Forwards Listed Documents in Support of Primary Plant Makeup Storage Tank Upgrade
ML20100Q608
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 03/07/1996
From: Marsh W
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20100Q610 List:
References
NUDOCS 9603120055
Download: ML20100Q608 (3)


Text

. - _ _-_ - -_ _

l l

,=.y ~D'Ei'

x

Southem Califomia Edison Company l P. O. BOX 128 SAN CLEMENTE, CAUFORNIA92674-0128 WALTER C. MARSH March 7, 1996 ,, _

..o,~uca....ovuroav y.... <7,c... I l

U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 l

Gentlemen:

1

Subject:

Docket Nos. 50-361 and 50-362 l Primary Plant Makeup Storage Tank Upgrade l San Onofre Nuclear Generating Station '

Units 2 and 3

Reference:

Lecember 30, 1992 letter from Harold B. Ray (Edison) to Document Control Desk (NRC), Subject; Proposed Technical Specification Change No. NPF-10/15-418 j This letter provides documentation of information requested by the NRC in l support of the San Onofre Units 2 and 3 Primary Plant Makeup Storage Tank l (PPMUT) Upgrade. This information supports the NRC review of the above reference. The following items are provided as enclosures to this letter:

-(1) Unit 2 PPMUT Upgrade Calculation M-DSC-280, dated October 7, 1993 (2) Unit 3 PPMUT Upgrade Calculation M-DSC-269, dated November 23, 1993 (3) Summary Report - Primary Plant Make Up Storage Tank Upgrade, dated October 1995 (4) Responses to Quastions from NRC Reviewers (5) Changes to bait 2 Amendment Number 127 and Unit 3 Amendment Number l 116 Technical Specification and Bases pages for Proposed Change

, Number 418 (Reference).

9603120055 960307

, PDR ADOCK 05000361 l P PDR , .

I i

Document Control Desk  ;

If you have any questions regarding this information, please contact me.

Sincerely, h \

l Enclosures i l

cc: L. J. Callan, Regional Administrator, NRC Region IV J. E. Dyer, Director, Division of Reactor Projects, Region IV K. E. Perkins, Jr., Director, Walnut Creek Field Office, NRC Region IV l J. A. Sloan, NRC Senior Resident Inspector, San Onofre Units 2 & 3 l M. B.. Fields. NRC Project Manager, San Onofre Units 2 and 3 l

1 l

1

A J

ENCLOSURE 1 UNIT 2 PPMUT UPGRADE CALCULATION M-DSC-280 1

4 J

4 4

4 V