ENS 42199
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
09:39 Dec 13, 2005 | |
Title | Manual Reactor Trip Due to Loss of Condenser Vacuum |
Event Description | Point Beach Unit 1 was manually tripped at 0339 CST on 12/13/05 due to a loss of condenser vacuum caused by a mechanical failure of the running circulating water pump. All plant systems responded normally, including an auxiliary feedwater actuation.
The trip was uncomplicated. All rods fully inserted. MSIVs were isolated due to the loss of condenser vacuum so decay heat is being removed by the atmospheric dump valves. The licensee indicated that there are no known steam generator tube leak issues. All systems functioned as required. The licensee was not in any significant LCO at the time of the trip. The trip had no impact on the electrical lineup or on Unit 2 operations. The cause of the circ water pump failure is still under investigation but there is evidence of sheared bolts on the pump coupling. The licensee noted the turbine condenser rupture disks blew due to high pressure. The licensee notified the NRC Resident Inspector. |
Where | |
---|---|
Point Beach Wisconsin (NRC Region 3) | |
Reporting | |
10 CFR 50.72(b)(2)(iv)(B), RPS Actuation | |
LER: | 05000266/LER-2005-008 |
Time - Person (Reporting Time:+-2.95 h-0.123 days <br />-0.0176 weeks <br />-0.00404 months <br />) | |
Opened: | Jim Wilson 06:42 Dec 13, 2005 |
NRC Officer: | Bill Huffman |
Last Updated: | Dec 13, 2005 |
42199 - NRC Website | |
Unit 1 | |
---|---|
Reactor critical | Critical |
Scram | Yes, Manual Scram |
Before | Power Operation (100 %) |
After | Hot Standby (0 %) |
WEEKMONTHYEARENS 553902021-07-31T21:46:00031 July 2021 21:46:00
[Table view]10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip of Unit 1 ENS 537792018-12-05T06:00:0005 December 2018 06:00:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip on Loss of Main Condenser Vacuum ENS 515702015-11-29T01:12:00029 November 2015 01:12:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Trip Due to Generator Lockout After Voltage Regulator Malfunction ENS 506492014-12-03T02:50:0003 December 2014 02:50:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to Failure of Condensate Pump ENS 481892012-08-15T01:31:00015 August 2012 01:31:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unit 1 Manually Tripped in Anticipation of an Automatic Turbine Trip ENS 480532012-06-28T01:46:00028 June 2012 01:46:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to 100% Load Reject ENS 469572011-06-14T00:24:00014 June 2011 00:24:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Automatic Reactor Trip During Startup Physics Testing ENS 461292010-07-27T01:01:00027 July 2010 01:01:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to Loss of Condenser Vacuum ENS 460802010-07-09T11:47:0009 July 2010 11:47:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to a Feedwater Regulating Valve Failure ENS 460322010-06-19T11:36:00019 June 2010 11:36:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to Generator Lockout ENS 434072007-06-05T20:17:0005 June 2007 20:17:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip After Feedwater Valve Failure ENS 421992005-12-13T09:39:00013 December 2005 09:39:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Manual Reactor Trip Due to Loss of Condenser Vacuum ENS 407542004-05-15T16:54:00015 May 2004 16:54:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to Diver Entangled in Intake Crib 2021-07-31T21:46:00 | |