ENS 46669
From kanterella
Revision as of 19:21, 24 November 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
ENS Event | |
---|---|
14:15 Mar 10, 2011 | |
Title | Malfunctioning Valve Leads to a Loss of Defense in Depth |
Event Description | During a performance of temporary operating procedure on a laser optical device, it was identified that one of two valves used to isolate the device failed to operate. The valves are operated as a pair and the valves are redundant to provide defense in depth. One valve shut as expected. The second valve did not shut.
The valves are identified as an Item Relied on For Safety (IROFS). The system was not operating and one of the valves operated as designed. No unsafe condition existed. Operability of both valves is required to meet the performance requirements of 10CFR70.61. This event is being reported pursuant to the requirements of 10CFR70 Appendix A(b)(2) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The affected device will remain shutdown pending further investigation and implementation of associated corrective actions. [This event is of] low safety significance - the discovery did not result in an unsafe condition. |
Where | |
---|---|
Global Nuclear Fuel - Americas Wilmington, North Carolina (NRC Region 2) | |
License number: | SNM-1097 |
Reporting | |
Part 70 App A (B)(2) | |
Time - Person (Reporting Time:+18 h0.75 days <br />0.107 weeks <br />0.0247 months <br />) | |
Opened: | Julie Olivier 08:15 Mar 11, 2011 |
NRC Officer: | Pete Snyder |
Last Updated: | Mar 11, 2011 |
46669 - NRC Website | |
Global Nuclear Fuel with Part 70 App A (B)(2) | |
WEEKMONTHYEARENS 562562022-12-02T20:30:0002 December 2022 20:30:00
[Table view]Part 70 App A (B)(2) Fuel Cycle Facility - Loss or Degradation of Safety Items ENS 533312018-04-12T23:00:00012 April 2018 23:00:00 Part 70 App A (B)(2) Potentially Degraded Items Relied on for Safety ENS 522512016-09-19T10:00:00019 September 2016 10:00:00 Part 70 App A (B)(2) Uf6 Scrubber Exhaust System Not Operating as Required ENS 516622016-01-19T02:00:00019 January 2016 02:00:00 Part 70 App A (B)(2) Accumulation of Uranium Oxide Powder in the Dry Scrap Recycle Furnace Off-Gas System ENS 499692014-03-28T17:30:00028 March 2014 17:30:00 Part 70 App A (B)(2), Part 70 App A (A)(4) Items Relied on for Safety Not Operable ENS 480382012-06-19T21:00:00019 June 2012 21:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 480572012-02-13T13:20:00013 February 2012 13:20:00 Part 70 App A (B)(2) Mass Control Limit Exceeded ENS 466692011-03-10T14:15:00010 March 2011 14:15:00 Part 70 App A (B)(2) Malfunctioning Valve Leads to a Loss of Defense in Depth ENS 464862010-12-16T15:44:00016 December 2010 15:44:00 Part 70 App A (B)(2) Both Hf Detectors in Ghs Test Loop Failed to Be Available and Operable ENS 462442010-09-10T14:00:00010 September 2010 14:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 461682010-01-25T13:50:00025 January 2010 13:50:00 Part 70 App A (B)(2) Degradation of an Item Relied on for Safety ENS 436372007-09-12T15:30:00012 September 2007 15:30:00 Part 70 App A (B)(2) Moderation Control Item Relied on for Safety Degradation 2022-12-02T20:30:00 | |