Category:Deficiency Correspondence (per 10CFR50.55e and Part 21)
MONTHYEARML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML19080A0592019-03-0808 March 2019 Interim Report of Potential 10CFR Part 21, Eaton A200 Series Starters/Contactors ML18263A2812018-09-20020 September 2018 (Waterford 3) - Part 21 Report of Westinghouse 7300 Circuit Card Increased Failure Rate ML17325B0222017-11-17017 November 2017 Fisher Controls International LLC Information Notice (FIN) 2017-05 ML17192A2652017-06-30030 June 2017 Areva Np, Inc. - Closure of Interim Report of an Evaluation of a Deviation Pursuant to 10 CFR 21.21(a)(2) ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML16252A2742016-08-29029 August 2016 Azz/Nli - Part 21 Report - Potential Allen Bradley Timing Relay ML15243A1742015-08-25025 August 2015 Part 21 Furmanite Nuclear Grade Leak Seal Material FSC-N-1B ML15134A0162015-05-0101 May 2015 Part 21 Report Regarding Potentially Unqualified Component in Certain Allen Bradley Timing Relays ML15089A4362015-03-21021 March 2015 Part-21 Report - Valve Seat Leakage Defect W3F1-2014-0069, Part 21 Report of Time-Delay Relay Failure2014-11-12012 November 2014 Part 21 Report of Time-Delay Relay Failure W3F1-2014-0042, Part 21 Report of Pneumatic Valve Actuator Reverse Action2014-07-0909 July 2014 Part 21 Report of Pneumatic Valve Actuator Reverse Action W3F1-2014-0026, Notification of Potential Part 21 Report of Time-Delay Relays Spurious Actuation2014-04-11011 April 2014 Notification of Potential Part 21 Report of Time-Delay Relays Spurious Actuation ML14107A1612014-04-0909 April 2014 Qualtech Np Response to 10CFR Part 21 Notification on Allen Bradley Timing Relays, Event # 49911, Docket No. 99901414 ML14079A0282014-03-13013 March 2014 Part 21 - Allen Bradley Type 700RTC Relay Spuriously De-Energizing ML14069A4672014-02-26026 February 2014 Part 21 Report Involving a Potential Manufacturing Defect in Replacement Masterpact Cradles ML13246A0872013-08-23023 August 2013 Nuclear Nonconformance Event Number 49302 - 10CFR21 Notification ML13165A3422013-06-12012 June 2013 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers ML12094A3712012-04-0202 April 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12066A1182012-03-0202 March 2012 Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations ML12097A3162012-03-0202 March 2012 Part 21 Report - Rosemont Pressure Tranmitters Out of Tolerance Condition ML0934301402009-12-0202 December 2009 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 1OCFR21-0098, Rev. 0, Amot Thermostatic Valve Element, P/N: 9760X ML0923900432009-08-25025 August 2009 Notification of Potential Part 21 Report Due to Radiation Monitor Defect ML0907611882009-03-11011 March 2009 Part 21 Notification - Defective Hk and K-Line Circuit Breaker Tension Springs ML0723304752007-08-14014 August 2007 Rosemount 1154 Pressure Transmitter Calibration Problem L-75-426, Letter Regarding a Reportable Incident Under 10 CFR 50.55(e) Relating to a Split Flange on Intake Cooling Water Line and Requesting Postponement of This Report Until October 6, 19751975-09-0909 September 1975 Letter Regarding a Reportable Incident Under 10 CFR 50.55(e) Relating to a Split Flange on Intake Cooling Water Line and Requesting Postponement of This Report Until October 6, 1975 L-75-388, Letter Regarding the Construction Incident Report (Final) Steam Generator 1B1 Primary Head Clad1975-08-0505 August 1975 Letter Regarding the Construction Incident Report (Final) Steam Generator 1B1 Primary Head Clad L-75-197, Letters Regarding an Interim Report Concerning a Crack Discovered in the East Wall of the Refueling Canal of Unit 1 and Requesting an Extension of Time for Submission of Reports on Refueling Wall Crack and Failure of Square D ...1975-04-28028 April 1975 Letters Regarding an Interim Report Concerning a Crack Discovered in the East Wall of the Refueling Canal of Unit 1 and Requesting an Extension of Time for Submission of Reports on Refueling Wall Crack and Failure of Square D ... 2019-03-08
[Table view] Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML23065A2002023-03-0303 March 2023 EN 56252 Update - Flow Serve - Final Notification of Potential Part 21 on Peerless 56 Frame DC Motors ML23030A6642023-01-27027 January 2023 Flowserve, Part 21 Second Interim Notification Report Re Peerless 56 Frame DC Motors ML22342B1402022-12-0202 December 2022 56252-EN 56252 - Flowserve - Limitorque - Interim Report Potential Part 21 on Peerless 56 Frame DC Motors ML21271A2342021-09-23023 September 2021 EN 55282 (Updated) - Framatome Part 21 Reportable Defect - Vacuum Breakers ML21225A0812021-08-0404 August 2021 Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML21014A2342020-12-0707 December 2020 Fourth Interim Notification Per 10 CFR Part 21 Re Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML20304A1612020-10-14014 October 2020 Lake Engineering Co., Degraded Snubber SF1154 Hydraulic Fluid Batch No. 16DLVS852 Final Report Per 10 CFR Part 21 ML20097B6912020-03-20020 March 2020 Second Interim Notification Per 10 CFR Part 21: Degraded Snubber SF1154 Hydraulic Fluid Batch No. 16DLVS852 ML20108F5302020-03-20020 March 2020 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0129, Rev. 0, Test Stand Deficiency - EMD Fuel Injectors P/N H40084720 ML19347A4262019-12-10010 December 2019 General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) ML19317D0932019-10-25025 October 2019 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10 CFR21-0127, Rev. 0, Emd Fuel Injectors - Seized Plunger and Bushing ML19253A0532019-08-29029 August 2019 Azz Nuclear - Report of Potential 1O CFR Part 21, Eaton Size 1 and 2 A200 Series Starters/Contactors ML19120A1062019-04-17017 April 2019 Interim Report of Potential 10 CFR Part 21, Eaton Size 1 and 2 A200 Series Starters/Contactors ML19080A0592019-03-0808 March 2019 Interim Report of Potential 10CFR Part 21, Eaton A200 Series Starters/Contactors ML19053A5002019-02-0101 February 2019 Sor, Inc. Part 21 Notification of Deviation Sor R-Series Housing with Terminal Block ML18354A7422018-12-0404 December 2018 Engine Systems, Inc., Submittal of 1OCFR21 Reporting of Defects and Non-Compliance - Report No. 1OCFR21-0123, Rev. 0 - Emo Fuel and Soakback Pumps - Potentially Undertorqued Cover Bolts ML18241A0292018-08-23023 August 2018 Hex Inverter Chip on Westinghouse 7300 Process Analog Control System Circuit Cards W3F1-2018-0040, Interim Report of a Deviation or Failure to Comply2018-07-0505 July 2018 Interim Report of a Deviation or Failure to Comply ML18081A1192018-03-15015 March 2018 Rosemount Nuclear Instruments, Inc., Submittal of Notification Under 10 CFR Part 21 for Certain Model 1154 and Model 1154 Serles H Pressure Transmitters and 01154-0153-0002 Amplifier Circuit Card Assemblies ML17325B0222017-11-17017 November 2017 Fisher Controls International LLC Information Notice (FIN) 2017-05 ML17324A9792017-11-17017 November 2017 Part 21 Report Re Fisher Type 461 Valve Plug Machining ML17194A8252017-07-11011 July 2017 Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML16321A4512016-10-21021 October 2016 Part 21 Reporting of Defects and Noncompliance ML16294A2642016-10-18018 October 2016 Part 21 Report - Defective Current to Pressure Transducers ML16278A4712016-09-22022 September 2016 Notification of 10 CFR Part 21 Condition, Masterpact Breaker Fail to Close ML16281A2702016-09-22022 September 2016 Part 21 - Initial Notification of Masterpact Breaker Fail to Close ML16252A2742016-08-29029 August 2016 Azz/Nli - Part 21 Report - Potential Allen Bradley Timing Relay ML16243A4742016-08-26026 August 2016 Potential Part 21 Unqualified Component in Certain Allen Bradley Timing Relays ML16243A4722016-08-25025 August 2016 Part 21 Reporting of Defects and Noncompliance ML16232A6042016-08-15015 August 2016 Potentially Unqualified Component in Certain Allen Bradley Timing Relays ML16238A1862016-08-15015 August 2016 Update - Report of Potential l0CFR Part 21, Allen Bradley Timing Relay Model 700RTC-NRC Event Number 51030, Accession Number ML15134A016 ML16209A0502016-07-13013 July 2016 Part 21 - Furmanite Nuclear Grade Leak Seal Material FSC-N-1B ML16188A3762016-06-21021 June 2016 Part 21 Interim Evaluation of Deviation - Contractor Failure ML16154A2072016-05-26026 May 2016 Part 21, Azz/Nli Nuclear Logistics, Inc., Potentially Unqualified Component in Certain Allen Bradley Timing Relays Model 700RTC ML16194A1992016-05-25025 May 2016 Azz/Nli - Update - Report of Potential 10CFR Part 21, Allen Bradley Timing Relay Model 700RTC ML16139A8322016-05-13013 May 2016 Part 21 - Initial Notification of Masterpact Breaker Fail to Close ML16139A8332016-05-13013 May 2016 Part 21 - Initial Notification of Masterpact Breaker Fail to Close ML16139A8342016-05-10010 May 2016 Electroswitch - Transmittal of 10CFR Part 21 Reporting of Defects and Noncompliance Regarding Vendor Inspection of Electroswitch Corporation Docket No. 99900833 ML16111A4202016-04-0808 April 2016 Part 21 Report No. P21-04302015, Rev. 1 Regarding Potentially Unqualified Component in Certain Allen Bradley Timing Relays, Per Browns Ferry, Ginna, Millstone, Nine Mile Point, North Anna, Ft. Calhoun, Perry, River Bend, South Texas Project ML15303A0042015-10-23023 October 2015 Part 21 Report Regarding Westinghouse Type KIR-60 Current Transformer, Per Waterford, Unit 3 ML15134A0162015-05-0101 May 2015 Part 21 Report Regarding Potentially Unqualified Component in Certain Allen Bradley Timing Relays ML15159A5682015-04-30030 April 2015 Report of Potential 10CFR Part 21, Allen Bradley Timing Relay Model 700RTC ML15103A4852015-04-0707 April 2015 Itt Engineered Valves - 2nd Interim Report to the NRC of 10 CFR 21 Event 50285, Reported by Itt 07/18/14 Concerning M I Diaphragms, Customer Testing ML15089A4362015-03-21021 March 2015 Part-21 Report - Valve Seat Leakage Defect ML15049A4582015-02-0606 February 2015 Thermo Gamma-Metrics, LLC - Part 21 Report Regarding Shutdown Margin Monitor Environmental Qualification Noncompliance ML15022A6502015-01-20020 January 2015 Letter from Steven R. Eisenberg USNRC 10CFR Part 21 Notification W3F1-2014-0069, Part 21 Report of Time-Delay Relay Failure2014-11-12012 November 2014 Part 21 Report of Time-Delay Relay Failure ML14274A0522014-09-22022 September 2014 Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities 2023-03-03
[Table view] |
Text
0312112615 Pnap I 03/21/2015 U.S. Nuclear Repulatnrv Conmmksinn flnerations. Center Event Ronnrt 1---------------------- pay" Part 21 (PAR) Event# 50911 Rep Org: EMERSON PROCESS MANAGEMENT Notification Date I Time: 03/20/2015 14:49 (EDT)
Supplier: FISHER CONTROLS INTERNATIONAL LLC Event Date I Time: 06/06/2014 (CDT)
Last Modification: 03/20/2015 Region: 3 Docket #:
City: MARSHALLTOWN Agreement State: Yes County: License #:
State: IA NRC Notified by: DENNIS SWANSON Notifications: GREGORY ROACH R3DO HQ Ops Officer: MARK ABRAMOVITZ BINOY DESAI R2DO Emergency Class: NON EMERGENCY HEATHER GEPFORD R4DO 10 CFR Section: PART 21/50.55 REACTORS EMAIL 21.21(d)(3)(i) DEFECTS AND NONCOMPLIANCE 50.55(e) CONSTRUCT DEFICIENCY PART-21 REPORT - VALVE SEAT LEAKAGE DEFECT The following is a summary of a submitted facsimile:
"A valve plug originally supplied as a spare parts order was returned to Fisher after the customer discovered a machining error was present on the plug. The Type 461 valve plug has a groove machined across the seating surface of the plug. This groove is required to provide a controlled leak rate thru the valve when the plug is on the seat. The issue recently identified shows that the machined groove did not extend through the full length of the seat. This could lead to a situation in which the intended/required leakage for this design is not fully achieved."
Affected plants are: Waterford-3 and St Lucie.
Mar, 20. 2015 1:13PM No. 0375 P. 1 EMERSON. [FISHE]
Process Management Facsimile 301 South First Ave Marshalltown, IA 50158 T 641-754-3011 F 641-754-2830 To': NRC Operations Center - Alln: Bill Huffman Fax: 301-816-5151 From: Dennis Swanson, Emerson Process Management Date: 03120/20 15 Pages: 4 (inci cover)
Attachment:
Fisher Information Notice - (FIN) 2015-01 For technical questions please contact Dennis Swanson at (641) 754-2381.
Mar. 20. 2015 1:13PM No. 0375 P. 2 EMERSON. Fisher Controls International LLC Process Management 301 South First Ave.
P.O. Box i90 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 March 20, 2015 To Whom It May Concern:
Attached is a Fisher Information Notice, (FIN) 2015-01.
Emerson Process Management - Fisher Valves complies with the reporting requirements of 10 CFR Part 21 Section 21.21 (b) and 10 CFR Part 50.55 (e) by informing the U.S. Nuclear Regulatory Commission Licensees or Purchaser of deviations or failures to comply.
Please review the attached FIN notice for applicability to your facility.
Dennis Swanson Director, Quality Valve Division - Americas Attachments (FISHER]
Mar.2Q. 2015 1:13PM No, 0375 P. 3 4
EMERSON. Fisher Controls International LLC Process Management 301 South First Ave.
P.O. Box 190 Marshalltown, Iowa 50158-0190 USA T (641) 754-3011 F (641) 754-2830 Fisher Information Notice: FIN 2015-01 18 March 2015 Subiect: Fisher Type 461 Valve Plug Machining From:
Chad Engle Director, Nuclear Business Unit Fisher Controls International LLC 301 South 1st Avenue Marshalltown, IA 50158 Fax: (641) 754-2854 Equipment Affected By This Information Notice:
The equipment affected by this FIN notice are replacement Valve Plug/Stem Assemblies for Type 461 valves supplied under the following machining drawing numbers: 25A0413, 29A7841 or 27B5132. Fisher records indicate two sites were supplied the potentially affected assemblies.
Entergy Waterford 3: 29A7841X052 Waterford PO: 10297987 FPL St. Lucie: 25A0413X112,25A0413X122,25A0413X142, 25A0413X162 and 27B5132X022 St. Lucie PO's: 55205, 00109494 Rev 3, 02318525 Rev 2
Purpose:
The purpose of this Fisher Information Notice(FIN) is to alert Entergy and Florida Power and Light that as of 6 June 2014, Fisher Controls International LLC ("Fisher')
became aware of the possibility of a situation which may affect the performance of the applicable equipment.
Fisher is informing the NRC 'of this circumstance in accordance with Section 21.21(b) of 10CFR Part 21.
[FISHER Page 1
Mar.20. 2015 1:13PM No, 0375 P. 4 Fisher Information Notice: FIN 2015-01 Applicability:
This notice applies only to the subject equipment supplied by Fisher as identified above.
Discussion:
A valve plug originally supplied as a spare parts order was returned to Fisher after the customer discovered a machining error was present on the plug. The Type 461 valve plug has a groove machined across the seating surface of the plug. This groove is required to provide a controlled leak rate thru the valve when the plug is on the seat.
The issue recently identified shows that the machined groove did not extend through the full length of the seat. This could lead to a situation in which the intended I required leakage for this design is not fully achieved.
Action Required: Evaluate any affected Type 461 valve plugs in inventory to ensure the machined groove extends across the plug seating area.
U-- ---------------- ......---
VEE 6ROOVE
.A.------ ------
Fisher is revising the affected drawings for increased clarity and implementing appropriate corrective actions per CAR 1727.
IOCFR2I Implications:
Fisher requests that the recipient of this notice review it and take appropriate action in accordance with I OCFR Part 21.
If there are any technical questions or concerns, please contact:
Benjamin Ahrens Manager, Quality Fisher Controls International LLC 301 South 1SIt Avenue Marshalltown, IA 50158 Fax: (641) 754-2854 Phone: (641) 754-2249 Beniamin.Ahrens(@Einerson.com Lln. E! !H 0 rn*u _ uItn.