Semantic search
Jump to navigation
Jump to search
Start date | Site | Title | |
---|---|---|---|
IR 05000336/2022401 | 26 January 2023 | Millstone | Security Baseline Inspection Report 05000336/2022401 and 05000423/2022401 and Preliminary Finding(S) of Greater than Very Low Significance and Apparent Violation(S) (Cover Letter Only) |
IR 05000456/2022010 | 22 June 2022 | Braidwood | Design Basis Assurance Inspection (Teams) Inspection Report 05000456/2022010 and 05000457/2022010 |
IR 05000456/2020002 | 28 July 2020 | Braidwood | Integrated Inspection Report 05000456/2020002 and 05000457/2020002 |
IR 05000456/2019004 | 24 January 2020 | Braidwood | Integrated Inspection Report 05000456/2019004 and 05000457/2019004 |
ML18340A172 | 6 December 2018 | Oconee | NRC Inspection Report 05000269/2018090, 05000270/2018090, and 05000287/2018090 |
IR 05000272/2017003 | 27 June 2018 | Salem | Integrated Inspection Report 05000272/2017003 and 05000311/2017003 |
IR 05000327/2015007 | 1 June 2018 | Sequoyah | NRC Evaluation of Changes, Tests, and Experiments and Permanent Plant Modifications Inspection Report 05000327/2015007 and 05000328/2015007; Withdrawal of Non-Cited Violation |
IR 05000269/2018013 | 27 April 2018 | Oconee | NRC Inspection Report 05000269/2018013, 05000270/2018013, and 05000287/2018013 - Public |
IR 05000395/2018010 | 2 April 2018 | Summer | NRC Design Bases Assurance Inspection (Programs) Report Number 05000395/2018010 |
IR 05000255/2017002 | 8 August 2017 | Palisades | NRC Integrated Inspection Report and Exercise of Enforcement Discretion 05000255/2017002 |
IR 05000391/2016609 | 21 November 2016 | Watts Bar | Construction - NRC Integrated Inspection Report 05000391/2016609 |
IR 05000390/2016609 | 21 November 2016 | Watts Bar | Watts Bar Nuclear Plant Unit 2 Construction - NRC Integrated Inspection Report 05000391/2016609 |
IR 05000387/2015503 | 16 April 2015 | Susquehanna | IR 05000387/2015503, 05000388/2015503; 1/12/2015 to 3/17/2015; Susquehanna Steam Electric Station, Units 1 and 2; Problem Identification and Resolution |
IR 05000387/2014004 | 14 November 2014 | Susquehanna | IR 05000387-14-004, 05000388-14-004; 07/01/2014 - 09/30/2014; Susquehanna Steam Electric Station (Sses), Units 1 and 2; Followup of Events and Notices of Enforcement Discretion |
IR 05000454/2013005 | 3 February 2014 | Byron | IR 05000454-13-005 and 05000455-13-005; 10/01/13 - 12/31/13; Byron Station, Units 1 & 2; Heat Sink; Plant Modifications |
IR 05000341/2013008 | 29 October 2013 | Fermi | IR 05000341-13-008; 07/08/2013 - 09/06/2013; Fermi Power Plant, Unit 2; Component Design Bases Inspection (CDBI) |
IR 05000456/2013007 | 9 October 2013 | Braidwood | IR 05000456-13-007; 05000457-13-007(DRS); 7/29/2013 & 9/16/2013; Braidwood Station, Units 1 and 2; Component Design Bases Inspection (CDBI) |
IR 05000266/2013002 | 13 May 2013 | Point Beach | IR 05000266-13-002, 05000301-13-002, on 01/01/2013 - 03/31/2013, Point Beach, Units 1 & 2, Fire Protection, Heat Sink Performance, Occupational Dose Assessment, Identification & Resolution of Problems, Follow-Up of Events & Notices of Enfor |
ML13128A056 | 7 May 2013 | Dresden | IR 05000237-13-002, 05000249-13-002; 01/01/2013 - 03/31/2013; Dresden Nuclear Power Station, Units 2 & 3; Adverse Weather Protection and Identification and Resolution of Problem |
IR 05000348/2012005 | 31 January 2013 | Farley | IR 05000348-12-005 and 05000364-12-005; 9/01/12, - 12/31/12; Joseph M. Farley Nuclear Plant; Integrated Report |
IR 05000346/2012004 | 24 October 2012 | Davis Besse | IR 05000346-12-004, 7/1/2012 - 9/30/2012, Davis-Besse Nuclear Power Station, Maintenance Risk Assessments and Emergent Work Control, and Other Activities |
IR 05000454/2012002 | 10 May 2012 | Byron | IR 05000454-12-002, 05000455-12-002; 01/01/2012 - 03/31/2012; Byron Station, Units 1 & 2; Fire Protection and Plant Modifications |
IR 05000456/2012002 | 8 May 2012 | Braidwood | IR0 5000456-12-002, 05000457-12-002; Exelon Generation Company, LLC; 01/01/2012 ?03/31/2012; Braidwood Station, Units 1 & 2, Fire Protection, Flood Protection Measures Maintenance Effectiveness, Operability Determinations and Functional Ass |
IR 05000456/2011007 | 5 March 2012 | Braidwood | Annual Assessment Letter for Braidwood Station, Units 1 & 2 (Report 05000456-11-007 and 05000457-11-007) |
IR 05000454/2011007 | 5 March 2012 | Byron | Annual Assessment Letter for Byron Station, Units 1 and 2 (Report 05000454/2011007 and 05000455/2011007) |
IR 05000348/2011010 | 19 December 2011 | Farley | IR 05000348-11-010, 05000364-11-010; on 08/29/2011 - 12/08/2011; Joseph M. Farley Nuclear Plant, Units 1 and 2; Component Design Bases Inspection |
IR 05000237/2011008 | 27 October 2011 | Dresden | IR 05000237-11-008 (Drs), 05000249-11-008 (Drs), on 07/27/2011 - 10/17/2011, Dresden Nuclear Power Station, Routine Triennial Fire Protection Baseline Inspection |
IR 05000454/2011006 | 1 September 2011 | Byron | Mid-Cycle Letter for Byron Station, Units 1 & 2, 05000454/2011-006; 05000455/2011-006 |
IR 05000456/2011006 | 1 September 2011 | Braidwood | Mid-Cycle Letter for Braidwood Station, Units 1 and 2, - 05000456/2011-006; 05000457/2011-006 |
IR 05000456/2011010 | 29 June 2011 | Braidwood | IR 05000456-11-010, 05000457-11-010, on 2/1/11-6/10/11, Exercise of Enforcement Discretion |
IR 05000454/2011013 | 29 June 2011 | Byron | IR 05000454-11-013; 05000455-11-013, on 01/19/11-06/10/11, Byron Station, Units 1 and 2; Exercise of Enforcement Discretion |
IR 05000321/2011009 | 25 May 2011 | Hatch | IR 05000321-11-009 & 05000366-11-009, on 01/01/2011 - 04/02/2011, Edwin I. Hatch Nuclear Plant, Units 1 and 2, Component Design Bases Inspection Follow Up |
IR 05000341/2011002 | 2 May 2011 | Fermi | IR 05000341-11-002, on 01/01/2011 - 03/31/2011, Fermi Power Plant, Unit 2, Routine Integrated, Maintenance Effectiveness, Outage Activities, Identification and Resolution of Findings |
IR 05000255/2010005 | 8 February 2011 | Palisades | IR 05000255-10-005, on 10/01/2010 - 12/31/2010, Palisades Nuclear Plant, Inservice Inspection Activities, Maintenance Risk Assessments and Emergent Work Control, Surveillance Testing, Identification and Resolution of Problems, Other Activit |
IR 05000341/2010005 | 3 February 2011 | Fermi | IR 05000341-10-005, 10/01/2010 - 12/31/2010; Fermi Power Plant, Unit 2; Routine Integrated Ir. Operability Evaluations and Follow-Up of Events and Notices of Enforcement Discretion |
IR 05000456/2011009 | 1 February 2011 | Braidwood | IR 05000456-11-009 & 05000457-11-009; on January 13 - 19, 2011, Exelon Generation Company LLC; Braidwood Station, Units 1 and 2 Verification Inspection Related to Analysis Steam Generator Tube Rupture Event Margin to Overfill |
IR 05000454/2011010 | 19 January 2011 | Byron | IR 05000454-11-010 and 05000455-11-010; Exelon Generation Company, LLC; January 13, 2011; Byron Station, Units 1 and 2, Routine follow-up Inspection of Unresolved Item |
IR 05000341/2010006 | 30 April 2010 | Fermi | IR 05000341-10-006-ERRATA, on 01/25/2010 - 04/05/2010, Fermi Power Plant, Unit 2, Component Design Bases Inspection (CDBI) |
ML101180295 | 27 April 2010 | Fermi | IR 05000341-10-006; on 01/25 - 04/05/2010; Fermi Power Plant, Unit 2; Component Design Bases Inspection (CDBI) |
IR 05000445/2009005 | 9 February 2010 | Comanche Peak | IR 05000445-09-005, 05000446-09-005; on 09/20/2009 - 12/31/2009; Comanche Peak Steam Electric Station, Units 1 and 2; Operability Evaluations, Refueling and Other Outage Activities, Access Control to Radiologically Significant Areas, Other |
IR 05000285/2009005 | 5 February 2010 | Fort Calhoun | IR 05000285-09-005, 10/31/2009 - 12/31/2009; Fort Calhoun Station, Integrated Resident and Regional Report; Access Control to Radiologically Significant Areas |
IR 05000275/2009005 | 3 February 2010 | Diablo Canyon | IR 05000275-09-005, 05000323-09-005; 9/26/2009 - 12/31/2009; Diablo Canyon Power Plant, Integrated Resident and Regional Report; Refueling and Other Outage Activities; Identification and Resolution of Problems; ALARA Planning and Controls; |
IR 05000259/2009009 | 20 January 2010 | Browns Ferry | IR 05000259-09-009, 05000260-09-009, 05000296-09-009; 09/21/2009 - 09/25/2009; Browns Ferry Nuclear Plant, Units 1, 2, & 3; Triennial Fire Protection Inspection |
IR 05000454/2009004 | 5 November 2009 | Byron | IR 05000454-09-004, 05000454-09-004, on 07/01/09 - 09/30/09, Byron Station, Units 1 & 2; Identification and Resolution of Problems, and Preoperational Testing of an Independent Spent Fuel Storage Facility Installation (ISFSI) at Operating P |
IR 05000454/2009003 | 7 August 2009 | Byron | IR 05000454-09-003, 05000455-09-003; on April 01, 2009 - June 30, 2009; Byron Station, Units 1 & 2; Operability Evaluations |
ML092190925 | 7 August 2009 | Byron | IR 05000454-09-003, 05000455-09-003; on April 01, 2009 - June 30, 2009; Byron Station, Units 1 & 2; Operability Evaluations |
IR 05000259/2009007 | 14 July 2009 | Browns Ferry | IR 05000259-09-007, 05000260-09-007 and 05000296-09-007; 04/20 - 24/2009; Browns Ferry Nuclear Plant, Units 1, 2 and 3; Focused Fire Protection Baseline Inspection |
IR 05000390/2008005 | 24 March 2009 | Watts Bar | Denial of Non-Cited Violation 05000390-08-005-04, Carbon Dioxide System in Fire Area 48 Failed to Meet Design Criterion |
IR 05000341/2008005 | 30 January 2009 | Fermi | IR 05000341-08-005; on 10/01/2008 - 12/31/2008; Fermi Power Plant, Unit 2; Annual Heat Sink Performance; Surveillance Testing; and Other Activities |
ML082270712 | 14 August 2008 | Byron | IR 05000454-08-003; 05000454-08-003, on April 01 2008 - June 30, 2008, Byron Station, Units 1 and 2; Fire Protection, Inservice Inspection Activities, Maintenance Effectiveness and Maintenance Risk Assessments and Emergent Work Control |