Category:Inspection Report
MONTHYEARIR 015000004/20230022023-06-21021 June 2023 California Institute of Technology - NRC Form 591M, Inspection Report 150-00004/2023-002 IR 015000004/20220042022-12-0606 December 2022 J.L. Shepherd & Associates, NRC Form 591M Part 1, Inspection Report No. 150-00004/2022004 IR 015000004/20220032022-05-0303 May 2022 J. L. Shepherd, NRC Form 591M Part 1, Inspection Report No. 15000004/2022003 IR 015000004/20220012022-02-0909 February 2022 J.L. Shepherd & Associates, NRC Form 591M Part 1, Inspection Report 15000004/2022001 IR 015000004/20210022022-01-20020 January 2022 J.L. Shepherd Associates, NRC Form 591M Part 1, Inspection Report 15000004/2021002 IR 015000004/20210032021-12-0707 December 2021 J.L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report 15000004/2021003(DNMS) IR 015000004/20210012021-04-20020 April 2021 J. L. Shepherd, NRC Form 591M Part 1, Inspection Report No. 15000004/2021001 IR 015000004/20200032020-06-24024 June 2020 Foss Therapy Services, NRC Form 591M Part 1, Inspection Report No. 15000004/2020003 IR 015000004/20200022020-05-19019 May 2020 EA-20-047; Christian Wheeler Engineering; Christian Wheeler Engineering - NRC Inspection Report 150-00004/2020-002 IR 015000004/20200012020-01-27027 January 2020 J. L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report No. 15000004/2020001 IR 015000004/20190032019-11-0101 November 2019 Alpha-Omega Services, Inc. - NRC Form 591M, Part 1, NRC Inspection Report 150-00004/2019-003 IR 015000004/20190012019-04-24024 April 2019 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2019001 (DNMS) IR 015000004/20180082019-01-11011 January 2019 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018008 (DNMS) IR 015000004/20180062018-11-28028 November 2018 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018006 (DNMS) IR 015000004/20180052018-11-0707 November 2018 Thermo Gamma-Metrics, LLC - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018005 (DNMS) IR 015000004/20180032018-07-17017 July 2018 Alpha-Omega Services, Inc. - NRC Form 591M Part 1, Inspection Report 15000004/2018003 IR 015000004/20180022018-05-21021 May 2018 J. L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report 15000004/2018002 IR 015000004/20170072017-11-14014 November 2017 Apex Testing Laboratories, Inc., - NRC Form 591 Part 1, Inspection Report 15000004/2017007 IR 015000004/19990051999-05-17017 May 1999 Discusses Insp Rept 15000004/99-05 on 990426-27 at Wyeth- Lederle Vaccines & Pediatrics,Malvern,Pennsylvania of Activities Authorized by California License CA-1777-19.No Violations Were Identified IR 015000004/19990041999-05-0303 May 1999 Discusses Insp Rept 15000004/99-04 on 990421 in Totowa,Nj. No Violations Noted.Insp Was Limited to Review of Loading of High Dose Rate Afterloader with New Ir-192 Source IR 015000004/19990011999-01-26026 January 1999 Insp Rept 15000004/99-01 on 990106.No Violations Noted. Major Areas Inspected:Examine Activities Under General License Per 10CFR150.20 IR 015000004/19980141998-11-0909 November 1998 Discusses Insp Rept 15000004/98-14 on 980818-19 & Forwards Notice of Violation Re Failure to Have Valid NRC License When Performing Licensable Activities on 980603-04 IR 015000004/19980051998-09-17017 September 1998 Discusses Insp Rept 15000004/98-05 on 980420-23.Violations Noted.Violation Re Failure to Obtain NRC Specific License as Required by 10CFR30.3 Prior to Using Radioisotopes in Area of Exclusive Federal Jurisdiction Aboard Research Vessels IR 015000004/19980081998-06-30030 June 1998 Discusses Insp Rept 15000004/98-08 on 980429.No Violations Were Identified.Insp Limited to Review of Source Removal from Base Pool Irradiator IR 015000004/19980071998-06-0404 June 1998 Discusses Insp Rept 15000004/98-07 on 980423.No Violations Noted.Insp Limited to Observations by Inspector,Interviews W/Personnel & Selected Examination of Representative Records Related to Activities within NRC Jurisdiction IR 015000004/19980091998-06-0303 June 1998 Insp Rept 15000004/98-09 on 980528.No Violations Noted.Major Areas inspected:five-yr Maint,Training,Radiation Surveys & Radiation Protection IR 015000004/19970071997-12-0505 December 1997 Discusses Insp Rept 15000004/97-07 Conducted on 971118-19 at Univ Hosp of Cleveland.Insp Included Review of Licensee Health Physics Practices.No Violations Were Noted IR 015000004/19970091997-11-21021 November 1997 Discusses Insp Rept 15000004/97-09 on 971028 & Forwards Nov.Violation Involved Failure to Comply W/Certain Us DOT Regulations Involving Shipping Papers & Failure to Maintain 10CFR19 & 34 at Temporary Job Site IR 015000004/19970031997-07-11011 July 1997 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 15000004/97-03 on 970609 IR 015000004/19960171997-03-17017 March 1997 Discusses Insp Rept 15000004/96-17 Ending 970127 & Forwards Notice of Violation.Violations Occurred Based on Findings from Insp & Info Provided During 970226 Enforcement Conference IR 015000004/19970011997-02-28028 February 1997 Discusses Insp Rept 15000004/97-01 on 970212.Insp Exam of Licensed Activities Re Radiation Safety & Compliance W/Nrc Regulations & License Conditions.No Violations Identified IR 015000004/19930131993-11-24024 November 1993 Insp Rept 15000004/93-13 on 930929-1025.Violation Being Considered for Escalated Enforcement Action.Major Areas Inspected:Concerns Involving Use of Byproduct Matl in Areas Under Federal Jurisdiction IR 015000004/19930091993-11-0101 November 1993 Ack Receipt of 930712 & 0824 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 15000004/93-09 IR 015000004/19930111993-09-10010 September 1993 Enforcement Conference Rept 15000004/93-11 on 930819.Major Areas Discussed:Violations Noted from Insp on 930729 & 30 IR 015000004/19930101993-08-13013 August 1993 Insp Rept 15000004/93-10 on 930729-30,Violation Identified & Being Considered for Escalated Enforcement Action IR 015000004/19900061990-09-28028 September 1990 Insp Rept 15000004/90-06 on 900928.No Violations or Deviations Noted.Major Areas Inspected:Instrument Calibr Work for Licensees IR 015000004/19890011989-05-24024 May 1989 Insp Rept 15000004/89-01 on 890512.No Noncompliance Noted. Major Areas Inspected:Agreement State License Working in Hawaii Under General License Provisions 10CFR150.20 2023-06-21
[Table view] Category:Safety and Compliance Inspection Record
MONTHYEARIR 015000004/20220042022-12-0606 December 2022 J.L. Shepherd & Associates, NRC Form 591M Part 1, Inspection Report No. 150-00004/2022004 IR 015000004/20220032022-05-0303 May 2022 J. L. Shepherd, NRC Form 591M Part 1, Inspection Report No. 15000004/2022003 IR 015000004/20210022022-01-20020 January 2022 J.L. Shepherd Associates, NRC Form 591M Part 1, Inspection Report 15000004/2021002 IR 015000004/20210032021-12-0707 December 2021 J.L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report 15000004/2021003(DNMS) IR 015000004/20210012021-04-20020 April 2021 J. L. Shepherd, NRC Form 591M Part 1, Inspection Report No. 15000004/2021001 IR 015000004/20200032020-06-24024 June 2020 Foss Therapy Services, NRC Form 591M Part 1, Inspection Report No. 15000004/2020003 IR 015000004/20200012020-01-27027 January 2020 J. L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report No. 15000004/2020001 IR 015000004/20190032019-11-0101 November 2019 Alpha-Omega Services, Inc. - NRC Form 591M, Part 1, NRC Inspection Report 150-00004/2019-003 IR 015000004/20190012019-04-24024 April 2019 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2019001 (DNMS) IR 015000004/20180082019-01-11011 January 2019 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018008 (DNMS) IR 015000004/20180062018-11-28028 November 2018 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018006 (DNMS) IR 015000004/20180052018-11-0707 November 2018 Thermo Gamma-Metrics, LLC - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018005 (DNMS) IR 015000004/20180032018-07-17017 July 2018 Alpha-Omega Services, Inc. - NRC Form 591M Part 1, Inspection Report 15000004/2018003 IR 015000004/20180022018-05-21021 May 2018 J. L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report 15000004/2018002 IR 015000004/20170072017-11-14014 November 2017 Apex Testing Laboratories, Inc., - NRC Form 591 Part 1, Inspection Report 15000004/2017007 2022-05-03
[Table view] Category:NRC Form 591
MONTHYEARIR 015000004/20220042022-12-0606 December 2022 J.L. Shepherd & Associates, NRC Form 591M Part 1, Inspection Report No. 150-00004/2022004 IR 015000004/20220032022-05-0303 May 2022 J. L. Shepherd, NRC Form 591M Part 1, Inspection Report No. 15000004/2022003 IR 015000004/20210022022-01-20020 January 2022 J.L. Shepherd Associates, NRC Form 591M Part 1, Inspection Report 15000004/2021002 IR 015000004/20210032021-12-0707 December 2021 J.L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report 15000004/2021003(DNMS) IR 015000004/20210012021-04-20020 April 2021 J. L. Shepherd, NRC Form 591M Part 1, Inspection Report No. 15000004/2021001 IR 015000004/20200032020-06-24024 June 2020 Foss Therapy Services, NRC Form 591M Part 1, Inspection Report No. 15000004/2020003 IR 015000004/20200012020-01-27027 January 2020 J. L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report No. 15000004/2020001 IR 015000004/20190032019-11-0101 November 2019 Alpha-Omega Services, Inc. - NRC Form 591M, Part 1, NRC Inspection Report 150-00004/2019-003 IR 015000004/20190012019-04-24024 April 2019 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2019001 (DNMS) IR 015000004/20180082019-01-11011 January 2019 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018008 (DNMS) IR 015000004/20180062018-11-28028 November 2018 Alpha-Omega Services, Inc. - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018006 (DNMS) IR 015000004/20180052018-11-0707 November 2018 Thermo Gamma-Metrics, LLC - NRC Form 591M Parts 1 & 3, Inspection Report 15000004/2018005 (DNMS) IR 015000004/20180032018-07-17017 July 2018 Alpha-Omega Services, Inc. - NRC Form 591M Part 1, Inspection Report 15000004/2018003 IR 015000004/20180022018-05-21021 May 2018 J. L. Shepherd & Associates - NRC Form 591M Part 1, Inspection Report 15000004/2018002 IR 015000004/20170072017-11-14014 November 2017 Apex Testing Laboratories, Inc., - NRC Form 591 Part 1, Inspection Report 15000004/2017007 2022-05-03
[Table view] |
Inspection Report - - 2018005 |
---|
|
|
Text
NRC FORM 591M PART 1 U.S. NUCLEAR REGULATORY COMMISSION (07-2012)
10CFR2.201 SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION 1. LICENSEE/LOCATION INSPECTED: 2. NRG/REGIONAL OFFICE Thermo Gamma-Metrics, LLC Region III 10010 Mesa Rim Road U.S. Nuclear Regulatory Commission San Diego, CA 92121 2443 Warrenville Road, Suite 210 Location inspected: Job site in Charlevoix, MI Lisle, IL 60532-4352 REPORT NUMBER(S) 2018005 3. DOCKET NUMBER(S) 4. LICENSE NUMBER(S) 5. DATE(S) OF INSPECTION 150-00004 CA-3775-37 November 7, 2018 LICENSEE:
The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows:
[Z] Based on the inspec1ion findings, no violations were identifie D Previous violation(s) close D The violations(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy, to exercise discretion, were satisfie Non-cited violation(s) were discussed involving the following requirement(s):
D During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements and are being cited in accordance with NRC Enforcement Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.1 (Violations and Corrective Actions)
Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified. This statement of corrective actions is made in accordance with the requirements of 1O CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requeste TITLE PRINTED NAME SIGNATURE DATE LICENSEE'S REPRESENTATIVE NRC INSPECTOR Ryan Craffey 11/16/2018 BRANCH CHIEF Aaron Mccraw 11/30/2018 NRC FORM 591M PART 1 (07-2012)
NRC FORM 591M PART 3 U.S. NUCLEAR REGULATORY COMMISSION (07-2012)
10 CFR 2.201 Docket File Information SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION 1. LICENSEE/LOCATION INSPECTED: 2. NRG/REGIONAL OFFICE Thermo Gamma-Metrics, LLC Region III 10010 Mesa Rim Road U.S. Nuclear Regulatory Commission San Diego, CA 92121 2443 Warrenville Road, Suite 210 Location inspected: Job site in Charlevoix, MI Lisle, IL 60532-4352 REPORT NUMBER(S) 2018005 3. DOCKET NUMBER(S} 4. LICENSE NUMBER(S) 5. DATE(S) OF INSPECTION 150-00004 CA-3775-37 November 7, 2018 6. INSPECTION PROCEDURES USED 7. INSPECTION FOCUS AREAS 87126 FE 3-7 SUPPLEMENTAL INSPECTION INFORMATION 1. PROGRAM CODE(S} 2. PRIORITY 3. LICENSEE CONTACT 4. TELEPHONE NUMBER 03225 5 Ray Proctor - Alternate RSO (858) 812-2613 D Main Office Inspection Next Inspection Date: TBD D Field Office Inspection
[l] Temporary Job Site Inspection 16000 Bells Bay Road, Charlevoix, MI PROGRAM SCOPE This was an announced field inspection of a fixed gauge manufacturer authorized by the State of California to use radioactive material for numerous applications, including but not limited to manufacturing, distribution, installation, service, and disposal of gauging devices. The licensee used this license to perform installation, removal, and service of such devices in NRC jurisdiction under the terms of a reciprocity request approved in January 2018. The scope of this inspection was limited to observations oflicensed activities (sealed source handling, leak test collection and analysis) at the St Marys Cement facility in Charlevoix, Michigan, where two Thermo Fischer cross-belt elemental analyzers containing Cf-252 were in use under NRC Materials License No. 21-32044-01 (Docket No. 030-34588).
PERFORMANCE OBSERVATIONS: The inspector accompanied the licensee's field service engineer at the job site in Charlevoix and observed the handling of sealed sources incident to the collection of leak tests for both elemental analyzers. The inspector conducted independent and confirmatory surveys in the vicinity of these sources, and noted the use of adequate personal protective equipment, ALARA practices, and personnel monitoring (including extremities)
throughout. The inspector observed as the technician used a calibrated SE International Inspector instrument to analyze the leak test samples, and discussed with him the implementation of licensee procedures for responding to a test indicative of leakage. The inspector and technician also discussed the implementation of procedures for analyzer source exchanges, with a focus on receipt and security of packages containing radioactive material and ALARA practices implemented during exchange The inspector reviewed a selection of records available on site, including annual survey instrument calibrations and a record of leak test analysis for the client. The inspector also noted that the reciprocity change report filed by the licensee on October 22, 2018, accurately reflected the work performed. The inspector contacted the licensee's alternate RSO following the onsite inspection to request and review documentation demonstrating the adequacy of instrument used to perform leak test analysis, as well as documentation recent personnel monitoring results for the technicia No violations ofNRC requirements were identified as a result of this inspection. The inspector conducted an exit meeting with the alternate RSO on November 15, 2018.
NRG FORM 591M PART 3 (07-2012)
Craffey, Ryan From: Craffey, Ryan Sent: Monday, December 03, 2018 12:53 PM To: 'Proctor, Ray'
Cc: Barnes, Rob; Portz, Matthew Subject: NRC Inspection Report Attachments: NRC Inspection Report - Thermo Gamma-Metrics (Charlevoix 2018).pdf Good afternoon Mr. Proctor, Attached is a copy of the report for my inspection of Thermo Gamma-Metrics at a job site in Charlevoix, Ml last 111onth. Since no violations were identified, no additional action on your part is required, but if you have any questions or concerns about this inspection, please feel free to reach out any time.
Thank you!
Ryan Craffey Health Physicist US Nuclear Regulatory Commission Materials Inspection Branch, Region Ill (630) 829-9655 1