WEEKMONTHYEARENS 552242021-04-30T03:54:00030 April 2021 03:54:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection (Hpci) Declared Inoperable ENS 543302019-10-15T16:10:00015 October 2019 16:10:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection (Hpci) System Inoperable ENS 536172018-09-21T04:00:00021 September 2018 04:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded High Pressure Coolant Injection System Inoperable ENS 524782017-01-09T20:30:0009 January 2017 20:30:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Emergency Diesel Generators Non-Conforming with Licensing Basis for Tornado Generated Missiles ENS 524192016-12-09T03:37:0009 December 2016 03:37:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Surveillance Failure ENS 522642016-09-26T22:45:00026 September 2016 22:45:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection System Declared Inoperable ENS 516302015-12-31T11:30:00031 December 2015 11:30:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Inoperable ENS 483762012-10-04T13:59:0004 October 2012 13:59:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Both Trains of Control Room Emergency Ventilation System Out of Service ENS 469872011-06-26T04:30:00026 June 2011 04:30:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Piping Leak Isolated on High Pressure Coolant Injection ENS 466772011-03-16T20:47:00016 March 2011 20:47:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Declared Inoperable ENS 452892009-08-24T18:15:00024 August 2009 18:15:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Station Safety Grade Pneumatic Supply Issue ENS 449262009-03-21T16:07:00021 March 2009 16:07:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Declared Inoperable Following Failure of Valve to Fully Open During Surveillance Test ENS 449042009-03-12T20:20:00012 March 2009 20:20:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Declared Inoperable ENS 442902008-06-12T04:40:00012 June 2008 04:40:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection (Hpci) System Identified Inoperable During Surveillance ENS 432382007-03-14T18:55:00014 March 2007 18:55:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Declared Inoperable ENS 424782006-04-05T20:15:0005 April 2006 20:15:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Declared Inoperable (Hpci) ENS 416762005-05-07T01:36:0007 May 2005 01:36:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Degraded Pipe Restraint on Hpci Discharge Piping ENS 416382005-04-25T20:55:00025 April 2005 20:55:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Declared Inoperable ENS 415102005-03-21T22:00:00021 March 2005 22:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Declared Inoperable - Entering 14 Day Lco Action Statement ENS 414582005-03-03T23:25:0003 March 2005 23:25:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection System Inoperable ENS 411072004-10-09T05:15:0009 October 2004 05:15:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection System Condensate Storage Tank Suction Valve Failed to Auto-Close During Surveillance ENS 409732004-08-22T00:00:00022 August 2004 00:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Accident Mitigation - High Pressure Coolant Injection System Flow Controller Malfunction ENS 405932004-03-17T17:35:00017 March 2004 17:35:00 10 CFR 50.72(b)(3)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection System Inoperable ENS 405762004-03-08T16:30:0008 March 2004 16:30:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci System Inoperable Due to Failure of Torus Suction Valve to Fully Open ENS 403942003-12-16T20:40:00016 December 2003 20:40:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection System Inoperable ENS 403842003-12-10T23:00:00010 December 2003 23:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Reduction in Accident Mitigation Due to Improper Hpci Suction Transfer 2021-04-30T03:54:00
[Table view] |