05000456/FIN-2016007-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Operation of SX System Valves Results in Cavitation Damage and Pipe Leakage |
Description | A finding of very low safety significance and an associated NCV of Title 10 of the Code of Federal Regulations (CFR) Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, was self-revealed when the licensee failed to prescribe essential service water (SX) system operating and/or surveillance procedures appropriate to the circumstances. Specifically, the licensee failed to provide SX operating procedure guidance to limit the closure position of valves 1SX007, 2SX007 and 0SX007, such that cavitation-induced damage/failure of components did not occur or to establish a procedure to monitor and correct cavitation-induced damage prior to component failure associated with the operation of these valves. Consequently, a through-wall leak occurred downstream of valve 1SX007 that was caused by cavitation-induced wall loss at the neck of the pipe flange supporting this valve. The licensee replaced the damaged valve and piping and entered this issue into their CAP as Issue Report (IR) 02697962. The team determined that the performance deficiency was more than minor because it was associated with the Equipment Performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, continued operation of the SX007 valves without monitoring or correcting cavitation-induced damage could result in a more significant failure resulting in the loss of an SX train and/or an internal flooding event. The team determined that this finding was of very low safety significance because although it was determined to be a deficiency affecting the design or qualification of a mitigating structure, system, and component (SSC), the operability or functionality of the component was not affected. The team did not identify a cross-cutting aspect for this finding because the finding did not reflect current licensee performance. |
Site: | Braidwood |
---|---|
Report | IR 05000456/2016007 Section 4OA2 |
Date counted | Sep 30, 2016 (2016Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | D Betancourt E Duncan G O'Dwyer J Bozga M Holmberg |
Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion V |
INPO aspect | |
' | |
Finding - Braidwood - IR 05000456/2016007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2016Q3
Self-Identified List (Braidwood)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||