L-MT-04-018, Annual Occupational Exposure Report for the Year 2003 for Monticello Nuclear Generating Plant

From kanterella
(Redirected from ML052010293)
Jump to navigation Jump to search
Annual Occupational Exposure Report for the Year 2003 for Monticello Nuclear Generating Plant
ML052010293
Person / Time
Site: Monticello 
Issue date: 03/12/2004
From: Thomas J. Palmisano
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Davis J, NRR/DRIP/RLEP, 415-3835
References
L-MT-04-018
Download: ML052010293 (5)


Text

.I b' C Tf In

^

Committed to NudearEx J'

March 12, 2004 Monticello Nuclear Generating Plant Operated by Nuclear Management Company. LLC L-MT-04-01 8 Technical Specification 6.7.A.2 US Nuclear Regulatory Commission A1TN: Document Control Desk Washington, DC 20555 Monticello Nuclear Generating Plant Docket 50-263 License No. DPR-22 Submittal of Annual Occupational Radiation Exposure Renort For the Year 2003 In accordance with Monticello Technical Specification Section 6.7.A.2, attached is the Annual Occupational Radiation Exposure Report for the Year 2003 for the Monticello Nuclear Generation Plant.

Please contact John Fields at (763) 295-1663 if you require additional information regarding this report.

Thomas J. Palmisano Site Vice President, Monticello Nuclear Power Plant Nuclear Management Company, LLC Enclosure cc:

Administrator, Region IlIl, USNRC Project Manager, Monticello, USNRC Resident Inspector, Monticello, USNRC cii3 t(

2807 West County Road 75

  • Monticello, Minnesota 55362-9637 Telephone: 763-295-5151
  • Fax: 763-295-1454

ENCLOSURE I ANNUAL OCCUPATIONAL EXPOSURE REPORT FOR THE YEAR 2003 3 pages follow

Annual Occupational Exposure Report for the Year 2003 Monticello Nuclear Generating Plant Number of Personnel and Man-Rem by Work and Cob Functions Number of Persons >.100 Rem Total Man-Rem Work and Job Function Station Utility Contract Station Utility Contract Inservice Inspection Maintenance Person.

Operating Personnel Health-Physics Per.

Supervisory Person.

Engineering Person.

3 2

2 0

56 26 0

O a

o 1o o

O.OD4 O.OD6 0.007 0.0DO 0.141 0.408 0.000 0.000 0.000

- 0.. 000 0.794 0.000 O.014

0. 000 2.206 Routine Maintenance Maintenance Person.

62 operating Personnel 33 Health Physics Per.

24 Supervisory Person.

11 Engineering Person.

24 Reactor Operations & Surv Maintenance Person.

37 Operating Personnel 40 Health Physics Per.

17 Supervisory Person.

10 Engineering Person.

19 Refueling Maintenance Person.

3 Operating Personnel 33 Health Physics Per.

6 Supervisory Person.

1 Engineering Person.

2 Special Maintenance Maintenance Person.

7 Operating Personnel 0

Health Physics Per.

6 Supervisory Person.

1 Engineering Person.

2 Waste Processing Maintenance Person.

32 Operating Personnel 20 Health Physics Per.

13 Supervisory Person.

1 Engineering Person.

2 172 0

0 0

0 43

.0 0

0 0

94 0

14 3.

7 17 0

2 3

3 8

8 0

0 0

2 0

0 0

0 38 14 0

0 0

0 0

1 0

.1 21 5

0 0

0 1

0 0

0 0

23.585 0.763 5.078

' 2.176 3.565 0.925 14.278 1.525 1.159 3.152 0.015 0.812 0.092 0.023

0. 090 0.087
0. 000 0.021 0.012 0.019 2.447 0.733 1.103 0.017 0.025
48. 684 0.000 0.000 0.000 0.000 1.305 O.ODO 0.OD0 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.990
0. 000
0. 000 0.000 0.000 1.150 0.000 0O.000
0. 000
0. 000 26.092
0. 000 5.504 0.463 0.357 0.501 0.000 0.036 0.055 0.338 0.278 0.000 0.041 0.000 0.000 0.269 0.000 0O.000 O.OD2 0.001 2.593 0.000
  • 0.016 0.000 0.000 I

Annual Occupational Exposure Report for the Year 2003 Monticello Nuclear Generating Plant Number of Personnel and Man-Rem by Work and Job Functions Number of Persons >.100 Rem Total Man-Rem Work and Job Function Station Utility Contract Station Utility Contract

____________________________________To___________________a____________________

.Sub Totals Maintenance Person.

Operating Personnel Health Physics Per.

Supervisory Person.

Engineering Person.

Grand Totals 144 128 68 24 50 338 0

0 0

164 0

20 7

27.063 16.592 7.826 3.387 6.992 61.860 52.581 0.000 0.000 0.000 0.000 52.581 30.527 0.000 5.611 0.520 2.902 39.560 0

18 414 338 209 Total Site Deep Dose (NDE + DDE) for Ind. with >.100 rem.

153.767 rem

    • INDIVIDUALS MAY BE LISTED UNDER MORE THAN ONE WORK AND JOB FUNCTION Special Maintenance Items:

Total Man-Rem

-Refueling Outage

-Fuel Pool Clean Up Project

-Fire Watch 120.0 6.6 1.5 2

I
  • 2

.:1

.Annual Occupational Exposure Report for the Year 2003 Monticello Nuclear Generating Plant Number of Personnel and Man-Rem by Work and Cob Functions Deep Dose Exposure Range Number of Individuals in Range None -

Detected Less then.100 rem 0.100 rem to 0.249 rem 0.250 rem to 0.499 rem 0.500 rem to 0.749 rem 0.750 rem to 0.999 rem 1.000 rem to 1.999 rem Greater then 2.000 rem Total Monitored Individuals 701 402 209 158 60 21 8

0 1559 Total Site Deep Dose (NDE + DDE) -

168.889 rem r,

3