ENS 53924
ENS Event | |
---|---|
12:51 Mar 11, 2019 | |
Title | Planned Communication System Maintenance |
Event Description | On 03/11/2019 planned maintenance activities will be performed on the Beaver Valley Power Station (BVPS) Unit 2 Digital Radiation Monitoring System's (DRMS) Communications System.
The work includes upgrades to the DRMS hardware, software and computer peripherals. Components to be upgraded under this planned maintenance include: Redundant Servers, Operator Console, Health Physics Office Console/Workstation, Printers and Portable Mass Storage/Backup and Computer peripherals necessary to interface with the computer system. This planned upgrade on the Unit 2 DRMS Communications System will result in the loss of Unit 2 radiological monitoring capability in the Control Room and on the Plant Computer System (PCS). Neither the Emergency Response Facilities nor the Emergency Response Data System (ERDS) will receive radiological data. No actual radiation monitors are affected. The scheduled work duration is approximately three weeks. When the DRMS is out of service for the upgrade, compensatory actions will be in place. Radiation monitors will be continuously monitored for any increases in radiation levels. The Unit 2 Shift Manager will be notified of any increase in radiation monitor readings, including exceeding Emergency Action Levels (EAL). This is an eight-hour, non-emergency notification for a Loss of Emergency Assessment Capability. This event is reportable in accordance with 10 CFR 50.72(b)(3)(xiii) because the upgrade to the DRMS Communications System will result in the loss of the Unit 2 radiological monitoring capability in the Control Room and to the Unit 2 Plant Computer System that affects the functionality of an Emergency Response Facility. There is no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified. The licensee is currently in a Technical Specification Action Statement, Limiting Condition for Operation for spent fuel pool radiation monitor and leakage rate monitor. |
Where | |
---|---|
Beaver Valley Pennsylvania (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
Time - Person (Reporting Time:+-2.85 h-0.119 days <br />-0.017 weeks <br />-0.0039 months <br />) | |
Opened: | Dan Schwer 10:00 Mar 11, 2019 |
NRC Officer: | Jeffrey Whited |
Last Updated: | Mar 11, 2019 |
53924 - NRC Website | |
Unit 2 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
WEEKMONTHYEARENS 539242019-03-11T12:51:00011 March 2019 12:51:00
[Table view]10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Communication System Maintenance ENS 510642015-05-11T20:29:00011 May 2015 20:29:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power to Digital Radiation Monitoring System ENS 508952015-03-14T21:08:00014 March 2015 21:08:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Failed ENS 506272014-11-19T14:43:00019 November 2014 14:43:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Eal Required Gaseous Waste Effluent Radiation Monitors Removed from Service for Planned Maintenance ENS 504172014-08-29T13:32:00029 August 2014 13:32:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Operating Intermittently ENS 497162014-01-11T21:05:00011 January 2014 21:05:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Communication Failure ENS 491582013-06-29T16:14:00029 June 2013 16:14:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Operating Intermittently ENS 475132011-12-05T14:45:0005 December 2011 14:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Unavailability of Emergency Response Data System (Erds) for Scheduled Upgrade ENS 462322010-09-07T14:43:0007 September 2010 14:43:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Plant In-Process Computer Oos for Maintenance ENS 456832010-02-06T14:28:0006 February 2010 14:28:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Siren Capability Due to Adverse Weather Conditions ENS 450232009-04-26T19:45:00026 April 2009 19:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Erds and Plant Computer Unavailable During Maintenance on Computer Room Cooling ENS 444872008-09-15T12:00:00015 September 2008 12:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Sirens Due to Power Outages Caused by High Winds ENS 434582007-06-29T04:14:00029 June 2007 04:14:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Radiation Monitoring Information to Erds and Spds Will Be Unavailable During Planned Upgrade to the System. ENS 430302006-12-03T23:04:0003 December 2006 23:04:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Non-Functional Safety Parameter Display System ENS 428022006-08-25T14:30:00025 August 2006 14:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Response Data System and Safety Parameter Display System Will Be Unavailable 2019-03-11T12:51:00 | |