Forwards Application for Amend to License DPR-59,revising Tech Specs to Reflect Containment Isolation Valves in RHR & Core Spray keep-full Sys
ML20043G249
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 06/12/1990
From: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20043G250 List:
References
JPN-90-048, JPN-90-48, NUDOCS 9006200093
Download: ML20043G249 (2)


Text

i Ia en Wrk 1NO1

.. 914 fJrl fd40

c. .

M ( John C. Brons M MU M $$$NN" June 12,1990 JPN 90048 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk l Mail Station P1137 Washington, D.C. 20555

SUBJECT:

Jamoa A. FitzPatrick Nuclear Power Plant Docket No. 50-333 Proposed Changes to the Technical Specifications Regarding Containment isolation Valves in the Residual Heat Removal (RHR) and Core Spray Keep-Full Systems (JPTS 9N)01)

Dear Sir:

1 This application for an amendment to the James A. FitzPatrick Technical Specifications updates Tables 3.71 (* Primary Containment Isolation Valves

  • on page 206c) and 4.7 2 (' Exception to Type C Tests" on page 213) to reflect the Containment isolation Valves (CIVs) in the RHR and Core Spray keep full systems. Four containment isolation valves are added to the table of primary containment isolation valves, Table 3.71. In addition, these same four valves are also added to table of Exceptions To Type C Tests, Table 4.7 2. Both keep-full systems are designed to maintain system piping filled with water thereby reducing the potential for water hammer and increasing the overall system reliability.

The minimum flow discharge lines associated with these keep-full systems are discharged into the suppression pool below the water line. Check valves are used to isolate these lines since they are in accordance with the FitzPatrick original design basis, where it is acceptable to use check valves to isolate lines that are submerged below the torus water level, it is not necessary to conduct a Type C leak test on these lines since the piping inside containment is sealed with fluid from a seal system (torus water).

The RHR keep full system will be installed during the 1990 refueling outage and will not be declared operational until this proposed Technical Specification change has been issued by the NRC staff Until then, the RHR keep full minimum flow discharge I lines will remain isolated and active equipment will be de energized P

h620o93900612 DOCK 0500o333 f

P q\

- _ - _ _ _ _ _ __a

Enclosed for filing is the signed original of a document entitled

  • Application for Amendment to Operating Uoonse,' with Attachments I and 11 thereto, comprising a statement of the proposed changes to the Technical Specifications and the associated Safety Evaluation, in nooordance with 10 CFR 50.91, a copy of this application and the associated attachments are being provided to the designated New York State official.

Should you or your staff have any questions regarding the proposed changes, please contact Mr. J. B. Ellmers of my staff.

Very truly yours, t

$hn.Brons Executive Vice President uclear Generation ec
Regional Administrator U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Office of the Resident inspector U.S. Nuclear Regulatory Commission P.O. Box 136 Lycoming, NY 13083 Mr. David E. LaBarge Project Directorate 11 Division of Reactor Projects l/II U.S. Nuclear Regulatory Commission Mail Stop 14 B2 Washington, D.C. 20555 Ms. Donna Ross New York State Energy Office 2 Empire State Plaza 16th Fl w Albany, NY 12223 l