Text

Brltt T. McKinney PPL Susquehanna, LLC Senior Vice President & Chief Nuclear Officer 769 Salem Boulevard OCT 2 520 06 Berwick, PA 18603 Tel.570.542.3149 Fax 570.542.1504 btmckinney@pplweb.com PP TM U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop OPl-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION SUPPLEMENT TO PROPOSED LICENSE AMENDMENT NUMBERS 285 FOR UNIT 1 OPERATING LICENSE NO. NPF-14 AND 253 FOR UNIT 2 OPERATING LICENSE NO. NPF-22:

CONSTANT PRESSURE POWER UPRATE Do(

PIA-6128 eket Nos. 50-387 and 50-388

Reference:

PLA-6076, B. T. McKinney (PPL) to Document Control Desk (USNRC),

"Proposed License Amendment Numbers 285for Unit 1 Operating License No. NPF-14 and 253for Unit 2 License NPF-22: Constant Pressure Power Uprate,"

dated October 11, 2006.

On October 11, 2006, PPL Susquehanna (PPL) provided the Constant Pressure Power Uprate license amendment request (Reference 1), which included a statement that steam dryer supplemental information would be submitted in January 2007. The purpose of this letter is to establish a formal regulatory commitment (attached) for PPL to provide this information to the NRC in January 2007.

Any questions regarding this matter should be directed to Mr. Michael H. Crowthers at (610) 774-7766.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on:

/o-o6 B. T. McKinney Attachment - Regulatory Commitment cc:

NRC Region I Mr. A. J. Blarney, NRC Sr. Resident Inspector Mr. R. V. Guzman, NRC Project Manager Mr. R. Janati, DEP/BRP ADD'

ATTACHMENT TO PLA-6128 PPL SUSQUEHANNA REGULATORY COMMITMENT

Attachment to PLA-6128 Page 1 of I Regulatory Commitment The following table identifies those actions committed to by PPL Susquehanna in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments. Please direct questions regarding this commitment to Michael H. Crowthers at (610) 774-7766.

REGULATORY COMIMITMENT...

DUE DATE Submit supplemental information to NRC January 31, 2007 which provides:

(1) A summary of proposed steam dryer structural modifications (2) The results of the final finite element analysis at 120% original licensed thermal power (OLTP based on the final dryer structural configuration)

(3) ASME load combination tables based on the 120% OLTP condition (4) A description of the steam dryer power ascension test plan.