CNRO-2008-00034, Stations Request ISI-2008-1 - Use of Later ASME Section XI Code Edition and Addenda for Repair and Replacement, Pressure Testing, and Non Destructive Examination Activities

From kanterella
(Redirected from ML083500367)
Jump to navigation Jump to search

Stations Request ISI-2008-1 - Use of Later ASME Section XI Code Edition and Addenda for Repair and Replacement, Pressure Testing, and Non Destructive Examination Activities
ML083500367
Person / Time
Site: Pilgrim, Vermont Yankee  File:NorthStar Vermont Yankee icon.png
(DPR-028, DPR-035)
Issue date: 12/01/2008
From: Ford B
Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CNRO-2008-00034
Download: ML083500367 (11)


Text

-Entergy Entergy Nuclear Operations, Inc.

1340 Echelon Parkway Jackson, Mississippi 39213-8298 Tel 601-368-5758 Bryan S. Ford Senior Manager, Nuclear Safety &

Licensing CNRO-2008-00034 December 1, 2008 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Request ISI-2008-1 Use of Later ASME Section Xl Code Edition and Addenda for Repair and Replacement, Pressure Testing, and Non Destructive Examination Activities Pilgrim Nuclear Power Station Docket No. 50-293 License No. DPR-35 Vermont Yankee Nuclear Power Station Docket No. 50-271 License No. DPR-28

REFERENCE:

Entergy Letter to the NRC dated August 22, 2007, Request ISI-2007-1, Use of Later ASME Section Xl Code Edition and Addenda for Repair/replacement, Pressure Testing, and Nondestructive ISI Examination Activities

Dear Sir or Madam:

Pursuant to 10 CFR 50.55a(g)(4)(iv), Entergy Nuclear Operations, Inc. (Entergy) requests permission to use the 2001 Edition/2003 Addenda of ASME Section XI for the performance of ISI related activities associated with repair/replacements, pressure testing, and NDE. The NRC has approved these editions and addenda of Section Xl as documented in 10 CFR 50.55a(b)(2). Regarding performance demonstration of ultrasonic examinations, Entergy requests permission to use the 2001 Edition of ASME Section XI as specified in 10 CFR 50.55a(b)(2)(xxiv). This request, ISI-2008-1, is applicable to Pilgrim (PNPS) and Vermont Yankee (VY) Nuclear Power Stations and is provided in the enclosure to this letter.

Entergy is seeking approval of ISI-2008-1 in order to maintain a standard program among its nuclear facilities for repair/replacement, pressure testing, and NDE activities.

Entergy is providing this request in accordance with NRC Regulatory Issue Summary 2004-16, Use of Later Editions and Addenda to ASME Code Section Xl for Repair/Replacement Activities.

u40(-g

CNRO-2008-00034 Page 2 of 3

'Entergy requests approval of this request on or before May 29, 2009. Should you have any questions regarding this submittal, please contact Bryan Ford at (601) 368-5516.

This letter contains no commitments.

Very truly yours, BSFNVBB

Enclosure:

Request ISI-2008-1 : Proposed ASME Section Xl Codes of Record for PNPS and VY cc.

Mr. Samuel J. Collins (w/o Attachment)

Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mr. James S. Kim, Project Manager Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop O-8C2A Washington, DC 20555 USNRC Resident Inspector Entergy Nuclear Vermont Yankee, LLC 320 Governor Hunt Road Vernon, Vermont 05354 Mr. David O'Brien, Commissioner VT Department of Public Service 112 State Street - Drawer 20 Montpelier, Vermont 05620-2601 Mr. James Shea, Project Manager Office of Nuclear Reactor Regulation Mail Stop: 0-8B-1 U.S. Nuclear Regulatory Commission 1 White Flint North 11555 Rockville Pike Rockville, MD 20852

CNRO-2008-00034 Page 3 of 3 U.S. Nuclear Regulatory Commission Region 1 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Pilgrim Nuclear Power Station

CNRO-2008-00034

  • bcc:

Ms. C. D. Faison (K-WPO-12C)

Mr. R. S. Lewis (M-ECH-36)

Mr. 0. Limpias (ECH)

Mr. D. J. Mannai (V-VYP-103)

Echelon Information Management File

ENCLOSURE CNRO-2008-00034 ISI-2008-1 REQUEST IN ACCORDANCE WITH 10 CFR 50.55a(g)(4)(iv) FOR USE OF LATER ASME SECTION XI CODE EDITION AND ADDENDA FOR REPAIR/REPLACEMENT, PRESSURE TESTING, AND NONDESTRUCTIVE ISI EXAMINATION ACTIVITIES

CNRO-2008-00034 ENTERGY OPERATIONS, INC.

10 CFR 50.55a Request ISI-2008-1 REQUEST IN ACCORDANCE WITH 10 CFR 50.55a(g)(4)(iv) FOR USE OF LATER ASME SECTION XI CODE EDITION AND ADDENDA FOR REPAIR/REPLACEMENT, PRESSURE TESTING, AND NONDESTRUCTIVE EXAMINATION ACTIVITIES

1. ASME Code Components Affected Class 1, 2, 3, and MC components, component supports, and welds in the ASME Section Xl pressure boundary at Pilgrim Nuclear Power Station (PNPS) and Vermont Yankee (VY).

2. Applicable Code Edition and Addenda

Inservice Inspection (ISI) related activities such as repair/replacements, pressure testing, and nondestructive examination (NDE) at PNPS and VY are currently performed in accordance with the 1998 Edition/2000 Addenda of ASME Section Xl with various NRC approved alternatives which are specified in the PNPS and VY ISI Programs. PNPS and VY also comply with all applicable 10 CFR 50.55a conditions and limitations.

3. Proposed Subsequent Code Edition and Addenda (or Portion)

A. Background PNPS and VY perform ISI related activities such as repair/replacements, pressure testing, and NDE in accordance with the 1998 Edition/2000 Addenda as described in Section 2 above. However, at other Entergy nuclear stations - Arkansas Nuclear One, Units 1 and 2 (ANO-1 & 2), Grand Gulf Nuclear Station (GGNS), Indian Point Energy Center, Unit 2 (IPEC-2), James A. FitzPatrick (JAF), Palisades Nuclear Plant (PLP),

River Bend Station (RBS), and Waterford Steam Electric Station Unit 3 (WF3) - these activities are currently performed in accordance with the 2001 Edition/2003 Addenda of ASME Section Xl except for alternatives (e.g. ASME Section Xl Code Cases) approved by the NRC in accordance with 10 CFR 50.55a and as listed below.

0 Performance demonstration of ultrasonic examinations complies with the 2001 Edition/No Addenda of Appendix VIII to comply with 10 CFR 50.55a(b)(2)(xxiv).

The NDE provision in IWA-4540(a)(2) of the 2001 Edition/2002 Addenda are applied when performing system leakage tests after repair/replacement activities involving welding or brazing to comply with 10 CFR 50.55a(b)(2)(xx)(B).

Pressure testing of mechanical joints of Class 1, 2, and 3 items are performed in accordance with IWA-4540(c) of the 1998 Edition/No Addenda to comply with 10 CFR 50.55a(b)(2)(xxvi).

Entergy is in the process of standardizing the performance of ISI related activities across the entire nuclear fleet. While ISI Program Plans will be controlled in site-specific documents, the repair/replacement, pressure testing, and NDE programs will be controlled in common program documents that will be corporately implemented across 1 of 3

CNRO-2008-00034 Entergy is in the process of standardizing the performance of ISI related activities across the entire nuclear fleet. While ISI Program Plans will be controlled in site-specific documents, the repair/replacement, pressure testing, and NDE programs will be controlled in common program documents that will be corporately implemented across the entire nuclear fleet. To do this, the ASME Section Xl Code of Record for ISI related activities at PNPS and VY must be updated to comply with the Code of Record used at other Entergy nuclear stations as described above.

B. Proposed Subsequent Code Edition and Addenda Pursuant to 10 CFR 50.55a(g)(4)(iv), Entergy requests permission to utilize the 2001 Edition/2003 Addenda of ASME Section Xl at PNPS and VY for the performance of repair/replacements, pressure testing, and NDE with the exceptions noted below:

Performance demonstration of ultrasonic examinations will be performed in accordance with the 2001 Edition/No Addenda of Appendix VIII to comply with 10 CFR 50.55a(b)(2)(xxvi).

The NDE provision in IWA-4540(a)(2) of the 2001 Edition/2002 Addenda will be applied when performing system leakage tests after repair/replacement activities involving welding or brazing to comply with 10 CFR 50.55a(b)(2)(xx)(B).

Pressure testing of mechanical joints of Class 1, 2, and 3 items will be performed in accordance with IWA-4540(c) of the 1998 Edition/No Addenda to comply with 10 CFR 50.55a(b)(2)(xxiv).

All NRC conditions, limitations, and restrictions in 10 CFR 50.55a that are applicable to the 2001 Edition/2003 Addenda of ASME Section XI will be met.

It is important to note that this request does not apply to the selection, planning, or scheduling of ISI examinations and tests as defined in IWB-, IWC-, IWD-, IWE-, and IWF-2500 or NRC approved ISI alternatives. Therefore, ISI examinations and tests at PNPS and VY will continue to be selected, planned, and scheduled in accordance with its present code of record as described in Section 2, above. See Attachment 1 for specific details regarding this proposal.

4. Related Requirements Entergy is requesting permission to use the 2001 Edition/2003 Addenda of ASME Section X1 for the performance of repair/replacements, pressure testing, and NDE with the exceptions noted in Section 3.B, above. In making this request, Entergy will comply with all related requirements in ASME Section XI as described below:

Entergy has proposed to utilize all "Articles" (e.g. IWA-4000, IWA-5000) from every "Subsection" (e.g. IWA, IWB, etc.) of the 2001 Edition/2003 Addenda that could be used or referenced for the performance of repair/replacement, pressure testing, and NDE activities. Entergy has also stated that it will comply with all "Mandatory Appendices" of the 2001 Edition/2003 Addenda.

Entergy will use Appendix VIII from the 2001 Edition/No Addenda of ASME Section XI in accordance with the NRC restriction in paragraph (b)(2)(xxiv) of 10 CFR 50.55a.

2 of 3

CNRO-2008-00034 However, this appendix includes all pertinent requirements for performance demonstration of ultrasonic examination systems.

Entergy will comply with IWA.4540(a) of the 2001 Edition/2002 Addenda and IWA-4540(c) of the 1998 Edition/No Addenda for pressure testing to comply with paragraphs (b)(2)(xx)(B) and (b)(2)(xxvi) of 10 CFR 50.55a. Because all applicable requirements are included in these two code paragraphs, no other ASME Section Xl code paragraphs need be invoked.

With regard to the performance of ISI examinations and tests, Entergy will continue to select, plan, and schedule these ISI inspection activities - as specified in IWA-, IWB-,

IWC-, IWD-, IWE-, and IWF-2500 or NRC approved ISI alternatives - in accordance with the PNPS and VY current ISI Program Plan. See Attachment 1 for more details.

5. Duration of Proposed Request PNPS and VY are presently in their fourth 10-Year ISI intervals. The effective dates for the ISI intervals are listed below:

PNPS: July 1, 2005 thru July 30, 2015 VY:

September 1,2003 thru August 31, 2013 The duration of this request will be from implementation of this alternative following approval by the NRC until the end of the fourth ISI intervals for PNPS and VY.

3 of 3

CNRO-2008-00034 REQUEST ISI-2008-1 ATTACHMENT I PROPOSED ASME SECTION XI CODES OF RECORD FOR PNPS AND VY

CNRO-2008-00034 PROPOSED ASME SECTION XI CODE OF RECORD FOR PNPS AND VY ASME :Secin ASME Section 'Xl Codeb Provi's ion Code Edaitio n/Addenda4'

.1998 Edition/

2001 Edition/

.,-.2001 Edition/

S A2000 Addenda N0 Addenda" 2003Addenda.

IWA-1000 X

IWA-2000 X2 X_

S0IWA-3000 X

q IWA-4000 IWA-5000 X

IWA-6000 X

IWA-9000 X

IWB-1000 X

n, U)

IWB-2000 0E IWB-3000 X

IWB-5000 X

04 *IWC-1000 X1

-r u

SX1

,f 0

IWC-2000 c), E IWC-3000 X

IWC-5000 X

U) c)

IWD-1000 X1

(])o/

X1 i2 0 IWD-2000 E

IWD-3000

  • _X IWD-5000 X

C IWE-1 000 X1 0 U t o

)1 Q

, IWE-2000 W

oE IWE-3000 x

.00

_ )

IWE-5000 X

w IWF-1000 X1 Q' En M C o IWF-2000 LL C 2C

. 3 IWF-3000 X

IWF-5000 X

I x

III X

0.

IV X

V x

0 VI X

-o VII X

VIII X

Ix x

1 of 2

CNRO-2008-00034 PROPOSED ASME SECTION Xl CODE OF RECORD FOR PNPS AND VY Notes:

(1) The selection, planning, and scheduling of ISI examinations/tests will comply with these ASME Section XI articles (e.g. IWB-1 000 and 2000) or applicable NRC approved alternatives that are specified in the PNPS and VY ISI Program Plans. Therefore, PNPS and VY will continue to comply with its original Code of Record when performing these ISI activities.

(2) PNPS and VY are proposing to use IWA-2100, 2200, and 2300 from the 2001 Edition/2003 Addenda for requirements applicable to authorized inspection, examination methods, and qualification of NDE personnel. However, PNPS and VY will continue to comply with its original Code of Record when using IWA-2400, 2500, 2600 for the selection, planning, and scheduling of ISI examinations and tests.

(3) As exceptions to IWA-4000 of the 2001 Edition/2003 Addenda, PNPS and VY will comply with the alternatives listed below to comply with NRC restrictions in 10 CFR.55a:

The NDE provision in IWA-4540(a)(2) of the 2001 Edition/2002 Addenda will be applied when performing system leakage tests after repair/replacement activities involving welding or.brazing to comply with 10 CFR 50.55a(b)(2)(xx)(B).

Pressure testing of mechanical joints of Class 1, 2, and 3 items will be performed in accordance with IWA-4540(c) of the 1998 Edition/No Addenda to comply with 10 CFR 50.55a(b)(2)(xxvi).

(4) Entergy will also comply with all NRC conditions, limitations, and restrictions specified in 10 CFR 50.55a.

2 of 2