PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 DEC 1 8 2002 o PSEG Nuclear LLC LR-N02-0416 LCR H02-001 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Gentlemen:
HOPE CREEK GENERATING STATION - REQUEST FOR ADDITIONAL INFORMATION REGARDING RELAXATION OF SECONDARY CONTAINMENT OPERABILITY REQUIREMENTS AND ELIMINATION OF FRVS RECIRCULATION CHARCOAL FILTERS FACILITY OPERATING LICENSE NPF-67 DOCKET NO. 50-354
Reference:
Letter LR-N02-0002, Request For Change To Technical Specifications Relaxation Of Secondary Containment Operability Requirements And Elimination Of FRVS Recirculation Charcoal Filters, dated June 28, 2002 On June 28, 2002 PSEG Nuclear LLC (PSEG) submitted the referenced request for a revision to the Technical Specifications (TS) to Hope Creek Generating Station. Mr.
George Wunder, NRC Hope Creek Project Manager, requested that both the LOCA and Fuel Handling Accident Analysis RADTRAD computer files be docketed. He also requested copies of the analyses. The analyses were included as Attachments 3 and 4 to the referenced submittal. The enclosure to this letter is a CD-ROM containing the requested RADTRAD computer files associated with the analyses.
If you have any questions or require additional information, please contact Mr. Michael Mosier at (856) 339-5434.
Manager - Nuclear Safety and Enclosure
- o0 95-2168 REV. 7199
Document Control Desk LR-N02-0416 LCR H02-01 DEC 1 8 2002 C:
Mr. H. Miller, Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. George Wunder, Project Manager - Hope Creek U. S. Nuclear Regulatory Commission Mail Stop 08B3 Washington, DC 20555-0001 USNRC Senior Resident Inspector - Hope Creek (X24)
Mr. K. Tosch, Manager IV Bureau of Nuclear Engineering PO Box 415 Trenton, New Jersey 08625 2