Semantic search
Jump to navigation
Jump to search
Quarter | Site | Title | Topic | |
---|---|---|---|---|
05000454/FIN-2017007-02 | 2017Q3 | Byron | Failure to Promptly Identify Degraded Reactor Containment Fan Cooler Circuitry | Condition Adverse to Quality Significance Determination Process |
05000341/FIN-2016001-04 | 2016Q1 | Fermi | Failure to Incorporate Operating Experience into Preventive Maintenance Activities Associated with the TBCCW System | Significance Determination Process |
05000331/FIN-2013004-02 | 2013Q3 | Duane Arnold | Failure to Perform CHANNEL CHECKs | |
05000263/FIN-2012002-01 | 2012Q1 | Monticello | FAILURE TO MONITOR CONDENSATE FEEDWATER SYSTEM UNDER 50.65(a)(1) DUE TO INADEQUATE MAINTENANCE RULE FAILURE TRACKING | Maintenance Rule Program |
05000266/FIN-2012002-04 | 2012Q1 | Point Beach | Scaffold Construction Interferes with the Operation of Containment Spray Suction Valve | Scaffolding |
05000331/FIN-2010003-02 | 2010Q2 | Duane Arnold | Failure to Adequately Define Requirements and Prescribe a Procedure Appropriate for Plant Conditions | |
05000331/FIN-2009006-01 | 2009Q3 | Duane Arnold | Failure to Identify and Address an Adverse Trend in Performing Required Fire Watches | Safe Shutdown Unanalyzed Condition Fire Protection Program |
05000305/FIN-2009003-04 | 2009Q2 | Kewaunee | Seismic Monitoring System Repeatedly Fails Surveillance | |
05000305/FIN-2009003-02 | 2009Q2 | Kewaunee | Emergency Diesl Generator Air System May Not Be Appropriately Qualified | Probabilistic Risk Assessment |