ENS 41151
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
00:20 Oct 20, 2004 | |
Title | Invalid Turbine Driven Auxiliary Feedwater Actuation |
Event Description | On October 19, 2004, McGuire Nuclear Station Unit 2 experienced an inadvertent actuation of the Turbine Driven Auxiliary Feedwater (TDCA) Pump. This event occurred when the steam supply valve to the pump failed open due to low pressure in the nitrogen supply to the valve's actuator. Further evaluation determined that the inadvertent actuation of the TDCA Pump was not in response to actual plant conditions or parameters satisfying the requirements for actuation of the pump. Since the TDCA Pump was not started in response to a valid signal, this represented an invalid actuation reportable per the requirements of 10 CFR 50.73 (a) (2) (iv) (A). However, as per 10 CFR 50.73(a)(1), McGuire is providing a telephone notification of this invalid actuation instead of submitting a written LER.
The following additional information is being provided as part of the telephone notification of this event: - The Unit 2 TDCA Pump actuated and injected water into all four of the Unit 2 Steam Generators - The actuation of the Unit 2 TDCA Pump was successful and complete. The licensee stated the total injection time was approximately 16 minutes and that a very small power increase was observed during the event. The NRC Resident Inspector has been notified by the licensee. |
Where | |
---|---|
Mcguire North Carolina (NRC Region 2) | |
Reporting | |
10 CFR 50.73(a)(1), Submit an LER, Invalid Actuation | |
Time - Person (Reporting Time:+181.58 h7.566 days <br />1.081 weeks <br />0.249 months <br />) | |
Opened: | Jeff Thomas 13:55 Oct 27, 2004 |
NRC Officer: | Bill Huffman |
Last Updated: | Oct 27, 2004 |
41151 - NRC Website | |
Unit 2 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
WEEKMONTHYEARENS 563452023-01-01T11:04:0001 January 2023 11:04:00
[Table view]10 CFR 50.73(a)(1), Submit an LER 60-DAY Optional Telephonic Notification of Invalid Actuation of Auxiliary Feedwater Pump ENS 507202014-11-16T04:55:00016 November 2014 04:55:00 10 CFR 50.73(a)(1), Submit an LER Invalid Actuation of 1A Emergency Diesel Generator (Edg) ENS 485502012-12-02T16:42:0002 December 2012 16:42:00 10 CFR 50.73(a)(1), Submit an LER 60-Day Report - Invalid Auxiliary Feedwater and Nuclear Service Water Pump Actuation ENS 484432012-09-30T03:37:00030 September 2012 03:37:00 10 CFR 50.73(a)(1), Submit an LER Inadvertent Alignment of Nuclear Service Water to Standby Nuclear Service Water Pond ENS 459132010-04-16T09:21:00016 April 2010 09:21:00 10 CFR 50.73(a)(1), Submit an LER Inadvertent Steam Admission to Afw Turbine ENS 450062009-02-23T08:06:00023 February 2009 08:06:00 10 CFR 50.73(a)(1), Submit an LER Inadvertent Actuation of Turbine Auxiliary Feedwater Pump ENS 416352005-04-09T14:39:0009 April 2005 14:39:00 10 CFR 50.73(a)(1), Submit an LER Invalid Specified System Actuation ENS 411512004-10-20T00:20:00020 October 2004 00:20:00 10 CFR 50.73(a)(1), Submit an LER Invalid Turbine Driven Auxiliary Feedwater Actuation 2023-01-01T11:04:00 | |