ENS 53778
ENS Event | |
---|---|
05:00 Dec 5, 2018 | |
Title | Three Minute Loss of Secondary Containment Vacuum |
Event Description | At 1010 [EST] on December 5, 2018, Secondary Containment differential pressure exceeded the Technical Specification Surveillance Requirement of greater than or equal to 0.25 inches of vacuum water gauge. This condition existed for approximately 3 minutes before the differential pressure was restored to normal when the Standby Gas Treatment system was manually initiated.
This event was caused by a trip of the service air compressor 39AC-2A. The loss of instrument air pressure caused Reactor Building ventilation to isolate and raise Secondary Containment differential pressure. The instrument air pressure was restored when 39AC-2A was isolated and the two backup air compressors started. This condition did not impact the leak tightness of Secondary Containment or the ability of the Standby Gas Treatment system to establish and maintain the required differential pressure. When Secondary Containment did not meet the Technical Specification Surveillance Requirement 3.6.4.1.1 for differential pressure, the Limiting Condition of Operation (LCO) was not met. Therefore, Secondary Containment was inoperable. This event is being reported under 10 CFR 50.72(b)(3)(v)(C). The licensee notified the NRC Resident Inspector. |
Where | |
---|---|
Fitzpatrick New York (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material | |
Time - Person (Reporting Time:+12.1 h0.504 days <br />0.072 weeks <br />0.0166 months <br />) | |
Opened: | Mark Hawes 17:06 Dec 5, 2018 |
NRC Officer: | Mark Abramovitz |
Last Updated: | Dec 5, 2018 |
53778 - NRC Website | |
Unit 1 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
FitzPatrick with 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material | |
WEEKMONTHYEARENS 538282019-01-16T05:00:00016 January 2019 05:00:00
[Table view]10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Differential Pressure Exceeded Technical Specification Allowed Value ENS 537782018-12-05T05:00:0005 December 2018 05:00:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Three Minute Loss of Secondary Containment Vacuum ENS 523432016-11-02T12:45:0002 November 2016 12:45:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Residual Heat Removal Valve Inoperable for Containment Isolation ENS 519852016-06-07T14:30:0007 June 2016 14:30:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Secondary Containment Doors Open Simultaneously ENS 515792015-12-02T01:36:0002 December 2015 01:36:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Inoperable Due to Secondary Containment Vacuum Being Less than Required Ts Value ENS 515122015-09-22T20:09:00022 September 2015 20:09:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Differential Pressure Exceeded Technical Specification Allowed Value ENS 514092015-09-18T18:08:00018 September 2015 18:08:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Equipment Failure Results in Inoperable Secondary Containment ENS 514052015-09-17T16:20:00017 September 2015 16:20:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Brief Loss of Secondary Containment Due to Both Airlock Doors Open Simultaneously ENS 512422015-07-20T11:40:00020 July 2015 11:40:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Temporary Loss of Differential Pressure in Secondary Containment ENS 505792014-10-28T21:08:00028 October 2014 21:08:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Reactor Building Vacuum Below Technical Specification Limit 2019-01-16T05:00:00 | |