CNRO-2005-00029, Request IST-2005-1 Use of Subsequent ASME OM Code Edition and Addenda for Condition Monitoring of Check Valves
| ML051600328 | |
| Person / Time | |
|---|---|
| Site: | Grand Gulf, Arkansas Nuclear, River Bend, Waterford |
| Issue date: | 06/03/2005 |
| From: | Burford F Entergy Operations |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| CNRO-2005-00029 | |
| Download: ML051600328 (5) | |
Text
-- Entergy Entergy Operations, Inc.
1340 Echelon Parkway Jackson, Mississippi 39213-8298 Tel 601-368-5758 F. G. Burford Acting Director Nuclear Safety & Licensing CNRO-2005-00029 June 3, 2005 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001
SUBJECT:
Request IST-2005-1 Use of Subsequent ASME OM Code Edition and Addenda for Condition Monitoring of Check Valves Arkansas Nuclear One, Units 1 and 2 Docket No. 50-313 License No. DPR-51 River Bend Station Docket No. 50-458 License No. NPF-47 Grand Gulf Nuclear Station Docket No. 50-416 License No. NPF-29 Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38
Dear Sir or Madam:
Pursuant to 10 CFR 50.55a(f)(4)(iv), Entergy Operations, Inc. (Entergy) requests permission to use Paragraph ISTC-5222 of the ASME Operation and Maintenance (OM) Code 2001 Edition through the 2003 Addenda at Arkansas Nuclear One - Units 1 and 2, Grand Gulf Nuclear Station, River Bend Station, and Waterford Steam Electric Station, Unit 3. Paragraph ISTC-5222 provides requirements for monitoring check valves using a condition monitoring program. Request IST-2005-1 is provided in the enclosure.
Entergy is providing Request IST-2005-1 in accordance with NRC Regulatory Issue Summary 2004-12, Clarification on Use of Later Editions and Addenda to the ASME OM Code and Section Xl. This request is based on the guidance provided in NUREG-1 482, Rev. 1, Guidelines for Inservice Testing at Nuclear Power Plants.
Entergy requests approval of Request IST-2005-1 by September 15, 2005 in order to support the upcoming refueling outage at Grand Gulf Nuclear Station. Should you have any questions regarding this submittal, please contact Guy Davant at (601) 368-5756.
.0/41S
CNRO-2005-00029 Page 2 of 2 This letter contains no commitments.
Very truly yours, FGBIGHD/ghd
Enclosure:
Request IST-2005-1 cc:
Mr. W. A. Eaton (ECH)
Mr. J. P. DeRoy (ECH)
Mr. J. S. Forbes (ANO)
Mr. P. D. Hinnenkamp (RBS)
Mr. J. E. Venable (W3)
Mr. G. A. Williams (GG)
Dr. Bruce S. Mallett Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Arkansas Nuclear One P. O. Box 310 London, AR 72847 NRC Senior Resident Inspector Grand Gulf Nuclear Station Route 2, Box 399 Port Gibson, MS 39150 NRC Senior Resident Inspector River Bend Station P. 0. Box 1050 St. Francisville, LA 70775 NRC Senior Resident Inspector Waterford Steam Electric Station, Unit 3 P. 0. Box 822 Killona, LA 70066-0751 U. S. Nuclear Regulatory Commission Attn: Mr. T. W. Alexion (ANO-1)
MS 0-7D1 Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Attn: Mr. D. G. Holland (ANO-2)
MS 0-7D1 Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Attn: Mr. B. K. Vaidya (GGNS)
MS O-7D1 Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Attn: Mr. M. K. Webb (RBS)
MS O-7D1 Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Attn: Mr. N. Kalyanam (W3)
MS O-7D1 Washington, DC 20555-0001
ENCLOSURE CNRO-2005-00029 Request IST-2005-1 Request In Accordance with 10 CFR 50.55a(f)(4)(iv) for IST Items
p-ENTERGY OPERATIONS, INC.
10 CFR 50.55a Request IST-2005-1 Request in Accordance with 10 CFR 50.55a(f)(4)(iv) for IST Items
- 1. ASME Code Components Affected All check valves within the Inservice Testing (IST) program.
2. Applicable Code Edition and Addenda
Currently, Arkansas Nuclear One - Units 1 and 2, Grand Gulf Nuclear Station, River Bend Station, and Waterford Steam Electric Station, Unit 3 are committed to ASME/ANSI OM-1 Oa, 1988 Edition. The next 120-month interval for Arkansas Nuclear One - Unit 1, Grand Gulf Nuclear Station, River Bend Station, and Waterford Steam Electric Station, Unit 3 starts December 2007. The next 120-month interval for Arkansas Nuclear One -
Unit 2 starts December 2009.
- 3. Proposed Subsequent Code Edition and Addenda (or Portion)
Pursuant to 10 CFR 50.55a(f)(4)(iv), Entergy Operations, Inc. (Entergy) requests permission to use Paragraph ISTC-5222 of the 2001 Edition with 2003 Addenda of ASME Operation and Maintenance (OM) Code for the conduct of check valve monitoring at Arkansas Nuclear One - Units 1 and 2, Grand Gulf Nuclear Station, River Bend Station, and Waterford Steam Electric Station, Unit 3.
Paragraph ISTC-5222 states:
"As an alternative to the testing and examination requirements of ASME Operation and Maintenance (OM) Code Sections ISTC-3510, ISTC-3520, ISTC-3540, and ISTC-5221, the Owner may establish a condition-monitoring program. The purpose of this program is both to improve check valve performance and to optimize testing, examination, and preventive maintenance activities in order to maintain the continued acceptable performance of a select group of check valves. The Owner may implement this program on a valve or a group of similar valves. The program shall be implemented in accordance with Mandatory Appendix II, Check Valve Condition Monitoring Program. If the condition-monitoring program for a valve or valve group is discontinued, then the testing or examination requirements of ISTC-351 0, ISTC-3520, ISTC-3540, and ISTC-5221 shall apply."
- 4. Related Requirements There are no related requirements. The NRC approved the use of Appendix II condition monitoring program requirements specified in the 2001 Edition and 2003 Addenda with no limitations or modifications as documented in 10 CFR 50.55a(b)(3)(iv). In Federal Register 69 FR 58814, the NRC stated in part, "The modifications in (b)(3)(iv) does not apply to the 2003 Addenda of the ASME OM Code because the earlier Code provisions on which this regulation was based were revised in the 2003 Addenda of the ASME OM 1 of 2
Code to address the underlying issues which led to the NRC to impose the modification.
The check valve monitoring program requirements in Appendix 11 of the 2003 Addenda of the ASME OM Code are equivalent to the check valve monitoring program requirements in § 50.55a(b)(3)(iv)."
- 5. Duration of Proposed Request Entergy plans to begin implementing the Appendix 11 condition monitoring program upon approval of this request. This request will remain in effect until the start of the next 120-month interval for each site, as identified in Item 2, above. This schedule will allow sufficient time to establish the process and procedures, and evaluate groupings, which are necessary to implement the program requirements.
2 of 2