ENS 54687: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 9: Line 9:
| unit = 2
| unit = 2
| utype = W-4-LP, W-4-LP
| utype = W-4-LP, W-4-LP
| cfr = 10 CFR 50.72(b)(2)(i), 10 CFR 50.72(b)(3)(ii)(A)
| cfr = 10 CFR 50.72(b)(2)(i)
| emergency class = Non Emergency  
| emergency class = Non Emergency
| notification date = 05/01/2020 11:53
| notification date = 05/01/2020 11:53
| notification by = Rodney Pickard
| notification by = Rodney Pickard
| NRC officer = Donald Norwood
| NRC officer = Donald Norwood
| event date = 05/01/2020 03:54 EDT
| event date = 05/01/2020 03:54 EDT
| last update date = 05/01/2020
| last update date = 05/15/2020
| title = Technical Specification Required Shutdown Due to Reactor Coolant System Pressure Boundary Leakage
| title = Technical Specification Required Shutdown Due to Reactor Coolant System Pressure Boundary Leakage
| event text = At 1000 EDT on May 1 2020, Operations commenced a shutdown of DC Cook Unit 2 to comply with LCO 3.4.13, Condition B Reactor Coolant System (RCS) pressure boundary leakage.
| event text = At 1000 EDT on May 1 2020, Operations commenced a shutdown of DC Cook Unit 2 to comply with LCO 3.4.13, Condition B Reactor Coolant System (RCS) pressure boundary leakage.
Line 24: Line 24:
At 1059 EDT on May 1, Unit 2 was tripped from 15 percent power. All systems functioned normally.
At 1059 EDT on May 1, Unit 2 was tripped from 15 percent power. All systems functioned normally.
This event is reportable under 10 CFR 50.72(b)(2)(i), the initiation of any nuclear plant shutdown required by the plant's Technical Specifications as a 4-hour report and under 10 CFR 50.72 (b)(3)(ii)(A), degraded condition, as an 8-hour report. The NRC Resident Inspector has been notified.
This event is reportable under 10 CFR 50.72(b)(2)(i), the initiation of any nuclear plant shutdown required by the plant's Technical Specifications as a 4-hour report and under 10 CFR 50.72 (b)(3)(ii)(A), degraded condition, as an 8-hour report. The NRC Resident Inspector has been notified.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200504en.html#en54687
* * * PARTIAL RETRACTION ON 5/15/2020 AT 1442 EDT FROM BUD HINCKLEY TO THOMAS HERRITY * * *
}}{{unit info
The condition identified in EN #54687, pursuant to 10 CFR 50.72 (b)(3)(ii)(a) has been evaluated, and has been determined not to be RCS pressure boundary leakage. As such, the 8-hour report is being retracted, as it is not an event or condition that results in, 'the condition of the nuclear power plant, including its principal safety barriers, being seriously degraded.'
| Unit =  2
The leakage was subsequently determined to be from the tell-tale nipple of a pressurizer spray valve, not from the pressurizer spray line piping as previously reported. The Reactor Coolant Pressure Boundary (RCPB) is formed by the valve body, plug, seat, body to bonnet extension, and bonnet of the pressurizer spray valve. Therefore, the leakage is not RCPB leakage.
| type =
There is no change to the 4-hour report made under 10 CFR 50.72(b)(2)(i), the initiation of any nuclear plant shutdown required by the plant's Technical Specifications.
| Scram code =  N
The NRC Resident Inspector was notified of this retraction.
| Reactor critical =  Y
Notified R3DO (Stone).
| Initial power =  100
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200518en.html#en54687
| Initial reactor mode =  Power Operation
| Current power =  0
| Current reactor mode =  Hot Standby
}}
}}


{{ENS-Nav}}[[Category:Power Reactor]]
{{ENS-Nav}}[[Category:Power Reactor]]

Latest revision as of 12:38, 15 January 2021

ENS 54687 +/-
Where
Cook American Electric Power icon.png
Michigan (NRC Region 3)
Reporting
10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown
Time - Person (Reporting Time:+3.98 h0.166 days <br />0.0237 weeks <br />0.00545 months <br />)
Opened: Rodney Pickard
11:53 May 1, 2020
NRC Officer: Donald Norwood
Last Updated: May 15, 2020
54687 - NRC Website