Alexander Adams - Clarification of RAI 16 and 17 4

Page 1 From:

Alexander Adams To:

William Vernetson Date:

5/18/06 9:04AM

Subject:

Clarification of RAI 16 and 17 Bill During our conversation last week about the conversion RAls, you asked for a clarification of RAI 16 and 17.

Section 13.1.3 -- The explanation of why the reactivity initiated event will not lead to unacceptable consequences can either be based on specific transient calculations or comparisons with results from other reactors; in conjunction with limits based on the SPERT tests. However, the direct use of results from SPERT as exemplified by Equations 13.4 and 13.5 may not be justified as the SPERT reactor differs considerably from the UFTR. Equation (13.5) implies SPERT-1 and UFTR have similar power peaking and thermal capacity for the fuel plates. Tmax of 1500 C estimated for SPERT-1 (Table 13-5) came from NUREG/CR-2079. However the NUREG/CR report did not provide any basis for the estimate. On the other hand the Tmax for the Argonaut-UTR can be obtained from a plot of maximum measured temperatures versus total energy release (Fig. C-21) in SPERT test report IDO-16883. (This report has the exact same title as Ref. 18. in the UFTR conversion SAR. Could there be an error in the report number for Ref. 18?) UFTR may want to consider the merits of scaling Tmax basing on the analysis presented in NUREG/CR-2079. Also note that it is possible to directly calculate the factor b from the fuel specific heat, fuel temperature reactivity coefficient and neutron lifetime. Your answers to RAI 16 and 17 should provide a coherent and consistent explanation of the limits of the fuel to be used in the LEU core.

Al Adams CC:

Bet; Deh3; diamondebnl.gov; mmm

c:\\temp\\GW}00002.TMP Page 1 Mail Envelope Properties (446C70DC.741: 8: 35504)

Subject:

Creation Date From:

Created By:

Clarification of RAI 16 and 17 05/18/2006 9:04:28 AM Alexander Adams AXAgnrc.gov Recipients bnl.gov diamond CC (diamond~bnl.gov) nrc.gov OWGWPO02.HQGWDO0 1 DEH3 CC (Deh3) nrc.gov TWGWPO01.HQGWDO01 MMM CC (mmm) nrc.gov TWGWPO02.HQGWDO0 1 BET CC (Bet) ufl.edu vernet (William Vernetson)

Post Office OWGWPO02.HQGWDO0 1 TWGWPO0 1.HQGWDO0 1 TWGWPOO2.HQGWDOO 1 Route bnl.gov nrc.gov nrc.gov nrc.gov ufl.edu Files MESSAGE Options Expiration Date:

Priority:

ReplyRequested:

Return Notification:

Size 2115 Date & Time 05/18/2006 9:04:28 AM None Standard No None Concealed

Subject:

No

c:\\temp\\GW}00002.TMP Page 2 Security:

Standard