ML18340A030

From kanterella
Jump to navigation Jump to search
Tennessee Valley Authority - Sequoyah, Study to Confirm Calibration of Numerical Model
ML18340A030
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 11/30/2018
From: Anthony Williams
Tennessee Valley Authority
To: Janjic V
Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation
References
TN0026450 WR2018-1-45-153
Download: ML18340A030 (31)


Text

Tennessee Valley Authority, Post Office Box 2000, Soddy Daisy, Tennessee 37384-2000 November 30, 2018 Mr. Vojin Janjic Division of Water Resources Ter,nessee Department of Environment and Conservation (TDEC)

William R. Snodgrass Tennessee Tower 312 Rosa L. Parks Avenue, 11th Floor Nashville, Tennessee 37243

Dear Mr. Janjic:

TENNESSEE VALLEY AUTHORITY (TVA) - SEQUOYAH NUCLEAR PLANT (SQN) - NPDES PERMIT NO. TN0026450 - STUDY TO CONFIRM CALIBRATION OF NUMERICAL MODEL Enclosed is a copy of the 2018 study to confirm the calibration of the numerical model for the thermal discharge from SQN. This study is required by Part Ill. H of the subject permit to be completed once during the permit cycle, which expires on December 31, 2018. The study concludes there was no significant change in the model performance compared to the previous calibration, and as a result, no update was required in the model parameter set. TVA requests this study report be included in your records with SQN's NPDES permit application for renewal submitted on June 29, 2018.

If you have any questions regarding this NPDES permit renewal application, please contact Millicent Garland at (423) 843-6714, or by email at mrmoore@tva.gov.

Enclosure cc: Ms. Jennifer Innes Program Manager Chattanooga Environmental Field Office Division of Water Resources 1301 Riverfront Parkway, Suite #206 Chattanooga, Tennessee 37402 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Mr. Vojin Janjic Page2 November 30, 2018 TRM cc (Enclosure - Electronic Distribution):

T. R. Markum, BR 4A-C D. E. McGee, OSA 1D-M M. M. Rasmussen, POB 2A-SQN D. P. Saint, WT 108-K A. L. Williams IV, OPS 4A-SQN ECM, ENVrecords

TENNESSEE VALLEY AUTHORITY Resources & Operations Support Study to Confirm the Calibration of the Numerical Model for the Thermal Discharge from Sequoyah Nuclear Plant as Required by NPDES Permit No. TN0026450 of June 2015 WR2018-1-45-153

, Prepared by Jessica C. Brazille T. Matthew Boyington Walter L. Harper Knoxville, Tennessee November 2018

EXECUTIVE

SUMMARY

The National Pollutant Discharge Elimination System (NPDES) permit for Sequoyah Nuclear Plant (SQN) identifies the release of cooling water to the Tennessee River through the plant discharge diffusers as Outfall 101. The primary method to monitor compliance with the NPDES temperature limits for this outfall includes the use of a numerical model that solves a set of governing equations for the hydrothermal conditions produced in the river by the interaction of the

  • SQN release and the river discharge. The numerical model operates in real-time and utilizes a combination of measured and computed values for the temperature, flow, and stage in the river; and the temperature and flow from the SQN discharge diffusers. Part III, Section G of the permit states: The numerical model used to determine compliance with the temperature requirements for Outfall IO I shall be subject of a calibration study once during the permit cycle. The study should be accomplished in time /or data to be available for the next permit application for re-issuance of the permit. A report ofthe study will be presented to the division of Water Pollution Control. This report is provided in fulfillment of these requirements.

The basic formulation of the numerical model is presented herein. Three empirical parameters are used to calibrate the model. The first is the effective width of the diffuser slot, and the second is a relationship used to compute the entrainment of ambient water along the trajectory of the plume.

The third parameter is a relationship for the amount of diffuser effluent that is re-entrained into the diffuser plume for periods of sustained low river flow.

Temperature measurements across the downstream end of the SQN mixing zone from fifty-one samples collected between 1982 and 2018 were used in this calibration study. This observed data was compared with computed downstream temperatures from the numerical model for the same periods of time. In this process, sensitivity tests were performed for the effective diffuser slot width, entrainment relationship, and plume re-entrainment function. The results show acceptable agreement between computed and measured temperatures, particularly at river temperatures greater than 75°F. The overall average discrepancy between the measured and computed downstream temperatures was about 0.55 F° (0.31 C0 ) . For downstream temperatures above 75°F, the average discrepancy was about 0.38 F° (0.21 C0 ). There was no significant change in the model performance compared to the previous calibration, and as a result, no update was required in the model parameter set.

CONTENTS Page EXECUTIVE

SUMMARY

............................................................................................................. i LIST OF FIGURES ....................................................................................................................... iii LIST OF TABLES ............................*............................................................................................. iii INTRODUCTION ...........................*............................................................................................... 1 BACKGROlJND ........................... :.; .............................................................................................. 3 NUMERICAL MODEL .................. '. .................. ,...................................................... ;..................... 7 Plume Entrainment ........................................................................................................... 12 Diffuser Effluent Re-Entrainment..................................................................................... 13 CALIBRATION .................................................................................................................. ~ ........ 13 Previous Calibration Data and Calibration Work ................................................................... 13 New Calibration Data and Calibration Work ..................................................*........................ 16 Diffuser Slot Width ..................................................................................*.......................... 16 Plume Entrainment Coefficient ......................................................................................... 16 Diffuser Effluent Re-Entrainment..................................................................................... 18 Results of Updated Calibration ........................................................................................ 20 CONCLUSIONS ........................................................................................................................... 23 REFERENCES ............................................................................................................................. 24 11

LIST OF FIGURES Figure 1. Location of Sequoyah Nuclear Plant .............................................................................. 1 Figure 2. Chickamauga Reservoir in the Vicinity of Sequoyah Nuclear Plant ............................. 2 Figure 3. Locations oflnstream Temperature Monitors for Sequoyah Nuclear Plant.. ................. 6 Figure 4. Sequoyah Nuclear Plant Outfall 101 Discharge Diffusers ............................................. 7 Figure 5. Two-Dimensional Plane Buoyant Jet Model for a Submerged Diffuser ........................ 8 Figure 6. Sensitivity of Computed Temperature T d to Diffuser Effective Slot Width ................ 17 Figure 7. Sensitivity of Computed Temperature Td to Plume Entrainment Coefficient .............. 18 Figure 8. Sensitivity of Computed Temperature Td to Effluent Re-Entrainment Function ......... 19 Figure 9. Comparison of Computed and Measured Temperatures Td for Field Studies from April 1982 through November 2012 .................................................................. .21 Figure 10. Comparison of Computed and Measured 24-hour Average Temperatures Td for Station 8 for 2010 ....................................................................................................... 21 Figure 11. Comparison of Computed and Measured Hourly Average Temperatures Td for Station 8 for 2010 ...................................................................................................... 22 LIST OF TABLES Table 1. Summary of SQN Instream Thermal Limits for Outfall 101 ........................................... 5 Table 2. Thermal Surveys at SQN from April 1982 through March 1983 .................................. 14 Table 3. Thermal Surveys at SQN from March 1996 through April 2003 .................................. 15 Table 4. Thermal Surveys at SQN from February 2004 through November 2007 ...................... 15 Table 5. Thermal Surveys at SQN from November 2012 ........................................................... 16 Table 6. Plume Re-Entrainment Iteration Numbers and Factors ................................................. 19 iii

INTRODUCTION The Sequoyah Nuclear Plant (SQN) is located on the right bank of Chickamauga Reservoir at Tennessee River Mile (TRM) 484.5. As shown in Figure 1, the plant is northeast of Chattanooga, Tennessee, about 13.5 miles upstream and 45.4 miles downstream of Chickamauga Dam and Watts Bar Dam, respectively. As shown in Figur~2, the reservoir in the vicinity of SQN contains a deep main channel with adjacent overbanks and embayments. The main channel is approximately 900 feet wide and 50 to 60 feet deep, depending on the pool elevation in Chickamauga Reservoir. The overbanks are highly irregular and usually less than 20 feet deep.

SQN has two units with a total summertime gross generating capacity of about 2350 MWe and an associated waste heat load of about l5.6x10 9 Btu/hr (TVA, 2010). The heat transferred from the steam condensers to the cooling water is dissipated to the atmosphere by two natural draft cooling towers, to the river by a two-leg submerged multi port diffuser, or by a combination of both. The release to the river is identified in the National Pollutant Discharge Elimination System (NPDES)

Permit as Outfall 10 I .

  • j WATTS BAR NUCLEAR PLANT CLEVELAND

{t I CHICKAMAUGA DAM I .

TRM 471.0 NORTH

//'~/A CHATTANOOGA


1----------

CAROLINA

'\

Figure 1. Location of Sequoyah Nuclear Plant I

rm111110i Denotes Reservoir areas of water depth less than 20 feet Mixing Zon

  • Figure 2. Chickamauga Reservoir in the Vicinity of Sequoyah Nuclear Plant 2

The compliance of SQN operation with the instream temperature limits specified in the NPDES permit (TDEC, 2015) is based on a downstream temperature that is calculated on a real-time basis by a numerical computer model. Part III, Section G of the permit states:

The numerical model used to determine compliance with the temperature requirements for Outfall,101 shall be subject of a calibration study once during the permit cycle. The study should be accomplished in time for data to be available for the next permit application for re-issuance of the permit. A report of the study will be presented to the Division of Water Pollution Control. Any adjustments to the numerical model to improve its accuracy will not need separate approval from the Division of Water Pollution Control; however, the Division will be notified when suph adjustments are made.

This report presents a summary of compliance model and the required calibration study.

BACKGROUND The original method of monitoring thermal compliance for the SQN diffuser discharge (i.e.,

Outfall 101 ), included two temperature stations located near the downstream comers of the mixing zone, Station 8 and Station 11 (see Figure 2). Because of the necessity to keep the navigation channel free of obstructions, temperature stations could not be situated between these locations to monitor the center of the thermal plume. The upstream ambient river temperature was measured at Station 13, located on the plant intake skimmer wall. In August 1983, the Tennessee Valley Authority (TVA) reported the results of six field studies of the SQN diffuser performance under various river and plant operating conditions (TVA, 1983a). The data summarized in the report showed that based on measured temperature variations across the downstream edge of the mixing zone, Station 8 and Station 11 were inadequate in providing a representative cros~-sectional average temperature of the thermal plume. In particular, it was found that Station 11 often was not in the main path of flow ofthe thermal plume and did not always show elevated temperatures.

The remaining downstream monitor, Station 8, also was not considered adequate because it again was located outside the navigation channel. In the report, TVA proposed an alternate method to monitor thermal compliance involving the use of a numerical model to simulate the behavior of the thermal plume in the mixing zone. The model would provide a real-time assessment of compliance with the thermal discharge limitations. Information required for the model included:

the ambient river temperature upstream of the diffuser mixing zone (measured at Station 13, see Figure 2), the discharge in the river at SQN (determined from measurements at Watts Bar Dam and Chickamauga Dam), the depth of flow in the river (measured at Station 13), the temperature of the flow issuing from the plant diffusers (measured at Station 12, see Figure 2), and the discharge of the flow issuing from the diffusers (determined from measurements at both Station 12 and Station 13). A PC, located in the SQN Environmental Data Station (EDS), was to be used collect the required data, compute the thermal *compliance parameters, and distribute the results to plant operators (see TVA, 1983b). The August 1983 report presented results demonstrating the validity of using the numerical model .for tracking compliance with the Outfall 101 thermal limitations.

3

The method of using the numerical model was sent to the Environme ntal Protection Agency (EPA) and the Tennessee Departmen t of Environme nt and Conservatio n (TDEC), requesting approval for implementation as a valid means for monitoring SQN thermal compliance . The key advantage of the method includes a representation of the cross"'sectional average downstream temperature that is at least as good as the instream temperature measureme nts from Station 8 and Station 11. The method also provides consistency with procedures that are used for scheduling releases from Watts Bar Dam and Chickamau ga Dam, as well as procedures for operating Sequoyah Nuclear Plant.

This consistency helps TVA minimize unexpected events that can potentially threaten the NPDES thermal limits for Outfall 10 l. In March 1984 approval was granted for TVA to use the numerical model as the primary method to track thermal compliance.

  • Except for infrequent outages, the model has been in use ever since. Subsequently, Statfon 11 was removed from the river. However, Station 8 was retained to provide an optional method to track thermal compliance should there be a need to remove the model from service.

Due to the ever changing understandi ng of the hydrotherm al aspects of Chickamau ga Reservoir, as well as the operational aspects of the nuclear plant and river system, modifications have been necessary over the years for both the numerical model and thermal criteria for Outfall 101. The current version of the model is presented in more detail later. The current thermal criteria are presented in Table 1. The limit for the temperature at the downstream end of the mixing zone (Tct) is a* 24-hour average value of 86.9°P (30.5°C) and an hourly average value of 93.0°P (33.9°C).

The instream temperature rise (~T) is limited to a 24-hour average of 5.4 F° (3.0 C0 ) for months April through October, and 9.0 P0 (5.0 C0 ) for months November through March. The latter "wintertime " limit was obtained by a 3 l 6(a) variance. The temperature rate-of-change at the downstream end of the mixing zone (dTct/dt) is limited to +/-3.6 P0 /hr (+/-2 C 0 /hr). With the compliance model, dTctldt is based on 24-hour average river conditions and 15 minute plant conditions. Other details related to the temperature limits for Outfall 101 are provided in the notes accompany ing Table 1. It is important to note that compliance with instream temperature limits are based on a computed downstream temperature at a depth of 5.0 feet. And in a similar fashion, the upstream temperature is measured at the 5.0 foot depth, based on the average of temperature readings at the 3-foot, 5-foot and 7-foor depths.

Originally, the ambient river temperature for the temperature rise was measured at Station 13, about 1.1 miles upstream of the discharge diffusers. However, under sustained low flow conditions, it was discovered that heat from the diffusers can migrate upstream and reach the area of Station 13. In this manner, the ambient temperature can become elevated, thereby artificially reducing the measured impact of the plant on the river (i.e., ~T). As such, in late March 2006, a new ambient temperature station was installed iri the river further upstream at TRM 490.4, about 6.8 miles upstream of the diffusers. The location of the new monitor, entitled Station 14, is shown in Figure 3.

4

Table 1. Summary of SQN Instream Thermal Limits for Outfall 101 Averaging NPDES Type of Limit (hours) Limit2 Max Downstream Temperature, Tct 24 86.9°F (30.5°C)

Max Downstream Temperature, Tct 1 93.0°F (33.9°C)

Max Temperature Rise, ~T 24 5.4 F /9.0 F 0 (3.0 C0 /5.0 C0 )

0 Max Temperature Rate-of-Change, dTctldt Mixed +/-3.6 F°/hr (+/-2 C 0 /hr)

Notes:

1. Compliance with the river limitations (river temperature, temperature rise, and rate of temperature change) shall be monitored by means of a numerical model that solves the thermohydrodynamic equations governing the flow and thermal conditions in the reservoir. This numerical model will utilize measured values of the upstream temperature profile and river stage; flow, temperature and performance characteristics of the diffuser discharge; and river flow as determined from releases at the Watts Bar and Chickamauga Dams. In the event that the modeling system described here is out of service, an alternate method will be employed to measure water temperatures at least one time per day and verify compliance of the maximum river temperature and maximum temperature rise. Depth average measurements can be taken at a downstream backup temperature monitor at the downstream end of the diffuser mixing zone (left bank Tennessee River mile 483.4) or by grab sampling from boats. Boat sampling will include average 5-foot depth measurements (average of 3, 5, and 7-foot depths). Sampling from a boat shall be made outside the skimmer wall (ambient temperature) and at quarter points and mid-channel at downstream Tennessee River mile 483.4 (downstream temperatunr). The downstream reported value will be a depth (3, 5, and 7-foot) and lateral (quarter points and midpoint) average of the instream measurements. Monitoring in the alternative mode using boat sampling shall not be required when unsafe boating conditions occur. .
2. Compliance with river temperature, temperature rise, and rate of temperature change limitations shall be applicable at the edge ofa mixing zone which shall not exceed the following dimensions: (1) a maximuinlength of 1500 feet downstream of the diffusers, (2) a maximum width of 750 feet, and (3) a maximum length of 275 feet upstream of the diffusers. The depth of the mixing zone measured from the surface varies linearly from the surface 275 feet upstream of the diffusers to the top of the diffuser pipes and extends to the bottom downstream of the diffusers. When the plant is operated in closed mode, the mixing zone shall also include the area of the intake forebay.
3. Information required by the numerical model and evaluations for the river temperature, temperature rise, and rate of temperature change shall be made every 15 minutes. The ambient temperature shall be determined at the 5-foot depth as the average of measurements at depths 3 feet, 5 feet, and 7 feet. The river temperature at the downstream end of the mixing zone shall be determined as that computed by the numerical model at a depth of5 feet.
4. Daily maximum temperatures for the ambient temperature, the river temperature at the downstream edge of the mixing zone, and temperature rise shall be determined from 24-hour average values. The 24-hour average values shall be calculated every 15 minutes using the current and previous ninety-six IS-minute values, thus creatiii.g*a 'rolling' average. The maximum of the ninety-six observations generated per day by this procedure shall be reported as the daily maximum value. For the river temperature at the downstream end of the mixing zone, the 1~hour average shall also be determined. The I-hour average values shall be calculated every 15 minutes using the average of the current and previous four 15-minute values, again creating a rolling average.
5. The daily maximum 24-hour average river temperature is limited to 86.9°F (30.5°C). Since the state's criteria makes exception for exceeding the value as a result of natural conditions, when the 24-hour average ambient temperature exceeds 84.9°F (29.4°C) and the plant is operated in helper mode, the maximum temperature may exceed 86.9°F (30.5°C). In no case shall the plant discharge cause the I-hour average downstream river temperature at the downstream of the mixing zone to exceed 93.0°F (33.9°C) without the consent of the permitting authority. *
6. The temperature rise is the difference between the 24-hour average ambient river temperature measured at Station 14 and the computed 24-hour average temperature at the downstream end of the mixing zone. The 24-hour average temperature rise shall be limited to 5.4F 0 (3.0 C 0 ) during the months of April through October. The 24-hour average temperature rise shall be limited to 9.0F0 (5.0 C0 ) during the months of November through March.
7. The rate of temperature change shall be computed at 15-minute intervals based on the current 24-hour average ambient river temperature, current 24-hour-hour average t;iver flow, and current values of the flow and temperature of water discharging through the diffuser pipes. The I-hour average rate of temperature change shall be calculated every 15-minutes by averaging the current and previous four IS-minute values. The I-hour average rate oftemperature change shall be limited to 3.6F0 (2 C 0 )

per hour.

5

Figure 3. Locations of Instream Temperature Monitors for Sequoyah Nuclear Plant 6

NUMERICAL MODEL The diffusers at SQN are located on the bottom of the navigation channel in Chickamauga Reservoir. As shown in Figure 4, each diffuser is 350 feet long, and contains seventeen 2-inch diameter ports per linear foot of pipe, arranged in rows over an arc of approximately 18 degrees in the downstream upper quadrant of the diffuser conduit. The two diffuser legs rest on an elevated pad approximately 10 feet above the bottom of the river, occupying the 700 feet of navigation channel on the plant-side of the river (right side of the channel, looking downstream). The flow in the immediate vicinity of the ports is far too complex to be analyzed on a real-time basis with current computer technology. Therefore, a simplifying assumption is made that the diffusers can be treated as a slot jet with a length equal to that of the perforated sections of the pipe. The width of this assumed slot is one of three empirical parameters used to calibrate the model. The second is a relationship used to compute the entrainment of ambient water along the trajectory of the plume and the third is a relationship for the amount of diffuser effluent that is re-entrained into the diffuser plume for sustained low river flow.

The initial development of the numerical model is described in detail by Benton (2003). Based on later studies that provided evidence that re-entrainment occurs (TVA, 2009), the original numerical model was modified to better reflect the local buildup of heat that occurs in the river under such conditions. Before presenting calibration results, it is appropriate first to provide a brief description of the model formulation.

II I ,I, .

II I II I II I I

t---3501~

I I 3liOIL .UI I II II I.

I I I

I I 60011.

I II I I I - [I 111 I I

[i, II I I

...IA..)

RIVER l 11 I I . ' 1, 0~ 0 0 (0

FLOW 111 I I

' 1--'i. DIFFUSER GATE EL680 NOIIYAL MAX,_ FOOL EL~::,

NORIIAL MINIIIIUII POOi. EL filh 16 fl OIAMETE R DOWNSTREAM DIFFUSER LEG EL650.!i RIVER

  • DISCHARGE PORTS 0 O 0 Fla,rt_. 0 O EL635 0 0: 0 0

0 0

0 0

RIPRAP 0 0 ARRANGEMENT OF PORTS PORT DIAMETER 2*

SECTION A-A ALTERNATING COWNNS OF 8 AND 9 PORTS Figure 4. Sequoyah Nuclear Plant Outfall 101 Discharge Diffusers In general, the model treats the effluent discharge from the diffusers as a fully mixed, plane buoyant jet with a two-dimensional (vertical and longitudinal) trajectory. This is shown 7

schematically in Figure 5. The jet discharges into a temperature-stratified, uniform-velocity flow and entrains ambient fluid as it evolves along its trajectory. The width, b, of the jet and the dilution of the effluent heat energy increase al orig the jet trajectory, decreasing the bulk mixed temperature along its path.

y s

/

l

/

/

/

/

Figure 5. Two-Dimensional Plane Buoyant Jet Model for a Submerged Diffuser Consideration of the mass, momentum, and energy for a cross section of the plume orthogonal to the jet trajectory and having a differential thickness ds, yields the following system of ordinary differential equations,

.!!_(pl v1b) = me (conservation of mass in jet), (1) ds

.!!_(p1v1bu )= meue (conservation of x momentum in jet), (2) ds

.!!_(p1viv )= me ve + bg(pe - pJ (conservation of y momentum in jet), (3) ds

.!!_(p1v1bcTJ= mecTe (conservation of thermal energy injet), (4) ds dx u

- = - , and (5) ds VJ dy = -2'.... (velocity of jet tangent to-trajectory). (6) ds v1 The following auxiliary relationships also are needed to solve the differential equations, 8

me= apJ(ue -u)2 +v2 r2' (7)

. Pj = Pwa,er (TJ, (8)

Pe = Pwater (Te), (9)

Te = Triver (y)' (10) ue = uriver' (11)

Ve= 0, and (12) vj = (u 2+v 2)1/2 . (13)

In these equations, the subscripts j and e denote conditions within the buoyant jet and conditions within the water upstream of the mixing zone that is entrained by the jet, respectively. Thus, /Jj denotes the density of water at a point inside the jet and pe denotes the density of water entrained from 11pstream of the mixing zone. Te denotes the temperature of the water upstream of the mixing zone that is entrained by the jet. The x-velocity of the entrained water, ue, is the same as the river velocity, Uriver, which is negligible in the vertical direction (i.e.; Ve = 0). The magnitude of the velocity along the jet trajectory is denoted by Vj, with x- and y-components u arn;I v, respectively.

The individual jets issuing from the array of 2-inch diameter outlet ports of each diffuser are modeled as a plane jet issuing from a slot of width bo. Ideally, the slot width is chosen to preserve the total momentum flux issuing from the circular ports of the diffuser. However, as indicated earlier, for this formulation, the slot width is used as a term to calibrate the numerical model. The river velocity Uriver is computed by a one-dimensional unsteady flow model of Chickamauga Reservoir. Apart from information for the reservoir geometry, the basic input for the flow model includes the measured hydro releases at Watts Bar Dam and Chickamauga Hydro Dam and the measured river water surface elevation at SQN.

The transverse gradients of velocity, temperature, and density that occur within the jet due to turbulent diffusion of the effluent momentum and energy are modeled as an entrainment mass flux, me, induced by the vectorial difference between the velocity of the jet and that of the river flow upstream of the mixing zone. Empirical relationships for the entrainment coefficient a are based on arguments of jet self-similarity and asymptotic behavior. These relationships incorporate non-dimensional parameters, such as a Richardson or densimetric Froude number, that describe the relative strengths of buoyancy and momentum flux in the jet (e.g., see Fischer et al., 1979). Again, as indicated earlier, the entrainment coefficient, like the slot width, is adjusted as part of the calibration process.

9

The initial conditions required by the model include, (14) xJs=so = RcosO (15)

(16) uJ = 9..2._ cos(}

s=so ho

, (17) vJ

, s=so =9..2._

b sin (}

0 , and (18)

Tlls=so = To (19)

This system of differential equations, auxiliary equations, and initial conditions comprise a first-order, initial-value problem that can be integrated from the diffuser slot outlet (s = so) to any point along the plume trajectory. Note in the above that R is the radius of the diffuser conduit, bo is the effective width of the diffuser slot, 0 is the exit angle of the diffuser jet, To is the temperature of effluent issuing from the slot, and qo is the effluent discharge per unit length of diffuser. In practice, integration of the governing equations is halted when the jet centerline reaches a point five feet below the water surface (the regulatory compliance depth) or when the upper boundary of the jet reaches the water surface. The jet temperature, 1j, at this point is reported as the fully-mixed temperature to which the thermal regulatory criteria are applied or to which monitoring station data at the edge of the regulatory mixing zone are compared. The integration is done with an adaptive step-size, fourth-order Runge-Kutta algorithm.

In the model, Station 13 (Figure 2), located 1.1 miles upstream of the diffusers, is used to represent the temperature bf the water entrained in the mixing zone, Te = Triver (y) . Whereas this is a good assumption for river flows where the effluent plume is carried downstream, it weakens for low river flows. Based on the understanding gained in recent studies (TVA, 2009), it is known that partial re-entrainment of the effluent plume occurs at sustained low river flow, increasing the temperature of the water entering the mixing zone above that represented by Station 13. To simulate this phenomenon, the model modifies the Station 13 temperature profile for low river flows. For each point in the profile, a local densimetric Froude number is computed as (20)

F,. = -.=g=(=P=e=;=,:='~=iv=r=(z=e=_=z=b=) ,

10

where Uriver is the average river velocity, Ze-Zb is the elevation of the profile point relative to the bottom elevation of the river, pe is the entrainment water density at that elevation, and pp is the density of the effluent plume at the 5-foot compliance depth. The densimetric Froude number represents the ratio of momentum forces to buoyancy forces in the river flow. If Fr is less than 1.0 (i.e., buoyancy greater than momentum), it is assumed that the buoyancy of the plume is sufficient to cause* part of the plume to travel upstream and become re-entrained into the flow, thereby increasing the temperature of the water entering the mixing zone. 'The modified entrainment temperature T/1 at each point in the Station 13 profile is computed by repeatedly evaluating (21) for values of n from 1 to N, where N is the number of iterations of Eq. (21), R is a re-entrainment fraction, Ten=O is the original Station 13 temperature, and Tp is the computed plum~ temperature at the 5-foot depth. N and Rare functions of the 24-hour average river velocity. After new Station 13 temperatures have been computed for the entire profile, the mixing zone computation is performed again, using the modified profile to get a new plume temperature at the 5-foot depth. It is emphasized that the final result of the model is the computed temperature at the downstream end of the mixing zone. The instream temperature *rise is still computed based on the temperature measurement at the new ambient temperature monitor, Station 14.

Values for N and R are calibrated based on observed temperatures at the downstream end of the diffuser mixing zone for low river flow conditions, as indicated earlier. Depending on the river stage, the modifications by Equation 21 begin to take effect as the 24-hour average river flow drops through the range of 17,000 cfs to 25,000 cfs, and increases as the 24-hour average river flow continues to drop. For river flows above this range, no modification is needed for re-entrainment.

The downstream temperature and instream temperature rise provided by the model are computed every 15 minutes, using instantaneous values of the measured diffuser discharge temperature (Station 12), measured upstream temperature profile (Station 13), measured ambient temperature (Station 14), measured river elevation (Station 13), and computed values of the river velocity (one-dimensional unsteady flow model of Chickamauga Reservoir) and diffuser discharge. The diffuser discharge is computed based on the difference in water elevation between the SQN diffuser pond (Station 12) and the river (Station l3). All computations are performed every 15 minutes to provide rolling hourly and 24-hour average values. The hourly averages are based on the current and previous four 15-minute values, whereas the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> averages are based on current and previous ninety-six 15-minute values. The temperature rate-of-change is determined slightly different, being computed every 15 minutes based on current 24-hour average river conditions and current 15-minute values of the flow and temperature of water discharging from the SQN diffusers.

This method was adopted in August 2001 in order to distinguish between rate-of-change events due to changes in SQN operations (i.e. changes in plant discharge flow and/or temperature) and those due to non-SQN changes in operations (e.g., changes in river flow). Prior to this change, SQN was held accountable for temperature rate-of-change events over which it had very little control or influence.

11

Plume Entrainment Two empirical relationships for the plume entrainment coefficient are available in the numerical model. The first, developed by McIntosh, was inferred from a relationship for the entrainment coefficient determined from the data reported in 1983 (TVA, 1983a) and is 'given by 0.55 for Fd<0.75 oc = ~; for 0. 75 ::S Fd ::Sl.00 , (22)

{

0.27 for Fd> 1.00 where Fd is the densimetric Froude number of the diffuser discharge defined by (23)

The term Wd is the velocity of the diffuser discharge, g is the gravitational constant, bo is the diffuser slot width, pd is the density of the diffuser discharge, and po is the density of the ambient river water at the discharge depth.

The second entrainment coefficient, based on laboratory data, was originally developed by Benton in 1986 and is given by a= 0_31 + L 69[1 + tanh(6.543 ;rmf -2.0584)], (24) where rmf = u;;,.., I b , (25) and (26)

Term Uriver is the ambient river velocity, as previously defined, Qo is the diffuser discharge flowrate, and l is the length of the ported section of the diffuser.

12

Diffuser Effluent Re-Entrainment Partial re-entrainment of the diffuser plume is known to occur under conditions oflow river flow.

When the diffuser plume attempts to entrain an amount of ambient flow greater than what is available from further upstream, the upper portions of the plume tend to migrate upstream and plunge downward to be mixed with the flow in the lower portion of the river. The formulation to simulate this phenomenon was presented earlier (Eqs. 20 and 21 ). The unknown coefficients to be determined in the calibration process are the number of iterations N and re-entrainment fraction R in Eq. (21), which are functions of the 24-hour average river velocity.

CALIBRATION The numerical model is calibrated to achieve the best match between computed downstream temperatures and field measurements at the downstream end of the mixing zone. Field measurements at the downstream end of the mixing zone are of two types-those including samples from field surveys across the entire width of the mixing zone and those from Station 8, which includes samples only at the left-hand comer of the mixing zone (e.g., see Figure 2). Higher priority is given to matching data from field surveys, since such measurements are made across the entire width of the plume mixing zone and are more representative of the average temperature in the thermal plume at the 5-foot compliance depth.

Previous Calibration Data and Calibration Work Prior to the NPDES permit of June 2015, field surveys were performed in 1981, 1982, 1983, 1987, 1996, 1997, 1999, 20,00, 2002, 2003, 2004, 2006, 2007, and 2012. In July 1981, TVA conducted the first field survey of the SQN thermal discharge (TV A, 1982). The results of the field surveys were compared to projections from modeling relationships developed from mixing theory and a physical model test of the discharge diffusers. Adequate agreement was achieved between measured data and model projections. In cases where there were discrepancies, the model under-predicted the observed dilutions (i.e., over-predicted temperatures).

Between April 1982 and March 1983, five field surveys containing seventeen sets of samples.

  • across the downstream end of the mixing zone were performed to acquire data for validation of the comput~d compliance technique (TVA, 1983a). The results of these surveys are given in Table

. 2. Only one SQN unit was operating during the March 1983 test-the other five tests were for operation with two units. The results of the numerical model compared favorably with the field-measured downstream temperatures. On average, the discrepancy between the measured and computed downstream temperatures was about 0.40 F° (0.22 C 0 ). Since the accuracy of the temperature sensors used by TVA are only about +/-0 .25 F° (+/-0 .14 C0 ) , the agreement between the field measurements and the computer model was considered good. A similar comparison between the Station 8 and Station 11 temperatures and the measured average temperatures across the downstream edge of the mixing zone revealed that the discrepancy for Station 8 was about 0.79 F 0 (0.44 C 0 ) and for Station 11 about 0.65 F 0 (0.36 C0 ). Consequently, it was concluded that the 13

numerical model is not only an accurate representation of the downstream temperature but also is likely superior to the monitoring approach using Station 8 and Station 11.

In September 1987, TVA released a report describing the field surveys in support of the validation and calibration of the SQN numerical model that had been performed up to that date (TVA; 1987).

In the report, a chart was introduced that described the ambient and operational conditions for which field surveys had been performed. This chart indicated combinations ofriver flow, season,

_and number of operating units, showing what tests had been performed, and assigning relative priorities for tests to be performed in the future. With this guidance, six more field surveys were performed between March 1996 and April 2003, to measure downstream temperatures for various river flows and at different times of year. The results of these surveys produced ten sets of samples across the downstream end of the mixing zone, as given in Table 3.

Between 2004 and 2012 a number of additional field surveys were performed, providing twenty-four more sets of samples containing temperature measurements across the downstream end of the diffuser mixing for various river flows and at different times of the year. The results of these surveys are given in Table 4.

Table 2. Thermal Surveys at SQN from April 1982 through March 1983 River Temperatures (5-foot depth)

Approx Tu Td .:iT Date Flow Stage Time Measured Measured Measured (cfs) (ft MSL)

(Of) (Of) (OF) 04/04/1982 0900 CST 19900 676.46 56.8 61.9 5.1 04/04/1982 1000 CST 19800 676.46 56.7 60.1 3.4 04/04/1982 1100 CST 19600 676.47 56.7 61.2 4.5 04/04/1982 1200 CST 19700 676.50 57.2 61.9 4.7 04/04/1982 1300 CST 19700 676.45 57.4 62.2 4.8 05/14/1982 0900 CDT 7200 682.43 74.5 71.8 -2.7 05/14/1982 1100 CDT 9100. 682.40 73.4 71.8 -1.6 05/14/1982 1300 CDT 6300 682.42 72.1 73.6 . 1.5 09/02/1982 1400 CDT 38500 680.30 78.1 80.1 2.0 11/10/1982 1300 CST 36200 677.57 59.0 60.1 1.1 11/10/1982 1400 CST 31600 677.59 59.0 60.6 1.6 11/10/1982 1500 CST 32300 677.58 59.0 60.4 1.4 03/31/1983 1100 CST 9800 676.34 51.4 54.3 2.9 03/31/1983 1200 CST 9400 676.34 50.4 54.7 4.3 03/31/1983 1300 CST 9300 676.34 52.5 54.5 2.0 03/31/1983 1400 CST 9500 676.34 51.4 54.9 3.5 03/31/1983 1500 CST 9400 676.36 51.4 54.9 3.5 14

Table 3. Thermal Surveys at SQN from March 1996 through April 2003 River Temperatures (5-foot depth)

Approx Tu Td LiT Date Flow Stage Time Measured Measured Measured (cfs) (ftMSL)

(OF) (OF) (OF) 03/01/1996 1100 CST 42456 676.96 45.9 48.8 2.9 03/01/1996 1445 CST 28136 677.04 46.2 50.2 4.0 03/01/1996 1600 CST 21962 677.00 46.1 51.4 5.3 03/01/1996 1700 CST 20280 677.00 46.0 51.5 5.5 07/24/1997 1550 CDT 40441 682.57 83.5 84.7 1.2 03/24/1999* 1250 CST 35731 677.46 51.9 54.5 2.7 08/02/2000 1000 CDT 12472 682.20 82.1 85.1 3.0 08/02/2000 1100 CDT 8624 682.20 82.1 85.3 3.1 07/27/2002 1250 CDT 17231 682.37 84.0 86.6 2.6 04/23/2003 1445 CDT 34178 682.53 63.7 64.2 0.5

  • The survey of03/24/1999 is lacking valid upstream temperature data and was not used in the calibration.

Table 4. Thermal Surveys at SQN from February 2004 through November 2012 River Temperatures (5-foot depth)

Approx Tu Td LiT Date Flow Stage Time Measured Measured Measured (cfs) (ftMSL)

(OF) (°F) (OF) 02/14/2004 0600 CST 51133 677.50 43.7 46.3 2.6 02/22/2004 1800 CST 18468 678.40 45.8 50.5 4.7 08/22/2004 1800 CST 12340 682.00 79.8 84.1 4.3 08/23/2004 1800 CST 39238 682.20 79.8 82.4 2.6 04/01/2006 1915 CST 7084 677.20 59.7 63.5 3.8 04/04/2006 0015 CST 7996 677.70 59.3 1 63.9 4.6 04/04/2006 1105 CST 8251 677.80 59.6 61.3 1.7 04/04/2006 2030 CST 8258 678.00 59.0 63.2 4.2 04/05/2006 0915 CST 7917 678.20 59.2 62.8 3.6 04/05/2006 2215 CST 8277 678.40 60.4 64.2 3.8 '

04/06/2006 0915 CST 8174 678.50 59.7 63.3 3.6 04/06/2006 2315 CST 8077 678.70 61.0 64.5 3.5 04/07/2006 0840 CST 8162 678.80 59.9 63.9 4.0 04/07/2006 1435 CST 7889 678.80 60.0 64.7 4.7 05/22/2006 1445 CST 14511 682.00 .* 73.4 72.9 -0.5 05/23/2006 1455 CST 17878 682.20 73.5 73.9 0.4 05/28/2006 1440 CST 13396 682.30 76.6 76.7 0.1 05/29/2006 1435 CST 13713 682.40 77.5 77.6 0.1 05/30/2006 1425 CST 14304 682.40 79.7 79.2 -0.5 09/20/2007 1200 CST 8545 681.80 79.3 83.4 4.1 09/21/2007 1300 CST 8629 681.70 80.6 82.5 1.9 09/22/2007 0600 CST 6969 681.70 79.5 81.8 2.3 11/04/2007 1200 CST 7664 678.70 64.9 69.5 4.6 11/16/2012 1400 CST 12599 678.62 57.0 60.3 3.3 15

The most recent calibration of the numerical model was performed in 2013 to support the NPDES permit of March 2011 (TVA, 2013). The data from Table 2, Table 3, and Table 4 were used in this calibration. The average overall discrepancy between the measured and computed downstream temperatures was about 0.55 F0 (0.31 C0 ). For downstream temperatures above 75°F, the average discrepancy improved to about 0.38 F0 (0.21 C 0 ).

New Calibration Data and Calibration Work Since the 2013 model calibration, an additional field study was performed in August 2018 (Table 5). The study included the operation of two units at SQN and was conducted concurrently with independent measurements for the discharge through the diffusers (TVA, 2018). Measured data of downstream temperatures was collected for a 6-hour period at 5 locations which were spread equally across the entire end of the mixing zone. Those five locations were averaged across the 3 foot, 5 foot, and 7 foot depths. With this, altogether fifty-one data points with sets of temperature samples across the downstream end of the mixing zone were available for updating the model calibration (i.e., Table 2 through Table 5).

Table 5. Thermal Surveys at SQN from August 2018 River Temperatures (5-foot depth)

Approx Tu Tct ~T

\ Date Flow Stage Time Measured Measured (cfs) (ftMSL) Measured

{°F) (OF) (OF) 08/22/2018 1600 CST 12531 682.70 81.9 84.0 2.1 Diffuser Slot Width The effective slot width for a multiport diffuser of the type at SQN can be assumed to fall somewhere between the width of a rectangle with length equal to that of the diffuser section and area equal to the total area of the ports; and the width a rectangle with length equal to that of the diffuser section and area equal to the arc length of the perforated section of the diffuser. For the SQN diffuser, this ~lot width would be between 0.37 feet and 2.67 feet. Multiple slot widths in this range were evaluated and compared with fifty-one measured data points from the field surveys (i.e., from Table 2 through Table 5). The results, given in Figure 6, show that larger slot widths yielded better agreement with the measured data. T_pe nominal arc length of the perforated section of the diffuser (i.e., 2.67 feet) was selected as the best diffuser slot width to be used in the numerical model. This is the same value used in the 2009 model calibration.

Plume Entrainment Coefficient Figure 7 shows the comparison with measured data of downstream temperatures computed with the McIntosh (Eq. 22) and Benton (Eq. 24) entrainment coefficients, again based on fifty-one data 16

points from the field surveys in Table 2 through Table 5. Both entrainment coefficients result in relatively close matches with the measured data. Although the McIntosh coefficient seems to perform better at low ambient river temperatures, temperatures computed using the Benton coefficient more closely match measured downstream temperatures at higher river temperatures.

Since the accuracy of the computation is more critical at temperatures approaching the NPDES limit for downstream temperature, the Benton coefficient, Eq. (24) is used in the compliance model.

Field Data - 1982 - 2018 90

-Line of perfect agreement BO = 0.37 ft 85

  • BO =1.137 ft
  • BO= 1.903 ft 80 BO= 2.67 ft
  • BO = 3.437 ft 75 t.10 "O

Cl)

i Q.

65 E

8 60 55 50 50 55 60 65 70 75 80 85 90 Measured (°F)

Figure 6. Sensitivity of Computed Temperature Tct to Diffuser Effective Slot Width 17

Field Data - 1982-2018 90 I

- L i ne of perfect agreement 1., 1 ~

85 >---

  • Benton Entrainment Coefficient 80

... McIntosh Entrainment Coefficient

~<I A,? ..

[

75 70 y.

"C aE 65 I~

0

(.)

60

~;

55

/-

50

!/*

ye 1,7 -

45 45 - 50 55 60 65 70 75 80 85 90 Measured (°F)

Figure 7. Sensitivity of Computed Temperature T ct to Plume Entrainment Coefficient Diffuser Effluent Re-Entrainment Based on the evaluation of numerous combinations of N and R for diffuser effluent re-entrainment (Eq. 20 and 21 ), Table 6 gives the values that resulted in computed downstream temperatures that most closely matched measurements in the field surveys (i.e., fifty -one data points from Table 2 through Table 5). For river velocities between the values given in Table 6, the re-entrainment factor R is interpolated between the table values. The number of iterations N is interpolated and then rounded to the nearest integer. No re-entrainment correction is performed for 24-hour river velocities greater than the highest value in the table.

Figure 8 shows the comparison of measured and computed downstream temperatures with and without the correction for plume re-entrainment as given in Table 6. Temperatures computed using the plume re-entrainment correction more closely matched measured values for twenty-eight of the fifty -one data points. Temperatures computed without using the plume re-entrainment correction more closely matched measured values for six data points, with no significant differences for the remaining data points. Based upon these results the re-entrainment correction method is used.

18

Table 6. Plume Re-Entrainment Iteration Numbers and Factors River Velocity Number of Iterations Re-entrainment Factor (ft/sec) N R 0.000 3 0.21930 0.050 3 0.13300 0.075 3 0.11000 0.100 3 0.10000 0.200 3 0.02670 0.300 3 0.03507 0.400 3 0.00893 0.500 3 0.00447 0.600 0 0.00000 Field Data - 1982-2018

-Line of perfect agreement 85

  • Using Plume Reentrainment 80
  • Not Using Plume Reentrainment LL 0
; 70 1 - - - - - t -- - - + - - - --+-- -- 1--- --,..,;,r.- - - - 1f--- - - + - - - - - I - - ---:

~

I
c. 65 E

0 u 60 45 ~..._...__..__,__........._._..__..__,.__.__._...__..__,__........._._..__..__~_..__.__._-l-...__..__,__........._J_..__..__........___,____..~---...1_..__..__........_....,

45 50 55 60 65 70 75 80 85 90 Measured (°F)

Figure 8. Sensitivity of Computed Temperature Tct to Effluent Re-Entrainment Function 19

Results of Updated Calibration For the assumed diffuser slot width and entrainment coefficient, and updated calibration including the re-entrainment function for low river flow, the computed and measured downstream temperatures for the fifty-one downstream temperature data points collected in SQN field surveys since March 1982 are shown in Figure 9. The average discrepancy between the measured and computed downstream temperatures was about 0.55 F° (0.31 C 0 ). For downstream temperatures above 75°F, the average discrepancy was 0.38 F° (0 .21 C 0 ). There was no significant change in the model performance compared to the previous calibration.

To be consistent with the 24-hour averaging specified in the current NPDES permit, the 24-hour average temperatures measured in 2010 at the downstream temperature monitor, Station 8, are compared to those computed by numerical model in Figure 10. 20 l O was selected because it represents a new climatic extreme in East Tennessee for the period of record for this model. As before, the measured temperatures correspond to the average of sensor readings at the 3-foot, 5-foot, and 7-foot depths. The overall average discrepancy between the measured and computed 24-hour average downstream temperatures was about 0.71 F0 (0 .39 C 0 ) , and about 0.63 F° (0.35 C 0 )

for downstream temperatures above 75°F.

Measured downstream hourly average temperatures for the same time period are compared to those computed by numerical model in Figure 11. As expected, the temperature data are much more scattered for the hourly temperatures. The average discrepancy between the measured and computed hourly average downstream temperatures was 0.86 F° (0.48 C0 ) for the full range ofriver temperatures, decreasing to 0. 71 F0 (0.39 C0 ) for downstream temperatures above 75°F.

It needs to be emphasized that in Figure 10 and Figure 11, the data from Station 8 is not necessarily representative of the average temperature across the downstream end of the mixing zone.

However, in monitoring the NPDES compliance for Outfall 101, data from Station 8 is considered valuable for verifying basic trends in the downstream temperature as determined by the numerical model, thus providing the motivation for presenting the comparisons given in these figures.

20

90

-Line of perfect agreement 85

  • Field Data 1982 - 2018 80 75 ii:'

~

"C 70

.!!l

I C.

E 65 0

u 60 55 50 45 45 50 55 60 65 70 75 80 85 90 Measured (°F)

Figure 9. Comparison of Computed and Measured Temperatures Td for Field Studies from April 1982 through August 2018 90 85 -Line of perfect agreement 80

  • Measured 2010 75 70 ii:'

~

'C 65

.!!l

I C.

E 60 0

u Erroneous data due to faulty 55 sensor--values removed fro m di screpancy calcul ati ons 50 45 40 40 45 50 55 60 65 70 75 80 85 90 Measured (°F)

Figure 10. Comparison of Computed and Measured 24-hour Average Temperatures Td for Station 8 for 20 I 0 21

90 85 -Line of perfect agreement 80

  • Measured 2010 75 70

[

"t)

.El 65

l C.

E 0

(.) 60 55 di screpancy calculations 50 45 40 40 45 50 55 60 65 70 75 80 85 90 Measured (°F)

Figure 11. Comparison of Computed and Measured Hourly Average Temperatures T ct for Station 8 for 2010 22

CONCLUSIONS The numerical model for the SQN effluent discharge computes the temperature at the downstream end of the mixing zone with sufficient accuracy for use as the primary method of verifying thermal compliance for Outfall 101. In the updated calibration study summarized herein, which used the results from fifty-one sets of temperature samples across the downstream end of the diffuser mixing zone, the average discrepancy between the measured and computed downstream temperatures was about 0.55 F0 (0.31 C0 ). For downstream temperatures above 75°F, the average discrepancy improved to about 0.38 F° (0.21 C0 ) . There was no significant change in the model performance compared to the previous calibration, and as a result, no update was required in the model parameter set.

23

REFERENCES Benton, D.J. (2003), "Development of a Two-Dimensional Plume Model," Dynamic Solutions, LLC, Knoxville, Tennessee, May 2003.

Fischer, H.B., E. J. List, R. C. Y. Yoh, J. lmberger, and N. H. Brooks (1979), Mixing in Inland and Coastal Waters, Academic Press: New York, 1979.

TDEC (2005), "NPDES Permit No. TN0026450, Authorization to discharge under the National Pollutant Discharge Elimination System (NPDES)", Tennessee Department of Environment and Conservation, Division of Water Pollution Control, Nashville, Tennessee 37243-1534, July 29, 2005.

TDEC (2011), "NPDES Permit No. TN0026450, Authorization to discharge under the National Pollutant Discharge Elimination System (NPDES)", Tennessee Department of Environment and Conservation, Division of Water Pollution Control, Nashville, Tennessee 37243-1534, January 31, 2011.

TVA (1982), McIntosh, D.A., B.E. Johnson, and E.B. Speaks, "A Field Verification of Sequoyah Nuclear Plant Diffuser Performance Model One-Unit Operation," TVA Division of Air and Water Resources, Water Systems Development Branch, Report No. WR28 45-l I 0, October 1982.

TVA (1983a), McIntosh, D.A., B.E. Johnson, and E.B. Speaks, "Validation of Computerized Thermal Compliance and Plume Development at Sequoyah Nuclear Plant,"

Tennessee Valley Authority, Division of Air and Water Resources, Water Systems Development Branch Report No. WR28-l-45-l 15, August 1983.

TV A ( 1983b), Waldrop, W.R., and D .A. McIntosh, Real-Time Computation ofCompliance with Thermal Water Quality Standards, Proceedings of Microcomputers in Civil Engineering, University of Central Florida, Orlando, Florida, November 1983.

TVA (1987), Ostrowski, P ., and M.C. Shiao, "Quality Program for Verification of Sequoyah Nuclear Plant Thermal Computed Compliance System," Tennessee Valley Authority, Office of Natural Resources and Economic Development, Division of Air and Water Resources Report No. WR28-3-45-I34, September 1987.

TVA (2003), Harper, W.L., "Study to Confirm the Calibration of the Numerical Model for the Thermal Discharge from Sequoyah Nuclear Plant as Required by NPDES Permit No.

TN0026450 of August 2001, Report No. WR2003-1-45-149, Tennessee Valley Authority, River Operations, June 2003.

24

TVA (2009), Harper, W.L. and P.N. Hopping, "Study to Confirm the Calibration of the Numerical Model for the Thermal Discharge from Sequoyah Nuclear Plant as Required by NPDES Permit No. TN0026450 of September 2005, Report No. WR2009-l-45-150, Tennessee Valley Authority, River Operations, January 2009.

TVA (2009), "Ambient Temperature and Mixing Zone Studies for Sequoyah Nuclear Plant as Required by NPDES Permit No. TN0026450 of September 2005," Report No. WR2009-1-45-151, Tennessee Valley Authority, River Operations, January 2009.

TVA (2010), "Sequoyah Nuclear Plant (SQN) - Revised Thermal Performance Baseline and Capacity Ratings," Memo from Scott D. Terry to J.D. Williams (885100419001),

April 14, 2010.

TVA (2013), Boyington, T.M., P.N. Hopping, and W.L. Harper, "Study to Confirm the Calibration of the Numerical Model for the Thermal Discharge from Sequoyah Nuclear Plant as Required by NPDES Permit No. TN0026450 of March 2011, Report No. WR2013-1-45-152, Tennessee Valley Authority, River Operations & Renewable, April 2013.

TVA (2018), "Sequoyah Nuclear Plant (SQN)--Update of Flowrate Characteristics Through the Diffusers," Memo from Colleen Montgomery to Millicent M. Garland, September 5, 2018.

25