l evnw runni aoo U. S. NUOLEAR REGULATORY COMMISSION

. LICENSEE EVENT REPORT OU RE ORT DATE: 7/16/82 CONTROL SLOCK: { ,l 1

l l l l 6

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI t o t 8i 9l l 1 ILICENSEE 7 t I D lCODE R I S 13 l@l O! 01 -IuCENSE 14 15 01 01 NUMBER 0l 01 0l -l 0l250 l@l 26 4uGENsE l l l 1lTYPE 1l.ll@l JO l

57 OAT 58 lg CON'T loiii i 4

$$$ l 60L @l 0 l 5 10 l 0 10 l 2 l 4 l 9 gl 0; 7 l l j 618l 2 @l 1l 2 l 0l 8) 8 l 2 l@

61 3OCKET NUWS ER 68 09 - EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PRC8ABLE CONSEQUENCES h lo62l lDurine normal operations while exercising the TIP ball valves, 3A TIP ball valve l

o93; l failed to reclose after opening (Tech. Spec. 3.7.D.1). This was of minimal safety l I o r A I l significance since the TIP shear valve was available to isolate the TIP if necessary. l lo isi I There was no effect on public health or safety. Last occurrence of this type reported; I o is 1 J by R.O. 77-17 on Docket 50-237. l l

, l o 6 71 l l 1

10!81l I 7 a9 80 SYSTEM CAusE CAUsE COMP. VALV E CCCE CODE susCCDE COMPONENT CODE sVSCCDE suSCODE

{ 1019 l' 7 8

[ S l toD l@ {@ l Al@ l Vl Al Ll Vl El Xl@ l A l@ g @

9 11 12 13 18 19 20

,_ SEQUENTIAL OCCURRENCE REPORT REVislON

! LE RIRo EVENT YEAR REPORT NO. CODE l @Rg l218 2212 l l_l 23 l 0l 3l 0[

24 28 l ,,,. l 27 l0l3l 28 29 TYPE lX l 30 g

No.

llj

_ 31 22 EON" "a"CEEE oEPtNT **SE w NouRs 22 *5sTiTT!o' s PoES s. "s'Us'et?. EE u$u"P2ETu"RER -

l33 A gl4Z lg 3

l5Z l g l6 Zlg l 0l 0l 0l l

@@ l Y l@ l N l@ l X l 9 l 9 l 947 l@

3 3 37 40 41 42 43 44 CAuSE DESCRIPTION AND CORRECTIVE ACTIONS @

lilolISpecific cause was unknown. Limit switches and ball valve were replaced and success- I Iiiil lfullv tested for operability. DOS 1600-8 will continue to be performed weekiv. The I g l.25 inch solenoid activated valve is supplied by General Pneumatic Corporation. l li t al l I

, it 14 1 I l l 7 s e so

's#

i lE sPowER oTwEpsTATus h "'sEcOSOY oisCovERY otsCRimoN @

l 7l1 15l d h l0l9l9[gl N/A l l B lgl Routine Test l eg ty t2 n 44 as as s0

, KELEAsED oPRELEASE AMOUNT OF ACTIVITY LOCAT10N QP RELEASE l l1 } s' *l l Zl @' Wgl N/A l l N/A l PEmsoNNEL Exposures NvusER -ves l1 l* 7* l l 0 l' 0 l0 l@l Zl@letsCRimeN @N/A l

  • tRsoNNa'L iN;u'dits '

NuusER l ' l aeIal 0 l 0 l 0nl@l12=EsCRimeN@N/A l 7

8301070193 821208 80

'450'0"3E^^_",,y40 'aciuTv @ /ADR ADOCK 05000249 E

l1lgl N PDR 7 8 9

@[10 l 80 E CRIPTION NRC USE ONLY ,

i2i,i issyET8Lis N/A l l l ll l ll tii i! lj P e 3 to 68 69 80 5 Wayne Morgan 815-942-2920, X-489 o NAME OF PREPARER PHON E: $ I l '

li i'

. SUPPLEMENT TO DVR

STA UNIT. YEAR NO.

D- 12 - 3 - 82 - 49 PART I l TITLE OF EVENT OCCURRED Failure of 3A TIP Ball Valve DATE TIME

{ REASON FOR SUPPLEMENTAL REPORT l

To update the cause and corrective action for the failure of 3A TIP Ball Valve to close, PART 2 l ACCEPTANCE BY STATION REVIEW /

/4/

DATE \ L\ \bl 7 3

/'

/h SUPPLEMENTAL REPORT APPROVED

[f. /

AND AUTHORIZED FOR DISTRIBUTION ,' M W/t/(4f[- /L/6[8F

'STATiogi SyPERINTENDENT BATE t

f 9

{

, _ - . _ _ - _ --. . . , . -