IR 05000295/1988008

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Repts 50-295/88-08 & 50-304/88-09 on 880201-19.Violation Noted.Major Areas Inspected: Circumstances Surrounding Inadequate Search of Package Matl Observed on 880201
ML20147G177
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 03/02/1988
From: Creed J, Drouin B, Hare S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20147G149 List:
References
50-295-88-08, 50-295-88-8, 50-304-88-09, 50-304-88-9, NUDOCS 8803080154
Download: ML20147G177 (1)


Text

.

m .-_t , , . , ,

m . W

"

,

.U. S. NUCLEAR REGULATORY COMMISSION REGION III.'

,

' Reports No. 50-295/88008(ORSS); . 50-30'4/88009(ORSS)

Docket.Nos. 50-295;_50-304 Licenses No. OPR-39; DPR-48'.

-Licensee: Commonwealth Edison Company P; 0.. Box 767-

,

Chicago, IL 60690 Facility Name:

~

Zion Nuclear Station, Units 1 and 2

. Inspection At: Zion Station, Zion ~, Illinois Inspection Conducted: _ February 1 (onsite) through

-

February 19, 1988 (Region III office)

Type of. Inspection: Routine Security Inspection

,

Date of Last Security Inspection November 16-20, 1987 Inspectors: b u 1- h o3- oz. 88 are V 'Date LicenAing-b iner-N' / U B LIlro61nr / Da% /

Physical Security Inspector Approved By: bk '

mes R. Creed, Chief Date feguards Section Inspection Summary Inspection on February 1 through 19, 1988 (Reports No. 50-295/88008(DRSS);

No. 50-304/88009(DRSS))-

Areas Inspected: The special inspection reviewed the circumstances surrounding the inadequate search of packaged material which was observed on February 1,198 Results: One violation was identified and is described below:

Access Control Packages: A package entering the Protected Area was not searched as require (Details: UNCLASSIFIED 5AFEGUARDS INFORMATION) Enclosure contafns ggj3 ] 8 $ $$o3o3 o00295 PDR Upon separation this a page is Decontrolled