Entergy; Entergy Nuclear Operations, Inc. 1340 Echelon Parkway Jackson, MS 39213 Tel 601-368-5573 Mandy K. Halter Director, Nuclear Licensing NL-18-045 July 3, 2018 U.S; Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station O-P1-17 Washington, DC 20555-0001

Subject:

Indian Point Nuclear Generating Unit 3 -Response to Request for Additional Information for Acceptance of License Amendment Request (LAA) for One-Time Extension of the Containment Type A Leak Rate Testing Frequency from 15 to 16 Years Docket No. 50-286 License No. DPR-64

REFERENCES:

1; NRC Email, "Request for Additional Information

-License Amendment Request for One-Time Extension of the Containment Type A Leak Rate Testing Frequency from 15 to 16 Years -Indian Point Unit No. 3 -Docket No. 50-286," dated May 23, 2018 2. Entergy Letter, "License Amendment Request (LAR) for One-Time Extension of the Containment Type A Leak Rate Testing Frequency from 15 to 16 Years -Indian Point Unit 3," dated December 8, 2017 (NL-17-137) (ML17349A131)

Dear Sir or Madam:

Entergy Nuclear Operations Inc. submitted a license amendment request [Reference 2] requesting one-time extension from 15 years to 16 years frequency for the Indian Po.int Unit No. 3 containment Integrated Leakage Rate Test. On May 23, 2018, the NRC [Reference 1] requested additional information needed for the NRG Staff to complete its review. The purpose of this letter is to provide the response to the RAls as requested in reference

1. Responses to the request for additional information are provided in Enclosure
1. There are no new regulatory commitments made in this submittal.

If you have any questions or require additional information, please contact Mr. Robert Walpole, Manager, Regulatory Assurance at (914) 254-6710.

NL-18-045 Docket No. 50-286 Page 2 of 2 I declare under penalty of perjury that the foregoing is true and correct. Executed on July 3, 2018. Sincerely, JJ2f~ Mandy K. Halter Director, Nuclear Licensing MKH/mm Enclosure 1: Response to Request for Additional Information needed for the NRC Staff to Complete its Review Regarding Indian Point Nuclear Generating Unit No 3 -"License Amendment Request (LAR) for One-Time Extension of the Containment Type A Leak Rate Testing Frequency from 15 to 16 Years" cc: Mr. David Lew, Acting Regional Administrator, NRC Region 1 Mr. Richard V. Guzman, Senior Project Manager, NRR/DORL, NRC Ms. Alicia Burton, President and CEO, NYSERDA (w/o Attachment)

Ms. Bridget Frymire, New York State Dept. of Public Service (w/o Attachment)

Mr. Bob Walpole, Regulato,ry Assurance Manager -Indian Point Energy center NRC Resident Inspector's Office ENCLOSURE 1 TO NL-18-045 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION NEEDED FOR THE NRC STAFF TO COMPLETE ITS REVIEW REGARDING INDIAN POINT NUCLEAR GENERATING UNIT NO 3 -"LICENSE AMENDMENT REQUEST (LAR) FOR ONE-TIME EXTENSION OF THE CONTAINMENT TYPE A LEAK RATE TESTING FREQUENCY FROM 15 TO 16 YEARS" Entergy Nuclear Operations, Inc. Indian Point Unit 3 Docket No. 50-286