ATTACHMENT 1 Consumers Power Company Palisades Plant Docket 50-255 PROPOSED TECHNICAL SPECIFICATION PAGE CHANGES August 2, 1989 89b8100220 890802 PDR ADOCK 05000255 P PDC 1 Page

\\

l \'

TSP0789-0150-NL04

  • Table 4.2.2
  • Minimum Frequencies for Equipment Tests FSAR Section Test Frequency Reference
1. Control Rods Drop Times of All Full- Each Re- 7.4.1.3 Length Rods fueling Shutdown
2. Control Rods Partial Movement of All Every Two 7.4.L3 Rods (Minimum of 6 In) Weeks
3. Pressurizer Safety Set Point One Each 7.3.7 Valves Refueling Shutdown
4. Main Steam Safety Set Point Five Each 4.3.4 Valves Refueling Shutdown
5. Refueling System Functioning Prior to 9.11.3 Interlocks Refueling Operations
6. Service Water System Functioning Each Re- 9 .1. 2 Valve Actuation fueling (SIS-CHP) Operation
7. Fir~ Prot~ction Functioning Monthly 9.6.2 Pumps and Power Supply
8. Primary System Evaluate Daily 4 Leakage Amend 15, Ques 4.3.7
9. Diesel Fuel Supply Fuel Inventory Daily 8.4.1
10. (Deleted) I 4-15 Amendment No ll, Sl, TSP0789-0150-NL04

ATTACHMENT 2 Consumers Power Company Palisades Plant Docket 50-255 MARKED UP TECHNICAL SPECIFICATION PAGE August 2, 1989 1 Page TSP0789-0150-NL04

... *.*., . ~

...- ......

  • Table 4.2.2

.-~

Minimum Frequencies for Equipment Tests

  • Fs*AR Section Test Frequency Reference 1 *. Control Rods Drop Times of All Full- Each Re- 7.4.1.3 Length. Rods fueling Shutdown
2. Control Rods Partial Movement of All Every Two 7.4.l'.3.

Rods (Minimum of 6 In) Weeks

3. Pressurizer Safety Set Point One Each 7.3.7 Valves Refueling Shutdown
4. Main Steam Safety Set.Point Five Each 4.3.4':'

Valves Refueling Shutdown

5. Refueling System Functioning * *
  • Prior to 9.11.l
  • Interlocks Refueling Operation_!;J
6. Service Water System Functioning Each Re- 9*. l. 2*

Valve.Actuatio~ fueling (SIS-CHP) Operation

7. Fire Protection Functioning Monthly 9.6.2
  • Pumps and Power Supply
8. Primary System Evaluate Daily 4 Leakage Amend 15 ,"

Ques 4.3 .* 7 Daily* 8.4;1

  • E:!f::Y *.~* I 4-15 Amendment No TSP1086-0147A-NL04