05000285/FIN-2015011-03
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Correct a Non-Conforming Condition Associated with Auxiliary Feedwater Valves |
Description | The inspectors identified a Green, non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the licensees failure to correct a condition adverse to quality. Specifically, the licensee failed to take corrective actions after identifying that the steam generator auxiliary feed containment isolation valves were not rated for the maximum temperature they would experience in service. The inspectors determined that on February 2, 2015, an NRC inspector questioned the licensee whether valves HCV-1107A and HCV-1108A were adequately designed for containment temperatures. The licensee determined that the design specification for the valves was 180F, and the containment temperature following a main steam line break was evaluated to be 374F. The fact that the valve was not designed for the most limiting conditions was a non-conforming condition of a safety related component, and was a condition adverse to quality. However, the licensee did not initiate a condition report to resolve and correct the condition. Additionally, the inspectors determined that in 2002, the licensee initiated Condition Report CR-2002-02124 after identifying elevated temperatures in the auxiliary feedwater piping. This condition report documented that the design specification for the two valves was 180F and had been exceeded in service. Although the condition report description recommended modifying the design of the valves, the licensee did not take actions to correct the condition. In both of these instances, the licensee recognized that the valve design temperature was not adequate for its application, but did not take action to resolve the discrepancy. The inspectors determined that although the inadequate design was a non-conforming condition, the valves were not inoperable until the licensee installed inappropriate elastomer material during the 2015 refueling outage as a result of inadequate design control. The licensee entered the failure to identify and correct the non-conforming design in their corrective action program as Condition Report CR-2015-08523. The licensees failure to take corrective action for a non-conforming condition was a performance deficiency. The performance deficiency is more than minor, and therefore a finding, because it is associated with the design control attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e. core damage). Specifically, the licensee failed to take corrective actions to ensure an adequate design for the steam generator auxiliary feed containment isolation valves HCV-1107A and HCV-1108A. Using Inspection Manual Chapter 0609, Attachment 04, Initial Characterization of Findings, and Appendix A, Exhibit 2, Mitigating Systems Screening Questions, the finding was determined to be of very low safety significance (Green) because although the finding was a deficiency affecting the design or qualification of a mitigating system, structure, or component, the system, structure, or component maintained its operability. The finding has a basis for decisions cross-cutting aspect in the human performance cross-cutting area since leaders and individuals did not verify their understanding or question the basis of decisions. Specifically, the licensee failed to understand the potential significance of the non-conforming design of the valves and the basis for not taking corrective actions [H.10]. (Section 4OA5.6) |
Site: | Fort Calhoun |
---|---|
Report | IR 05000285/2015011 Section 4OA5 |
Date counted | Sep 30, 2015 (2015Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 93812 |
Inspectors (proximate) | G Miller M Langelier R Kumana |
Violation of: | 10 CFR 50 Appendix B Criterion XVI |
CCA | H.10, Bases for Decisions |
INPO aspect | CO.2 |
' | |
Finding - Fort Calhoun - IR 05000285/2015011 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Fort Calhoun) @ 2015Q3
Self-Identified List (Fort Calhoun)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||