CNRO-2004-00072, Request No. CEP-IWE/IWL-001 Use of Subsequent ASME Code Edition and Addenda for Visual Containment Examinations
| ML043080325 | |
| Person / Time | |
|---|---|
| Site: | Grand Gulf, Arkansas Nuclear, River Bend, Waterford |
| Issue date: | 10/27/2004 |
| From: | Burford F Entergy Operations |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| CEP-IWE/WL-001, CNRO-2004-00072 | |
| Download: ML043080325 (8) | |
Text
Entergy Operations, Inc.
1340 Echelon Parkway I 1661
- vJackson, Mississippi 39213-8298 E
eTel 601-368-5758 F. G. Burford Acting Director Nuclear Safety & Licensing CNRO-2004-00072 October 27, 2004 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001
SUBJECT:
Request No. CEP-IWE/IWL-001 Use of Subsequent ASME Code Edition and Addenda for Visual Containment Examinations River Bend Station Docket No. 50-458 License No. NPF-47 Grand Gulf Nuclear Station, Unit 1 Docket No. 50-416 License No. NPF-29 Arkansas Nuclear One, Unit 1 and 2 Docket Nos. 50-313 and 50-368 License Nos. DPR-51 and NPR-6 Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38
Dear Sir or Madam:
Pursuant to 10 CFR 50.55a(g)(4)(iv), Entergy Operations, Inc. (Entergy) requests permission to use portions of the 1998 edition with 1999 and 2000 addenda of ASME Section Xi for the conduct of visual containment examinations. Request CEP-IWE/IWL-001 (see enclosed) applies to Arkansas Nuclear One Units 1 and 2, Grand Gulf Nuclear Station, River Bend Station, and Waterford 3 Steam Electric Station. This request is based on recent guidance provided in Regulatory Information Summary 2004-12.
Entergy requests approval of the proposed amendment by 1/15/2005 in order to support the Arkansas Nuclear One, Unit 2 and Waterford Steam Electric Station, Unit 3 outages scheduled for March and April of 2005.
CNRO-2004-00072 Page 2 of 3 Should you have any questions regarding this submittal, please contact Bill Brice at (601) 368-5076.
This letter contains no commitments.
Very truly yours, FGBIWBB/bal
Enclosure:
Request No. CEP-IWE/IWL-001 cc:
(see next page)
CNRO-2004-00072 Page 3 of 3 cc:
Mr. W. A. Eaton (ECH)
Mr. J. P. DeRoy (ECH)
Mr. J. S. Forbes (ANO)
Mr. P. D. Hinnenkamp (RBS)
Mr. J. E. Venable (W3)
Mr. G. A. Williams (GG)
Dr. Bruce S. Mallett U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 U. S. Nuclear Regulatory Commission Attn: Mr. Thomas W. Alexion MS 0-7 D1 Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Attn: Mr. Drew Holland MS 0-7 D1 Washington, DC 20555-0001 U.S. Nuclear Regulatory Commission Attn: Mr. Nageswaran Kalyanam MS O-7D1 Washington, DC 20555-0001 U. S. Nuclear Regulatory Commission Attn: Mr. Bhalchandra Vaidya MS 0-7D1 Washington, DC 20555-0001 U.S. Nuclear Regulatory Commission Attn: Mr. Michael K. Webb MS 0-7D1 Washington, DC 20555-0001 NRC Senior Resident Inspector Arkansas Nuclear One P.O. Box310 London, AR 72847 NRC Senior Resident Inspector Grand Gulf Nuclear Station Route 2 Box 399 Port Gibson, MR 39150 NRC Senior Resident Inspector Waterford 3 P.O. Box 822 Killona, LA 70066-0751 NRC Senior Resident Inspector River Bend Station P. 0. Box 1050 St. Francisville, LA 70775
ENCLOSURE CNRO-2004-00072 CEP-IWE/IWL-001
10 CFR 50.55a Request Number CEP-IWE/IWL-001 Proposed Use of Subsequent ASME Code Edition and Addenda for Visual Containment Examinations at Arkansas Nuclear One, Units 1 and 2, Grand Gulf Nuclear Station, River Bend Station, and Waterford 3 Steam Electric Station In accordance with RIS 2004-12 and 10 CFR 50.55a (g)(4)(iv), Entergy Operations, Inc.
(Entergy) requests permission to use the 1998 edition with 1999 and 2000 addenda of ASME Section Xl for the conduct of containment examinations at Arkansas Nuclear One, Units I and 2, Grand Gulf Nuclear Station, River Bend Station, and Waterford 3 Steam Electric Station as detailed below.
- 1. ASME Code Components Affected:
Class MC Components, Liners of Class CC Containments, and Class CC components examined in the following ASME examination categories and item numbers:
Category Item Numbers (1992 Edition and Addenda)
(per 1992 Edition and Addenda)
E-A E1.11, E1.12 E-C E4.11, E4.12 L-A I1.11, L1.12 L-B L2.30
- 2. Applicable Code Edition and Addenda (Code of Record) 1992 Edition with 1992 Addenda of ASME Section Xl, Subsections IWE and IWL and including approved requests for relief, requests for alternatives, and modifications set forth in 10 CFR 50.55a.'
- 3. Proposed Subsequent Code Edition and Addenda Entergy proposes adoption of the sections of the 1998 Edition with 1999 and 2000 Addenda of ASME Section XI, Subsection IWE and IWL, shown in the following table, as approved in 10 CFR 50.55a (b)(2)(viii) and 10 CFR 50.55a (b)(2)(ix) including related paragraphs of ASME Code, approved requests for relief, requests for alternatives, and modifications set forth in 10 CFR 50.55a as described below (67 FR 60520).
For the ASME item numbers identified in Section 1 of this submittal, examinations, including examinations required for repair or replacement, will be conducted as required under the proposed code as listed in the following table for the affected item number. Paragraphs of the later edition and addenda of code that will be applied to the program as a whole, regardless of the item number of the component, are listed as 'Additional paragraphs from the 1998 Edition with 1999 and 2000 addenda being adopted".
Page 1 of 4
1992 Code 1998 Code.
Particular Paragraphs from 1998 Edition with 1999 Item Number Item Number.
and 2000 Addenda" E1.11 and E1.11 IWE-1231; IWE-1232; IWE-2100; IWE-2200; IWE-E1.12 2300; IWE-2420; IWE-2500, IWE-2600, IWE-3100; IWE-3200; IWE-3400; IWE-3510.1; IWE-3510.2; Table IWE-2500-1 Category E-A Item E1.11 E1.12 IWA-2200(a); IWA-2200(b); IWA-2210; IWA-2213; IWA-2215; IWA-2240; IWA-2300; IWE-1231; IWE-1232; IWE-2200; IWE-2320; IWE-2420;IWE-2500, IWE-2600, IWE-3100; IWE-3200; IWE-3400; IWE-3510.1; IWE-3510.2; Table IWA-221 0-1; Table IWE-2500-1 Category E-A Item E1.12 E4.11 E4.11 IWA-2200(a); IWA-2200(b); IWA-2210; IWA-2211; IWA-2215; IWA-2240; IWA-2300; IWE-1231; IWE-1232; IWE-1241; IWE-1242; IWE-2200; IWE-2420; IWE-2500; IWE-2600; IWE-3100; IWE-3200; IWE-3400; IWE-3511.1; IWE-3511.2; Table IWA-2210-1; Table IWE-2500-1 Category E-C Item E4.11 E4.12 E4.12 IWA-2200(a); IWA-2200(b); IWA-2230; IWA-2232; IWA-2240; IWA-2300; IWE-1231; IWE-1232; IWE-'
1241; IWE-1242; IWE-2200; IWE-2420; IWE-2500; IWE-2600; IWE-3100; IWE-3200; IWE-3400; IWE-3511.3; Table IWE-2500-1 Category E-C Item E4.12; Table IWE-2500-2 L1.11 L1.11 IWA-2200(a); IWA-2200(b); IWA-2210; 1WA-2240; IWA-2300; IWL-2230; IWL-231 0(a)-(c) and (e) II; IWL-2410; IWL-2510; IWL-3111; IWL-3112; IWL-3113; IWL-3211; IWL-3212; IWL-3213; IWL-4220(c); IWL-5250; Table IWL-2500-1 Category L-A Item L1.11 L1.12 L1.12 IWA-2200(a); IWA-2200(b); IWA-2210; IWA-2240; IWA-2300; IWL-2230; IWL-2310(a)-(c) and (e)IV; IWL-2410;IWL-2510; IWL-3111; IWL-3112; IWL-3113; IWL-3211; IWL-3212; IWL-3213; IWL-4220(c); IWL-5250; Table IWL-2500-1 Category L-A Item L1.12 L2.30 L2.30 IWA-2200(a); IWA-2200(b); IWA-221 0; IWA-221 1; IWA-2215; IWA-2240; IWA-2300; IWL-2230; IWL-2310(a)-(c) and (e); IWL-2524.1; IWL-3221.3; IWL-3222; IWL-3223; IWL-4220(c); IWL-5250; Table IWL-2500-1 Category L-B Item L2.30 Page 2of 4
1992 Code l
1998 Code Particular Paraqraphs from 1998 Edition with 1999 Item Number I Item Number and 2000 Addenda" Additional paragraphs from the IWE-2500 (references to Table IWE-2500-1 will 1998 Edition with 1999 and refer to the code of record unless specifically listed 2000 addenda being adopted.
above.); IWE-5000; IWL-2320; IWL-3300; IWL-4220 (replaces IWL-4210 from the code of record);
IWL 5250
- 4. Related Requirements 10 CFR 50.55a (b)(2)(viii) states in part, "Licensees applying the 1998 Edition with the 1999 and 2000 Addenda shall apply paragraphs (b)(2)(viii)(E) and (b)(2)(viii)(F) of this section."
These paragraphs will be implemented for the code paragraphs listed in Section 3.
10 CFR 50.55a (b)(2)(ix) states in part, "Licensees applying the 1998 Edition through the latest edition and addenda incorporated by reference in paragraph (b)(2) of this section, shall satisfy the requirements of paragraphs (b)(2)(ix)(A), (b)(2)(ix)(B), and (b)(2)(ix)(F) through (b)(2)(ix)(1) of this section." These paragraphs will be implemented for the code paragraphs listed in Section 3.
The table in Section 3 above lists the paragraphs containing the primary requirements and related requirements of the 1998 code with 1999 and 2000 addenda as modified by 10 CFR 50.55a. The code of record will continue to be used for paragraphs not listed in the table as well as for inspections of ASME items not listed in this table.
- 5. Duration of Proposed Request This request will continue to be valid until the next 10 year update of the containment inservice inspection program at each site.
Page 3 of 4
End Notes:
SERs for current approved requests for relief and requests for alternative affecting the Containment Inservice Inspection Program may be found in letters from the NRC to Mr. Randy Hutchinson dated 5-11-1999 and 6-2-1999 from the NRC to Mr. Michael Kansler dated 1-13-2000, and from the NRC to Mr. William Eaton Dated 10-5-2000.
These requests allow the use of remote inspection techniques for completion of IWL examinations, use of general visual and detailed visual concrete examinations in lieu of VT-3C and VT-1 C examinations, and use of Appendix J pressure tests as an alternative for visual examination of seals and gaskets. Additionally the requests provide relief from requirements for re-examination of repaired or replaced components (pre-service examination is still required),
and relief from requirements for bolt torque and tension examinations.
" Where IOCFR50.55a limits the use of owner defined requirements or specifies use of VT-1 or VT-3 examination in lieu of general or detailed visual examinations, the appropriate paragraphs of IWA are listed to allow adoption of the IOCFR50.55a modifications and limitations.
INVL-2310(d) is not being adopted because of the specific restriction on it's use in IOCFR50.55a(b)(2)(viii)(F).
iv IWL-2310(d) is not being adopted because of the specific restriction on it's use in IOCFR50.55a(b)(2)(viii)(F).
Page 4 of 4