Don E. Grissette Vice President Southern Nuclear Operating Company, Inc.
40 lnverness Center Parkway Post Office Box 1295 Birmingham, Alabama 35201 Tel 205.992.6474 Fax 205.992.0341 October 20, 2005 Docket No.:
50-425
\\
SOUTHERN&
COMPANY Energy to Serve Your WorId' U. S. Nuclear Regulatory Commission ATT'N: Document Control Desk Washington, D. C. 20555-0001 Vogtle Electric Generating Plant Technical Specification Report 2-2005-1 Number of Steam Generator Tubes Plugged During 2R11 Ladies and Gentlemen:
In accordance with the requirements of Vogtle Electric Generating Plant Technical Specification 5.6.10, Southern Nuclear Operating Company submits this report of the number of steam generator (SG) tubes plugged during the Unit 2 eleventh maintenancelrefi~eling outage (2R11).
As a result of the SG tube inservice inspections completed on October 2,2005, no tubes were plugged.
This letter contains no NRC commitments. If you have any questions, please advise.
Sincerely, Don E. Grissette cc:
Southern Nuclear Operating Companv Mr. J. T. Gasser, Executive Vice President Mr. T. E. Tynan, General Manager - Plant Vogtle RType: CVC7000 U. S. Nuclear Regulatorv Commission Dr. W. D. Travers, Regional Administrator Mr. C. Gratton, NRR Project Manager - Vogtle Mr. G. J. McCoy, Senior Resident Inspector - Vogtle