ENS 53244
ENS Event | |
---|---|
09:08 Mar 4, 2018 | |
Title | Technical Specification Deviation |
Event Description | On 3/4/17 at 0308 CST, the MURR [University of Missouri Research Reactor] emergency power generator was switched out of automatic control for approximately 10 to 15 seconds while the reactor was operating due to human error. With the emergency power generator in manual control, the emergency electrical power system is considered inoperable because the emergency electrical power system would not have supplied power in the event of a loss of normal electrical power.
This email is a required notification per MURR Technical Specification (TS) 6.6.c.(1) to report to the NRC Operations Center that an Abnormal Occurrence as defined by MURR TS 1.1 happened. Specifically, MURR was not in compliance with the Limiting Condition for Operation TS 3.6.a which states, 'The reactor shall not be operated unless the emergency electrical power system is operable.' When the emergency power generator was switched out of automatic control, a Control Room alarm notified the Console Operator. Another operator placed the emergency power generator back into automatic mode which was the quickest way to regain compliance with TS 3.6.a. The MURR continued to operate at 10 MW. A detailed event report will follow within 14 days as required by MURR TS 6.6.c.(3). The licensee notified the NRC Research and Test Reactor Project Manager (Wertz). |
Where | |
---|---|
Univ Of Missouri-Columbia Columbia, Missouri (NRC Region 0) | |
License number: | R-103 |
Reporting | |
Non | |
Time - Person (Reporting Time:+28.1 h1.171 days <br />0.167 weeks <br />0.0385 months <br />) | |
Opened: | Bruce Meffert 13:14 Mar 5, 2018 |
NRC Officer: | Steven Vitto |
Last Updated: | Mar 5, 2018 |
53244 - NRC Website | |
Univ Of Missouri-Columbia with Non | |
WEEKMONTHYEARENS 553802021-07-26T22:31:00026 July 2021 22:31:00
[Table view]Non Reactor Shutdown Due to Control Rod Drive Failure ENS 546602020-04-09T19:32:0009 April 2020 19:32:00 Non Abnormal Occurrence ENS 546532020-04-08T06:00:0008 April 2020 06:00:00 Non Research and Test Reactor Forced Shutdown Due to Failure of Regulating Blade Drive Mechanism ENS 544532019-12-20T03:21:00020 December 2019 03:21:00 Non Technical Specification Deviation ENS 544362019-12-10T06:12:00010 December 2019 06:12:00 Non Technical Specification Violation Requiring Shutdown ENS 541872019-07-30T00:03:00030 July 2019 00:03:00 Non Technical Specification Deviation ENS 540342019-04-28T11:33:00028 April 2019 11:33:00 Non Control Blade Inoperable ENS 538492019-01-28T01:13:00028 January 2019 01:13:00 Non Control Blade Inoperable ENS 538412019-01-21T18:35:00021 January 2019 18:35:00 Non Deviation of Ts 3.3.A(1) for Anti-Siphon Device Found Inoperable ENS 534332018-05-30T12:10:00030 May 2018 12:10:00 Non Technical Specification Deviation ENS 532442018-03-04T09:08:0004 March 2018 09:08:00 Non Technical Specification Deviation ENS 531422017-12-30T13:17:00030 December 2017 13:17:00 Non Technical Specification Required Report for an Abnormal Occurrence ENS 528412017-07-05T05:00:0005 July 2017 05:00:00 Non Abnormal Occurrence Due to Source Range Inoperability During Reactor Start-Up ENS 527022017-04-20T19:49:00020 April 2017 19:49:00 Non Technical Specification Required Report for an Abnormal Occurrence 2021-07-26T22:31:00 | |