 Entered dateEvent description
ENS 5598912 July 2022 13:22:00The following information was provided by the licensee via fax or email: At 1051 EDT on July 12, 2022, Seabrook Station received report of inadvertent siren activation. Local authorities have been contacted to apprise them of inadvertent activation of sirens. No press release is planned at this time. This event is being reported pursuant to 10 CFR 50.72(b)(2)(xi). The NRC Resident Inspector has been notified. The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance: The inadvertent activation involved one group of nine (9) sirens in the Seabrook Beach area. The cause of the activation is under investigation.
ENS 5538428 July 2021 16:30:00A licensed employee had a confirmed positive for alcohol during a random fitness-for-duty test. The employee's access to the plant has been suspended. The NRC Resident Inspector has been notified.
ENS 473276 October 2011 15:17:00At 1226 (EDT) today, Seabrook experienced an automatic reactor trip on low steam generator water levels. The low steam generator levels resulted following a trip of one of the two operating main feed pumps. Main feed pump 'A' tripped on low suction pressure while a condensate pump was being returned to service following maintenance on the pump. The emergency feedwater system actuated automatically and recovered steam generator levels. All systems actuated and functioned as designed. The wide range level indication on steam generator 'C' indicated erratically and was declared Inoperable. The plant is stable and being maintained in Mode 3. The station plans to cool the plant to Mode 5 for a previously planned forced outage. This notification provides a four-hour report for an actuation of the reactor protection system while the reactor is critical and an eight-hour report for a valid actuation of the emergency feedwater system. All rods fully inserted. Emergency feedwater has been secured and placed in standby and startup feedwater is supplying the steam generators. Decay heat is being removed to the condenser via the turbine bypass valves. Electrical systems are in a normal shutdown alignment. There is nothing unusual or not understood and all systems functioned as required. The licensee has notified the NRC Resident Inspector.