ENS 52567
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
04:23 Feb 20, 2017 | |
Title | Containment Penetration Exceeded Allowable Leakage |
Event Description | On 2/19/2017 at 2323 EST, during LLRT [local leak rate test] testing per 42SV-TET-001-2, 2T48F320 exceeded the maximum allowable leakage limit. The companion isolation valve in the same line (2T48F319) had previously failed LLRT. The failure of the 2T48F320 represents a failure of the 2T23X26 penetration to maintain primary containment integrity.
This event is reportable per 10CFR50.72(b)(3)(ii)(A) since the failure of the 2T23X26 penetration caused primary containment leakage to exceed La [allowable leakage] and thus represents a degraded principle safety barrier. CR [condition report] 10333178. NRC Resident Inspector has been notified. 2T48F319 and 2T48F320 are 18 inch dampers. This event places the licensee in a Technical Specification limit that requires the dampers to be repaired and pass LLRT prior to the plant entering Mode 3. |
Where | |
---|---|
Hatch Georgia (NRC Region 2) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
Time - Person (Reporting Time:+-3.15 h-0.131 days <br />-0.0187 weeks <br />-0.00431 months <br />) | |
Opened: | Rodger Lower 01:14 Feb 20, 2017 |
NRC Officer: | Howie Crouch |
Last Updated: | Feb 20, 2017 |
52567 - NRC Website | |
WEEKMONTHYEARENS 569592024-02-11T15:11:00011 February 2024 15:11:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Primary Containment Degraded ENS 563422023-02-07T22:38:0007 February 2023 22:38:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Primary Containment Degraded ENS 544632020-01-04T16:09:0004 January 2020 16:09:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Primary Containment Degraded ENS 525672017-02-20T04:23:00020 February 2017 04:23:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Containment Penetration Exceeded Allowable Leakage ENS 517422016-02-16T11:31:00016 February 2016 11:31:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Weld Overlay Flaw Did Not Meet Acceptance Criteria ENS 487952013-02-28T16:55:00028 February 2013 16:55:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Closed Cooling Water Isolation Valve Fails Local Leak Rate Test ENS 487722013-02-20T10:28:00020 February 2013 10:28:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition - Containment Penetration Fails Local Leak-Rate Testing ENS 440382008-03-06T09:00:0006 March 2008 09:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pin Hole Leak Discovered in 1 Inch Instrument Line During Rpv Pressure Test ENS 440052008-02-23T21:00:00023 February 2008 21:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Unacceptable Flaw in Rpv Cap-To-Pipe Weld ENS 432242007-03-09T05:30:0009 March 2007 05:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Main Steam Line Flow Instrument Line Pressure Boundary Leakage ENS 423722006-02-23T23:50:00023 February 2006 23:50:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition of Shroud Tie Rods 2024-02-11T15:11:00 | |