05000413/FIN-2012007-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | |
Description | The team identified a non-cited violation of 10 CFR 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to establish a procedure to ensure that the requirements in EQMM 1393.01-A01-00, Environmental Qualification Maintenance Manual, were not exceeded to maintain the environmental qualification of motor-operated valves (MOVs). The licensee entered the issue into the corrective action program as PIP C-12-7121, declared MOVs 1KCC37A, 1WL807B, and 2KCC37A as operable but degraded/nonconforming, and instituted guidance to periodically review the cycles of all MOVs to ensure the maximum limit is not exceeded. The licensees failure to establish a procedure to ensure the MOV cycle requirements of EQMM 1393.01-A01-00, were not exceeded was a performance deficiency. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems cornerstone attribute of procedure quality and adversely affected the cornerstone objective in that, the lack of procedural guidance to track the cycles of MOVs resulted in 1KCC37A, 1WL807B, and 2KCC37A exceeding their environmental qualification cycle limit of 2,000 cycles and decreased the reliability and capability of the MOVs. The team assessed the finding in accordance with Inspection Manual Chapter 0609, Significance Determination Process, Attachment 4, Initial Characterization of Findings, and determined the finding was of very low safety significance (Green) because the performance deficiency did not result in a loss of MOV operability. The finding was associated with the cross-cutting aspect of implementation and institutionalization of operating experience in the Operating Experience component of the Problem Identification and Resolution area. |
Site: | Catawba |
---|---|
Report | IR 05000413/2012007 Section 1R21 |
Date counted | Sep 30, 2012 (2012Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | C Baron D Jones S Kobylarz R Nease J Montgomery E Stamm A Alen T Su |
CCA | P.5, Operating Experience |
INPO aspect | CL.1 |
' | |
Finding - Catawba - IR 05000413/2012007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Catawba) @ 2012Q3
Self-Identified List (Catawba)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||