05000440/FIN-2018010-01 | 2018Q3 | Perry | Failure to Correctly Establish Maintenance/Replacement Frequencyfor the WeedTemperature Transmitters In Zone FB-7 |
05000331/FIN-2018011-01 | 2018Q2 | Duane Arnold | Failure to Translate Environmental Qualification Requirements into Maintenance Procedures/Instructions |
05000275/FIN-2018010-01 | 2018Q2 | Diablo Canyon | Failure to install conduit to environmentally qualified solenoid valves in a manner to prevent moisture intrusion and accumulation within the solenoid enclosure |
05000324/FIN-2018011-03 | 2018Q2 | Brunswick | Potential Unjustified Activation Energy for Rosemont Transmitters |
05000324/FIN-2018011-02 | 2018Q2 | Brunswick | Failure to Evaluate Effects of MOV Space Heaters on Qualified Life |
05000324/FIN-2018011-01 | 2018Q2 | Brunswick | Failure to Justify Qualified Life Extension of ASCO Solenoid Operated Valves |
05000395/FIN-2018010-02 | 2018Q1 | Summer | Failure to Verify the Seismic Qualification of Valcor Solenoid Operated Valve XVX06050A |
05000395/FIN-2018010-01 | 2018Q1 | Summer | Failure to Justify Activation Energy for Valcor SOV XVX06050A |
05000395/FIN-2018010-03 | 2018Q1 | Summer | Inadequate Radiation Harsh Environmental Qualification of Reactor Building Spray Pump A |
05000395/FIN-2018010-04 | 2018Q1 | Summer | Unjustified Qualified Life for ASCO Valves |
05000395/FIN-2018010-05 | 2018Q1 | Summer | Potential High Radiation Dose Areas with Unqualified Components |
05000395/FIN-2018010-06 | 2018Q1 | Summer | Potential Unjustified Activation Energy for Barton Transmitters |
05000327/FIN-2017008-01 | 2017Q4 | Sequoyah | Unjustified Qualified Life for Target Rock Power-Operated Relief Valves |
05000352/FIN-2017007-01 | 2017Q4 | Limerick | Failure to Document Technical Basis for Service Temperature Changes for Limitorque Motor Operated Valve Limit Switches |
05000261/FIN-2017007-01 | 2017Q4 | Robinson | Failure to Correctly Determine Qualified Life |
05000261/FIN-2017007-02 | 2017Q4 | Robinson | Failure to Perform Required O-ring Replacement to Maintain Qualification |
05000261/FIN-2017007-03 | 2017Q4 | Robinson | Failure to Determine Most Severe Containment Spray pH |
05000261/FIN-2017007-04 | 2017Q4 | Robinson | Crouse-Hinds Qualification and Life Extension |
05000261/FIN-2017007-05 | 2017Q4 | Robinson | Questions Regarding EQDP-0401 Method Used to Determine Activation Energy and Responsibility for Verification |
05000261/FIN-2017007-06 | 2017Q4 | Robinson | Penetration F01 Submergence |
05000261/FIN-2017007-07 | 2017Q4 | Robinson | Justification of Activation Energy of ASCO Solenoid Coil Assemblies |
05000327/FIN-2017008-02 | 2017Q4 | Sequoyah | Inadequate Qualification for Unit 1 Reactor Lower Compartment Cooler Motors |
05000327/FIN-2017008-03 | 2017Q4 | Sequoyah | Potential Inadequate Use of Thermal Aging and the Arrhenius Methodology |
05000327/FIN-2017008-04 | 2017Q4 | Sequoyah | Potential Inadequate Determination of Failure Modes for Qualified Life for Foxboro/Weed Instrument |
05000327/FIN-2017008-05 | 2017Q4 | Sequoyah | Potential Inadequate Justification for Eliminating Preventative Maintenance for ASCO Valves |
05000327/FIN-2017008-06 | 2017Q4 | Sequoyah | Potential Unjustified Qualified Life for ASCO Solenoid Operated Valves |
05000425/FIN-2017009-01 | 2017Q4 | Vogtle | Failure to Install Drain Hole |
05000336/FIN-2017007-01 | 2017Q3 | Millstone | Failure to Replace Auxiliary Feedwater Solenoid Valves within the Required Frequency |
05000313/FIN-2017007-01 | 2017Q3 | Arkansas Nuclear | Failure to Promptly Identify and Correct an Inadequate Design Bases Calculation |
05000482/FIN-2017007-01 | 2017Q2 | Wolf Creek | Failure to Maintain Effectiveness of the Emergency Plan upon Loss of Containment High Radiation Monitoring |
05000369/FIN-2017007-01 | 2017Q1 | Mcguire McGuire | Failure to Translate Required Gasket Replacement Requirements into Limit Switch Maintenance Manual |
05000237/FIN-2016009-01 | 2016Q3 | Dresden | Main Steam Acoustic Safety/Relief Valve Monitoring Channel Calibration Not Performed |
05000335/FIN-2016010-03 | 2016Q2 | Saint Lucie | Failure to Define, Justify, and Document Activation |
05000335/FIN-2016010-02 | 2016Q2 | Saint Lucie | Failure to Implement Qualification Procedures and Methods in Accordance with IEEE 323-1974 |
05000335/FIN-2016010-01 | 2016Q2 | Saint Lucie | Failure to comply with TS requirements for CHRRMs |
05000259/FIN-2016010-01 | 2016Q2 | Browns Ferry | Failure to Include Required Gasket Replacement in Limit Switch Surveillance Procedure |