I N. Kalv Kalvanam - W3 CEDM Nozzle Freest)an Lenaths Page 1 I N. KaIv Kalvanam - W3 CEDM Nozzle Freespan Lenaths Pacie ii From:
"DAVANT, GUY H <GDAVANT@entergy.com>
To:
"'Katy" <nxk6nrc.gov>
Date:
11/4/03 10:44AM d
V O.3b-'Z
Subject:
W3 CEDM Nozzle Freespan Lengths Kaly,.'
Attached is a table that documents the actual as-built freespan lengths of the Waterford 3 CEDM nozzles. These lengths were determined from the UT scan data. In Entergy letter CNRO-2003-00057, dated 10/24/03, Entergy responded to an NRC question pertaining to reanalysis criterion. In that letter, Entergy provided the amount of freespan length, designated as "minimum propagation length", required for each nozzle group. A nozzle with less freespan length than the designated miminum propagation length would require augmented inspection. As can be seen from the attached table, the actual as-built freespan lengths of the CEDM nozzles exceed the minimum propagation lengths. Therefore, no augmented inspections of the CEDM nozzles were required. Please let me know if you have any questions about this information.
Thanks!
Guy CC:
"KRUPA, MICHAEL A" <MKRUPA~entergy.com>, 'BURFORD, FRANCIS G"
<FBURFOR@entergy.com>, "LEWIS, RAYMOND S <RLEWIS1 @entergy.com>, SWAIN, RONALD VANCE <RSWAIN1 @entergy.com>, "SIMS, WILLIAM D0 <WSIMS@entergy.com>, "JAMES, WILLIAM"
<WJAMES1 @entergy.com>, "BENNETT, STEVE A" <SBENNE2@entergy.com>, "PAYNE, GARY - WF3"
<GPAYNE@entergy.com>, "HOUGHTALING, JOHN B" <JHOUGHT@entergy.com>, "MANZELLA, JUSTINE M' <JMANZEL~entergy.com>
WATERFORD 3
~-~2 S4V
..Low Hillside Nozzle Head Angle Axial Weld Ht.
Freespan length l_
ll (degrees)
(inches)
(inches) 1 0.0 0.920 1.000 2
7.8 0.880 1.080 3
7.8 1.400 0.920 4
11.0 1.200 1.040 5
11.0 1.480 1.000 6
11.0 1.320 1.080 7
11.0 0.960 1.040 8
15.6 1.600 0.840 9
15.6 1.280 1.000 10 15.6 1.160 1.000 11 15.6 1.160 0.760 12 17.5 1.680 0.720 13 17.5 1.320 1.080 14 17.5 1.480 1.080 15 17.5 0.920 1.160 16 17.5 1.160 1.080 17 17.5 1.400 0.880 18 17.5 1.480 0.960 19 17.5 0.920 1.080 20 22.4 1.600 0.720 21 22.4 1.520 0.880 22 22.4 1.480 0.840 23 22.4 1.400 0.880 24 23.9 1.240 0.880 25 23.9 1.560 0.880 26 23.9 1.720 0.720 27 23.9 1.440 0.800 28 25.2 1.320 0.840 29 25.2 1.560 0.760 30 25.2 1.520 0.800 31 25.2 1.400 0.840 32 25.2 1.560 0.880 33 25.2 1.320 1.080 34 25.2 1.640 0.760 35 25.2 1.320 0.680 36 29.1 1.480 0.720 37 29.1 1.600 0.800 38 29.1 1.640 0.720 39 29.1 1.480 0.760 40 29.1 1.320 0.760 41 29.1 1.480 0.960 Page 1 of 3
WATERFORD 3
'$4---
42 29.1 1.240 0.920 43 29.1 1.680 -
0.680 44 32.7 1.520 0.760 45 32.7 1.480 0.840 46 32.7 1.720 0.680 47 32.7 1.560 0.680 48 33.8 1.600 0.680 49 33.8 1.560 0.720 50 33.8 1.440 0.880 51 33.8 1.360 0.720 52 33.8 1.520 0.840 53 33.8 1.240 0.880 54 33.8 1.860 0.300 55 33.8 1.600 0.600 56 34.9 1.680 0.560 57 34.9 1.680 0.760 58 34.9 1.760 0.720 59 34.9 1.280 0.840 60 37.1 1.680 0.600 61 37.1 1.520 0.680 62 37.1 1.560 0.840 63 37.1 1.720 0.720 64 37.1 1.680 0.520 65 37.1 1.640 0.560 66 37.1 1.760 0.440 67 37.1 1.600 0.480 68 42.4 1.840 0.560 69 42.4 1.640 0.600 70 42.4 1.960 0.560 71 42.4 1.840 0.760 72 42.4 1.840 0.480 73 42.4 2.000 0.520 74 42.4 2.200 0.360 75 42.4 2.000 0.560 76 42.4 1.520 0.600 77 42.4 1.560 0.560 78 42.4 1.920 0.440 79 42.4 2.000 0.280 80 43.4 1.880 0.520 81 43.4 1.440 0.840 82 43.4 1.800 0.560 83 43.4 1.520 0.840 84 43.4 1.800 0.640 85 43.4 1.800 0.560 1I I
I_
Page 2 of 3
4,
WATERFORD 3 86 43.4 1.960 0.280 87 43.4 2.200 0.240 88 49.7 2.080 0.520 89 49.7 2.120 0.320 90 49.7 2.320 0.520 91 49.7 2.240 0.320 Page 3 of 3