0 6.0 No Yes 10/13/2005 42,617 10.366 1.069 0.000 No 378.9 5.9 No Yes 8/10/2006 50,336 12.598 1.071 0.000 No 353.8 5.9 No Yes 10/19/2006 52,129 13.183 1.056 0.000 No 335.0 5.8 No Yes 11121/2006 52,976 13.414 0.986 0.000 No 339.8 5.8 No Yes Level : B LPRM ID No.: 377 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 1218/2000 126 0.032 1.063 0.000 No 1,175.9 7.1 No Yes 12/12/2002 894 4.730 1.065 0.000 No 645.2 6.5 No Yes 5/24/2001 4,358 1.109 1.057 0.000 No 1,112.5 7.0 No Yes 8/16/2001 6,465 1.731 1.067 0.000 No 1,042.6 6.9 No Yes 10/25/2001 8,114 2.180 1.073 0.000 No 971.7 6.9 No Yes 12/27/2001 9,741 2.671 1.094 0.000 No 888.2 6.8 No Yes 3/14/2002 11,683 3.221 1.099 0.000 No 808.2 6.7 No Yes 6/13/2002 13,605 3.682 1.087 0.000 No 743.5 6.6 No Yes 8/22/2002 15,409 4.124 1.082 0.000 No 687.2 6.5 No Yes 4/3/2003 20,071 5.190 1.076 0.000 No 599.7 6.4 No Yes 7/31/2003 23,003 5.926 1.065 0.000 No 563.1 6.3 No Yes 12118/2003 26,544 6.904 1.107 0.000 No 508.6 6.2 No Yes 9/16/2004 33,557 8.629 1.077 0.000 No 472.3 6.2 No Yes 12/29/2004 36,245 9.314 1.063 0.000 No 444.3 6.1 No Yes 3/21/2005 37,362 9.581 1.055 0.000 No 421.1 6.0 No Yes 10/13/2005 42,617 11.065 1.089 0.000 No 386.7 6.0 No Yes

6/1/2006 9/14/2006 11/21/2006 48,538 51,230 52,976 12.786 13.552 14.051 1.069 1.059 1.027 0.000 0.000 0.000 No No No 361.7 341.6 332.6 5.9 5.8 5.8 No No No Yes Yes Yes Level : C LPRM ID No. : 385 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.027 1.079 0.000 No 1,158.5 7.1 No Yes 12112/2002 894 4.590 1.056 0.000 No 684.7 6.5 No Yes 912012001 7,201 1.810 1.053 0.000 No 1,100.2 7.0 No Yes 11/29/2001 9,012 2.247 1.069 0.000 No 1,029.2 6.9 No Yes 1/31/2002 10,629 2.667 1.085 0.000 No 948.5 6.9 No Yes 3/14/2002 11,683 2.963 1.058 0.000 No 896.5 6.8 No Yes 5/7/2002 12,641 3.221 1.077 0.000 No 832.4 6.7 No Yes 7/1812002 14,514 3.698 1.079 0.000 No 771.5 6.6 No Yes 9/26/2002 16,254 4.154 1.067 0.000 No 723.0 6.6 No Yes 4/3/2003 20,071 5.021 1.064 0.000 No 643.5 6.5 No Yes 7/31/2003 23,003 5.633 1.069 0.000 No 602.0 6.4 No Yes 11/13/2003 25,649 6.207 1.057 0.000 No 569.5 6.3 No Yes 2216/2004 28,099 6.697 1.059 0.000 No 537.8 6.3 No Yes 9/16/2004 33,557 7.803 1.069 0.000 No 503.1 6.2 No Yes 12/2/2004 35,546 8.330 1.057 0.000 No 475.9 6.2 No Yes 3/21/2005 37,362 8.877 1.096 0.000 No 434.3 6.1 No Yes 8/11/2005 41,011 9.576 1.061 0.000 No 409.3 6.0 No Yes 12/29/2005 44,593 10.437 1.052 0.000 No 389.1 6.0 No Yes 9/14/2006 51,230 12.169 1,070 0.000 No 363.6 5.9 No Yes 11/21/2006 52,976 12.671 1.037 0.000 No 350.6 5.9 No Yes Level : D LPRM ID No. : 393 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gal's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.013 1.083 0.000 No 1,154.2 7.1 No Yes 12212/2002 894 3.268 1.078 0.000 No 1,006.3 6.9 No Yes 1/11/2001 994 0.139 1.052 0,000 No 1,097.1 7.0 No Yes 5/24/2001 4,358 0.657 0.947 0.000 No 1,158.6 7.1 No Yes 8/22/2002 15,409 2.702 1.068 0.000 No 1,084.8 7.0 No Yes 2/27/2003 19,218 3.504 1.071 0.000 No 939.6 6.8 No Yes

String No. :

Coordinates :

9 49 Serial No..

Type:

02841555 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

18,162 10 Level : A LPRM ID No. : 436 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.028 1.079 0.000 No 1,158.5 7.1 No Yes 4/3/2003 971 0.243 1.072 0.000 No 1,080.7 7.0 No Yes 3/21/2005 18,262 4.753 1.117 0.000 No 967.5 6.9 No Yes 4/28/2005 19,231 5.077 0.947 0.000 No 1,021.6 6.9 No Yes 7/7/2005 21,011 5.673 1.079 0.000 No 946.8 6.9 No Yes 9/8/2005 22,627 6.209 0.942 0.000 No 1,005.1 6.9 No Yes 10/13/2005 23,517 6.428 1.058 0.000 No 950.0 6.9 No Yes 3/23/2006 27,647 7.516 1.082 0.000 No 878.0 6.8 No Yes 4/27/2006 28,544 7.792 0.944 0.000 No 930.1 6.8 No Yes 6/1/2006 29,438 8.092 1.054 0.000 No 882.5 6.8 No Yes 11/21/2006 33,876 9.414 1.072 0.000 No 823.2 6.7 No Yes Level : B LPRM ID No. : 452 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.029 1,165 0.000 No 1,073.0 7.0 No Yes 5/8/2003 1,879 0.463 1.061 OA00 No 1,011.3 6.9 No Yes 4/22/2004 10,709 2.596 0.940 0.000 No 1,075.8 7.0 No Yes 8/5/2004 13,375 3.332 0.940 0.000 No 1,144.0 7.0 No Yes 3/21/2005 18,262 4.575 1.158 0.000 No 987.9 6.9 No Yes 7/6/2006 30,336 8.109 1.075 0.000 No 919.0 6.8 No Yes 6/12/2003 21,885 3.787 1.052 0.000 No 893.1 6.8 No Yes 10/16/2003 24,919 4.166 1.054 0.000 No 847.4 6.7 No Yes 2/16/2004 28,099 4.583 1.077 0.000 No 786.8 6.7 No Yes 9/16/2004 33,557 5.345 1.055 0.000 No 745.8 6,6 No Yes 12/2/2004 35,546 5.802 1.095 0.000 No 681.1 6.5 No Yes 1/21/2005 36,837 6.151 1.074 0.000 No 634.2 6.5 No Yes 9/8/2005 41,727 6.829 1.064 0.000 No 596.0 6.4 No Yes 12/29/2005 44,593 7.222 1.060 0.000 No 562.3 6.3 No Yes 10/19/2006 52,129 8.635 1.054 0.000 No 533.5 6.3 No Yes 11/21/2006 52,976 8.820 1.016 0.000 No 525.1 6.3 No Yes

8/10/2006 31,236 8.372 1.063 0.000 No 864.5 6.8 No Yes 9/14/2006 32,130 8.624 1.100 0.000 No 785.9 6.7 No Yes 10/19/2006 33,029 8.854 1.059 0.000 No 742.1 6.6 No Yes 11/21/2006 33,876 9.086 1.034 0.000 No 717.7 6.6 No Yes Level: C LPRM ID No. : 468 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/3/2003 971 0.159 1.058 0.000 No 1,181.5 7.1 No Yes 7/31/2003 3,903 0.652 0.948 0.000 No 1,246.3 7.1 No Yes 12/18/2003 7,444 1.381 0.947 0.000 No 1,316.0 7.2 No Yes 3/21/2005 18,262 3.949 1.120 0.000 No 1,175.0 7.1 No Yes 12129/2005 25,493 5.715 1.073 0.000 No 1,095.1 7.0 No Yes 7/6/2006 30,336 7.006 1.054 0.000 No 1,039.0 6.9 No Yes 9/14/2006 32,130 7.539 1.109 0.000 No 936.9 6.8 No Yes 11/21/2006 33,876 8.005 1.079 0.000 No 868.3 6.8 No Yes Level: D LPRM ID No. : 484 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 7/31/2003 3,903 0.409 0.941 0.000 No 1,328.4 7.2 No Yes 1/5/2004 7,911 0.917 0.941 0.000 No 1,411.7 7.3 No Yes 8/5/2004 13,375 1.721 0.935 0.000 No 1,510.0 7.3 No Yes 3121/2005 18,262 2.829 1.054 0.000 No 1,432.6 7.3 No Yes 4/28/2005 19,231 2.938 1.058 0.000 No 1,354.1 7.2 No Yes 7/7/2005 21,011 3.155 0.941 0.000 No 1,439.0 7.3 No Yes 9/8/2005 22,627 3.366 1.079 0.000 No 1,333.6 7.2 No Yes 10/13/2005 23,517 3.506 0.931 0.000 No 1,432.5 7.3 No Yes 12/29/2005 25,493 3.825 1.064 0.000 No 1,346.3 7.2 No Yes 11/21/2006 33,876 5.443 1.010 0.000 No 1,333.0 7.2 No Yes String No. : 10 Serial No.: 04s82829 Cycle Installed:

11 Coordinates : 49 Type: NA300 Cumulative Core Average Exposure at BOC:

0 Level : A LPRM ID No.: 539 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.019 1.115 0.000 No 1,121.1 7.0 No Yes

6/2/2005 1,962 0.464 1.066 0.000 No 1,051.7 7.0 No Yes 11/21/2006 15,714 3.582 0.977 0.000 No 1,076.4 7.0 No Yes Level : B LPRM ID No. : 549 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/29/2005 7,331 1.916 1.053 0.000 No 1,187.1 7.1 No Yes 11/21/2006 15,714 3.847 0.991 0.000 No 1,197.9 7.1 No Yes Level : C LPRM ID No. : 559 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.021 1.120 0.000 No 1,116.1 7.0 No Yes 11/21/2006 15,714 3.581 0.986 0.000 No 1,131.9 7.0 No Yes Level : D LPRM ID No. : 569 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.013 0.946 0.000 No 1,321.4 7.2 No Yes 4/28/2005 1,069 0.129 1.110 0.000 No 1,190.4 7.1 No Yes 6/2/2005 1,962 0.238 0.927 0.000 No 1,2842 7.2 No Yes 7/7/2005 2,849 0.344 1.058 0.000 No 1,213.8 7.1 No Yes 8/1112005 3,749 0.454 0.900 0.000 No 1,348.6 7.2 No Yes 10/13/2005 5,355 0.694 1.120 0.000 No 1,204.1 7.1 No Yes 11/17/2005 6,255 0.848 0.941 0.000 No 1,280.0 7.2 No Yes 11/21/2006 15,714 2.507 0.989 0.000 No 1,294.2 7.2 No Yes String No. : 11 Serial No. : 02S41548 Cycle Installed :

10 Coordinates : 41 Type: NA300 Cumulative Core Average Exposure at BOG :

18,162 Level : A LPRM ID No. : 437 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/912003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.026 1.067 0.000 No 1,171.5 7.1 No Yes 12/18/2003 7,444 1.946 1.063 0.000 No 1,102.1 7.0 No Yes 4/28/2005 19,231 5.312 1.125 0.000 No 979.6 6.9 No Yes 11/17/2005 24,417 6.598 0.927 0.000 No 1,057.0 7.0 No Yes 2/9/2006 26,569 7.128 1.062 0.000 No 995.0 6.9 No Yes

6/1/2006 29,438 7.892 1.061 0.000 No 937.8 6.8 No Yes 7/6/2006 30,336 8.094 1.107 0.000 No 847.1 6.7 No Yes 9/14/2006 32,130 8.488 1.083 0.000 No 782.2 6.7 No Yes 10/19/2006 33,029 8.744 1.061 0.000 No 737.3 6.6 No Yes 11/21/2006 33,876 8.980 1.001 0.000 No 736.5 6.6 No Yes Level : B LPRM ID No. : 453 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected Calcur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 7/31/2003 3,903 1.000 0.947 0.000 No 1,320.0 7.2 No Yes 7/8/2004 12,649 3.181 0.945 0.000 No 1,396.8 7.2 No Yes 12/222004 16,446 4.183 1.063 0.000 No 1,314.0 7.2 No Yes 3/21/2005 18,262 4.620 1.105 0.000 No 1,189.1 7.1 No Yes 8/11/2005 21,911 5.613 1.051 0.000 No 1,131.4 7.0 No Yes 7/6/2006 30,336 7.722 1.082 0.000 No 1,045.7 7.0 No Yes 9/14/2006 32,130 8.136 1.058 0.000 No 988.4 6.9 No Yes 11/21/2006 33,876 8.578 1.067 0.000 No 926.3 6.8 No Yes Level : C LPRM ID No. : 469 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 7/31/2003 3,903 0.625 0.945 0.000 No 1,322.8 7.2 No Yes 10/16/2003 5,819 0.973 0.941 0.000 No 1,405.7 7.2 No Yes 8/5/2004 13,375 2.494 0.942 0.000 No 1,492.0 7.3 No Yes 3/21/2005 18,262 3.793 1.199 0.000 No 1,244.4 7.1 No Yes 6/2/2005 20,124 4.151 0.948 0.000 No 1,312.6 7.2 No Yes 12/29/2005 25,493 5.339 1.058 0.000 No 1,240.7 7.1 No Yes 8/10/2006 31,236 6.757 1.056 0.000 No 1,174.9 7.1 No Yes 11/21/2006 33,876 7.448 1.024 0.000 No 1,147.3 7.0 No Yes Level : D LPRM ID No. : 485 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.009 0.919 0.000 No 1,360.2 7.2 No Yes 613/2004 11,792 1.175 0.935 0.000 No 1,454.7 7.3 No Yes 8/5/2004 13,375 1.394 0.921 0.000 No 1,580.0 7.4 No Yes 3/21/2005 18,262 2.393 1.229 0.000 No 1,285.0 7.2 No Yes

4/28/2005 19,231 2.485 0.874 0.000 No 1,470.3 7.3 No Yes 11/17/2005 24,417 3.108 1.107 0.000 No 1,328.0 7.2 No Yes 6/1/2006 11/21/2006 String No. :

Coordinates :

29,438 33,876 12 41 3.879 4.684 Serial No. :

Type :

0.927 0.992 02S41553 NA300 0.000 0.000 Cumulative No No Core Average 1,432.6 1,444.1 Cycle Installed :

Exposure at BOC :

7.3 7.3 No No 18,162 Yes Yes 10 Level : A LPRM ID No. : 438 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.030 1.053 0.000 No 1,187.1 7.1 No Yes 4/3/2003 971 0.235 1.066 0.000 No 1,113.6 7.0 No Yes 3/21/2005 18,262 4.717 1.066 0.000 No 1,044.6 7.0 No Yes 8/11/2005 21,911 6.015 1.092 0.000 No 956.6 6.9 No Yes 6/1/2006 29,438 8.280 1.052 0.000 No 909.3 6.8 No Yes 8/10/2006 31,236 8.922 1,056 0.000 No 861.1 6.8 No Yes 10/19/2006 33,029 9.436 1.105 0.000 No 779.3 6.7 No Yes 11/21/2006 33,876 9.671 1.075 OA00 No 724.9 6.6 No Yes Level : B LPRM ID No. : 454 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.030 1.292 0.000 No 967.5 6.9 No Yes 4/22/2004 10,709 2.608 0.930 0.000 No 1,040.3 6.9 No Yes 3/21/2005 18,262 4.597 1.195 0.000 No 870.6 6.8 No Yes 4/27/2006 28,544 7.731 1.075 0.000 No 809.8 6.7 No Yes 10/19/2006 33,029 9.053 1.062 0.000 No 762.5 6.6 No Yes 11/21/2006 33,876 9.289 1.025 0.000 No 743.9 6.6 No Yes Level : C LPRM ID No. : 470 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.023 1.103 0.000 No 1,133.3 7.0 No Yes 9/4/2003 4,813 0.935 0.925 0.000 No 1,225.2 7.1 No Yes 9/16/2004 14,457 3.063 0.949 0.000 No 1,291.0 7.2 No Yes 10/21/2004 15,368 3.315 1.055 0.000 No 1,223.7 7.1 No Yes 3/21/2005 18,262 4.115 1.107 0.000 No 1,105.4 7.0 No Yes

7.0 6.9 6.8 6.7 7.1 7.0 7.1 7.2 7.2 7.1 7.1 7.1 7.1 11 7.1 7.0 7.1 7.0 7.0 7.1 7.1 7.1 7.1 7.1 Level : C LPRM ID No. : 560 Beginning of Life Calibration Current :

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 6/1/2006 29,438 8/10/2006 31,236 10/19/2006 33,029 11/21/2006 33,876 6.888 1.054 7.418 1.061 7.927 1.096 8.176 1.083 0.000 No 0.000 No 0.000 No 0.000 No 1,048.8 988.5 901.9 832.8 Level : D LPRM ID No. : 486 Beginning of Life Calibration Current:

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 2/27/2003 118 0.013 1.121 0.000 No 1,115.1 9/4/2003 4,813 0.652 0.932 0.000 No 1,196.4 2/16/2004 8,999 1.242 0.939 0.000 No 1,274.2 7/8/2004 12,649 1.844 0.925 0.000 No 1,365.0 3/21/2005 18,262 3.226 1.077 0.000 No 1,267.4 3/23/2006 27,647 4.636 1.056 0.000 No 1,200.2 8/10/2006 31,236 5.318 0.946 0.000 No 1,268.7 11/21/2006 33,876 5.905 1.017 0.000 No 1,247.5 String No. : 13 Serial No. : 04s82825 Cycle Installed :

Coordinates : 41 Type: NA300 Cumulative Core Average Exposure at BOC :

Level : A LPRM ID No.: 540 Beginning of Life Calibration Current:

0 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/21/2005 0

0.000 1,000 0.000 No 1,250.0 4/28/2005 1,069 0.299 1.137 0.000 No 1,099.4 9/8/2005 4,465 1.468 0.941 0.000 No 1,168.3 10/13/2005 5,355 1.713 1.073 0.000 No 1,088.8 11/21/2006 15,714 4.853 0.994 0.000 No 1,095.4 No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes Level : B LPRM ID No. : 550 Beginning of Life Calibration Current:

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 4/28/2005 1,069 0,309 1.054 0.000 No 1,186.0 9/8/2005 4,465 1.389 0.946 0.000 No 1,253.7 9/14/2006 13,968 4.248 1.055 0.000 No 1,188.3 11/21/2006 15,714 4.729 1.006 0.000 No 1,181.2

11/21/2006 String No. :

Coordinates:

15,714 14 41 2.615 Serial No. :

Type :

1.012 02S41542 NA300 0.000 Cumulative No Core Average 1,303.4 Cycle installed :

Exposure at BOC :

7.2 No 18,162 Yes 10 Level : A LPRM ID No. : 439 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1 A00 0.000 No 1,250.0 7.1 No Yes 4/3/2003 971 0.238 1.053 0.000 No 1,187.1 7.1 No Yes 9/4/2003 4,813 1.090 1.058 0.000 No 1,122.0 7.0 No Yes 10/16/2003 5,819 1.327 0.948 0.000 No 1,183.6 7.1 No Yes 4/2212004 10,709 2.469 1.061 0.000 No 1,115.5 7.0 No Yes 7/8/2004 12,649 2.989 0.933 0.000 No 1,195.6 7.1 No Yes 10/21/2004 15,368 3.748 1.070 0.000 No 1,117.4 7.0 No Yes 4/28/2005 19,231 4.919 1.124 0.000 No 994,1 6.9 No Yes 10/13/2005 23,517 6.329 1.067 0.000 No 931.7 6.8 No Yes 3!23/2006 27,647 7.402 0.930 0.000 No 1,001.8 6.9 No Yes 4/27/2006 28,544 7.662 1.051 0.000 No 953.2 6.9 No Yes 7/6/2006 30,336 8.336 1.051 0.000 No 907.0 6.8 No Yes 11/21/2006 33,876 9.409 1.058 0.000 No 857,2 6.8 No Yes Level : B LPRM ID No. : 455 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.029 1.108 0.000 No 1,128.2 7.0 No Yes 6/12/2003 2,785 0.660 1.070 0.000 No 1,054.4 7.0 No Yes 3/21/2005 18,262 4.418 1.138 0.000 No 926.5 6.8 No Yes 1/21/2005 3/21/2005 9/8/2005 11/21/2006 0

100 4,465 15,714 0.000 1.000 0.025 1.058 1.018 0.935 4.059 1.024 0.000 0.000 0.000 0.000 No No No No 1,250.0 1,181.5 1,263.6 1,234.0 7.1 7.1 7,1 7.1 No No No No Yes Yes Yes Yes Level : D LPRM ID No. : 570 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.016 1.083 0.000 No 1,154.2 7.1 No Yes 8/11/2005 3,749 0.524 0.948 0.000 No 1,217.5 7.1 No Yes 6/1/2006 11,276 1.730 0.923 0.000 No 1,319.1 7.2 No Yes

8/10/2006 31,236 8.342 1.067 0.000 No 868.3 6.8 No Yes 11/21/2006 33,876 9.077 1.104 0.000 No 786.5 6.7 No Yes Level : C LPRM ID No. : 471 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.021 1.193 0.000 No 1,047.8 7.0 No Yes 4/312003 971 0.171 1.057 0.000 No 991.3 6.9 No Yes 10/16/2003 5,819 1.122 0.943 0.000 No 1,051.2 7.0 No Yes 1/21/2005 17,737 3.703 1.060 0.000 No 991.7 6.9 No Yes 3121/2005 18,262 3.850 1.156 0.000 No 857.9 6.8 No Yes 10/1912006 33,029 7.618 1.056 0.000 No 812.4 6.7 No Yes 11/21/2006 33,876 7.867 1.013 0.000 No 801.9 6.7 No Yes Level : D LPRM ID No. : 487 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.013 1.081 0.000 No 1,156.3 7.1 No Yes 4/312003 971 0.101 1.051 0.000 No 1,100.2 7.0 No Yes 7/8/2004 12,649 1.605 0.947 0.000 No 1,161.8 7.1 No Yes 3/21/2005 18,262 2.762 1.211 0.000 No 959.4 6.9 No Yes 4/28/2005 19,231 2.885 0.921 0.000 No 1,041.7 6.9 No Yes 11/2112006 33,876 5.390 1.064 0.000 No 979.0 6.9 No Yes String No. : 15 Serial No. : 96SO0500 Cycle Installed :

8 Coordinates: 41 Type: NA300 Cumulative Core Average Exposure at BOC :

51,228 Level : A LPRM ID No. : 15 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/17/1999 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/16/1999 48 0.016 1.064 0.000 No 1,168.0 7.1 No Yes 4/14/2000 8,776 2.464 1.050 0.000 No 1,112.4 7.0 No Yes 5/18/2000 9,611 2.696 1.030 0.000 No 1,112.0 7.0 No Yes 8/1012000 11,664 3.232 1.064 0.000 No 1,045.1 7.0 No Yes 12/8/2000 14,092 3.719 1.111 0.000 No 940.7 6.8 No Yes 1/9/2003 15,550 7.812 1.062 0.000 No 512.0 6.2 No Yes 2/15/2001 15,846 4.111 1.053 0.000 No 893.3 6.8 No Yes 3/30/2001 16,962 4.351 1.058 0.000 No 844.4 6.7 No Yes

5/24/2001 18,324 4.670 1.057 0.000 No 798.8 6.7 No Yes 8/16/2001 20,431 5.152 1.059 0.000 No 754.3 6.6 No Yes 9/20/2001 21,167 5.297 1.052 0.000 No 717.0 6.6 No Yes 12/27/2001 23,707 5.882 1.103 0.000 No 650.1 6.5 No Yes 3/14/2002 25,649 6.294 1.065 0.000 No 610.4 6.4 No Yes 5/7/2002 26,607 6.491 1.065 0.000 No 573.2 6.4 No Yes 9/26/2002 30,220 7.187 1.054 0.000 No 543.8 6.3 No Yes 6/12/2003 35,851 8.474 1.097 0.000 No 466.8 6.1 No Yes 11/13/2003 39,615 9.310 1.055 0.000 No 442.4 6.1 No Yes 4/22!2004 43,775 10.318 1.063 0.000 No 416.2 6.0 No Yes 1212/2004 49,512 11.839 1.089 0.000 No 382.2 5.9 No Yes 3/21/2005 51,328 12.375 1.051 0.000 No 363.7 5.9 No Yes 4/28/2005 52,297 12.651 0.986 0.000 No 368.8 5.9 No Yes 6/2/2005 53,190 12.938 1.065 0.000 No 346.3 5.8 No Yes 10/13/2005 56,583 14.121 1.056 0.000 No 327.9 5.8 No Yes 6/1/2006 62,504 15.904 1.080 0.000 No 303.6 5.7 No Yes 9/14/2006 65,196 16.714 1.064 0.000 No 285.4 5.7 No Yes 11/21/2006 66,942 17.191 0.960 0.000 No 297.3 5.7 No Yes Level: B LPRM ID No. : 101 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.013 1.028 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.038 1.038 0.000 No 1,250.0 7.1 No Yes 5/25/1999 970 0.243 1.057 0.000 No 1,182.6 7.1 No Yes 2/3/2000 7,038 1.855 1.055 0.000 No 1,120.9 7.0 No Yes 4/14/2000 8,776 2.304 1.080 0.000 No 1,037.9 6.9 No Yes 5/18/2000 9,611 2.520 1.048 0.000 No 1,038.0 6.9 No Yes 7/5/2000 10,747 2.812 1.103 0.000 No 941.1 6.8 No Yes 8/10/2000 11,664 3.062 1.053 0.000 No 893.7 6.8 No Yes 9/21/2000 12,742 3.344 1.054 0.000 No 847.9 6.7 No Yes 10/26/2000 13,620 3.563 1.059 0.000 No 800.7 6.7 No Yes 12/8/2000 14,092 3.678 1.122 0.000 No 713.6 6.6 No Yes 2/15/2001 15,846 4.088 1.053 0.000 No 677.7 6.5 No Yes 3/30/2001 16,962 4.357 1.070 0.000 No 633.4 6.5 No Yes 5/24/2001 18,324 4.730 1.057 0.000 No 599.2 6.4 No Yes 8/16/2001 20,431 5.329 1.059 0.000 No 565.8 6.3 No Yes 10/25/2001 22,080 5.775 1.058 0.000 No 534.8 6.3 No Yes

Level : C LPRM ID No. : 187 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.010 0.997 0.000 No 1,250.0 7.1 No Yes 5/25/1999 970 0.210 0.993 0.000 No 1,255.0 7.1 No Yes 5/18/2000 9,611 2.134 0.967 0.000 No 1,255.0 7,1 No Yes 1218/2000 14,092 3.212 1.136 0,000 No 1,104.8 7.0 No Yes 1/9/2003 15,550 7.824 1.060 0.000 No 723.3 6.6 No Yes 3/8/2001 16,387 3.729 1.046 0.000 No 1,056.2 7.0 No Yes 8116/2001 20,431 4.774 1.077 0.000 No 980.7 6.9 No Yes 11/29/2001 22,978 5.386 1.057 0.000 No 927.8 6.8 No Yes 3/14/2002 25,649 6.025 1.069 0.000 No 867.9 6.8 No Yes 6/13/2002 27,571 6.485 1.055 0.000 No 822.6 6.7 No Yes 9126/2002 30,220 7.159 1.073 0.000 No 766.7 6.6 No Yes 2/27/2003 33,184 7.898 1.127 0.000 No 641.8 6.5 No Yes 7/31/2003 36,969 8.741 1.080 0.000 No 594.2 6.4 No Yes 11113/2003 39,615 9.301 1.058 0.000 No 561.7 6.3 No Yes 4/22/2004 43,775 10.115 1.068 0.000 No 525.9 6.3 No Yes 9/16/2004 47,523 10.942 1.052 0.000 No 499.9 6.2 No Yes 12129/2004 50,211 11.720 1.073 0.000 No 465.9 6.1 No Yes 3/21/2005 51,328 12.039 1.103 0.000 No 422.4 6.0 No Yes 6/2/2005 53,190 12.431 1.082 0.000 No 390.4 6.0 No Yes 12/29/2005 58,559 13.804 1.078 0.000 No 362.1 5.9 No Yes 8110/2006 64,302 15.368 1.063 0.000 No 340.7 5.8 No Yes 11/21/2006 66,942 16.129 1.040 0.000 No 327.6 5.8 No Yes 1/31/2002 24,595 6.535 1.056 0.000 No 506.4 6.2 No Yes 5/7/2002 26,607 7.087 1.053 0.000 No 481.0 6.2 No Yes 8/22/2002 29,375 7.753 1.058 0.000 No 454.6 6.1 No Yes 2127/2003 33,184 8.665 1.125 0.000 No 404.1 6.0 No Yes 6/12/2003 35,851 9.310 1.054 0.000 No 383.4 5.9 No Yes 3/23/2004 42,997 10.996 1.052 0.000 No 364.4 5.9 No Yes 6/3/2004 44,858 11.430 1.069 0.000 No 340.9 5.8 No Yes 3/2112005 51,328 13.127 1.189 0.000 No 286.7 5.7 No Yes 10/13/2005 56,583 14.771 1.073 0.000 No 267.2 5.6 No Yes 4/27/2006 61,610 16.282 1.053 0.000 No 253.8 5.5 No Yes 10/19/2006 66,095 17.572 1.056 0.000 No 240.3 5.5 No Yes 11/21/2006 66,942 17.792 1.013 0.000 No 237.2 5.5 No Yes

Level : D LPRM ID No. : 273 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.005 0.980 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.019 1.004 0.000 No 1,250.0 7.1 No Yes 12/29/1999 6,155 0.976 0.934 0.000 No 1,338.3 7.2 No Yes 5/18/2000 9,611 1.469 0.976 0.000 No 1,338.0 7.2 No Yes 12/8/2000 14,092 2.295 1.112 0.000 No 1,203.2 7.1 No Yes 12/12/2002 14,860 5.557 1.062 0.000 No 702.5 6.6 No Yes 3/30/2001 16,962 2.758 1.065 0.000 No 1,129.8 7.0 No Yes 5/24/2001 18,324 3.015 1.073 0.000 No 1,052.9 7.0 No Yes 8/16/2001 20,431 3.387 1.084 0.000 No 971,3 6.9 No Yes 11/29/2001 22,978 3.744 1.084 0.000 No 896.1 6.8 No Yes 1/31/2002 24,595 3.998 1.055 0.000 No 849.4 6.7 No Yes 5/7/2002 26,607 4.357 1.072 0.000 No 792.3 6.7 No Yes 8/22/2002 29,375 4.982 1.062 0.000 No 746.1 6.6 No Yes 2/27/2003 33,184 5.797 1.069 0.000 No 657.2 6.5 No Yes 4/3/2003 34,037 5.889 1.061 0.000 No 619.4 6.4 No Yes 12/18/2003 40,510 6.752 1.057 0,000 No 586.0 6.4 No Yes 4/2212004 43,775 7.155 1.004 0.000 No 583.6 6.4 No Yes 3121/2005 51,328 8.750 1.228 0.000 No 477.2 6.2 No Yes 4/28/2005 52,297 8.880 1.029 0.000 No 463.7 6.1 No Yes 8/11/2005 54,977 9.257 1.094 0.000 No 436.2 6.1 No Yes 9/812005 55,693 9.362 0.945 0.000 No 461.6 6.1 No Yes 10/13/2005 56,583 9.490 1.088 0.000 No 462.0 6.1 No Yes 11/17/2005 57,483 9.625 1.147 0.000 No 403.0 6.0 No Yes 4/27/2006 61,610 10.403 0.941 0.000 No 427.0 6.1 No Yes 11/21/2006 66,942 11,481 1.056 0.000 No 404.4 6.0 No Yes String No. : 16 Serial No. : 02S41549 Cycle installed :

10 Coordinates: 41 Type : NA300 Cumulative Core Average Exposure at BOC :

18,162 Level: A LPRM ID No. : 440 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.028 1,231 0.000 No 1,015.4 6.9 No Yes 4/3/2003 971 0.244 1.084 0.000 No 936.7 6.8 No Yes 11/13/2003 6,549 1.568 1.073 0.000 No 873.0 6.8 No Yes

1/21/2005 17,737 4.670 1.059 0.000 No 824.4 6.7 No Yes 3/21/2005 18,262 4.787 1.118 0.000 No 737.4 6.6 No Yes 9/8/2005 22,627 6.253 0.920 0.000 No 801.5 6.7 No Yes 12/29/2005 25,493 6.975 1.118 0.000 No 716.9 6.6 No Yes 11121/2006 33,876 9.503 0.996 0.000 No 719.8 6.6 No Yes Level : B LPRM ID No. : 456 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.029 1.267 0.000 No 986.6 6.9 No Yes 4/3/2003 971 0.242 1.066 0.000 No 925.5 6.8 No Yes 71812004 12,649 3.126 0.933 0.000 No 992.0 6.9 No Yes 10121/2004 15,368 3.883 1.004 0.000 No 992.0 6.9 No Yes 3/21/2005 18,262 4.586 1.180 0.000 No 840.7 6.7 No Yes 8/10/2006 31,236 8.364 1.056 0.000 No 796.1 6.7 No Yes 10/19/2006 33,029 8.839 1.064 0.000 No 748.2 6.6 No Yes 11/21/2006 33,876 9.071 1.046 0.000 No 715.3 6.6 No Yes Level : C LPRM ID No. : 472 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/3/2003 971 0.168 1.082 0.000 No 1,155.3 7.1 No Yes 7/31/2003 3,903 0.662 0.941 0.000 No 1,227.7 7.1 No Yes 10/16/2003 5,819 1.027 0.943 0.000 No 1,301.9 7.2 No Yes 3/21/2005 18,262 3.969 1.089 0.000 No 1,195.5 7.1 No Yes 10/13/2005 23,517 5.189 1.065 0.000 No 1,122.5 7.0 No Yes 8/10/2006 31,236 7.275 1.054 0.000 No 1,065.0 7.0 No Yes 11/21/2006 33,876 7.998 1.026 0.000 No 1,038.0 6.9 No Yes Level : D LPRM ID No. : 488 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.011 0.943 0.000 No 1,325.6 7.2 No Yes 6/12/2003 2,785 0.283 1.059 0.000 No 1,251.7 7.1 No Yes 10116/2003 5,819 0.648 0.948 0.000 No 1,320.4 7.2 No Yes 7/8/2004 12,649 1.603 0.911 0.000 No 1,449.4 7.3 No Yes 7/7/2005 21,011 3.185 1.061 0.000 No 1,366.0 7.2 No Yes

11/17/2005 24,417 3.685 1A62 0.000 No 1,286.0 7.2 No Yes 12229/2005 25,493 3.852 0.922 0.000 No 1,394.8 7.2 No Yes 11/21/2006 33,876 5.461 1.064 0.000 No 1,310.9 7.2 No Yes String No. :

Coordinates :

17 41 Serial No. :

Type:

M5421 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

61,028 7

Level : A LPRM ID No.: 17 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 9,490 1.281 1.001 0.000 Yes 1,081,0 7.0 No Yes 8/5/1999 12,541 1.814 1.063 0.000 No 1,016.9 6.9 No Yes 11/23/1999 15,075 2.299 1.052 0.000 No 966.7 6.9 No Yes 4/14/2000 18,576 2.855 1.072 0.000 No 901.7 6.8 No Yes 5/1812000 19,411 2.984 1.010 0.000 No 902.0 6.8 No Yes 9/21/2000 22,542 3.595 1.073 0.000 No 840.6 6.7 No Yes 12/8/2000 23,892 3.776 1.076 0.000 No 781.3 6.7 No Yes 11119/2002 24,072 7.188 1.084 0.000 No 524.2 6.3 No Yes 2/15/2001 25,646 4.075 1.050 0.000 No 744.1 6.6 No Yes 7/12/2001 29,317 4.661 1.068 0.000 No 696.7 6.5 No Yes 9/20/2001 30,967 4.956 1.053 0.000 No 661.6 6.5 No Yes 12227/2001 33,507 5.481 1.076 0.000 No 614.9 6.4 No Yes 5/7/2002 36,407 6.175 1.082 0.000 No 568.3 6.3 No Yes 2127/2003 42,984 7.456 1.076 0.000 No 487.2 6.2 No Yes 5/8/2003 44,745 7.869 1.058 0.000 No 460.5 6.1 No Yes 11/13/2003 49,415 8.855 1.068 0.000 No 431.2 6.1 No Yes 4/22/2004 53,575 9.817 1.104 0.000 No 390.6 6.0 No Yes 12/29/2004 60,011 11.186 1.052 0.000 No 371.3 5.9 No Yes 4/28/2005 62,097 11.584 1.089 0.000 No 340.9 5.8 No Yes 6/212005 62,990 11.797 1.070 0.000 No 318.6 5.8 No Yes 229/2006 69,435 13.036 1.073 0.000 No 297.0 5.7 No Yes 11/21/2006 76,742 14.119 0.954 0.000 No 311.3 5.7 No Yes Level : B LPRM ID No. : 103 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 9,490 1.721 1.021 0.000 Yes 1,023.0 6.9 No Yes 7/1/1999 11,679 2.136 1.051 0.000 No 973.4 6.9 No Yes 10/14/1999 14,167 2.637 1.054 0.000 No 923.5 6.8 No Yes 12/29/1999 15,955 3.003 1.068 0.000 No 864.7 6.8 No Yes

4/14/2000 18,576 3.595 1.069 0.000 No 808.9 6.7 No Yes 5/18/2000 19,411 3.786 1.031 0.000 No 809.0 6.7 No Yes 7/5/2000 20,547 4.027 1.067 0.000 No 758.2 6.6 No Yes 9/21/2000 22,542 4.445 1.066 0.000 No 711.3 6.6 No Yes 1218/2000 23,892 4,700 1.085 0.000 No 655.5 6.5 No Yes 1/9/2003 25,350 8.528 1.050 0.000 No 478.2 6.2 No Yes 3/8/2001 26,187 5.123 1.053 0.000 No 622.5 6.4 No Yes 7/12/2001 29,317 5.724 1.079 0.000 No 577.0 6.4 No Yes 1/31/2002 34,395 6.834 1.068 0.000 No 540.2 6.3 No Yes 7/18/2002 38,280 7.715 1.076 0.000 No 502.1 6.2 No Yes 2/27/2003 42,984 8.584 1.094 0.000 No 437,1 6.1 No Yes 6/12/2003 45,651 9.161 1.057 0.000 No 413.5 6.0 No Yes 12118/2003 50,310 10.137 1.059 0.000 No 390.5 6.0 No Yes 6/3/2004 54,658 11.067 1.060 0.000 No 368.4 5.9 No Yes 9/16/2004 57,323 11.673 1.063 0.000 No 346.5 5.8 No Yes 3/21/2005 61,128 12.492 1.099 0.000 No 315.3 5.8 No Yes 4/28/2005 62,097 12.743 1.063 0.000 No 296.6 5.7 No Yes 8/11/2005 64,777 13.398 1.057 0.000 No 280.6 5.6 No Yes 11/17/2005 67,283 13.957 1.064 0.000 No 264.0 5.6 No Yes 6/1/2006 72,304 15.043 1.071 0.000 No 246.5 5.5 No Yes 11/21/2006 76,742 15.774 0.983 0.000 No 250.8 5.5 No Yes Level : C LPRM ID No. : 189 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 9,490 1.812 1.035 0.000 Yes 1,001.0 6.9 No Yes 10/14/1999 14,167 2.550 1.055 0.000 No 948.8 6.9 No Yes 5/18/2000 19,411 3.417 1.078 0.000 No 880.2 6.8 No Yes 9/21/2000 22,542 1987 1.082 0.000 No 813.5 6.7 No Yes 12/8/2000 23,892 4.276 1.115 0.000 No 729.6 6.6 No Yes 12/12/2002 24,660 7.539 1.053 0.000 No 521.7 6.3 No Yes 3/8/2001 26,187 4.682 1.062 0.000 No 687.0 6.5 No Yes 7/1212001 29,317 5.253 1.061 0.000 No 647.5 6.5 No Yes 11/29/2001 32,778 5.860 1.051 0.000 No 616.1 6.4 No Yes 3/14/2002 35,449 6.315 1.056 0.000 No 583.4 6.4 No Yes 7/18/2002 38,280 6.873 1.062 0.000 No 549.3 6.3 No Yes 2/27/2003 42,984 7,730 1.114 0.000 No 468.3 6.1 No Yes 11/13/2003 49,415 8.598 1.060 0.000 No 441.8 6.1 No Yes

6.0 6.0 5.8 5.8 5.7 5.7 5.6 5.6 7,1 7.1 7.0 6.9 6.8 6.8 6.7 6.6 6.6 6.5 6.5 6.3 6.3 6.3 6.3 6.2 6.2 11 7.1 7.0 7.1 7.0 6/1/2006 10/19/2006 11/21/2006 72,304 75,895 76,742 12.990 1.053 13.791 1.057 13.963 1.009 0.000 0.000 0.000 No No No 291.6 275.9 273.4 Level : D LPRM ID No. : 275 Beginning of Life Calibration Current:

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 9112/1996 9,490 1.484 1.019 0.000 Yes 1,197.0 5/18/2000 19,411 2.431 1.037 0.000 No 1,197.0 8/10/2000 21,464 2.635 1.061 0.000 No 1,128.2 12/8/2000 23,892 2.939 1.138 0.000 No 991.4 7/12/2001 29,317 3.479 1.075 0.000 No 922.2 1131/2002 34,395 3.969 1.070 0.000 No 861.9 7/18/2002 38,280 4.427 1.079 0.000 No 798.8 2/27/2003 42,984 5.047 1.131 0.000 No 706.3 5/8/2003 44,745 5.144 0.945 0.000 No 747.4 6/1222003 45,651 5.200 1.070 0.000 No 698.5 10/21/2004 58,234 6.382 1.066 0.000 No 655.2 3/21/2005 61,128 6.885 1.145 0.000 No 572.2 10/13/2005 66,383 7.487 1.062 0.000 No 538.8 11/17/2005 67,283 7,621 0.947 0.000 No 569.0 3/23/2006 70,513 8.121 1.051 0.000 No 541.4 7/6/2006 73,202 8.573 1.052 0.000 No 514.6 11/2112006 76,742 9.226 1.063 0.000 No 484.1 No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 7/8/2004 55,515 9.544 1.062 MOO No 416.0 10/21/2004 58,234 10.101 1.053 0.000 No 395.1 3/21/2005 61,128 10.773 1.157 0.000 No 341.4 7/7/2005 63,877 11.273 1.056 0.000 No 323.3 12/29/2005 68,359 12.172 1.053 0.000 No 307.1 String No. :

Coordinates :

18 33 Serial No. :

Type:

03s61366 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

Level : A LPRM ID No. : 541 Beginning of Life Calibration Current:

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 4/28/2005 1,069 0.346 1.120 0.000 No 1,116.1 6/212005 1,962 0.601 0.935 0,000 No 1,193,7 12/29/2005 7,331 2.099 1.066 0.000 No 1,119.8 0

1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes

String No.:

Coordinates:

19 33 Serial No.:

Type:

02S41545 NA300 Cumulative Core Average Cycle Installed:

Exposure at SOC:

18,162 10 Level : A LPRM ID No.: 441 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 119/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.030 1.136 0.000 No 1,100.4 7.0 No Yes 10116/2003 5,819 1.367 1.072 0.000 No 1,026.4 6.9 No Yes 7/7/2005 21,011 5.623 1.065 0.000 No 963.8 6.9 No Yes 8/11/2005 21,911 5.944 1.059 0.000 No 910.1 6.8 No Yes 12/29/2005 25,493 6.976 0.930 0.000 No 978.6 6.9 No Yes 4/27/2006 28,544 7.775 1.096 0.000 No 892.9 6.8 No Yes 10/19/2006 33,029 9.264 1.097 0.000 No 813.9 6.7 No Yes 11/21/2006 33,876 9.479 0.926 0.000 No 879.0 6.8 No Yes 11/21/2006 15,714 4.559 0.983 OA00 No 1,139.1 7.0 No Yes Level: 6 LPRM ID No. : 551 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.032 0.966 0.000 No 1,250.0 7.1 No Yes 12/29/2005 7,331 2.039 0.945 0.000 No 1,322.8 7.2 No Yes 11/21/2006 15,714 4.344 0.990 0.000 No 1,336.1 7.2 No Yes Level : C LPRM ID No. : 561 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 11/17/2005 6,255 1.223 0.948 0.000 No 1,319.0 7.2 No Yes 4/27/2006 10,382 2.184 0.933 0.000 No 1,413.7 7.3 No Yes 11/21/2006 15,714 3.649 1.003 0.000 No 1,409.5 7.3 No Yes Level: D LPRM ID No.. 571 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/2112005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.101 0.905 0.000 No 1,381.2 7.2 No Yes 1212912005 7,331 0.851 0.906 0.000 No 1,524.5 7.3 No Yes 9/14/2006 13,968 2.003 0.925 0.000 No 1,648.1 7.4 No Yes 11/21/2006 15,714 2.347 1.018 0.000 No 1,619.0 7.4 No Yes

9/14/2006 10/19/2006 11/21/2006 32,130 33,029 33,876 7.660 7.932 8.174 1.068 1.077 1.040 0.000 0.000 0.000 No No No 986.0 915.5 880.3 6.9 6.8 6.8 No No No Yes Yes Yes Level : D LPRM ID No. : 489 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/16/2003 5,819 0.813 0.941 0.000 No 1,328.4 7.2 No Yes 3/23/2004 9,931 1.397 0.942 0.000 No 1,410.2 7.3 No Yes 8/5/2004 13,375 1.869 0.948 0.000 No 1,488.0 7.3 No Yes 3/21/2005 18,262 3.079 1.161 0.000 No 1,281.7 7.2 No Yes 6/2/2005 20,124 3.298 0.939 0.000 No 1,364.9 7.2 No Yes 8/11/2005 21,911 3.540 0.927 0.000 No 1,472.4 7.3 No Yes 10/13/2005 23,517 3.746 1.051 0.000 No 1,400.9 7.2 No Yes 2/9/2006 26,569 4.176 1.070 0.000 No 1,309.0 7.2 No Yes 6/1/2006 29,438 4.760 0.939 0.000 No 1,394.0 7.2 No Yes 9/14/2006 32,130 5.229 1.078 0.000 No 1,293.2 7.2 No Yes Level : B LPRM ID No. : 457 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.031 1.067 0.000 No 1,171.5 7.1 No Yes 1/21/2005 17,737 4.496 1.051 0.000 No 1,114.7 7.0 No Yes 3121/2005 18,262 4.623 1.067 0.000 No 1,044.7 7.0 No Yes 11/17/2005 24,417 6.470 1.068 0.000 No 978.0 6.9 No Yes 6/1/2006 29,438 7.919 1.065 0.000 No 918.3 6.8 No Yes 8/10/2006 31,236 8.448 1.068 0.000 No 859.8 6.8 No Yes 10/19/2006 33,029 8.975 1.104 0.000 No 778.8 6.7 No Yes 11/21/2006 33,876 9.201 1.038 0.000 No 750.3 6.6 No Yes Level : C LPRM ID No. : 473 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.027 1.057 0.000 No 1,182.6 7.1 No Yes 10/16/2003 5,819 1.377 0.947 0.000 No 1,248.8 7.1 No Yes 3/21/2005 18,262 4.268 1.123 0.000 No 1,112.0 7.0 No Yes 2/9/2006 26,569 6.114 1.056 0.000 No 1,053.0 7.0 No Yes

10/19/2006 11/21/2006 String No. :

Coordinates:

33,029 33,876 20 33 5.423 5.622 Serial No. :

Type :

0.926 1A83 OOs10717 NA300 0.000 0.000 Cumulative No No Core Average 1,396.5 1,289.5 Cycle Installed :

Exposure at BOC :

7.2 7.2 No No 37,262 Yes Yes 9

Level : A LPRM ID No. : 370 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/2612000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 1218/2000 126 0.026 1.080 0.000 No 1,157.4 7.1 No Yes 1/11/2001 994 0.200 1.091 0.000 No 1,060.9 7.0 No Yes 1/31/2002 10,629 1.725 1.061 0.000 No 999.9 6.9 No Yes 7/18/2002 14,514 2.206 1.100 0.000 No 909.0 6.8 No Yes 2/27/2003 19,218 3.101 1.177 0.000 No 772.3 6.6 No Yes 4/3/2003 20,071 3.314 1.051 0.000 No 734.8 6.6 No Yes 7/31/2003 23,003 3.956 1.115 0.000 No 659.0 6.5 No Yes 11/13/2003 25,649 4.525 1.060 0.000 No 621.7 6.4 No Yes 12/18/2003 26,544 4.719 1.073 0.000 No 579.4 6.4 No Yes 2/16/2004 28,099 5.095 1.072 0.000 No 540.5 6.3 No Yes 6/3/2004 30,892 5.833 1.057 0.000 No 511.4 6.2 No Yes 718/2004 31,749 6.085 0.912 0.000 No 560.7 6.3 No Yes 9/16/2004 33,557 6.599 1.070 0.000 No 524.0 6.3 No Yes 3/21/2005 37,362 7.434 1.172 0.000 No 447.1 6.1 No Yes 6/222005 39,224 8.030 0.942 0.000 No 474.6 6.2 No Yes 7/7/2005 40,111 8.265 1.068 0.000 No 444.0 6.1 No Yes 11/17/2005 43,517 9.313 1.147 0.000 No 387.0 6.0 No Yes 4/27/2006 47,644 10.387 0.935 0.000 No 413.9 6.0 No Yes 6/1/2006 48,538 10.650 1.058 0.000 No 391.2 6.0 No Yes 8/10/2006 50,336 11.297 1.111 0.000 No 352.1 5.9 No Yes 11/21/2006 52,976 12.033 0.975 0.000 No 3612 5.9 No Yes Level : B LPRM ID No. : 378 Beginning of Life Calibration Current:

1,250A Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 11/19/2002 306 4.071 1.102 0.000 No 780.5 6.7 No Yes 1/11/2001 994 0.233 1.052 0.000 No 1,188.2 7.1 No Yes 1/9/2003 1,584 4.350 1.004 0.000 No 777.4 6.7 No Yes 3/3012001 2,996 0.706 0.950 0.000 No 1,250.8 7.1 No Yes

Level : C LPRM ID No. : 386 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.029 1.052 0.000 No 1,188.2 7.1 No Yes 11/19/2002 306 3.967 1.057 0.000 No 768.8 6.6 No Yes 3/30/2001 2,996 0.706 0.929 0.000 No 1,279.0 7.2 No Yes 11/29/2001 9,012 2.065 1.090 0.000 No 1,173.4 7.1 No Yes 1/31/2002 10,629 2.420 1.078 0.000 No 1,088.5 7.0 No Yes 3/14/2002 11,683 2.654 1.091 OA00 No 997.7 6.9 No Yes 517/2002 12,641 2.866 1.060 0.000 No 941.2 6.8 No Yes 7/18/2002 14,514 3.295 1.099 0.000 No 856.5 6.8 No Yes 9/26/2002 16,254 3.742 1.054 0.000 No 812.6 6.7 No Yes 2/27/2003 19,218 4.333 1.146 0.000 No 670.8 6.5 No Yes 5/8/2003 20,979 4.660 1.061 0.000 No 632.3 6.4 No Yes 9/4/2003 23,913 5.240 1.080 0.000 No 585.4 6.4 No Yes 12/18/2003 26,544 5.716 1.086 0.000 No 539.1 6.3 No Yes 4/2212004 29,809 6.297 1.055 0.000 No 511.0 6.2 No Yes 3121/2005 37,362 8.039 1.241 0.000 No 411.7 6.0 No Yes 2/9/2006 45,669 9.984 1.062 0.000 No 388.0 6.0 No Yes 8/10/2006 50,336 11.242 1.061 0.000 No 365.7 5.9 No Yes 11/21/2006 52,976 12.022 1.056 0.000 No 346.3 5.8 No Yes Level : D LPRM ID No. : 394 Beginning of Life Calibration Current:

1,250.0 Total Pre~Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.018 1.148 0.000 No 1,088.9 7.0 No Yes 11/29/2001 9,012 2.135 1,068 0.000 No 1,171.1 7.1 No Yes 1/31/2002 10,629 2.560 1.081 0.000 No 1,083.4 7.0 No Yes 3114/2002 11,683 2.835 1.090 0.000 No 993.9 6.9 No Yes 6113/2002 13,605 3.265 1.070 0.000 No 928.9 6.8 No Yes 8/2212002 15,409 3.659 1.080 0.000 No 860.1 6.8 No Yes 3/21/2005 37,362 8.696 0.000 0.000 No 399.0 6.0 No Yes 11/17/2005 43,517 10.556 1.054 0.000 No 379.0 5.9 No Yes 2/9/2006 45,669 11.207 1.057 0.000 No 359.0 5.9 No Yes 9/14/2006 51,230 12.814 1.068 0.000 No 336.1 5.8 No Yes 11/21/2006 52,976 13.278 1.016 0.000 No 330.8 5.8 No Yes

11/19/2002 306 3.145 1.064 0.000 No 981.8 6.9 No Yes 4/16/2001 3,366 0.559 0.939 0.000 No 1,159.6 7.1 No Yes 1/31/2002 10,629 1.710 0.932 0.000 No 1,244.2 7.1 No Yes 3/14/2002 11,683 1.918 1.066 0.000 No 1,167.2 7.1 No Yes 7/18/2002 14,514 2.603 1.054 0.000 No 1,107.4 7.0 No Yes 8122!2002 15,409 2.793 1.060 0.000 No 1,044.7 7.0 No Yes 2/27/2003 19,218 3.475 1.142 0.000 No 859.8 6.8 No Yes 6/12/2003 21,885 3.840 1.094 0.000 No 785.9 6.7 No Yes 10/16/2003 24,919 4.295 1.072 0.000 No 733.1 6.6 No Yes 12/18/2003 26,544 4.486 1.059 0.000 No 692.3 6.5 No Yes 7/8/2004 31,749 5.071 0.926 0.000 No 747.6 6.6 No Yes 10/21/2004 34,468 5.523 1.080 0.000 No 692.2 6.5 No Yes 12/2/2004 35,546 5.752 1.082 0.000 No 639.7 6.5 No Yes 3/21/2005 37,362 6.129 1.117 0.000 No 572.7 6.4 No Yes 8/11/2005 41,011 6.677 1.069 0.000 No 535.8 6.3 No Yes 9/8/2005 41,727 6.797 1.052 0.000 No 509.3 6.2 No Yes 11/17/2005 43,517 7.054 0.940 0.000 No 542.0 6.3 No Yes 4/2712006 47,644 7.703 1.073 0.000 No 505.1 6.2 No Yes 11121/2006 52,976 8.757 1.076 0.000 No 469.4 6.2 No Yes String No. : 21 Serial No. : 96800497 Cycle Installed :

8 Coordinates : 33 Type: NA300 Cumulative Core Average Exposure at BOC :

51,228 Level : A LPRM ID No. : 21 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/17/1999 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/1611999 48 0.014 1.016 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.034 1.041 0.000 No 1,250.0 7.1 No Yes 5/25/1999 970 0.190 1.052 0.000 No 1,177.0 7.1 No Yes 7/1/1999 1,879 0.352 0.999 0.000 No 1,178.2 7.1 No Yes 10126/2000 13,620 3.411 1.058 0.000 No 1,112.5 7.0 No Yes 1218/2000 14,092 3.502 1.108 0.000 No 1,004.0 6.9 No Yes 11119/2002 14,272 6.179 0.940 0.000 No 883.6 6.8 No Yes 3/30/2001 16,962 3.996 1.080 0.000 No 929.7 6.8 No Yes 1/31/2002 24,595 5.322 1.055 0.000 No 881.2 6.8 No Yes 517/2002 26,607 5.678 1.061 0.000 No 830.5 6.7 No Yes 2/27/2003 33,184 6.550 1.060 0.000 No 833.5 6.7 No Yes 5/8/2003 34,945 6.993 1.058 0.000 No 787.8 6.7 No Yes

Level : B LPRM ID No.: 107 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.013 0.967 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.035 0.996 0.000 No 1,250.0 7.1 No Yes 5/18/2000 9,611 2.500 0.988 0.000 No 1,250.0 7.1 No Yes 8/10/2000 11,664 3.079 1.016 0.000 No 1,230.3 7.1 No Yes 12/8/2000 14,092 3.777 1.148 0.000 No 1,088.9 7.0 No Yes 11/19/2002 14,272 7.992 1A61 0.000 No 738.8 6.6 No Yes 3/30/2001 16,962 4.420 1.080 0.000 No 1,008.2 6.9 No Yes 7/12/2001 19,517 5.089 1.060 0.000 No 951.1 6.9 No Yes 11/29/2001 22,978 6.013 1.055 0.000 No 901.5 6.8 No Yes 3/14/2002 25,649 6.849 1.082 0.000 No 833.2 6.7 No Yes 7/18/2002 28,480 7.458 1.063 OA00 No 783.8 6.7 No Yes 2/27/2003 33,184 8.344 1.058 0.000 No 698.3 6.5 No Yes 5/8/2003 34,945 8.765 1.052 0.000 No 663.8 6.5 No Yes 7/3112003 36,969 9.215 1.051 0.000 No 631.5 6.4 No Yes 10/16/2003 38,885 9.605 1.053 0.000 No 599.8 6.4 No Yes 2/16/2004 42,065 10.208 1.068 0.000 No 561.6 6.3 No Yes 6/3/2004 44,858 10.774 1.073 MOO No 523.4 6.3 No Yes 7/8/2004 45,715 10.949 0.948 0.000 No 552.1 6.3 No Yes 9/16/2004 47,523 11.321 1.061 0.000 No 520.3 6.3 No Yes 12/29/2004 50,211 11.789 1.056 0.000 No 492.7 6.2 No Yes 3/21/2005 51,328 11.980 1.096 0.000 No 449.6 6.1 No Yes 6/2/2005 53,190 12.613 1.051 0.000 No 427.8 6.1 No Yes 9/8/2005 55,693 13.295 1.078 0.000 No 396.8 6.0 No Yes 10/1612003 38,885 7.793 1.072 0.000 No 734.9 6.6 No Yes 3/23/2004 42,997 8.537 1.059 0.000 No 694.0 6.5 No Yes 7/8/2004 45,715 9.099 0.939 0.000 No 739.1 6.6 No Yes 3/21/2005 51,328 9.936 1203 0.000 No 614.4 6.4 No Yes 6/2/2005 53,190 10.535 1.080 0.000 No 568.8 6.3 No Yes 9/8/2005 55,693 11.228 1.062 0.000 No 535.6 6.3 No Yes 11/17/2005 57,483 11.955 1.076 0.000 No 498.0 6.2 No Yes 3/23/2006 60,713 12.932 1.061 0.000 No 469.4 6.2 No Yes 6/1/2006 62,504 13.350 1.063 0.000 No 441.6 6.1 No Yes 9/14/2006 65,196 14.124 1.060 0.000 No 416.6 6.0 No Yes 11/21/2006 66,942 14.585 0.989 0.000 No 421.2 6.0 No Yes

12/29/2005 4/27/2006 8/10/2006 11/21/2006 58,559 61,610 64,302 66,942 14.310 15.178 15.953 16.697 1.066 1.068 1.051 1.035 0.000 0.000 0.000 0.000 No No No No 372.2 348.5 331.6 -

320.4 5.9 5.9 5.8 5.8 No No No No Yes Yes Yes Yes Level : C LPRM ID No. : 193 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.009 1.012 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.029 1.028 0.000 No 1,250.0 7.1 No Yes 5/18/2000 9,611 2.175 0.964 0.000 No 1,250.0 7.1 No Yes 12/8/2000 14,092 3.371 1.101 0.000 No 1,146.0 7.0 No Yes 11/19/2002 14,272 7.592 1.081 0.000 No 713.9 6.6 No Yes 3/30/2001 16,962 4.017 1.049 0.000 No 1,092.5 7.0 No Yes 7/12/2001 19,517 4.693 1.068 0.000 No 1,022.9 6.9 No Yes 10/25/2001 22,080 5.331 1.066 0.000 No 957.8 6.9 No Yes 1/31/2002 24,595 5.986 1.075 0.000 No 891.0 6.8 No Yes 5/7/2002 26,607 6.525 1.082 0.000 No 823.4 6.7 No Yes 7/18/2002 28,480 6.980 1.067 0.000 No 771.7 6.6 No Yes 2/27/2003 33,184 7.966 1.065 0.000 No 670.3 6.5 No Yes 4/3/2003 34,037 8.112 1.053 0.000 No 636.6 6.5 No Yes 6/12/2003 35,851 8.431 1.055 0.000 No 603.4 6.4 No Yes 9/4/2003 37,879 8.802 1.082 0.000 No 573.0 6.4 No Yes 2/16/2004 42,065 9.423 1.078 0.000 No 531.5 6.3 No Yes 9/16/2004 47,523 10.337 1.094 0.000 No 485.9 6.2 No Yes 12/29/2004 50,211 10.861 1.060 0.000 No 458.4 6.1 No Yes 3/21/2005 51,328 11.076 1.116 0.000 No 410.7 6.0 No Yes 8/11/2005 54,977 11.915 1.058 0.000 No 388.2 6.0 No Yes 9/8/2005 55,693 12.073 1.051 0.000 No 369.4 5.9 No Yes 2/9/2006 59,635 13.163 1.057 0.000 No 349.0 5.9 No Yes 6/1/2006 62,504 13.865 1.060 0.000 No 329.2 5.8 No Yes 10/19/2006 66,095 14.883 1.051 0.000 No 313.3 5.7 No Yes 11/21/2006 66,942 15.145 1.015 0.000 No 308.6 5.7 No Yes Level : D LPRM ID No. : 279 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.005 0.971 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.018 0.978 0.000 No 1,250.0 7.1 No Yes

11/23/1999 5,275 0.840 0.938 0.000 No 1,332.6 7.2 No Yes 5/18/2000 9,611 1.511 0.985 0.000 No 1,333.0 7.2 No Yes 10/26/2000 13,620 2.255 0.949 0.000 No 1,404.6 7.2 No Yes 12/8/2000 14,092 2.354 1.112 0.000 No 1,263.2 7.1 No Yes 1/9/2003 15,550 5.973 1.057 0.000 No 957.8 6.9 No Yes 1/31/2002 24,595 4.166 1.071 0.000 No 1,179.4 7.1 No Yes 6/13/2002 27,571 4.890 1.099 0.000 No 1,073.2 7.0 No Yes 8/22/2002 29,375 5.382 1.060 0.000 No 1,012.4 6.9 No Yes 4/3/2003 34,037 6.107 1.079 0.000 No 887.7 6.8 No Yes 9/4/2003 37,879 6.574 1.074 0.000 No 826.5 6.7 No Yes 2/16/2004 42,065 6.966 1.055 0.000 No 783.5 6.7 No Yes 7/8/2004 45,715 7.325 0.940 0.000 No 833.5 6.7 No Yes 9/16/2004 47,523 7.543 1.078 0.000 No 773.2 6.7 No Yes 12/29/2004 50,211 7.948 1.067 0.000 No 724.6 6.6 No Yes 3/21/2005 51,328 8.130 1.159 0.000 No 625.2 6.4 No Yes 7/7/2005 54,077 8.589 1.077 0.000 No 580.5 6.4 No Yes 9/8/2005 55,693 8.895 1.057 0.000 No 549.2 6.3 No Yes 8/10/2006 64,302 10.365 1.079 0.000 No 509.0 6.2 No Yes 11/21/2006 66,942 11.000 1.108 0.000 No 459.4 6.1 No Yes String No.: 22 Serial No. : 00s10720 Cycle Installed :

9 Coordinates: 33 Type: NA300 Cumulative Core Average Exposure at BOC :

37,262 Level : A LPRM ID No. : 371 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes Level : B LPRM ID No. : 379 Beginning of Life Calibration Current.,

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/30/2001 2,996 0.790 1.114 0.000 No 1,122.1 7.0 No Yes 7/12/2001 5,551 1.387 1.053 0.000 No 1,065.6 7.0 No Yes 8/16/2001 6,465 1.608 1.055 0.000 No 1,010.1 6.9 No Yes 10/25/2001 8,114 2.086 1.094 0.000 No 923.3 6.8 No Yes 12/27/2001 9,741 2.554 1.084 0.000 No 851.7 6.7 No Yes 3/14/2002 11,683 3.064 1.087 0.000 No 783.6 6.7 No Yes 6/13/2002 13,605 3.506 1.071 0.000 No 731.6 6.6 No Yes 8/22/2002 15,409 3.880 1.071 0.000 No 683.1 6.5 No Yes

Level: C LPRM ID No. : 387 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/12/2002 894 4.306 1.064 0.000 No 719.4 6.6 No Yes 1/11/2001 994 0.251 1.052 0.000 No 1,188.2 7.1 No Yes 8/16/2001 6,465 1.558 1.072 0.000 No 1,108.4 7.0 No Yes 10/25/2001 8,114 1.988 1.065 0.000 No 1,040.8 6.9 No Yes 12/27/2001 9,741 2.386 1.054 0.000 No 987.4 6.9 No Yes 3/14/2002 11,683 2.832 1.106 0.000 No 892.8 6.8 No Yes 6/13/2002 13,605 3.279 1.083 0.000 No 824.4 6.7 No Yes 8/22/2002 15,409 3.706 1.077 0.000 No 765.4 6.6 No Yes 2/27/2003 19,218 4.551 1.079 0.000 No 666.7 6.5 No Yes 6/12/2003 21,885 5.056 1.059 0.000 No 629.6 6.4 No Yes 12/18/2003 26,544 5.982 1.056 0.000 No 596.2 6.4 No Yes 3/23/2004 29,031 6.416 1.060 0.000 No 562.4 6.3 No Yes 9/16/2004 33,557 7.313 1.058 0.000 No 531.6 6.3 No Yes 12/29/2004 36,245 8.066 1.056 0.000 No 503.4 6.2 No Yes 3/21/2005 37,362 8.378 1.217 0.000 No 413.7 6.0 No Yes 9/8/2005 41,727 9.383 1.063 0.000 No 389.1 6.0 No Yes 3/23/2006 46,747 10.610 1.059 0.000 No 367.5 5.9 No Yes 9/14/2006 51,230 11.943 1.068 0.000 No 344.1 5.8 No Yes 11/21/2006 52,976 12.438 1.047 0.000 No 328.6 5.8 No Yes Level : D LPRM ID No. : 395 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 19,218 4.675 1.099 0.000 No 621.6 6.4 No Yes 7/31/2003 23,003 5.572 1.082 0.000 No 574.5 6.4 No Yes 12/18/2003 26,544 6.391 1.061 0.000 No 541.4 6.3 No Yes 3/23/2004 29,031 6.941 1.059 0.000 No 511.3 6.2 No Yes 9/16/2004 33,557 8.034 1.066 0.000 No 479.6 6.2 No Yes 3/21/2005 37,362 9.062 1.274 0.000 No 376.5 5.9 No Yes 10/13/2005 42,617 10.699 1.056 0.000 No 356.5 5.9 No Yes 2/9/2006 45,669 11.582 1.070 0.000 No 333.0 5.8 No Yes 8/10/2006 50,336 13.047 1.061 0.000 No 313.9 5.7 No Yes 11/21/2006 52,976 13.780 1.046 0.000 No 300.1 5.7 No Yes

String No. :

Coordinates :

23 33 Serial No. :

Type:

02S41550 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

18,162 10 Level : A LPRM ID No. : 442 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.032 1.071 0.000 No 1,167.1 7.1 No Yes 1/5/2004 7,911 2.168 1.057 0.000 No 1,104.2 7.0 No Yes 7/8/2004 12,649 3.479 0.942 0.000 No 1,172.2 7.1 No Yes 12/2/2004 16,446 4.350 1.102 0.000 No 1,063.7 7.0 No Yes 1/21/2005 17,737 4.656 0.933 0.000 No 1,140.1 7.0 No Yes 3/21/2005 18,262 4.747 1.104 0.000 No 1,032.7 6.9 No Yes 4/28/2005 19,231 5.025 0.932 0.000 No 1,108.0 7.0 No Yes 7/7/2005 21,011 5.498 1.079 0.000 No 1,026.9 6.9 No Yes 10/13/2005 23,517 6.216 1.085 0.000 No 946.4 6.9 No Yes 11/17/2005 24,417 6.509 0.949 0.000 No 997.0 6.9 No Yes 12/29/2005 25,493 6.869 1.061 OA00 No 939.7 6.8 No Yes 3/23/2006 27,647 7.418 0.935 0.000 No 1,005.0 6.9 No Yes 4/27/2006 28,544 7.653 1.064 0.000 No 944.6 6.9 No Yes 8/10/2006 31,236 8.457 1.051 0.000 No 898.7 6.8 No Yes 11/19/2002 306 3.264 1.057 0.000 No 865.3 6.8 No Yes 3/30/2001 2,996 0.505 1.052 0.000 No 1,188.2 7.1 No Yes 4/16/2001 3,366 0.570 0.945 0.000 No 1,257.4 7.1 No Yes 12/27/2001 9,741 1.613 1.074 0.000 No 1,170.7 7.1 No Yes 5/7/2002 12,641 2.196 1.102 0.000 No 1,062.4 7.0 No Yes 6/13/2002 13,605 2.432 1.055 0.000 No 1,007.0 6.9 No Yes 8/22/2002 15,409 2.874 1.101 0.000 No 914.6 6.8 No Yes 2/27/2003 19,218 3.626 1.125 0.000 No 769.1 6.6 No Yes 6/12/2003 21,885 3.959 1.051 0.000 No 731.8 6.6 No Yes 12/18/2003 26,544 4.640 1.062 0.000 No 689.1 6.5 No Yes 9/16/2004 33,557 5.499 1.053 0.000 No 654.4 6.5 No Yes 12229/2004 36,245 6.112 1.051 0.000 No 622.7 6.4 No Yes 3/21/2005 37,362 6.385 1.166 0.000 No 534.0 6.3 No Yes 9/8/2005 41,727 6.999 1.075 0.000 No 496.8 6.2 No Yes 4/27/2006 47,644 7.934 1.067 0.000 No 465.6 6.1 No Yes 6/1/2006 48,538 8.093 0.941 0.000 No 494.8 6.2 No Yes 11/21/2006 52,976 9.000 1.067 0.000 No 463.7 6.1 No Yes

10/19/2006 33,029 9.035 1.084 0.000 No 829.1 6.7 No Yes 11/21/2006 33,876 9.265 0.941 0.000 No 881.1 6.8 No Yes Level : B LPRM ID No. : 458 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 11/13/2003 6,549 1.719 0.948 0.000 No 1,318.6 7.2 No Yes 3/21/2005 18,262 4.650 1.162 0.000 No 1,134.7 7.0 No Yes 8/11/2005 21,911 5.649 1.054 0.000 No 1,076.6 7.0 No Yes 9/8/2005 22,627 5.849 1.053 0.000 No 1,022.4 6.9 No Yes 10/13/2005 23,517 6.128 1.089 0.000 No 938.9 6.8 No Yes 11/17/2005 24,417 6.410 1.055 0.000 No 890.0 6.8 No Yes 12/29/2005 25,493 6.751 1.064 0.000 No 836.5 6.7 No Yes 3/23/2006 27,647 7.349 1.090 0.000 No 767.4 6.6 No Yes 6/1/2006 29,438 7.846 1.064 0.000 No 721.2 6.6 No Yes 8/10/2006 31,236 8.356 1.066 0.000 No 676.6 6.5 No Yes 10/19/2006 33,029 8.879 1.058 0.000 No 639.5 6.5 No Yes 11/21/2006 33,876 9.103 1.015 0.000 No 630.0 6.4 No Yes Level : C LPRM ID No. : 474 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.023 1.108 0.000 No 1,138.0 7.0 No Yes 1/21/2005 17,737 3.910 1.051 0.000 No 1,082.8 7.0 No Yes 3/21/2005 18,262 4.066 1.116 0.000 No 970.2 6.9 No Yes 2/9/2006 26,569 5.881 1.052 0.000 No 922.0 6.8 No Yes 11/21/2006 33,876 7.860 1.039 0.000 No 887.4 6.8 No Yes Level : D LPRM ID No. : 490 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.011 0.933 0.000 No 1,339.8 7.2 No Yes 10/16/2003 5,819 0.675 0.911 0.000 No 1,470.7 7.3 No Yes 7/8/2004 12,649 1.535 0.932 0.000 No 1,578.0 7.4 No Yes 3/21/2005 18,262 2.843 1.071 0.000 No 1,473.3 7.3 No Yes 9/8/2005 22,627 3.385 1.076 0.000 No 1,369.3 7.2 No Yes 10/13/2005 23,517 3.504 0.901 0.000 No 1,519.7 7.3 No Yes

String No. :

Coordinates :

24 33 Serial No. :

Type :

04s82831 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

0 11 Level : A LPRM ID No. : 542 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.022 1.106 0.000 No 1,130.2 7.0 No Yes 4/28/2005 1,069 0.287 1.053 0.000 No 1,073.3 7.0 No Yes 8/11/2005 3,749 0.877 0.930 0.000 No 1,154.1 7.1 No Yes 12/29/2005 7,331 1.748 1.086 0.000 No 1,062.7 7.0 No Yes 11/21/2006 15,714 3.667 0.938 0.000 No 1,133.0 7.0 No Yes Level : B LPRM ID No. : 552 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.027 1.102 0.000 No 1,134.3 7.0 No Yes 11/21/2006 15,714 3.641 0.976 0.000 No 1,162.2 7.1 No Yes Level : C LPRM ID No. : 562 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.178 1.054 0.000 No 1,186.0 7.1 No Yes 12/29/2005 7,331 1.286 0.930 0.000 No 1,275.2 7.2 No Yes 11/21/2006 15,714 3.117 1.002 0.000 No 1,272.7 7.1 No Yes Level : D LPRM ID No. : 572 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.010 0.900 0.000 No 1,388.9 7.2 No Yes 8/11/2005 3,749 0.325 1.061 0.000 No 1,309.0 7.2 No Yes 12/29/2005 7,331 0.725 0.911 0.000 No 1,436.9 7.3 No Yes 11/17/2005 24,417 3.630 1.107 0.000 No 1,373.0 7.2 No Yes 12/29/2005 25,493 3.780 0.936 0.000 No 1,466.9 7.3 No Yes 3/23/2006 27,647 4.211 1.065 0.000 No 1,377.4 7.2 No Yes 6/1/2006 29,438 4.544 0.931 0.000 No 1,479.4 7.3 No Yes 10/19/2006 33,029 5.210 1.066 0.000 No 1,387.8 7.2 No Yes 11/21/2006 33,876 5.395 1.018 0.000 No 1,363.3 7.2 No Yes

11/21/2006 String No. :

Coordinates :

15,714 25 25 2.004 Serial No. :

Type :

0.979 99s06337 NA300 0.000 Cumulative No Core Average 1,467.7 Cycle Installed :

Exposure at BOC,

7.3 No 37,262 Yes 9

Level : A LPRM ID No. : 372 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.034 1.096 0.000 No 1,140.5 7.0 No Yes 4/16/2001 3,366 0.811 1.060 0.000 No 1,076.0 7.0 No Yes 9/26/2002 16,254 3.948 1.055 0.000 No 1,019.9 6.9 No Yes 2/27/2003 19,218 4.573 1.067 0.000 No 955.8 6.9 No Yes 7/31/2003 23,003 5.683 1.055 0.000 No 906.0 6.8 No Yes 9/4/2003 23,913 5.934 1.054 0.000 No 859.6 6.8 No Yes 12/18/2003 26,544 6.719 1.070 0.000 No 803.3 6.7 No Yes 3/23/2004 29,031 7.525 1.075 0.000 No 747.3 6.6 No Yes 6/3/2004 30,892 8.181 1.118 0.000 No 668.4 6.5 No Yes 9/16/2004 33,557 8.875 1.069 0.000 No 625.3 6.4 No Yes 3/21/2005 37,362 9.685 1.078 0.000 No 580.0 6.4 No Yes 4/28/2005 38,331 9.991 1.084 0.000 No 535.1 6.3 No Yes 6/2/2005 39,224 10.235 0.915 0.000 No 584.8 6.4 No Yes 8/11/2005 41,011 10.633 1.105 0.000 No 529.2 6.3 No Yes 9/8/2005 41,727 10.801 1.068 0.000 No 495.5 6.2 No Yes 2/9/2006 45,669 11.959 1.111 0.000 No 446.0 6.1 No Yes 10/19/2006 52,129 13.702 1.096 0.000 No 406.9 6.0 No Yes 11/21/2006 52,976 13.969 0.960 0.000 No 423.9 6.0 No Yes Level : B LPRM ID No. : 380 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/12/2002 894 4.646 1.054 0.000 No 1,112.5 7.0 No Yes 7/18/2002 14,514 3.784 1.066 0.000 No 1,172.6 7.1 No Yes 5/8/2003 20,979 5.365 1.065 0.000 No 1,044.6 7.0 No Yes 9/4/2003 23,913 6.150 1.068 0.000 No 978.1 6.9 No Yes 12/18/2003 26,544 6.873 1.069 0.000 No 915.0 6.8 No Yes 4/22/2004 29,809 7.770 1.078 0.000 No 848.8 6.7 No Yes 8/5/2004 32,475 8.474 1.060 0.000 No 801.0 6.7 No Yes

Level : C LPRM ID No. : 388 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.027 1.080 0.000 No 1,157.4 7.1 No Yes 1/9/2003 1,584 4.421 1.063 0.000 No 1,100.3 7.0 No Yes 9/20/2001 7,201 1.647 0.938 0.000 No 1,233.9 7.1 No Yes 6/13/2002 13,605 3.136 1.055 0.000 No 1,169.6 7.1 No Yes 6/12/2003 21,885 4.936 1.077 0.000 No 1,021.6 6.9 No Yes 12/18/2003 26,544 5.824 1.068 0.000 No 956.6 6.9 No Yes 6/3/2004 30,892 6.701 1.076 0.000 No 889.0 6.8 No Yes 10/21/2004 34,468 7.541 1.075 0.000 No 827.0 6.7 No Yes 12/2/2004 35,546 7.848 1.056 0.000 No 783.1 6.7 No Yes 3/21/2005 37,362 8.374 1.111 0.000 No 704.9 6.6 No Yes 10/13/2005 42,617 9.360 1.058 0.000 No 666.2 6.5 No Yes 3/23/2006 46,747 10.310 1.080 0.000 No 616.9 6.4 No Yes 8/10/2006 50,336 11.223 1.066 0.000 No 578.7 6.4 No Yes 11/21/2006 52,976 11.963 1.021 0.000 No 566.8 6.3 No Yes Level : D LPRM ID No. : 396 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Goad Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.012 1.131 0.000 No 1,105.2 7.0 No Yes 12/12/2002 894 2.697 1.065 0.000 No 963.0 6.9 No Yes 2/15/2001 1,880 0.207 1.059 0.000 No 1,043.6 7.0 No Yes 3/30/2001 2,996 0.336 0.953 0.000 No 1,095.1 7.0 No Yes 9/20/2001 7,201 0.941 0.937 0.000 No 1,168.7 7.1 No Yes 5/7/2002 12,641 1.668 1.066 0.000 No 1,096.4 7.0 No Yes 8/22/2002 15,409 2205 1.069 0.000 No 1,025.6 6.9 No Yes 2/27/2003 19,218 2.906 1.060 0.000 No 908.5 6.8 No Yes 9/16/2004 33,557 8.748 1.053 0.000 No 760.7 6.6 No Yes 12/29/2004 36,245 9.456 1.081 0.000 No 703.7 6.6 No Yes 3/21/2005 37,362 9.737 1.176 0.000 No 598.4 6.4 No Yes 9/8/2005 41,727 10.858 1.055 0.000 No 567.2 6.3 No Yes 2/9/2006 45,669 11.968 1.081 0.000 No 525.0 6.3 No Yes 9/14/2006 51,230 13.365 1.058 0.000 No 496.2 6.2 No Yes 11/21/2006 52,976 13.842 1.017 0.000 No 487.9 6.2 No Yes

String No. :

Coordinates :

26 25 Serial No. :

Type :

02S41551 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

18,162 10 Level : A LPRM ID No. : 443 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.030 1.074 0.000 No 1,163.9 7.1 No Yes 3/23/2004 9,931 2.371 1.063 0.000 No 1,094.9 7.0 No Yes 10/21/2004 15,368 3.850 0.945 0.000 No 1,158.6 7.1 No Yes 3/21/2005 18,262 4.522 1.119 0.000 No 1,035.4 6.9 No Yes 6/2/2005 20,124 5.158 1.054 0.000 No 982.4 6.9 No Yes 3/23/2006 27,647 7.459 1.073 0.000 No 915.5 6.8 No Yes 6/1/2006 29,438 8.110 1.053 0.000 No 869.4 6.8 No Yes 9/14/2006 32,130 9.058 1.068 0.000 No 814.1 6.7 No Yes 11/21/2006 33,876 9.521 1.111 0.000 No 732.8 6.6 No Yes Level : B LPRM ID No. : 459 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.029 1.063 0.000 No 1,175.9 7.1 No Yes 11/13/2003 6,549 1.576 0.976 0.000 No 1,204.8 7.1 No Yes 7/8/2004 12,649 3.050 0.939 0.000 No 1,252.3 7.1 No Yes 12/2/2004 16,446 3.997 1.074 0.000 No 1,166.0 7.1 No Yes 3/21/2005 18,262 4.460 1.132 0.000 No 1,030.1 6.9 No Yes 11/17/2005 24,417 6.349 1.089 0.000 No 946.0 6.9 No Yes 2/9/2006 26,569 6.961 1.052 0.000 No 899.0 6.8 No Yes 4/27/2006 28,544 7.571 1.070 0.000 No 840.2 6.7 No Yes 9/4/2003 23,913 3.328 1.083 0.000 No 838.9 6.7 No Yes 6/3/2004 30,892 4.150 1.092 0.000 No 768.2 6.6 No Yes 12/2/2004 35,546 4.996 1.101 0.000 No 697.7 6.5 No Yes 3/21/2005 37,362 5.435 1.083 0.000 No 644.3 6.5 No Yes 4/28/2005 38,331 5.524 0.948 0.000 No 679.6 6.5 No Yes 6/2/2005 39,224 5.610 1.067 0.000 No 636.9 6.5 No Yes 12/29/2005 44,593 6.268 1.076 0.000 No 591.9 6.4 No Yes 9/14/2006 51,230 7.396 1.082 0.000 No 547.1 6.3 No Yes 10/19/2006 52,129 7.560 0.909 0.000 No 601.8 6.4 No Yes 11/21/2006 52,976 7.725 1.112 0.000 No 541.2 6.3 No Yes

7/6/2006 30,336 8.139 1.079 0.000 No 778.7 6.7 No Yes 8/10/2006 31,236 8.419 1.057 0.000 No 736.7 6.6 No Yes 10/19/2006 33,029 8.933 1.084 0.000 No 679.6 6.5 No Yes 11/21/2006 33,876 9.167 1.073 0.000 No 633.4 6.5 No Yes Level : C LPRM ID No. : 475 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/3/2003 971 0.184 1.059 0.000 No 1,180.4 7.1 No Yes 7/31/2003 3,903 0.741 0.933 0.000 No 1,265.1 7.1 No Yes 1/5/2004 7,911 1.566 0.949 0.000 No 1,333.1 7.2 No Yes 3/21/2005 18,262 3.960 1.176 0.000 No 1,133.6 7.0 No Yes 9/14/2006 32,130 7.497 1.057 0.000 No 1,072.5 7.0 No Yes 10/19/2006 33,029 7.747 1.073 0.000 No 999.5 6.9 No Yes 11/21/2006 33,876 7.996 1.071 0.000 No 933.2 6.8 No Yes Level : D LPRM ID No. : 491 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 11/13/2003 6,549 0.853 0.946 0.000 No 1,321.4 7.2 No Yes 7/8/2004 12,649 1.754 0.913 0.000 No 1,447.3 7.3 No Yes 3/21/2005 18,262 3.021 1.118 0.000 No 1,294.5 7.2 No Yes 11/21/2006 33,876 5.605 0.974 0.000 No 1,329.1 7.2 No Yes String No. : 27 Serial No. : 96SO0498 Cycle Installed :

8 Coordinates : 25 Type : NA300 Cumulative Core Average Exposure at BOC :

51,228 Level : A LPRM ID No. : 27 Beginning of Life Calibration Current :

1,179.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.014 1.057 0.000 No 1,179.0 7.1 No Yes 4/20/1999 146 0.036 1.049 0.000 No 1,123.9 7.0 No Yes 5/18/2000 9,611 2.396 1.076 0.000 No 1,044.5 7.0 No Yes 9/21/2000 12,742 3.137 1.104 0.000 No 946.1 6.9 No Yes 12/8/2000 14,092 3.393 1.088 0.000 No 869.6 6.8 No Yes 2/15/2001 15,846 3.764 1.075 0.000 No 808.9 6.7 No Yes 3/30/2001 16,962 3.985 1.088 0.000 No 743.5 6.6 No Yes 7/12/2001 19,517 4.557 1.093 0.000 No 680.3 6.5 No Yes 9/20/2001 21,167 4.886 1.083 0.000 No 628.1 6.4 No Yes

Level : B LPRM ID No. : 113 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.013 1.006 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.036 1.046 0.000 No 1,195.0 7.1 No Yes 11/23/1999 5,275 1.340 0.949 0.000 No 1,259.2 7.1 No Yes 5/18/2000 9,611 2.405 1.051 0.000 No 1,198.1 7.1 No Yes 8/10/2000 11,664 2.922 1.053 0.000 No 1,137.8 7.0 No Yes 9/21/2000 12,742 3.206 1.059 0.000 No 1,074.4 7.0 No Yes 10/26/2000 13,620 3.426 1.053 0.000 No 1,020.3 6.9 No Yes 12/8/2000 14,092 3.543 1.075 0.000 No 949.2 6.9 No Yes 11/19/2002 14,272 7.993 1.063 0.000 No 477.5 6.2 No Yes 2/15/2001 15,846 3.961 1.104 0.000 No 859.7 6.8 No Yes 3/30/2001 16,962 4.232 1.076 0.000 No 799.0 6.7 No Yes 5/24/2001 18,324 4.613 1.081 0.000 No 739.1 6.6 No Yes 7/12/2001 19,517 4.954 1.082 0.000 No 683.1 6.5 No Yes 9/20/2001 21,167 5.422 1.065 0.000 No 641.4 6.5 No Yes 10/25/2001 22,080 5.674 1.054 0.000 No 608.6 6.4 No Yes 12/27/2001 23,707 6.185 1.063 0.000 No 572.5 6.4 No Yes 3/14/2002 25,649 6.726 1.059 0.000 No 540.6 6.3 No Yes 7/18/2002 28,480 7.370 1.065 0.000 No 507.6 6.2 No Yes 2/27/2003 33,184 8.370 1.062 0.000 No 449.7 6.1 No Yes 11/29/2001 22,978 5.237 1.058 0.000 No 593.7 6.4 No Yes 3/14/2002 25,649 5.755 1.072 0.000 No 553.8 6.3 No Yes 7/18/2002 28,480 6.144 1.085 0.000 No 510.4 6.2 No Yes 4/3/2003 34,037 7.225 1.051 0.000 No 485.7 6.2 No Yes 7/31/2003 36,969 7.869 1.051 0.000 No 462.1 6.1 No Yes 12/18/2003 40,510 8.652 1.066 0.000 No 433.5 6.1 No Yes 4/22/2004 43,775 9.426 1.063 0.000 No 407.8 6.0 No Yes 3/21/2005 51,328 11.595 1.186 0.000 No 343.8 5.8 No Yes 4/28/2005 52,297 11.865 0.947 0.000 No 363.1 5.9 No Yes 6/2/2005 53,190 12.120 1.054 0.000 No 344.5 5.8 No Yes 10/13/2005 56,583 13.145 1.058 0.000 No 325.6 5.8 No Yes 12/29/2005 58,559 13.793 1.061 0.000 No 306.9 5.7 No Yes 3/23/2006 60,713 14.397 0.929 0.000 No 330.3 5.8 No Yes 6/1/2006 62,504 14.922 1.104 0.000 No 299.2 5.7 No Yes 11/21/2006 66,942 16.233 1.044 0.000 No 286.6 5.7 No Yes

11/21/2006 66,942 17.305 1.052 0.000 No 248.5 5.5 No Yes Level : C LPRM ID No. : 199 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.009 0.981 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.030 1.004 0.000 No 1,250.0 7.1 No Yes 5/18/2000 9,611 2.073 0.963 0.000 No 1,250.0 7.1 No Yes 12/8/2000 14,092 3.128 1.074 0.000 No 1,163.9 7.1 No Yes 1/9/2003 15,550 7.764 1.069 0.000 No 757.6 6.6 No Yes 3/30/2001 16,962 3.810 1.053 0.000 No 1,105.3 7.0 No Yes 8/16/2001 20,431 4.752 1.067 0.000 No 1,035.9 6.9 No Yes 11/29/2001 22,978 5.387 1.061 0.000 No 976.3 6.9 No Yes 3/14/2002 25,649 6.049 1.069 0.000 No 913.3 6.8 No Yes 7/18/2002 28,480 6.732 1.070 0.000 No 853.6 6.7 No Yes 9/26/2002 30,220 7.193 1.054 0.000 No 809.8 6.7 No Yes 5/8/2003 34,945 8.202 1.071 0.000 No 707.3 6.6 No Yes 9/4/2003 37,879 8.870 1.072 0.000 No 659.8 6.5 No Yes 12/18/2003 40,510 9.361 1.066 0.000 No 619.0 6.4 No Yes 4/22/2004 43,775 9.928 1.066 0.000 No 580.7 6.4 No Yes 9/16/2004 47,523 10.768 1.070 0.000 No 542.7 6.3 No Yes 12/29/2004 50,211 11.520 1.067 0.000 No 508.6 6.2 No Yes 3/21/2005 51,328 11.811 1.123 0.000 No 452.9 6.1 No Yes 8/11/2005 54,977 12.583 1.065 0.000 No 425.2 6.1 No Yes 3/23/2006 60,713 14.022 1.075 0.000 No 395.6 6.0 No Yes Level : D LPRM ID No. : 285 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.005 1.015 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.020 1.059 0.000 No 1,180.0 7.1 No Yes 11/23/1999 5,275 0.877 0.936 0.000 No 1,260.7 7.1 No Yes 6/1212003 35,851 8.990 1.055 0.000 No 426.2 6.1 No Yes 2/16/2004 42,065 10.394 1.081 0.000 No 394.3 6.0 No Yes 10/21/2004 48,434 12.004 1.071 0.000 No 368.1 5.9 No Yes 3/21/2005 51,328 12.736 1.192 0.000 No 308.8 5.7 No Yes 11/17/2005 57,483 14.564 1.059 0.000 No 292.0 5.7 No Yes 2/9/2006 59,635 15.244 1.061 0.000 No 275.0 5.6 No Yes 7/6/2006 63,402 16.310 1.052 0.000 No 261.4 5.6 No Yes

5/18/2000 9,611 1.508 0.995 0.000 No 1,261.0 7.1 No Yes 12/8/2000 14,092 2.345 1.138 0.000 No 1,108.1 7.0 No Yes 3/8/2001 16,387 2.772 1.049 0.000 No 1,056.3 7.0 No Yes 5/24/2001 18,324 3.173 1.106 0.000 No 955.1 6.9 No Yes 7/12/2001 19,517 3.396 1.079 0.000 No 885.2 6.8 No Yes 10/25/2001 22,080 3.825 1.081 0.000 No 818.8 6.7 No Yes 3/14/2002 25,649 4.486 1.094 0.000 No 748.5 6.6 No Yes 6/13/2002 27,571 4.962 1.061 0.000 No 705.4 6.6 No Yes 8/22/2002 29,375 5.443 1.064 0.000 No 663.0 6.5 No Yes 4/3/2003 34,037 6.275 1.087 0.000 No 609.9 6.4 No Yes 11/13/2003 39,615 7.027 1.059 0.000 No 576.0 6.4 No Yes 9/16/2004 47,523 8.017 1.055 0.000 No 545.9 6.3 No Yes 12/2/2004 49,512 8.482 1.069 0.000 No 510.7 6.2 No Yes 4/28/2005 52,297 9.023 1.112 0.000 No 459.3 6.1 No Yes 6/2/2005 53,190 9.152 0.930 0.000 No 493.8 6.2 No Yes 7/7/2005 54,077 9.286 1.107 0.000 No 446.1 6.1 No Yes 3/23/2006 60,713 10.299 1.071 0.000 No 416.5 6.0 No Yes 9/14/2006 65,196 11.065 1.065 0.000 No 391.1 6.0 No Yes 11/21/2006 66,942 11.485 0.972 0.000 No 402.4 6.0 No Yes String No. : 28 Serial No. : OOs10718 Cycle Installed :

9 Coordinates : 25 Type: NA300 Cumulative Core Average Exposure at BOC :

37,262 Level : A LPRM ID No. : 373 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.026 1.090 0.000 No 1,146.8 7.0 No Yes 11/19/2002 306 2.673 1.053 0.000 No 941.5 6.8 No Yes 1/9/2003 1,584 2.994 1.067 0.000 No 882.4 6.8 No Yes 8/16/2001 6,465 1.058 1.004 0.000 No 1,142.2 7.0 No Yes 1/31/2002 10,629 1.757 1.079 0.000 No 1,062.8 7.0 No Yes 6/13/2002 13,605 2.163 1.072 0.000 No 991.4 6.9 No Yes 2/27/2003 19,218 3.063 1.100 0.000 No 802.2 6.7 No Yes 5/8/2003 20,979 3.471 1.086 0.000 No 738.7 6.6 No Yes 7/31/2003 23,003 1903 1.076 0.000 No 686.5 6.5 No Yes 10/16/2003 24,919 4.306 1.090 0.000 No 629.8 6.4 No Yes 2/16/2004 28,099 4.961 1.076 0.000 No 585.3 6.4 No Yes 8/5/2004 32,475 6.045 1.059 0.000 No 553.0 6.3 No Yes

11/21/2006 52,976 11.867 0.999 0.000 No 393.3 6.0 No Yes Level: B LPRM ID No. : 381 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 1228/2000 126 0.030 1.141 0.000 No 1,095.5 7.0 No Yes 11/19/2002 306 4.003 1.076 0.000 No 728.1 6.6 No Yes 11/29/2001 9,012 2.133 1.053 0.000 No 1,040.4 6.9 No Yes 1/31/2002 10,629 2.557 1.080 0.000 No 963.3 6.9 No Yes 3/14/2002 11,683 2.832 1.068 0.000 No 902.0 6.8 No Yes 6/13/2002 13,605 3.262 1.080 0.000 No 835.2 6.7 No Yes 8/22/2002 15,409 3.655 1.066 0.000 No 783.5 6.7 No Yes 2/27/2003 19,218 4.355 1.098 0.000 No 663.1 6.5 No Yes 5/8/2003 20,979 4.784 1.085 0.000 No 611.2 6.4 No Yes 7/31/2003 23,003 5.257 1.067 0.000 No 573.0 6.4 No Yes 10/16/2003 24,919 5.698 1.076 0.000 No 532.5 6.3 No Yes 3/23/2004 29,031 6.594 1.074 0.000 No 495.8 6.2 No Yes 6/3/2004 30,892 6.998 1.054 0.000 No 470.4 6.2 No Yes 1/21/2005 36,837 8.509 1.064 0.000 No 442.1 6.1 No Yes 3/21/2005 37,362 8.630 1.125 0.000 No 393.0 6.0 No Yes 10/13/2005 42,617 10.193 1.079 0.000 No 364.2 5.9 No Yes 2/9/2006 45,669 11.139 1.065 0.000 No 342.0 5.8 No Yes 8/10/2006 50,336 12.482 1.053 0.000 No 324.8 5.8 No Yes 11/21/2006 52,976 13.212 1.038 0.000 No 312.9 5.7 No Yes Level : C LPRM ID No. : 389 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.029 1.139 0.000 No 1,097.5 7.0 No Yes 11/19/2002 306 3.912 1.064 0.000 No 721.1 6.6 No Yes 3/30/2001 2,996 0.705 0.930 0.000 No 1,180.1 7.1 No Yes 3/21/2005 37,362 7.236 1.105 0.000 No 500.5 6.2 No Yes 4/28/2005 38,331 7.558 1.091 0.000 No 458.7 6.1 No Yes 10/13/2005 42,617 8.820 1.071 0.000 No 428.3 6.1 No Yes 11/17/2005 43,517 9.124 0.936 0.000 No 458.0 6.1 No Yes 2/9/2006 45,669 9.756 1.085 0.000 No 422.0 6.0 No Yes 6/1/2006 48,538 10.491 1.074 0.000 No 392.9 6.0 No Yes

9/20/2001 7,201 1.620 1.051 0.000 No 1,122.8 7.0 No Yes 11/29/2001 9,012 2.062 1.058 0.000 No 1,061.2 7.0 No Yes 1/31/2002 10,629 2.416 1.095 0.000 No 969.2 6.9 No Yes 3/14/2002 11,683 2.652 1.057 0.000 No 916.9 6.8 No Yes 6/13/2002 13,605 3.086 1.121 0.000 No 817.9 6.7 No Yes 8/22/2002 15,409 3.546 1.066 0.000 No 767.3 6.6 No Yes 2/27/2003 19,218 4.280 1.115 0.000 No 646.8 6.5 No Yes 5/8/2003 20,979 4.612 1.071 0.000 No 603.9 6.4 No Yes 9/4/2003 23,913 5.199 1.062 0.000 No 568.6 6.3 No Yes 1/5/2004 27,011 5.758 1.057 0.000 No 538.0 6.3 No Yes 4/22/2004 29,809 6.228 1.051 0.000 No 511.9 6.2 No Yes 10/21/2004 34,468 7.262 1.062 0.000 No 482.0 6.2 No Yes 3/21/2005 37,362 7.985 1.182 0.000 No 407.8 6.0 No Yes 11/17/2005 43,517 9.390 1.068 0.000 No 382.0 5.9 No Yes 8/10/2006 50,336 11.190 1.060 0.000 No 360.4 5.9 No Yes 10/19/2006 52,129 11.711 1.061 0.000 No 339.7 5.8 No Yes 11/21/2006 52,976 11.968 0.977 0.000 No 347.7 5.9 No Yes Level: D LPRM ID No. : 397 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.018 1.107 0.000 No 1,129.2 7.0 No Yes 1/11/2001 994 0.156 1.077 0.000 No 1,048.4 7.0 No Yes 1/9/2003 1,584 3.381 1.052 0.000 No 868.2 6.8 No Yes 3/30/2001 2,996 0.493 0.902 0.000 No 1,162.4 7.1 No Yes 4/16/2001 3,366 0.556 0.934 0.000 No 1,244.5 7.1 No Yes 12/27/2001 9,741 1.551 1.052 0.000 No 1,183.0 7.1 No Yes 5/7/2002 12,641 2.116 1.111 0.000 No 1,064.8 7.0 No Yes 7/18/2002 14,514 2.605 1.104 0.000 No 964.5 6.9 No Yes 9/26/2002 16,254 2.936 1.056 0.000 No 913.3 6.8 No Yes 2/27/2003 19,218 3.434 1.084 0.000 No 800.9 6.7 No Yes 4/3/2003 20,071 3.529 1.051 0.000 No 762.0 6.6 No Yes 6/12/2003 21,885 3.799 1.053 0.000 No 723.7 6.6 No Yes 11/13/2003 25,649 4.343 1.080 0.000 No 670.1 6.5 No Yes 10/21/2004 34,468 5.468 1.055 0.000 No 635.2 6.5 No Yes 3/21/2005 37,362 6.078 1.205 0.000 No 527.1 6.3 No Yes 9/8/2005 41,727 6.748 1.066 0.000 No 494.5 6.2 No Yes

String No. :

Coordinates:

29 25 Serial No. :

Type:

02S41554 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

18,162 10 Level : A LPRM ID No. : 444 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.030 1.223 0.000 No 1,022.1 6.9 No Yes 4/3/2003 971 0.234 1.065 0.000 No 959.7 6.9 No Yes 6/12/2003 2,785 0.635 1.053 0.000 No 911.4 6.8 No Yes 10/16/2003 5,819 1.308 1.080 0.000 No 843.9 6.7 No Yes 1/5/2004 7,911 1.791 1.041 0.000 No 810.6 6.7 No Yes 12/29/2004 17,145 4.269 1.078 0.000 No 782.8 6.7 No Yes 6/2/2005 20,124 5.157 1.069 0.000 No 730.0 6.6 No Yes 12/29/2005 25,493 6.835 1.054 0.000 No 692.6 6.5 No Yes 9/14/2006 32,130 8.813 1.061 0.000 No 652.8 6.5 No Yes 11/21/2006 33,876 9.287 0.973 0.000 No 670.9 6.5 No Yes Level : B LPRM ID No. : 460 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.031 1.210 0.000 No 1,033.1 6.9 No Yes 6/3/2004 11,792 2.779 1.056 0.000 No 978.3 6.9 No Yes 3/21/2005 18,262 4.529 1.238 0.000 No 790.2 6.7 No Yes 4/27/2006 28,544 7.620 1.051 0.000 No 751.9 6.6 No Yes 10/19/2006 33,029 8.945 1.072 0.000 No 701.4 6.6 No Yes 11/21/2006 33,876 9.165 1.005 0.000 No 697.9 6.5 No Yes Level : C LPRM ID No. : 476 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.027 1.068 0.000 No 1,170.4 7.1 No Yes 10/16/2003 5,819 1.386 0.926 0.000 No 1,263.9 7.1 No Yes 10/13/2005 42,617 6.874 0.936 0.000 No 528.3 6.3 No Yes 11/17/2005 43,517 7.006 1.089 0.000 No 485.0 6.2 No Yes 12/29/2005 44,593 7.162 0.929 0.000 No 522.1 6.3 No Yes 9/14/2006 51,230 8.300 1.052 0.000 No 496.3 6.2 No Yes 11/21/2006 52,976 8.711 1.104 0.000 No 449.5 6.1 No Yes

7.2 7.0 6.9 6.9 6.8 6.8 6.7 6.6 7.1 7.0 7.0 7.1 7.0 6.9 7.0 6.9 7.0 7.0 7.0 7.0 9

7.1 7.0 6.7 6.9 6.9 6.8 6.7 6.6 6.5 Level : D LPRM ID No. : 492 Beginning of Life Calibration Current :

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 2/27/2003 118 0.014 1.164 0.000 No 1,073.9 2/16/2004 8,999 1.271 0.942 0.000 No 1,140.0 12/29/2004 17,145 2.747 0.946 0.000 No 1,205.1 3/21/2005 18,262 3.037 1.138 0.000 No 1,058.9 4/28/2005 19,231 3.169 1.064 0.000 No 995.2 6/2/2005 20,124 3.294 0.935 0.000 No 1,064.4 8/11/2005 21,911 3.554 1.052 0.000 No 1,011.8 9/8/2005 22,627 3.660 0.942 0.000 No 1,074.1 6/1/2006 29,438 4.817 0.932 0.000 No 1,152.5 10/19/2006 33,029 5.495 1.059 0.000 No 1,088.3 11/21/2006 33,876 5.714 0.984 0.000 No 1,106.0 String No. : 30 Serial No. : 00s10722 Cycle Installed :

Coordinates : 25 Type : NA300 Cumulative Core Average Exposure at BOC :

Level : A LPRM ID No. : 374 Beginning of Life Calibration Current :

No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 4/22/2004 10,709 2.326 0.944 0.000 No 1,338.9 3/21/2005 18,262 4.308 1.185 0.000 No 1,129.9 2/9/2006 26,569 6.268 1.083 0.000 No 1,043.0 3/23/2006 27,647 6.549 1.058 0.000 No 985.8 7/6/2006 30,336 7.297 1.091 0.000 No 903.6 8/10/2006 31,236 7.549 1.058 0.000 No 854.1 10/19/2006 33,029 8.075 1.097 0.000 No 778.5 11/21/2006 33,876 8.315 1.032 0.000 No 754.4 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 12/8/2000 126 0.031 1.121 0.000 No 1,115.1 11/19/2002 306 3.689 1.068 0.000 No 796.2 1/31/2002 10,629 2.113 1.072 0.000 No 1,040.2 3/14/2002 11,683 2.336 1.060 0.000 No 981.3 6/13/2002 13,605 2.720 1.052 0.000 No 932.8 8/22/2002 15,409 3.122 1.097 0.000 No 850.3 2/27/2003 19,218 4.010 1.102 0.000 No 722.5 5/8/2003 20,979 4.459 1.100 0.000 No 656.8 37,262 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Good Value Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Level : C LPRM ID No. : 390 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gal's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 6/1/2006 11/21/2006 48,538 52,976 12.057 13.498 1.054 1.086 0.000 0.000 No No 339.7 312.8 5.8 5.7 No No Level : B LPRM ID No. : 382 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No 12/8/2000 126 0.030 1.087 0.000 No 1,150.0 7.0 No 1/9/2003 1,584 4.448 1.065 0.000 No 750.8 6.6 No 4/16/2001 3,366 0.774 0.946 0.000 No 1,215.6 7.1 No 10/25/2001 8,114 1.850 1.082 0.000 No 1,123.5 7.0 No 1/31/2002 10,629 2.495 1.092 0.000 No 1,028.8 6.9 No 5/7/2002 12,641 2.992 1.127 0.000 No 912.9 6.8 No 7/18/2002 14,514 3.434 1.076 0.000 No 848.4 6.7 No 9/26/2002 16,254 3.887 1.061 0.000 No 799.6 6.7 No 2/27/2003 19,218 4.520 1.089 0.000 No 689.5 6.5 No 5/8/2003 20,979 4.968 1.057 0.000 No 652.3 6.5 No 7/31/2003 23,003 5.467 1.085 0.000 No 601.2 6.4 No 10/16/2003 24,919 5.974 1.075 0.000 No 559.2 6.3 No 1/5/2004 27,011 6.549 1.058 0.000 No 528.6 6.3 No 4/22/2004 29,809 7.218 1.057 0.000 No 500.1 6.2 No 9/16/2004 33,557 8.219 1.094 0.000 No 457.1 6.1 No 12/29/2004 36,245 8.882 1.058 0.000 No 432.0 6.1 No 3/21/2005 37,362 9.176 1.184 0.000 No 364.9 5.9 No 12/29/2005 44,593 11.318 1.053 0.000 No 346.5 5.8 No 7/6/2006 49,436 12.675 1.056 0.000 No 328.2 5.8 No 10/19/2006 52,129 13.456 1.051 0.000 No 312.2 5.7 No 7/31/2003 23,003 4.946 1.070 0.000 No 613.8 6.4 No 10/16/2003 24,919 5.466 1.110 0.000 No 553.0 6.3 No 2/16/2004 28,099 6.395 1.087 0.000 No 508.7 6.2 No 6/3/2004 30,892 7.205 1.068 0.000 No 476.4 6.2 No 9/16/2004 33,557 7.982 1.053 0.000 No 452.4 6.1 No 3/21/2005 37,362 8.789 1.106 0.000 No 409.0 6.0 No 9/8/2005 41,727 10.115 1.075 0.000 No 380.5 5.9 No 11/17/2005 43,517 10.677 1.064 0.000 No 358.0 5.9 No

10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.026 1.075 0.000 No 1,162.8 7.1 No Yes 11/19/2002 306 3.811 1.064 0.000 No 761.5 6.6 No Yes 10/25/2001 8,114 1.711 1.074 0.000 No 1,082.7 7.0 No Yes 12/27/2001 9,741 2.052 1.056 0.000 No 1,025.3 6.9 No Yes 3/14/2002 11,683 2.449 1.093 0.000 No 938.0 6.8 No Yes 5/7/2002 12,641 2.657 1.075 0.000 No 872.6 6.8 No Yes 7/18/2002 14,514 3.111 1.077 0.000 No 810.2 6.7 No Yes 2/27/2003 19,218 4.214 1.138 0.000 No 669.1 6.5 No Yes 5/8/2003 20,979 4.543 1.054 0.000 No 634.8 6.5 No Yes 9/4/2003 23,913 5.080 1.058 0.000 No 600.0 6.4 No Yes 12/18/2003 26,544 5.662 1.068 0.000 No 561.8 6.3 No Yes 2/16/2004 28,099 6.027 1.059 0.000 No 530.5 6.3 No Yes 8/5/2004 32,475 6.928 1.069 0.000 No 496.0 6.2 No Yes 12/2/2004 35,546 7.749 1.070 0.000 No 463.6 6.1 No Yes 3/21/2005 37,362 8.274 1.183 0.000 No 391.8 6.0 No Yes 10/13/2005 42,617 9.401 1.057 0.000 No 370.7 5.9 No Yes 7/6/2006 49,436 11.136 1.062 0.000 No 349.1 5.9 No Yes 11/21/2006 52,976 12.164 1.059 0.000 No 329.6 5.8 No Yes Level : D LPRM ID No. : 398 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.013 1.103 0.000 No 1,133.3 7.0 No Yes 11/19/2002 306 2.583 1.085 0.000 No 1,055.1 7.0 No Yes 1/9/2003 1,584 2.873 1.057 0.000 No 998.2 6.9 No Yes 4/16/2001 3,366 0.418 0.932 0.000 No 1,216.0 7.1 No Yes 3/14/2002 11,683 1.532 0.940 0.000 No 1,293.6 7.2 No Yes 5/7/2002 12,641 1.668 1.063 0.000 No 1,216.9 7.1 No Yes 7/18/2002 14,514 2.044 1.063 0.000 No 1,144.8 7.0 No Yes 2/27/2003 19,218 2.927 1.078 0.000 No 926.0 6.8 No Yes 6/12/2003 21,885 3.240 1.082 0.000 No 855.8 6.8 No Yes 12/18/2003 26,544 3.870 1.065 0.000 No 803.6 6.7 No Yes 4/22/2004 29,809 4.357 1.057 0.000 No 760.2 6.6 No Yes 10/21/2004 34,468 5.216 1.096 0.000 No 693.6 6.5 No Yes 12/29/2004 36,245 5.688 1.051 0.000 No 660.0 6.5 No Yes 3/21/2005 37,362 5.999 1.157 0.000 No 570.4 6.3 No Yes

String No. :

Coordinates :

31 25 Serial No. :

Type :

04s82828 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

0 11 Level : A LPRM ID No. : 543 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.286 1.125 0.000 No 1,111.1 7.0 No Yes 7/7/2005 2,849 0.709 0.949 0.000 No 1,170.8 7.1 No Yes 9/8/2005 4,465 1.056 1.080 0.000 No 1,084.1 7.0 No Yes 3/23/2006 9,485 2.196 0.920 0.000 No 1,178.4 7.1 No Yes 6/1/2006 11,276 2.552 1.083 0.000 No 1,088.1 7.0 No Yes 11/21/2006 15,714 3.414 1.009 0.000 No 1,078.4 7.0 No Yes Level : B LPRM ID No. : 553 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/19/2006 14,867 3.305 1.074 0.000 No 1,163.9 7.1 No Yes 11/21/2006 15,714 3.488 0.968 0.000 No 1,202.3 7.1 No Yes Level : C LPRM ID No. : 563 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 7/7/2005 2,849 0.474 1.052 0.000 No 1,188.2 7.1 No Yes 3/23/2006 9,485 1.746 0.940 0.000 No 1,264.1 7.1 No Yes 11/21/2006 15,714 3.121 1.031 0.000 No 1,226.0 7.1 No Yes Level : D LPRM ID No. : 573 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.010 0.881 0.000 No 1,418.8 7.3 No Yes 4/28/2005 1,069 0.089 0.932 0.000 No 1,522.4 7.3 No Yes 8/11/2005 3,749 0.338 1.077 0.000 No 1,413.5 7.3 No Yes 9/8/2005 4,465 0.415 0.898 0.000 No 1,574.1 7.4 No Yes 8/11/2005 41,011 6.446 1.079 0.000 No 528.7 6.3 No Yes 12/29/2005 44,593 6.956 0.947 0.000 No 558.3 6.3 No Yes 3/23/2006 46,747 7.377 1.070 0.000 No 521.7 6.3 No Yes 11/21/2006 52,976 8.617 1.041 0.000 No 501.2 6.2 No Yes

10/13/2005 5,355 0.520 1.073 0.000 No 1,467.0 7.3 No Yes 6/1/2006 11,276 1.337 0.917 0.000 No 1,599.8 7.4 No Yes 7/6/2006 12,174 1.485 1.073 0.000 No 1,490.9 7.3 No Yes 11/21/2006 String No. :

Coordinates:

15,714 32 17 2.091 Serial No. :

Type:

0.954 04s82832 NA300 0.000 Cumulative No Core Average 1,562.8 Cycle Installed :

Exposure at BOC :

7.4 No 0

Yes 11 Level : A LPRM ID No. : 544 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cat Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/29/2005 7,331 1.733 1.075 0.000 No 1,162.8 7.1 No Yes 11/21/2006 15,714 3.555 0.966 0.000 No 1,203.7 7.1 No Yes Level : B LPRM ID No. : 554 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.278 1.062 0.000 No 1,177.0 7.1 No Yes 11/21/2006 15,714 3.664 1.000 0.000 No 1,177.0 7.1 No Yes Level : C LPRM ID No. : 564 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.203 1.054 0.000 No 1,186.0 7.1 No Yes 12/29/2005 7,331 1.545 0.946 0.000 No 1,253.7 7.1 No Yes 11/21/2006 15,714 3.394 1.036 0.000 No 1,210.1 7.1 No Yes Level : D LPRM ID No. : 574 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.011 0.890 0.000 No 1,404.5 7.2 No Yes 6/2/2005 1,962 0.195 1.071 0.000 No 1,311.4 7.2 No Yes 7/7/2005 2,849 0.289 0.927 0.000 No 1,414.7 7.3 No Yes 11/17/2005 6,255 0.751 1.062 0.000 No 1,332.0 7.2 No Yes 12/29/2005 7,331 0.915 0.893 0.000 No 1,491.6 7.3 No Yes 4/27/2006 10,382 1.394 1.051 0.000 No 1,419.2 7.3 No Yes 6/1/2006 11,276 1.532 0.915 0.000 No 1,551.1 7.3 No Yes 11/21/2006 15,714 2.297 1.058 0.000 No 1,466.0 7.3 No Yes

String No. :

Coordinates :

33 17 Serial No.,

Type :

02S41552 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

18,162 10 Level : A LPRM ID No., 445 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.029 1.087 0.000 No 1,150.0 7.0 No Yes 9/4/2003 4,813 1.039 1.059 0.000 No 1,085.9 7.0 No Yes 1/5/2004 7,911 1.764 0.915 0.000 No 1,186.8 7.1 No Yes 2/16/2004 8,999 2.104 1.089 0.000 No 1,089.8 7.0 No Yes 3/21/2005 18,262 4.846 1.122 0.000 No 971.3 6.9 No Yes 8/11/2005 21,911 6.052 1.056 0.000 No 919.8 6.8 No Yes 9/14/2006 32,130 9.077 1.069 0.000 No 860.4 6.8 No Yes 10/19/2006 33,029 9.340 0.947 0.000 No 908.6 6.8 No Yes 11/21/2006 33,876 9.586 1.039 0.000 No 874.5 6.8 No Yes Level: B LPRM ID No. : 461 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.029 1.084 0.000 No 1,153.1 7.1 No Yes 11/13/2003 6,549 1.788 1.054 O.OOo No 1,094.1 7.0 No Yes 12/29/2004 17,145 4.638 1.052 0.000 No 1,040.0 6.9 No Yes 3/21/2005 18,262 4.921 1.154 0.000 No 901.2 6.8 No Yes 6/1/2006 29,438 8.208 1.075 0.000 No 838.3 6.7 No Yes 7/6/2006 30,336 8.454 1.091 0.000 No 768.4 6.6 No Yes 8/10/2006 31,236 8.698 1.065 0.000 No 721.5 6.6 No Yes 10/19/2006 33,029 9.189 1.084 0.000 No 665.6 6.5 No Yes 11/21/2006 33,876 9.428 1.040 0.000 No 640.0 6.5 No Yes Level : C LPRM ID No. : 477 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 7/31/2003 3,903 0.772 0.921 0.000 No 1,369.0 7.2 No Yes 2/16/2004 8,999 1.828 0.942 0.000 No 1,453.3 7.3 No Yes 1/21/2005 17,737 3.999 1.014 0.000 No 1,433.2 7.3 No Yes Level. D LPRM ID No. : 493 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good

String No. :

Coordinates:

34 17 Serial No..

Type :

OOs10716 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

51,228 8

Level : A LPRM ID No. : 375 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.025 1.106 0.000 No 1,130.2 7.0 No Yes 11/19/2002 306 3.370 1.071 0.000 No 807.8 6.7 No Yes 1/11/2001 994 0.189 1.060 0.000 No 1,066.2 7.0 No Yes 1/9/2003 1,584 3.673 1.063 0.000 No 759.9 6.6 No Yes 5/24/2001 4,358 0.747 0.933 0.000 No 1,142.8 7.0 No Yes 11/29/2001 9,012 1.546 1.055 0.000 No 1,083.2 7.0 No Yes 1/31/2002 10,629 1.856 1.057 0.000 No 1,024.8 6.9 No Yes 6/13/2002 13,605 2.429 1.073 0.000 No 955.1 6.9 No Yes 8/22/2002 15,409 2.779 1.104 0.000 No 865.1 6.8 No Yes 2/27/2003 19,218 3.738 1.084 0.000 No 701.0 6.6 No Yes 5/8/2003 20,979 4.146 1.079 0.000 No 649.7 6.5 No Yes 9/4/2003 23,913 4.786 1.055 0.000 No 615.8 6.4 No Yes 10/16/2003 24,919 5.034 1.052 0.000 No 585.4 6.4 No Yes 2/16/2004 28,099 5.802 1.096 0.000 No 534.1 6.3 No Yes 4/22/2004 29,809 6.239 1.052 0.000 No 507.7 6.2 No Yes 3/21/2005 37,362 8.173 1.130 0.000 No 449.3 6.1 No Yes 4/28/2005 38,331 8.501 1.098 0.000 No 409.2 6.0 No Yes 7/7/2005 40,111 9.122 1.053 0.000 No 388.6 6.0 No Yes 9/8/2005 41,727 9.696 0.942 0.000 No 412.5 6.0 No Yes 10/13/2005 42,617 9.939 1.088 0.000 No 379.2 5.9 No Yes Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.011 0.930 0.000 No 1,344.1 7.2 No Yes 11/13/2003 6,549 0.736 0.947 0.000 No 1,419.3 7.3 No Yes 1/5/2004 7,911 0.904 1.069 0.000 No 1,327.7 7.2 No Yes 2/16/2004 8,999 1.052 0.907 0.000 No 1,463.8 7.3 No Yes 3/21/2005 18,262 2.897 1.055 0.000 No 1,387.5 7.2 No Yes 9/8/2005 22,627 3.465 1.075 0.000 No 1,290.7 7.2 No Yes 11/17/2005 24,417 3.752 0.937 0.000 No 1,377.0 7.2 No Yes 10/19/2006 33,029 5.347 1.053 0.000 No 1,307.7 7.2 No Yes 11/21/2006 33,876 5.545 0.997 0.000 No 1,311.6 7.2 No Yes

4/27/2006 8/10/2006 11/21/2006 61,610 64,302 66,942 11.302 12.305 13.071 1.090 1.054 1.048 0.000 0.000 0.000 No No No 347.8 330.0 314.9 5.9 5.8 5.8 No No No Yes Yes Yes Level : B LPRM ID No. : 383 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 1218/2000 126 0.027 1.113 OA00 No 1,123.1 7.0 No Yes 11/19/2002 306 4.023 1.057 0.000 No 761.3 6.6 No Yes 12/27/2001 9,741 2.181 1.071 0.000 No 1,048.6 7.0 No Yes 1/31/2002 10,629 2.407 1.051 0.000 No 997.8 6.9 No Yes 3/14/2002 11,683 2.672 1.066 0.000 No 936.0 6.8 No Yes 6/13/2002 13,605 3.144 1.080 0.000 No 866.6 6.8 No Yes 8/22/2002 15,409 3.560 1.077 0.000 No 804.7 6.7 No Yes 2/27/2003 19,218 4.423 1.095 0.000 No 695.2 6.5 No Yes 4/3/2003 20,071 4.630 1.059 0.000 No 656.5 6.5 No Yes 6/12/2003 21,885 5.063 1.066 0.000 No 615.9 6.4 No Yes 9/4/2003 23,913 5.547 1.053 0.000 No 584.9 6.4 No Yes 12/18/2003 26,544 6.189 1.068 0.000 No 547.6 6.3 No Yes 4/22/2004 29,809 6.942 1.072 0.000 No 510.8 6.2 No Yes 9/16/2004 33,557 7.899 1.074 0.000 No 475.6 6.2 No Yes 1/21/2005 36,837 8.693 1.053 0.000 No 451.7 6.1 No Yes 3/21/2005 37,362 8.836 1.186 0.000 No 380.9 5.9 No Yes 10/13/2005 42,617 10.457 1.081 0.000 No 352.3 5.9 No Yes 3/23/2006 60,713 11.606 1.051 0.000 No 335.2 5.8 No Yes 8/10/2006 64,302 12.702 1.063 0.000 No 315.4 5.8 No Yes 10/19/2006 66,095 13.216 1.052 0.000 No 299.8 5.7 No Yes 11/21/2006 66,942 13.450 1.018 0.000 No 294.5 5.7 No Yes Level : C LPRM ID No. : 391 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.025 1.133 0.000 No 1,103.3 7.0 No Yes 11/19/2002 306 3.733 1.051 0.000 No 815.8 6.7 No Yes 1/11/2001 994 0.205 1.054 0.000 No 1,046.7 7.0 No Yes 3/30/2001 2,996 0.622 0.887 0.000 No 1,180.1 7.1 No Yes 12/27/2001 9,741 2.033 1.059 0.000 No 1,114.3 7.0 No Yes

Level : D LPRM ID No. : 399 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.014 1.109 0.000 No 1,127.1 7.0 No Yes 11/19/2002 306 2.587 1.061 0.000 No 935.0 6.8 No Yes 1/9/2003 1,584 2.877 1.055 0.000 No 886.3 6.8 No Yes 3/30/2001 2,996 0.385 0.944 0.000 No 1,194.0 7.1 No Yes 1/31/2002 10,629 1.420 1.060 0.000 No 1,126.4 7.0 No Yes 6/13/2002 13,605 1.862 1.067 0.000 No 1,055.7 7.0 No Yes 8/22/2002 15,409 2.218 1.062 0.000 No 994.1 6.9 No Yes 9/26/2002 16,254 2.378 1.066 0.000 No 932.5 6.8 No Yes 4/3/2003 20,071 3.018 1.087 0.000 No 815.3 6.7 No Yes 9/4/2003 23,913 3.527 1.058 0.000 No 770.6 6.6 No Yes 1/5/2004 27,011 3.969 1.057 0.000 No 729.1 6.6 No Yes 9/16/2004 33,557 4.975 1.071 0.000 No 680.7 6.5 No Yes 12/29/2004 36,245 5.626 1.082 0.000 No 629.1 6.4 No Yes 1/21/2005 36,837 5.790 1.058 0.000 No 594.7 6.4 No Yes 3/21/2005 37,362 5.921 1.117 0.000 No 532.4 6.3 No Yes 4/28/2005 38,331 6.035 0.947 0.000 No 562.2 6.3 No Yes 9/8/2005 41,727 6.488 1.082 0.000 No 519.6 6.3 No Yes 3/14/2002 11,683 2.436 1.090 0.000 No 1,022.3 6.9 No Yes 6/13/2002 13,605 2.857 1.084 0.000 No 943.1 6.8 No Yes 8/22/2002 15,409 3.274 1.100 0.000 No 857.4 6.8 No Yes 2/27/2003 19,218 4.140 1.097 0.000 No 743.6 6.6 No Yes 4/3/2003 20,071 4.294 1.055 0.000 No 704.9 6.6 No Yes 6/12/2003 21,885 4.637 1.051 0.000 No 670.7 6.5 No Yes 9/4/2003 23,913 5.027 1.062 0.000 No 631.5 6.4 No Yes 2/16/2004 28,099 5.932 1.071 0.000 No 589.6 6.4 No Yes 4/22/2004 29,809 6.254 1.055 0.000 No 558.9 6.3 No Yes 9/16/2004 33,557 7.062 1.060 0.000 No 527.3 6.3 No Yes 12/2/2004 35,546 7.571 1.056 0.000 No 499.3 6.2 No Yes 3/21/2005 37,362 8.062 1.226 0.000 No 407.3 6.0 No Yes 10/13/2005 42,617 9.259 1.073 0.000 No 379.6 5.9 No Yes 3/23/2006 60,713 10.254 1.058 0.000 No 358.8 5.9 No Yes 9/14/2006 65,196 11.558 1.080 0.000 No 332.2 5.8 No Yes 11/21/2006 66,942 12.056 1.030 0.000 No 322.5 5.8 No Yes

8 Good Value Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Level : B LPRM ID No. : 121 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good String No. :

Coordinates :

35 17 Serial No. :

Type :

96800496 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

51,228 Level : A LPRM ID No. : 35 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

9/17/1999 0

0.000 1.000 0.000 No 1,250.0 7.1 No 4/16/1999 48 0.014 0.952 0.000 No 1,316.0 7.2 No 5/25/1999 970 0.227 1.046 0.000 No 1,258.1 7.1 No 5/18/2000 9,611 2.518 1.022 0.000 No 1,258.0 7.1 No 9/21/2000 12,742 3.329 1.090 0.000 No 1,154.2 7.1 No 12/8/2000 14,092 3.643 1.094 0.000 No 1,055.1 7.0 No 7/12/2001 19,517 4.712 1.071 0.000 No 985.1 6.9 No 3/14/2002 25,649 5.976 1.075 0.000 No 916.4 6.8 No 9/26/2002 30,220 6.812 1.064 0.000 No 861.3 6.8 No 2/27/2003 33,184 7.486 1.159 0.000 No 743.1 6.6 No 6/12/2003 35,851 8.104 1.095 0.000 No 678.6 6.5 No 10/16/2003 38,885 8.812 1.113 0.000 No 609.7 6.4 No 2/16/2004 42,065 9.602 0.922 0.000 No 661.3 6.5 No 3/23/2004 42,997 9.835 1.145 0.000 No 577.6 6.4 No 6/3/2004 44,858 10.326 1.098 0.000 No 526.0 6.3 No 12/2/2004 49,512 11.606 1.073 0.000 No 490.2 6.2 No 1/21/2005 50,803 11.987 0.941 0.000 No 521.0 6.3 No 3/21/2005 51,328 12.098 1.070 0.000 No 486.9 6.2 No 6/2/2005 53,190 12.658 1.088 0.000 No 447.5 6.1 No 8/11/2005 54,977 13.290 1.054 0.000 No 424.6 6.1 No 12/29/2005 58,559 14.335 1.051 0.000 No 404.0 6.0 No 4/27/2006 61,610 15.257 1.068 0.000 No 378.3 5.9 No 7/6/2006 63,402 15.894 1.101 0.000 No 343.6 5.8 No 9/14/2006 65,196 16.446 1.051 0.000 No 326.9 5.8 No 10/19/2006 66,095 16.737 0.945 0.000 No 345.9 5.8 No 11/21/2006 66,942 16.947 0.961 0.000 No 360.0 5.9 No 11/17/2005 43,517 6.725 0.886 0.000 No 586.0 6.4 No Yes 12/29/2005 44,593 6.870 1.150 0.000 No 509.6 6.2 No Yes 10/19/2006 66,095 8.333 1.058 0.000 No 481.6 6.2 No Yes 11/21/2006 66,942 8.542 0.970 0.000 No 496.5 6.2 No Yes

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.012 1.019 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.036 1.047 0.000 No 1,194.0 7.1 No Yes 7/1/1999 1,879 0.443 0.989 0.000 No 1,194.0 7.1 No Yes 5/18/2000 9,611 2.418 0.967 0.000 No 1,194.0 7.1 No Yes 12/8/2000 14,092 3.630 1.173 0.000 No 1,017.9 6.9 No Yes 12/12/2002 14,860 7.933 1.052 0.000 No 642.5 6.5 No Yes 7/12/2001 19,517 4.881 1.070 0.000 No 951.3 6.9 No Yes 10/25/2001 22,080 5.528 1.081 0.000 No 880.0 6.8 No Yes 12/27/2001 23,707 5.989 1.061 0.000 No 829.4 6.7 No Yes 5/7/2002 26,607 6.752 1.066 0.000 No 778.1 6.7 No Yes 7/18/2002 28,480 7.159 1.057 0.000 No 736.1 6.6 No Yes 9/26/2002 30,220 7.542 1.089 0.000 No 676.0 6.5 No Yes 2/27/2003 33,184 8.174 1.129 0.000 No 569.1 6.3 No Yes 4/3/2003 34,037 8.399 1.064 0.000 No 534.9 6.3 No Yes 6/12/2003 35,851 8.864 1.059 0.000 No 505.1 6.2 No Yes 9/4/2003 37,879 9.374 1.072 0.000 No 471.2 6.2 No Yes 1/5/2004 40,977 10.146 1.057 0.000 No 445.8 6.1 No Yes 2/16/2004 42,065 10.396 1.053 0.000 No 423.3 6.0 No Yes 6/3/2004 44,858 11.035 1.054 0.000 No 401.6 6.0 No Yes 9/16/2004 47,523 11.764 1.052 0.000 No 381.8 5.9 No Yes 3/21/2005 51,328 12.750 1.154 0.000 No 330.8 5.8 No Yes 8/11/2005 54,977 13.857 1.082 0.000 No 305.8 5.7 No Yes 3/23/2006 60,713 15.532 1.097 0.000 No 278.7 5.6 No Yes 8/10/2006 64,302 16.625 1.059 0.000 No 263.2 5.6 No Yes 11/21/2006 66,942 17.375 1.008 0.000 No 261.1 5.6 No Yes Level : C LPRM ID No. : 207 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.009 1.032 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.030 1.057 0.000 No 1,183.0 7.1 No Yes 11/23/1999 5,275 1.323 0.932 0.000 No 1,269.3 7.1 No Yes 5/18/2000 9,611 2.388 0.994 0.000 No 1,269.0 7.1 No Yes 12/8/2000 14,092 3.507 1.189 0.000 No 1,067.5 7.0 No Yes 1/9/2003 15,550 7.881 1.059 0.000 No 659.0 6.5 No Yes 8/16/2001 20,431 4.966 1.061 0.000 No 1,006.2 6.9 No Yes 11/29/2001 22,978 5.540 1.060 0.000 No 949.2 6.9 No Yes

Level : D LPRM ID No. : 293 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.006 0.970 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.020 1.007 0.000 No 1,250.0 7.1 No Yes 11/23/1999 5,275 0.833 0.949 0.000 No 1,317.2 7.2 No Yes 5/18/2000 9,611 1.509 0.975 0.000 No 1,317.0 7.2 No Yes 10/26/2000 13,620 2.238 0.945 0.000 No 1,393.7 7.2 No Yes 12/8/2000 14,092 2.332 1.107 0.000 No 1,258.9 7.1 No Yes 11/19/2002 14,272 5.282 1.102 0.000 No 1,057.8 7.0 No Yes 1/9/2003 15,550 5.587 1.052 0.000 No 1,005.6 6.9 No Yes 3/30/2001 16,962 2.725 0.939 0.000 No 1,340.7 7.2 No Yes 5/7/2002 26,607 4.266 1.085 0.000 No 1,235.7 7.1 No Yes 7/18/2002 28,480 4.703 1.060 0.000 No 1,165.7 7.1 No Yes 2/27/2003 33,184 5.644 1.136 0.000 No 885.2 6.8 No Yes 5/8/2003 34,945 5.863 1.057 0.000 No 837.4 6.7 No Yes 10/16/2003 38,885 6.442 1.053 0.000 No 795.3 6.7 No Yes 1/5/2004 40,977 6.765 1.063 0.000 No 748.2 6.6 No Yes 7/8/2004 45,715 7.355 1.054 0.000 No 709.8 6.6 No Yes 12/2/2004 49,512 8.163 1.059 0.000 No 670.3 6.5 No Yes 1/21/2005 50,803 8.523 1.127 0.000 No 594.7 6.4 No Yes 3/21/2005 51,328 8.670 1.081 0.000 No 550.2 6.3 No Yes 3/14/2002 25,649 6.222 1.088 0.000 No 872.4 6.8 No Yes 6/13/2002 27,571 6.682 1.081 0.000 No 807.1 6.7 No Yes 8/22/2002 29,375 7.096 1.075 0.000 No 750.8 6.6 No Yes 2/27/2003 33,184 7.953 1.166 0.000 No 565.2 6.3 No Yes 5/8/2003 34,945 8.365 1.066 0.000 No 530.2 6.3 No Yes 7/31/2003 36,969 8.854 1.055 0.000 No 502.5 6.2 No Yes 11/13/2003 39,615 9.465 1.065 0.000 No 471.9 6.2 No Yes 4/22/2004 43,775 10.272 1.052 0.000 No 448.6 6.1 No Yes 8/5/2004 46,441 10.831 1.056 0.000 No 425.0 6.1 No Yes 12/2/2004 49,512 11.639 1.066 0.000 No 398.7 6.0 No Yes 3/21/2005 51,328 12.166 1.122 0.000 No 355.3 5.9 No Yes 8/11/2005 54,977 12.951 1.051 0.000 No 338.1 5.8 No Yes 12/29/2005 58,559 13.769 1.052 0.000 No 321.4 5.8 No Yes 8/10/2006 64,302 15.348 1.068 0.000 No 300.9 5.7 No Yes 11/21/2006 66,942 16.124 1.045 0.000 No 288.0 5.7 No Yes

11 Good Value Yes Yes Yes Yes Yes Yes Good Value Yes Yes Yes Yes Yes Good Value Yes Yes Yes Yes Level : D LPRM ID No. : 575 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value String No. :

Coordinates :

36 17 Serial No. :

Type :

04582830 NA300 Cumulative Core Average Cycle Installed :

Exposure at BOC :

0 Level : A LPRM ID No. : 545 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No 4/28/2005 1,069 0.351 1.115 0.000 No 1,121.1 7.0 No 6/222005 1,962 0.671 1.051 0.000 No 1,066.7 7.0 No 3/23/2006 9,485 3.081 0.939 0.000 No 1,136.0 7.0 No 4/27/2006 10,382 3.345 1.074 0.000 No 1,057.7 7.0 No 11/21/2006 15,714 5.020 1.041 0.000 No 1,016.0 6.9 No Level : B LPRM ID No. : 555 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No 4/28/2005 1,069 0.331 1.068 0.000 No 1,170.4 7.1 No 3/23/2006 9,485 2.925 0.947 0.000 No 1,235.9 7.1 No 8/10/2006 13,074 3.992 1.055 0.000 No 1,171.5 7.1 No 11/21/2006 15,714 4.730 1.020 0.000 No 1,148.5 7.0 No Level : C LPRM ID No. : 565 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No 3/21/2005 100 0.027 1.062 0.000 No 1,177.0 7.1 No 8/11/2005 3,749 0.889 0.932 0.000 No 1,262.9 7.1 No 11/21/2006 15,714 4.119 1.003 0.000 No 1,259.1 7.1 No 6/222005 53,190 8.891 0.991 0.000 No 550.0 6.3 No Yes 12/29/2005 58,559 9.600 1.062 0.000 No 517.9 6.2 No Yes 2/9/2006 59,635 9.787 0.941 0.000 No 550.0 6.3 No Yes 3/23/2006 60,713 10.008 1.111 0.000 No 495.0 6.2 No Yes 7/6/2006 63,402 10.485 0.891 0.000 No 555.6 6.3 No Yes 8/10/2006 64,302 10.640 1.073 0.000 No 517.8 6.2 No Yes 10/19/2006 66,095 11.006 1.115 0.000 No 464.4 6.1 No Yes 11/21/2006 66,942 11.206 0.972 0.000 No 477.8 6.2 No Yes

11/21/2006 String No. :

Coordinates :

15,714 37 17 2.723 Serial No. :

Type :

0.988 00s10721 NA300 0.000 Cumulative No Core Average 1,368.8 Cycle Installed :

Exposure at BOC:

7.2 No 37,262 Yes 9

Level : A LPRM ID No. : 376 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.022 1.098 0.000 No 1,138.4 7.0 No Yes 11/19/2002 306 3.773 1.086 0.000 No 794.2 6.7 No Yes 1/9/2003 1,584 4.117 1.060 0.000 No 749.2 6.6 No Yes 12/27/2001 9,741 1.893 1.055 0.000 No 1,079.1 7.0 No Yes 3/14/2002 11,683 2.402 1.061 0.000 No 1,017.0 6.9 No Yes 5/7/2002 12,641 2.624 1.074 0.000 No 947.0 6.9 No Yes 7/18/2002 14,514 3.020 1.098 0.000 No 862.4 6.8 No Yes 2/27/2003 19,218 4.185 1.095 0.000 No 684.2 6.5 No Yes 4/3/2003 20,071 4.390 1.079 0.000 No 634.1 6.5 No Yes 7/31/2003 23,003 5.035 1.060 0.000 No 598.2 6.4 No Yes 9/4/2003 23,913 5.223 1.058 0.000 No 565.4 6.3 No Yes 10/16/2003 24,919 5.443 1.054 0.000 No 536.5 6.3 No Yes 2/16/2004 28,099 6.300 1.112 0.000 No 482.4 6.2 No Yes 6/3/2004 30,892 7.285 1.069 0.000 No 451.3 6.1 No Yes 9/16/2004 33,557 8.266 1.052 0.000 No 429.0 6.1 No Yes 3/21/2005 37,362 9.158 1.107 0.000 No 387.5 6.0 No Yes 7/7/2005 40,111 9.981 1.069 0.000 No 362.5 5.9 No Yes 10/13/2005 42,617 10.701 0.939 0.000 No 386.0 6.0 No Yes 11/17/2005 43,517 10.890 1.088 0.000 No 355.0 5.9 No Yes 6/1/2006 48,538 12.300 1.063 0.000 No 334.0 5.8 No Yes 7/6/2006 49,436 12.505 1.052 0.000 No 317.5 5.8 No Yes 11/21/2006 52,976 13.379 1.014 0.000 No 313.1 5.7 No Yes Level : B LPRM ID No. : 384 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 4/28/2005 1,069 0.133 1.054 0.000 No 1,186.0 7.1 No Yes 6/2/2005 1,962 0.247 0.926 0.000 No 1,280.7 7.2 No Yes 7/6/2006 12,174 1.967 0.947 0.000 No 1,352.4 7.2 No Yes

12/8/2000 126 0.026 1.085 0.000 No 1,152.1 7.0 No Yes 11/19/2002 306 4.018 1.074 0.000 No 772.4 6.6 No Yes 12/27/2001 9,741 2.117 1.064 0.000 No 1,082.8 7.0 No Yes 3/14/2002 11,683 2.623 1.110 0.000 No 975.5 6.9 No Yes 6/13/2002 13,605 3.128 1.098 0.000 No 888.4 6.8 No Yes 7/18/2002 14,514 3.376 1.071 0.000 No 829.5 6.7 No Yes 2/27/2003 19,218 4.398 1.135 0.000 No 680.5 6.5 No Yes 4/3/2003 20,071 4.666 1.084 0.000 No 627.8 6.4 No Yes 6/12/2003 21,885 5.214 1.063 0.000 No 590.6 6.4 No Yes 7/31/2003 23,003 5.543 1.055 0.000 No 559.8 6.3 No Yes 11/13/2003 25,649 6.223 1.058 0.000 No 529.1 6.3 No Yes 12/18/2003 26,544 6.433 1.052 0.000 No 502.9 6.2 No Yes 3/23/2004 29,031 7.131 1.062 0.000 No 473.6 6.2 No Yes 8/5/2004 32,475 8.131 1.070 0.000 No 443.0 6.1 No Yes 12/2/2004 35,546 8.975 1.084 0.000 No 408.7 6.0 No Yes 3/21/2005 37,362 9.423 1.154 0.000 No 354.1 5.9 No Yes 10/13/2005 42,617 10.888 1.051 0.000 No 337.0 5.8 No Yes 2/9/2006 45,669 11.693 1.061 0.000 No 318.0 5.8 No Yes 7/6/2006 49,436 12.702 1.064 0.000 No 298.9 5.7 No Yes 11/21/2006 52,976 13.583 1.040 0.000 No 287.4 5.7 No Yes Level : C LPRM ID No. : 392 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 12/8/2000 126 0.024 1.077 0.000 No 1,160.6 7.1 No Yes 12/12/2002 894 3.705 1.052 0.000 No 781.9 6.7 No Yes 1/11/2001 994 0.182 1.051 0.000 No 1,104.3 7.0 No Yes 3/30/2001 2,996 0.555 0.947 0.000 No 1,166.1 7.1 No Yes 1/31/2002 10,629 1.964 1.065 0.000 No 1,094.9 7.0 No Yes 5/7/2002 12,641 2.408 1.091 0.000 No 1,003.6 6.9 No Yes 7/18/2002 14,514 2.887 1.134 0.000 No 885.0 6.8 No Yes 9/26/2002 16,254 3.318 1.076 0.000 No 822.5 6.7 No Yes 2/27/2003 19,218 3.949 1.138 0.000 No 687.0 6.5 No Yes 6/12/2003 21,885 4.483 1.081 0.000 No 635.6 6.5 No Yes 10/16/2003 24,919 5.115 1.083 0.000 No 586.9 6.4 No Yes 12/18/2003 26,544 5.481 1.059 0.000 No 554.2 6.3 No Yes 3/23/2004 29,031 6.022 1.051 0.000 No 527.3 6.3 No Yes

String No. : 38 Serial No. : M5420 Cycle Installed :

7 Coordinates: 17 Type : NA300 Cumulative Core Average Exposure at BOC :

61,028 Level : A LPRM ID No. : 38 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value Level : D LPRM ID No.: 400 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gat's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 10/26/2000 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 1211222002 894 2.183 1.053 0.000 No 1,187.7 7.1 No Yes 1/11/2001 994 0.097 1.056 0.000 No 1,183.7 7.1 No Yes 3/30/2001 2,996 0.304 0.942 0.000 No 1,256.6 7.1 No Yes 8116/2001 6,465 0.726 0.947 0.000 No 1,326.9 7,2 No Yes 9/26/2002 16,254 1.905 1.061 0.000 No 1,250.6 7.1 No Yes 2/27/2003 19,218 2.364 1.114 0.000 No 1,066.1 7.0 No Yes 6/12/2003 21,885 2.628 1.072 0.000 No 994.5 6.9 No Yes 11/13/2003 25,649 3.073 1.067 0.000 No 932.1 6.8 No Yes 12/18/2003 26,544 3.187 1.056 0.000 No 882.7 6.8 No Yes 3/23/2004 29,031 3.512 1,074 0.000 No 821.8 6.7 No Yes 12/2/2004 35,546 4.701 1.072 0.000 No 766.6 6.6 No Yes 112112005 36,837 5.032 1.070 0.000 No 716.5 6.6 No Yes 3/21/2005 37,362 5.160 1.141 0.000 No 627.9 6.4 No Yes 6/2/2005 39,224 5.383 1.051 0.000 No 597.5 6.4 No Yes 7/7/2005 40,111 5.492 0.942 0.000 No 634.3 6.5 No Yes 8/11/2005 41,011 5.601 1.080 0.000 No 587.3 6.4 No Yes 4/27/2006 47,644 6.710 1.054 0.000 No 557.2 6.3 No Yes 7/6/2006 49,436 7.002 0.937 0.000 No 594.7 6.4 No Yes 8/10/2006 50,336 7.148 1.052 0.000 No 565.3 6.3 No Yes 11/21/2006 52,976 7.689 1.064 0.000 No 531.3 6.3 No Yes 8/5/2004 32,475 6.826 1.051 0.000 No 502.0 62 No Yes 10/21/2004 34,468 7,393 1.076 0.000 No 466.5 6.1 No Yes 12/29/2004 36,245 7.897 1.067 0.000 No 437.2 6.1 No Yes 3/21/2005 37,362 8.211 1.155 0.000 No 378.6 5.9 No Yes 11/17/2005 43,517 9.684 1.070 0.000 No 354.0 5.9 No Yes 6/112006 48,538 10.966 1.051 0.000 No 336.8 5.8 No Yes 8/10/2006 50,336 11,400 1.065 0.000 No 316.3 5.8 No Yes 11/21/2006 52,976 12.082 1.042 0.000 No 303.5 5.7 No Yes

11/21/2006 Level :

76,742 B

10.582 LPRM ID No. :

1.025 124 0.000 No Beginning of Life 462.1 Calibration Current :

6.1 No 1,250.0 Yes Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/9/2006

-10,308 11.556 1.053 0.000 No 392.0 6.0 No Yes 9/12/1996 9,490 1.065 1.032 0.000 Yes 1,025.0 6.9 No Yes 4/16/1999 9,848 1.093 0.921 0.000 No 1,114.0 7.0 No Yes 12/29/1999 15,955 2.162 1.076 0.000 No 1,035.3 6.9 No Yes 5/18/2000 19,411 2.807 1.075 0.000 No 963.1 6.9 No Yes 9/21/2000 22,542 3.365 1.070 0.000 No 900.1 6.8 No Yes 12/8/2000 23,892 3.579 1.192 0.000 No 755.1 6.6 No Yes 8/16/2001 30,231 4.644 1.065 0.000 No 709.0 6.6 No Yes 10/25/2001 31,880 4.950 1.066 0.000 No 665.1 6.5 No Yes 1/31/2002 34,395 5.449 1.063 0.000 No 625.7 6.4 No Yes 7/18/2002 38,280 6.239 1.064 0.000 No 588.1 6.4 No Yes 2/27/2003 42,984 6.991 1.079 0.000 No 545.0 6.3 No Yes 7/31/2003 46,769 7.693 1.061 0.000 No 513.7 6.2 No Yes 1/5/2004 50,777 8.383 1.054 0.000 No 487.4 6.2 No Yes 10/21/2004 58,234 9.712 1.058 0.000 No 460.6 6.1 No Yes 3/21/2005 61,128 10.163 1.059 0.000 No 435.0 6.1 No Yes 8/11/2005 64,777 10.850 1.053 0.000 No 413.1 6.0 No Yes 11/21/2006 76,742 12.469 1.013 0.000 No 387.0 6.0 No Yes 9/12/1996 9,490 0.711 1.023 0.000 Yes 1,021.0 6.9 No Yes 5/18/2000 19,411 2.308 1.006 0.000 No 1,021.0 6.9 No Yes 12/8/2000 23,892 2.947 1.197 0.000 No 853.0 6.7 No Yes 1/9/2003 25,350 5.887 1.052 0.000 No 610.1 6.4 No Yes 9/20/2001 30,967 3.918 1.079 0.000 No 790.5 6.7 No Yes 12/27/2001 33,507 4.341 1.080 0.000 No 732.0 6.6 No Yes 5/7/2002 36,407 4.908 1.082 0.000 No 676.5 6.5 No Yes 7/18/2002 38,280 5.216 1.054 0.000 No 641.8 6.5 No Yes 5/8/2003 44,745 6.245 1.065 0.000 No 572.9 6.4 No Yes 9/4/2003 47,679 6.720 1.054 0.000 No 543.5 6.3 No Yes 3/23/2004 52,797 7.496 1.055 0.000 No 515.2 6.2 No Yes 3/21/2005 61,128 8.706 1.057 0.000 No 487.4 6.2 No Yes 4/28/2005 62,097 8.876 1.055 0.000 No 462.0 6.1 No Yes 12/29/2005 68,359 9.721 1.051 0.000 No 439.6 6.1 No Yes 6/1/2006 72,304 10.190 0.928 0.000 No 473.7 6.2 No Yes

Level : C LPRM ID No. : 210 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 2/9/2006

-10,308 10.393 1.057 0.000 No 425.0 6.1 No Yes 9/12/1996 9,490 1.376 1.029 0.000 Yes 959.0 6.9 No Yes 4/16/1999 9,848 1.418 0.944 0.000 No 1,020.0 6.9 No Yes 12/29/1999 15,955 2.237 1.052 0.000 No 969.6 6.9 No Yes 5/18/2000 19,411 2.725 1.034 0.000 No 970.0 6.9 No Yes 9/21/2000 22,542 3.214 1.078 0.000 No 899.8 6.8 No Yes 12/8/2000 23,892 3.458 1.193 0.000 No 754.2 6.6 No Yes 2/15/2001 25,646 3.723 1.047 0.000 No 720.4 6.6 No Yes 3/30/2001 26,762 3.897 0.952 0.000 No 756.7 6.6 No Yes 8/16/2001 30,231 4.449 1.074 0.000 No 704.6 6.6 No Yes 10/25/2001 31,880 4.701 1.051 0.000 No 670.4 6.5 No Yes 3/14/2002 35,449 5.246 1.060 0.000 No 632.4 6.4 No Yes 7/18/2002 38,280 5.755 1.066 0.000 No 593.3 6.4 No Yes 2/27/2003 42,984 6.526 1.113 0.000 No 533.0 6.3 No Yes 2/16/2004 51,865 7.633 1.063 0.000 No 501.5 6.2 No Yes 7/8/2004 55,515 8.135 0.939 0.000 No 534.0 6.3 No Yes 9/16/2004 57,323 8.433 1.060 0.000 No 503.8 6.2 No Yes 4/28/2005 62,097 9.260 1.056 0.000 No 477.1 6.2 No Yes 9/8/2005 65,493 9.764 1.062 0.000 No 449.2 6.1 No Yes 8/10/2006 74,102 11.105 1.071 0.000 No 396.8 6.0 No Yes 11/21/2006 76,742 11.481 1.013 0.000 No 391.7 6.0 No Yes Level : D LPRM ID No. : 296 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 9/12/1996 9,490 1.258 1.046 0.000 Yes 1,029.0 6.9 No Yes 4/16/1999 9,848 1.305 0.904 0.000 No 1,143.0 7.0 No Yes 5/18/2000 19,411 2.052 1.026 0.000 No 1,143.0 7.0 No Yes 12/8/2000 23,892 2.490 1.164 0.000 No 982.0 6.9 No Yes 11/29/2001 32,778 3.233 1.067 0.000 No 920.3 6.8 No Yes 8/22/2002 39,175 3.866 1.076 0.000 No 855.3 6.8 No Yes 2/27/2003 42,984 4.308 1.099 0.000 No 778.2 6.7 No Yes 7/8/2004 55,515 5.169 0.875 0.000 No 889.4 6.8 No Yes 8/5/2004 56,241 5.244 1.054 0.000 No 844.0 6.7 No Yes 9/16/2004 57,323 5.369 1.003 0.000 No 844.0 6.7 No Yes

11/21/2006 String No. :

Coordinates:

76,742 39 9

7.719 Serial No. :

Type :

1.001 04s82824 NA300 0.000 Cumulative No Core Average 661.1 Cycle Installed :

Exposure at BOC :

6.5 No 0

Yes 11 Level : A LPRM ID No. : 546 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.022 1.107 0.000 No 1,129.2 7.0 No Yes 4/28/2005 1,069 0.299 1.063 0.000 No 1,062.3 7.0 No Yes 11/17/2005 6,255 1.572 0.913 0.000 No 1,163.0 7.1 No Yes 12/29/2005 7,331 1.772 1.086 0.000 No 1,070.9 7.0 No Yes 9/14/2006 13,968 3.244 1.052 0.000 No 1,018.0 6.9 No Yes 11/21/2006 15,714 3.617 0.965 0.000 No 1,054.9 7.0 No Yes Level : B LPRM ID No. : 556 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.028 0.936 0.000 No 1,335.5 7.2 No Yes 11/21/2006 15,714 3.644 1.020 0.000 No 1,309.3 7.2 No Yes Level : C LPRM ID No. : 566 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 11/21/2006 15,714 3.358 1.011 0.000 No 1,236.4 7.1 No Yes Level : D LPRM ID No. : 576 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/21/2005 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/21/2005 100 0.011 0.917 0.000 No 1,363.1 7.2 No Yes 6/2/2005 1,962 0.197 1.083 0.000 No 1,258.7 7.1 No Yes 8/11/2005 3,749 0.389 0.949 0.000 No 1,326.3 7.2 No Yes 4/27/2006 10,382 1.399 0.949 0.000 No 1,397.6 7.2 No Yes 3/21/2005 61,128 5.892 1.070 0.000 No 788.8 6.7 No Yes 7/7/2005 63,877 6.125 1.069 0.000 No 737.9 6.6 No Yes 9/8/2005 65,493 6.279 0.965 0.000 No 738.0 6.6 No Yes 6/1/2006 72,304 7.119 1.058 0.000 No 697.5 6.5 No Yes 7/6/2006 73,202 7.237 1.054 0.000 No 661.8 6.5 No Yes

11/21/2006 String No. :

Coordinates:

15,714 40 9

2.302 Serial No. :

Type :

0.998 02S41546 NA300 0.000 Cumulative No Core Average 1,400.4 Cycle installed :

Exposure at BOC :

7.2 No 18,162 Yes 10 Level : A LPRM ID No. : 446 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2127/2003 118 0.029 1.097 0.000 No 1,139.5 7.0 No Yes 9/4/2003 4,813 1.392 1.054 0.000 No 1,079.0 7.0 No Yes 12/18/2003 7,444 2.179 0.946 0.000 No 1,140.6 7.0 No Yes 4/22/2004 10,709 3.256 1.071 0.000 No 1,065.0 7.0 No Yes 7/7/2005 21,011 5.892 1.093 0.000 No 974.4 6.9 No Yes 11/17/2005 24,417 6.788 1.065 0.000 No 915.0 6.8 No Yes 12/29/2005 25,493 7.114 0.934 0.000 No 979.7 6.9 No Yes 3/23/2006 27,647 7.688 1.065 0.000 No 919.9 6.8 No Yes 4/27/2006 28,544 7.903 0.945 0.000 No 973.4 6.9 No Yes 6/1/2006 29,438 8.140 1.057 0.000 No 920.9 6.8 No Yes 7/6/2006 30,336 8.390 0.939 0.000 No 980.7 6.9 No Yes 8/10/2006 31,236 8.638 1.116 0.000 No 878.8 6.8 No Yes 11/21/2006 33,876 9.462 0.985 0.000 No 892.2 6.8 No Yes Level : B LPRM ID No. : 462 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 10/21/2004 15,368 4.129 1.062 0.000 No 1,177.0 7.1 No Yes 3/21/2005 18,262 4.873 1.102 0.000 No 1,068.1 7.0 No Yes 8/11/2005 21,911 5.816 1.077 0.000 No 991.7 6.9 No Yes 2/9/2006 26,569 7.101 1.051 0.000 No 944.0 6.9 No Yes 3/23/2006 27,647 7.363 1.067 0.000 No 884.7 6.8 No Yes 6/1/2006 29,438 7.800 1.076 0.000 No 822.2 6.7 No Yes 8/10/2006 31,236 8.257 1.066 0.000 No 771.3 6.6 No Yes 10/19/2006 33,029 8.734 1.074 0.000 No 718.2 6.6 No Yes 11/21/2006 33,876 8.963 1.002 0.000 No 716.7 6.6 No Yes Level : C LPRM ID No. : 478 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes

7.2 7.2 7.2 7.0 7.1 7.0 6.9 6.9 6.8 7.1 7.2 7.0 7.1 7.1 7.1 7.2 7.1 7.1 7.1 7.1 7.1 7.1 10 7.1 7.1 7.0 6.9 7.0 6.9 6.8 10/19/2006 11/21/2006 33,029 33,876 7.253 1.058 7.486 1.044 0.000 No 0.000 No 981.2 939.8 Level : D LPRM ID No. : 494 Beginning of Life Calibration Current :

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 4/22/2004 10,709 1.108 0.947 0.000 No 1,320.0 3/21/2005 18,262 2.502 1.181 0.000 No 1,117.7 6/2/2005 20,124 2.680 0.938 0.000 No 1,191.5 8/11/2005 21,911 2.879 0.946 0.000 No 1,259.6 9/8/2005 22,627 2.965 1.085 0.000 No 1,160.9 11/17/2005 24,417 3.202 0.905 0.000 No 1,283.0 12/29/2005 25,493 3.346 1.103 0.000 No 1,163.2 3/23/2006 27,647 3.699 0.947 0.000 No 1,228.3 7/6/2006 30,336 4.142 1.065 0.000 No 1,153.3 8/10/2006 31,236 4.308 0.908 0.000 No 1,270.2 10/19/2006 33,029 4.646 1.079 0.000 No 1,177.2 11/21/2006 33,876 4.812 0.987 0.000 No 1,192.7 String No. : 41 Serial No. : 02S41543 Cycle Installed :

Coordinates : 9 Type: NA300 Cumulative Core Average Exposure at BOC :

Level : A LPRM ID No. : 447 Beginning of Life Calibration Current:

No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 9/4/2003 4,813 0.830 0.947 0.000 No 1,320.0 3/23/2004 9,931 1.857 0.946 0.000 No 1,395.3 12/29/2004 17,145 3.564 1.068 0.000 No 1,306.5 3/21/2005 18,262 3.891 1.148 0.000 No 1,138.0 8/11/2005 21,911 4.546 0.943 0.000 No 1,206.8 12/29/2005 25,493 5.345 1.054 0.000 No 1,145.0 9/14/2006 32,130 7.013 1.103 0.000 No 1,038.1 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 2/27/2003 118 0.036 1.080 0.000 No 1,157.4 4/3/2003 971 0.308 1.098 0.000 No 1,054.1 10/16/2003 5,819 1.752 1.068 0.000 No 987.0 7/8/2004 12,649 3.965 0.934 0.000 No 1,056.7 8/5/2004 13,375 4.135 1.086 0.000 No 973.0 3/21/2005 18,262 5.183 1.104 0.000 No 881.3 18,162 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes

10/13/2005 23,517 6.613 1.063 0.000 No 829.1 6.7 No Yes 11/17/2005 24,417 6.904 0.946 0.000 No 876.0 6.8 No Yes 12/29/2005 25,493 7.264 1.100 0.000 No 796.4 6.7 No Yes 3/23/2006 27,647 7.841 0.885 0.000 No 899.8 6.8 No Yes 6/1/2006 29,438 8.276 1.149 0.000 No 783.2 6.7 No Yes 11/21/2006 33,876 9.729 1.010 0.000 No 775.4 6.7 No Yes Level : B LPRM ID No. : 463 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gal's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 7/31/2003 3,903 1.058 0.925 0.000 No 1,351.4 7.2 No Yes 12/29/2004 17,145 4.565 1.070 0.000 No 1,262.9 7.1 No Yes 3/21/2005 18,262 4.837 1.108 0.000 No 1,139.8 7.0 No Yes 7/7/2005 21,011 5.573 1.058 0.000 No 1,077.4 7.0 No Yes 10/13/2005 23,517 6.237 1.102 0.000 No 977.6 6.9 No Yes 11/17/2005 24,417 6.507 1.062 0.000 No 921.0 6.8 No Yes 12/29/2005 25,493 6.835 1.094 0.000 No 841.9 6.7 No Yes 2/9/2006 26,569 7.153 1.062 0.000 No 793.0 6.7 No Yes 3/23/2006 27,647 7.419 1.051 0.000 No 754.5 6.6 No Yes 6/1/2006 29,438 7.864 1.100 0.000 No 685.9 6.5 No Yes 8/10/2006 31,236 8.378 1.060 0.000 No 647.1 6.5 No Yes 9/14/2006 32,130 8.633 1.054 0.000 No 613.9 6.4 No Yes 11/21/2006 33,876 9.134 1.029 0.000 No 596.6 6.4 No Yes Level : C LPRM ID No. : 479 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/16/2004 8,999 1.675 0.940 0.000 No 1,329.8 7.2 No Yes 1/21/2005 17,737 3.725 1.059 0.000 No 1,255.7 7.1 No Yes 3/21/2005 18,262 3.875 1.089 0.000 No 1,153.1 7.1 No Yes 9/14/2006 32,130 6.989 1.061 0.000 No 1,086.8 7.0 No Yes 11/21/2006 33,876 7.484 1.026 0.000 No 1,059.2 7.0 No Yes Level : D LPRM ID No. : 495 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 7/31/2003 3,903 0.335 0.929 0.000 No 1,345.5 7.2 No Yes

2/9/2006 11/21/2006 String No. :

Coordinates :

26,569 33,876 42 9

3.492 4.832 Serial No. :

Type:

1.081 0.987 02S41540 NA300 0.000 0.000 Cumulative No No Core Average 1,271.0 1,287.7 Cycle Installed :

Exposure at BOC:

7.1 7.2 No No 18,162 Yes Yes 10 Level : A LPRM ID No. : 448 Beginning of Life Calibration Current:

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 2/27/2003 118 0.026 1.087 0.000 No 1,150.0 7.0 No Yes 4/3/2003 971 0.282 1.058 0.000 No 1,086.9 7.0 No Yes 11/13/2003 6,549 1.742 1.057 0.000 No 1,028.3 6.9 No Yes 9/16/2004 14,457 4.207 1.059 0.000 No 971.0 6.9 No Yes 3/21/2005 18,262 4.994 1.100 0.000 No 882.7 6.8 No Yes 8/11/2005 21,911 6.036 1.090 0.000 No 809.9 6.7 No Yes 9/8/2005 22,627 6.221 0.871 0.000 No 929.8 6.8 No Yes 10/13/2005 23,517 6.398 1.087 0.000 No 855.4 6.8 No Yes 11/17/2005 24,417 6.576 0.928 0.000 No 922.0 6.8 No Yes 12/29/2005 25,493 6.815 1.132 0.000 No 814.5 6.7 No Yes 2/9/2006 26,569 7.108 0.922 0.000 No 883.0 6.8 No Yes 4/27/2006 28,544 7.635 1.084 0.000 No 814.6 6.7 No Yes 7/6/2006 30,336 8.087 0.948 0.000 No 859.3 6.8 No Yes 9/14/2006 32,130 8.482 1.084 0.000 No 792.7 6.7 No Yes 11/21/2006 33,876 8.975 0.988 0.000 No 802.3 6.7 No Yes Level : B LPRM ID No. : 464 Beginning of Life Calibration Current :

1,250.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 7.1 No Yes 3/23/2004 9,931 2.506 0.939 0.000 No 1,331.2 7.2 No Yes 12/2/2004 16,446 4.227 1.052 0.000 No 1,265.4 7.1 No Yes 1/21/2005 17,737 4.535 1.058 0.000 No 1,196.0 7.1 No Yes 3/21/2005 18,262 4.665 1.166 0.000 No 1,025.8 6.9 No Yes 12/29/2005 25,493 6.508 1.051 0.000 No 976.0 6.9 No Yes 3/23/2006 27,647 7.078 1.097 0.000 No 889.7 6.8 No Yes 8/5/2004 13,375 1.423 0.906 0.000 No 1,485.0 7.3 No Yes 3/21/2005 18,262 2.478 1.130 0.000 No 1,314.2 7.2 No Yes 9/8/2005 22,627 2.952 1.053 0.000 No 1,248.0 7.1 No Yes 12/29/2005 25,493 3.330 0.908 0.000 No 1,374.5 7.2 No Yes

6.7 6.7 6.6 6.6 7.1 7.0 7.1 7.0 6.9 6.8 7.1 7.2 7.1 7.2 7.3 7.3 7.3 7.2 7.1 7.2 7.1 7.2 7.2 7.2 8

51,228

-99.0 Good Byp.?

Value 7.1 No Yes 7.1 No Yes 7/8/2004 10/21/2004 3/21/2005 11/21/2006 12,649 15,368 18,262 33,876 2.330 3.014 3.804 7.475 0.934 1.064 1.188 1.034 0.000 No 0.000 No 0.000 No 0.000 No 1,222.2 1,148.7 966.9 935.1 Level : D LPRM ID No. : 496 Beginning of Life Calibration Current :

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 2/27/2003 118 0.009 0.930 0.000 No 1,344.1 4/3/2003 971 0.067 1.067 0.000 No 1,259.7 11/13/2003 6,549 0.572 0.939 0.000 No 1,341.5 6/3/2004 11,792 1.165 0.948 0.000 No 1,415.1 8/5/2004 13,375 1.382 0.944 0.000 No 1,499.0 10/21/2004 15,368 1.731 1.053 0.000 No 1,423.6 3/21/2005 18,262 2.374 1.082 0.000 No 1,315.7 11/17/2005 24,417 3.107 1.083 0.000 No 1,215.0 12/29/2005 25,493 3.264 0.872 0.000 No 1,393.3 2/9/2006 26,569 3.417 1.094 0.000 No 1,274.0 6/1/2006 29,438 3.884 0.921 0.000 No 1,383.3 7/6/2006 30,336 4.039 1.068 0.000 No 1,295.2 11/21/2006 33,876 4.701 1.015 0.000 No 1,276.1 String No. : 43 Serial No. : 96SO0499 Cycle Installed :

Coordinates : 9 Type : NA300 Cumulative Core Average Exposure at BOC :

Level : A LPRM ID No. : 43 Beginning of Life Calibration Current :

No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes 1,250.0 Good Byp.?

Value No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes 6/1/2006 29,438 7.540 1.066 0.000 No 834.6 8/10/2006 31,236 7.954 1.061 0.000 No 786.6 9/14/2006 32,130 8.159 1.056 0.000 No 744.9 11/21/2006 33,876 8.599 1.053 0.000 No 707.4 Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 4/16/1999 48 0.010 1.029 0.000 No 1,250.0 4/20/1999 146 0.031 1.038 0.000 No 1,250.0 Level : C LPRM ID No. : 480 Beginning of Life Calibration Current :

Total Pre-Cal Post-Cal Gaf's Exp.

Date CAVEX Exp GAF GAFpost Corrected CalCur 1/9/2003 0

0.000 1.000 0.000 No 1,250.0 4/3/2003 971 0.151 1.095 0.000 No 1,141.6

Level : B LPRM ID No. : 129 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.011 0.962 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.030 0.963 0.000 No 1,250.0 7.1 No Yes 2/3/2000 7,038 1.354 0.947 0.000 No 1,320.0 7.2 No Yes 5/18/2000 9,611 1.870 1.010 0.000 No 1,320.0 7.2 No Yes 12/8/2000 14,092 2.709 1.173 0.000 No 1,125.3 7.0 No Yes 4/16/2001 17,332 3.234 0.942 0.000 No 1,194.6 7.1 No Yes 1/31/2002 24,595 4.509 1.062 0.000 No 1,124.9 7.0 No Yes 8/22/2002 29,375 5.451 1.056 0.000 No 1,065.2 7.0 No Yes 2/27/2003 33,184 6.046 1.094 0.000 No 973.7 6.9 No Yes 5/8/2003 34,945 6.409 1.058 0.000 No 920.3 6.8 No Yes 7/31/2003 36,969 6.812 1.062 0.000 No 866.6 6.8 No Yes 10/16/2003 38,885 7.178 1.057 0.000 No 819.8 6.7 No Yes 1/5/2004 40,977 7.558 1.092 0.000 No 750.8 6.6 No Yes 4/22/2004 43,775 8.099 1.068 0.000 No 703.0 6.6 No Yes 8/5/2004 46,441 8.620 1.052 0.000 No 668.0 6.5 No Yes 12/2/2004 49,512 9.183 1.094 0.000 No 610.6 6.4 No Yes 3/21/2005 51,328 9.464 1.105 0.000 No 552.6 6.3 No Yes 6/2/2005 53,190 9.821 1.058 0.000 No 522.3 6.3 No Yes 11/17/2005 57,483 10.604 1.073 0.000 No 487.0 6.2 No Yes 4/27/2006 61,610 11.290 1.062 0.000 No 458.6 6.1 No Yes 11/21/2006 66,942 11.982 1.024 0.000 No 447.8 6.1 No Yes Level : C LPRM ID No. : 215 Beginning of Life Calibration Current:

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.008 0.973 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.021 0.984 0.000 No 1,250.0 7.1 No Yes 5/25/1999 970 0.185 1.086 0.000 No 1,151.0 7.0 No Yes 5/18/2000 9,611 1.750 0.991 0.000 No 1,151.0 7.0 No Yes 12/8/2000 14,092 2.420 1202 0.000 No 957.6 6.9 No Yes 1/9/2003 15,550 5.194 1.025 0.000 No 723.4 6.6 No Yes 11/29/2001 22,978 3.596 1.059 0.000 No 904.2 6.8 No Yes 12/27/2001 23,707 3.717 1.051 0.000 No 860.3 6.8 No Yes 5/7/2002 26,607 4.219 1.103 0.000 No 780.0 6.7 No Yes 7/18/2002 28,480 4.508 1.052 0.000 No 741.4 6.6 No Yes

12/29/1999 6,155 0.899 0.943 0.000 No 1,325.6 7.2 No Yes 5/18/2000 9,611 1.436 0.998 0.000 No 1,326.0 7.2 No Yes 12/8/2000 14,092 2.239 1.167 0.000 No 1,136.2 7.0 No Yes 3/30/2001 16,962 2.660 0.908 0.000 No 1,251.4 7.1 No Yes 8/22/2002 29,375 4.634 1.062 0.000 No 1,178.3 7.1 No Yes 5/8/2003 34,945 5.456 1.052 0.000 No 1,120.1 7.0 No Yes 11/13/2003 39,615 6.093 1.051 0.000 No 1,065.7 7.0 No Yes 2/16/2004 42,065 6.454 1.056 0.000 No 1,009.2 6.9 No Yes 9/16/2004 47,523 7.330 1.073 0.000 No 940.5 6.8 No Yes 12/2/2004 49,512 7.712 1.068 0.000 No 880.7 6.8 No Yes 12/29/2004 50,211 7.845 1.036 0.000 No 850.1 6.7 No Yes 3/21/2005 51,328 8.050 1.155 0.000 No 762.5 6.6 No Yes 7/7/2005 54,077 8.490 1.068 0.000 No 713.9 6.6 No Yes 10/13/2005 56,583 8.913 1.076 0.000 No 663.5 6.5 No Yes 2/9/2006 59,635 9.436 1.059 0.000 No 627.0 6.4 No Yes 7/6/2006 63,402 10.048 1.076 0.000 No 582.7 6.4 No Yes 11/21/2006 66,942 10.582 1.045 0.000 No 557.6 6.3 No Yes Level : D LPRM ID No. : 301 Beginning of Life Calibration Current :

-99.0 Total Pre-Cal Post-Cal Gaf's Exp.

Good Date CAVEX Exp GAF GAFpost Corrected CalCur Byp.?

Value 4/16/1999 48 0.004 0.969 0.000 No 1,250.0 7.1 No Yes 4/20/1999 146 0.011 0.976 0.000 No 1,250.0 7.1 No Yes 2/3/2000 7,038 0.584 0.945 0.000 No 1,322.8 7.2 No Yes 5/18/2000 9,611 0.806 1.003 0.000 No 1,323.0 7.2 No Yes 12/8/2000 14,092 1.283 1.114 0.000 No 1,187.6 7.1 No Yes 3/30/2001 16,962 1.495 0.918 0.000 No 1,293.7 7.2 No Yes 12/27/2001 23,707 2.062 0.929 0.000 No 1,392.6 7.2 No Yes 6/12/2003 35,851 3.203 1.053 0.000 No 1,322.5 7.2 No Yes 9/4/2003 37,879 3.337 0.948 0.000 No 1,395.0 7.2 No Yes 10/16/2003 38,885 3.412 1.059 0.000 No 1,317.3 7.2 No Yes 7/8/2004 45,715 3.999 0.889 0.000 No 1,481.8 7.3 No Yes 10/21/2004 48,434 4.340 1.053 0.000 No 1,407.2 7.2 No Yes 12/29/2004 50,211 4.613 1.052 0.000 No 1,337.6 7.2 No Yes 3/21/2005 51,328 4.790 1.099 0.000 No 1,217.1 7.1 No Yes 8/11/2005 54,977 5.149 1.074 0.000 No 1,133.3 7.0 No Yes 9/8/2005 55,693 5.228 1.052 0.000 No 1,077.3 7.0 No Yes 4/27/2006 61,610 6.018 1.055 0.000 No 1,021.1 6.9 No Yes

10/19/2006 66,095 6.616 1.069 0.000 No 955.2 6.9 No Yes 11/21/2006 66,942 6.739 1.023 0.000 No 9337 6.8 No Yes